Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Sunricher Technology Limited Covered Equipment Certification Attestation Letter 8/19/2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AHST-904X Shenzhen Sunricher Technology Limited certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Shenzhen Sunricher Technology Limited certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Sunny Zou Title: Manager Company Name: Shenzhen Sunricher Technology Limited Date: 8/19/2024
ShenzhenSunricherTechnologyLimited * the applicantmust designatea contactlocatedin the UnitedStatesfor purposesof actingas the applicant’s agent for serviceof process,regardlessof whetherthe applicantis a domesticor foreign entity.An applicantlocatedin the UnitedStatesmay designateitself as the agent for serviceof process. U.S . Agent Designationfor Serviceof Process- CertificationAttestationLetter FederalCommunicationsCommission Authorizationand EvaluationDivision 7435 OaklandMills Road Columbia,MD 21046 USA ATTN.:ReviewingEngineer FCC ID: 2AHST-904X FRN of applicant:0023826787 Per section2.911(d)(7)of the FCC rules, ShenzhenSunricherTechnologyLimitedcertifiesthat the equipmentfor which authorizationis soughtis designatedto thefollowingU.S.agent*for serviceof process: CompanyName:UUX GROUPINC FCC RegistrationNumber(FRN):0033701590 PhysicalU.S. CompanyAddress:36 South 18th Avenue,Suite A Brighton,CO USA 80601 ContactPerson:Jack Fu Agent Email Address:[email protected] The abovecontactpersonacceptsthe obligationfor serviceof process. The applicantacceptsto maintainan agent for no less than one year after the granteehas terminatedall marketingand importationor the conclusionof any Commission-related proceedinginvolvingthe equipment. ApplicantSigned: Signed: Printedname:SunnyZou Title: Manager CompanyName:ShenzhenSunricher TechnologyLimited Date:8/19/2024 AgentSigned: Signed: Printedname: Jack Fu Title:Manager CompanyName:UUX GROUPINC Date:8/19/2024
Differences Declaration To whom concern, We company Shenzhen Sunricher Technology Limited hereby declares: The product models SR-ZG9041A-D, HL-SL-DIM-B, SR-XX9041A-D, ['X' ,can be any alphanumeric character or blank, stands fordifferent for marketing purpose] are identical in the same PCB layout, interior structure and electrical circuits, the only difference are appearance color and model name for commercial purpose. Authorized signature: Date: 2024-08-19
DATE : 2024-08-19 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Jason Wu of Global United Technology Services Co., Ltd.and No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Shenzhen Sunricher Technology Limited and 3rd Floor, B building, Jia'an Industrial Building, Liu Xian Third road, No.72 area, Xin'an Street, Baoan District, Shenzhen, China Signature: Name: Sunny Zou Title: Manager Company: Shenzhen Sunricher Technology Limited
DATE : 2024-08-19 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AHST-904X Product Name: Micro Smart Dimmer Request for Confidentiality To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Signature: Name: Sunny Zou Title: Manager Company: Shenzhen Sunricher Technology Limited
Label Size:3x3 cmTransparent base adhesive
FCC ID: 2AHST-904X RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Band Frequency Max output power (dBm) Output power (mW) Antenna gain (dBi) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Verdict ZigBee 2480MHz 7.45 5.56 -1.03 0.0009 1.0 PASS Remark: The max power density is less than MPE exempt limit, so it is compliance.
ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page1of10 TestingReport CustomerName:ShenzhenSunricherTechnologyLimited ProductName:MicroSmartDimmer SampleModel:SR-ZG9041A-D;SR-XX9041A-D ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2024.8.7 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02024.8.7Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults.....................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1VSWRparameters.....................................................................................................8 3.3.2VSWRdata................................................................................................................8 3.3.3Typicalfreespaceefficiencyandgain......................................................................8 3.3.4Typicalfreespaceradiationpattern...........................................................................9 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 103Building1TingweilndustrialPark,No.6,LiufangRoad,Zone 67Xingdong,Xin'anSubdistrict,Bao'anDistrict,Shenzhen,Guangdong,China Tel 13682621346 E-mail [email protected] Equipment Alltheequipmentusedinthereportisfixedin103Building1Tingweilndustrial Park,No.6,LiufangRoad,Zone67Xingdong,Xin'anSubdistrict,Bao'anDistrict, Shenzhen,Guangdong,China 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2023.5.112024.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2023.5.112024.5.10 1.4Testenvironment Temperature 24.1°C Humidity 58%RH Pressure 100.21kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page5of10 2.SampleInformation 2.1Clientinformation Name ShenzhenSunricherTechnologyLimited Address / Contacts / Tel / E-mail / Manufacturer ShenzhenSunricherTechnologyLimited 2.2DescriptionofEUT(S) ProductName MicroSmartDimmer SampleModel SR-ZG9041A-D;SR-XX9041A-D ['X',canbeanyalphanumericcharacterorblank,standsfordifferentfor marketingpurpose] AntennaSize / SerialNo. / AntennaType ExternalAntenna TestItem VSWR;Antennagain;Efficiency;Radiationpattern FrequencyRange 2400-2500MHz ReceivedDate 2024.8.6 TestDate 2024.8.6 Remark / ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page6of10 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page7of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern VSWR Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty VSWR±0.3 Antennagain±0.72dB Radiationefficiency±0.72dB ReportNo.:RFI-LAB-RF-202408-HH07 QP030-E41 Page8of10 3.3Testdata 3.3.1VSWRparameters 3.3.2VSWRdata 3.3.3Typicalfre…
Text truncated - open the document above for the full version.
Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 20 1. Duty Cycle 1.1 Test Result Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) Zigbee SISO 2405 0.555 0.812 68.35 1.65 0.06 2445 0.555 0.812 68.35 1.65 0.03 2480 0.556 0.812 68.47 1.64 0.02 Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 20 1.2 Test Graph Zigbee_LCH_2405MHz_Ant1_NTNV Zigbee_MCH_2445MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 20 Zigbee_HCH_2480MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 20 2. Bandwidth 2.1 Test Result 2.1.1 OBW Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit Zigbee SISO 2405 1 2.290 / Pass 2445 1 2.296 / Pass 2480 1 2.293 / Pass 2.1.2 6dB BW Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit Zigbee SISO 2405 1 1.478 >=0.5 Pass 2445 1 1.479 >=0.5 Pass 2480 1 1.469 >=0.5 Pass Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 20 2.2 Test Graph 2.2.1 OBW Zigbee_LCH_2405MHz_Ant1_NTNV Zigbee_MCH_2445MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 20 Zigbee_HCH_2480MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 20 2.2.2 6dB BW Zigbee_LCH_2405MHz_Ant1_NTNV Zigbee_MCH_2445MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 20 Zigbee_HCH_2480MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 20 3. Maximum Conducted Output Power 3.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit Zigbee SISO 2405 7.31 <=30 Pass 2445 7.39 <=30 Pass 2480 7.45 <=30 Pass Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 20 3.2 Test Graph Zigbee_LCH_2405MHz_Ant1_NTNV Zigbee_MCH_2445MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 20 Zigbee_HCH_2480MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 20 4. Maximum Power Spectral Density 4.1 Test Result Mode TX Type Frequency (MHz) Maximum PSD (dBm/3kHz) Verdict ANT1 Limit Zigbee SISO 2405 -7.74 <=8 Pass 2445 -7.66 <=8 Pass 2480 -7.92 <=8 Pass Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 20 4.2 Test Graph Zigbee_LCH_2405MHz_Ant1_NTNV Zigbee_MCH_2445MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 20 Zigbee_HCH_2480MHz_Ant1_NTNV Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 15 of 20 5. Unwanted Emissions In Non-restricted Frequency Bands 5.1 Test Result 5…
Text truncated - open the document above for the full version.
Global United Technology Services Co., Ltd. Report No.: GTS2024070476F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 33 TEST REPORT Applicant: Shenzhen Sunricher Technology Limited Address of Applicant: 3rd Floor, B building, Jia'an Industrial Building, Liu Xian Third road, No.72 area, Xin'an Street, Baoan District, Shenzhen, China Manufacturer/ Factory: Shenzhen Sunricher Technology Limited Address of Manufacturer/ Factory: 3rd Floor, B building, Jia'an Industrial Building, Liu Xian Third road, No.72 area, Xin'an Street, Baoan District, Shenzhen, China Equipment Under Test (EUT) Product Name: Micro Smart Dimmer Model No.: SR-ZG9041A-D, HL-SL-DIM-B, SR-XX9041A-D, ['X' ,can be any alphanumeric character or blank, stands fordifferent for marketing purpose] FCC ID: 2AHST-904X Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: July 31, 2024 Date of Test: July 31, 2024-August 19, 2024 Date of report issued: August 19, 2024 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 33 2 Version Version No. Date Description 00 August 19, 2024 Original Prepared By: Date: August 19, 2024 Project Engineer Check By: Date: August 19, 2024 Reviewer Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 33 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED EMISSIONS ................................................................................................................... 11 7.3 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 14 7.4 CHANNEL BANDWIDTH ...................................................................................................................... 15 7.5 POWER SPECTRAL DENSITY ............................................................................................................. 16 7.6 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 17 7.6.1 Conducted Emission Method ..................................................................................................... 17 7.6.2 Radiated Emission Method ........................................................................................................ 18 8 TEST SETUP PHOTO ............................................................................................................................ 33 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 33 Report No.: GTS2024070476F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Z…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 5.56 mW |

LED Controllers
Equipment Class
DTS - Digital Transmission System
FOH Smart Switch
Equipment Class
DTS - Digital Transmission System