Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PREFACE Thank you for purchasing our Walkie-Talkie. This easy-to-use radio will deliver you secure, instant and reliable communications at peak efficiency. Please read this manual carefully before use. The information presented herein will help you to derive maximum performance from your radio. To begin operation, please fully charge the radios. 1.Radi o Overview 2.Main Feature ▲Frequency Band:462.5625MHz~462.7125MHz and 462.5500MHz~462.7250MHz ▲15 C hannel ▲PC Programmable ▲5 Level Volume Adjustment ▲CTCSS, DCS 3.Basic Operation ■Power On/Off a. Press key for more than two seconds to turn on the radio. b. Press key again to turn off the radio. ■Walkie Talkie PTT (PUSH-TO-TALK) 1. Press and hold down the PTT button to transmit (the indicator light turns red). 2. Release PTT button to receive. ■Channel Selection 1. Press key to increase the channel number; Press key to decrease the channel number. The channel number is customized. The factory setting is 16 channels. ■Volume Selection Press to increase the volume. Press to decrease the volume. FCCstatement ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1) thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterference received, includinginterferencethatmaycauseundesiredoperation. Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecould voidthe user'sauthoritytooperatetheequipment. NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates, usesandcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycause harmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterference willnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradio ortelevisionreception, whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotryto correcttheinterferencebyoneormoreofthefollowing measures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Thisdeviceanditsantenna(s)mustnotbeco-locatedoroperationinconjunctionwithanyother antennaor transmitter. Holdthetransmitterapproximately2inches(25mm)fromyourfaceandspeakinanormalvoice, withthe antennapointedupandaway. SpecificAbsorptionRate(SAR)information: walkie-talkiemeetsthegovernment'srequirementsforexposuretoradiowaves.Theguidelines arebasedonstandardsthatweredevelopedbyindependentscientificorganizationsthrough periodicandthoroughevaluationofscientificstudies.Thestandardsincludeasubstantialsafety margindesignedtoassurethesafetyofallpersonsregardlessofageorhealth.FCCRFExposure InformationandStatementtheSARlimitofUSA(FCC)is8.0W/kgaveragedoveronegramof tissue.Devicetypes:walkie-talkiehasalsobeentestedagainstthisSARlimit. Thisdevicewastestedfortypicalbody-wornoperationswiththebackofthewalkie-talkiekept 0mmbody-wornSideand25mmFrontoffaceSide.TomaintaincompliancewithFCCRF exposurerequirements,useaccessoriesthatmaintain0mmbody-wornSideand25mmFrontof faceSideseparationdistancebetweentheuser'sbodyandthebackofthewalkie-talkie.Theuse of beltclips,holstersandsimilaraccessoriesshouldnotcontainmetalliccomponentsinitsassembly. TheuseofaccessoriesthatdonotsatisfytheserequirementsmaynotcomplywithFCCRF exposurerequirements,andshouldbeavoided. RFEnergyExposureAwarenessandControlInformationandOperationalInstructionsfor OccupationalUse Notice:thisradioisintendedforuseinoccupational/controlledconditionswhereusershavefull knowledge oftheirexposureandcanexercisecontrolovertheirexposuretomeettheoccupationallimitsin FCCand Internationalstandards.ThisradiodeviceisNOTauthorizedforgeneralpopulationconsumeruse. FederalCommunicationCommission(FCC)Regulations WhenWaterproofwalkie-talkieisusedasaconsequenceofemployment,theFCCrequiresusers tobe fullyawareofandabletocontroltheirexposuretomeetoccupationalrequirement.Exposure awarenesscan befacilitatedbytheuseofaproductlabeldirectinguserstospecificuserawarenessinformation. Your Waterproofwalkie-talkiehasaRFExposureProductLabel.Also,yourWaterproofwalkie-talkie Radio usermanualincludesinformationandoperatinginstructionsrequiredtocontrolyourRFexposure and satisfycompliancerequirements. CompliancewithRFExposureStandards YourWaterproofwalkie-talkieisdesignedandtestedtocompliancewithanumberofnationaland internationalstandardsandguidelinesforhumanexposuretoradiofrequencyelectromagnetic energy.This radiocompliancewiththeIEEE(FCC)andICNIRPexposurelimitsforoccupational/controlledRF exposure environmentsatoperatingdutyfactorsofupto50%talk–50%listenandisapprovedfor occupationaluse only.IntermsofmeasuringRFenergyforcompliancewiththeseexposureguidelines,yourradio generates measureableRFenergyonlywhileitistransmitting(duringtalking),notwhenitisreceiving (listening)orin standbymode. YourWaterproofwalkie-talkiecomplieswiththefollowingRFenergyexposurestandardsand guidelines: ●UnitedStatesFederalCommunicationsCommission(FCC),CodeofFederalRegulations; ●InstituteofElectricalandElectronicEngineers(IEEE)C95.1 ●InternationalCommissiononNon-lionizingRadiationProtection(ICNIRP) RFExposureComplianceandControlGuidelinesandOperatingInstructionsforTwo-WayRadio Operations Tocontrolyourexposureandensurecompliancewiththeoccupational/controlledenvironment exposure limits,alwaysadheretothefollowingprocedures; ●DONOTremovetheRFExposureLabelfromthedevice ●Userawarenessinstructionsshouldaccompanydevicewhentransferredtootherusers. OperationalInstructionsandTrainingGuidelines Toensureoptimalperformanceandcompliancewiththeoccupational/controlledenvironmentRF energy exposurelimitsintheabovestandardsandguidelines,usersshouldtransmitnomorethan50%of thetime andalwaysadheretothefollowingproced…
Text truncated - open the document above for the full version.
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2AIJ4-T-BL8 T-BL8 We, Applicant Company Name: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address: 659 Xingpu, Xiamei Town, Nan’an City, Fujian Province, China Phone: 0595-86769179 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of it’s successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date: 2026/3/17 Printed Name of Signee: YUZHAN HONG/Manager Company: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address: 659 Xingpu, Xiamei Town, Nan’an City, Fujian Province, China Phone: 0595-86769179 Fax: / Email: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2AIJ4-T-BL8 T-BL8 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Parts Lists • the Tune Up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date: 2026/3/17 Printed Name of Signee: YUZHAN HONG/Manager Company: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address: 659 Xingpu, Xiamei Town, Nan’an City, Fujian Province, China Phone: 0595-86769179 Fax: / Email: [email protected]
FCCID:2AIJ4-T-BL8 ExternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2AIJ4-T-BL8 Fig.3 Fig.4 FCCID:2AIJ4-T-BL8 Fig.5 Fig.6 FCCID:2AIJ4-T-BL8 Fig.7
FCCID:2AIJ4-T-BL8 LabelandLocation Size:L:15mm*W:15mm LabelandLocation FCCID:2AIJ4-T-BL8
FCCID:2AIJ4-T-BL8 InternalPhotosoftheEUT Fig.1 Fig.2 RF Antenna FCCID:2AIJ4-T-BL8 Fig.3 Fig.4
Page 1 of 67 Report No.: AiTSZ-260201105FW1 FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093) and IEEE Std 1528-2013 Product Name: Walkie-Talkie Model No.: T-BL8 Serial Model: / Brand Name: / Report No.: AiTSZ-260201105FW1 FCC ID: 2AIJ4-T-BL8 Prepared for Quanzhou HengLiDa Tel-Equipment Co.,Ltd. 659 Xingpu, Xiamei Town, Nan'an City, Fujian Province, China Prepared by Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Page 2 of 67 Report No.: AiTSZ-260201105FW1 TEST RESULT CERTIFICATION Applicant’s name..................: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address..................................: 659 Xingpu, Xiamei Town, Nan'an City, Fujian Province, China Manufacturer's Name...........: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address..................................: 659 Xingpu, Xiamei Town, Nan'an City, Fujian Province, China Product description Product name.........................: Walkie-Talkie Trademark .............................: / Model and/or type reference ..: T-BL8 Serial Model............................: / Standards..............................: FCC 47 CFR Part 2(2.1093) IEEE Std 1528-2013 Published RF exposure KDB procedures This device described above has been tested by Guangdong Asia Hongke Test Technology Limited. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01.Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093). The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited, this document may be altered or revised by Guangdong Asia Hongke Test Technology Limited, personal only, and shall be noted in the revision of the document. Test Sample Number ..............................:AiTSZ-260201105-1 Date of Test Date (s) of performance of tests .............:Feb. 24, 2026 Date of Issue...........................................:Feb. 25, 2026 Test Result ..............................................:Pass Reviewed by: Approved by: Ken Zou Jack Li Page 3 of 67 Report No.: AiTSZ-260201105FW1 ※ ※ Revision History ※ ※ REV.DESCRIPTIONISSUED DATEREMARK Rev.1.0Initial Test Report ReleaseFeb. 25, 2026Jack Li Page 4 of 67 Report No.: AiTSZ-260201105FW1 TABLE OF CONTENTS 1.General Information............................................................................................6 1.1.RF exposure limits....................................................................................6 1.2.Statement of Compliance........................................................................7 1.3.EUT Description.......................................................................................8 1.4.Test specification(s)..................................................................................8 1.5.Ambient Condition...................................................................................8 1.6.Test Facility...............................................................................................9 2.SAR Measurement System.................................................................................10 2.1.SATIMO SAR Measurement Set-up Diagram.........................................10 2.2.Robot.....................................................................................................11 2.3.Probe......................................................................................................12 2.3.1.E-Field Probe Calibration.................................................................12 2.4.Phantoms...............................................................................................13 2.5.Technical Data........................................................................................14 2.6.Device Holder.........................................................................................15 2.7.Test Equipment List................................................................................17 3.SAR Measurement Procedures..........................................................................20 3.1.Power Reference....................................................................................20 3.2.Area scan & Zoom scan..........................................................................20 3.3.Description of interpolation/extrapolation scheme..............................21 3.4.Volumetric Scan.....................................................................................22 3.5.Power Drift.............................................................................................22 4.System Verification Procedure...........................................................................23 4.1.Tissue Verification..................................................................................23 4.1.1.Tissue Dielectric Parameter Check Results......................................24 4.2.System Verification Procedure..............................................................25 4.2.1.System Verification Results.............................................................26 5.SAR measurement variabilit...............................................................................27 6.SAR Measurement Uncertainty.........................................................................28 7.RF Exposure Positions........................................................................................31 7.1.Generic device.......................…
Text truncated - open the document above for the full version.
Page 45 of 67 Report No.: AiTSZ-260201105FW1 Appendix D. Calibration Certificate Table of contents E Field Probe - SN 31/17 EPGO324 450 MHz Dipole - SN 38/18 DIP 0G450-465 Page 46 of 67 Report No.: AiTSZ-260201105FW1 Page 47 of 67 Report No.: AiTSZ-260201105FW1 Page 48 of 67 Report No.: AiTSZ-260201105FW1 Page 49 of 67 Report No.: AiTSZ-260201105FW1 Page 50 of 67 Report No.: AiTSZ-260201105FW1 Page 51 of 67 Report No.: AiTSZ-260201105FW1 Page 52 of 67 Report No.: AiTSZ-260201105FW1 Page 53 of 67 Report No.: AiTSZ-260201105FW1 Page 54 of 67 Report No.: AiTSZ-260201105FW1 Page 55 of 67 Report No.: AiTSZ-260201105FW1 Page 56 of 67 Report No.: AiTSZ-260201105FW1 Page 57 of 67 Report No.: AiTSZ-260201105FW1 Page 58 of 67 Report No.: AiTSZ-260201105FW1 Page 59 of 67 Report No.: AiTSZ-260201105FW1 Page 60 of 67 Report No.: AiTSZ-260201105FW1 Page 61 of 67 Report No.: AiTSZ-260201105FW1 Page 62 of 67 Report No.: AiTSZ-260201105FW1 Page 63 of 67 Report No.: AiTSZ-260201105FW1 Page 64 of 67 Report No.: AiTSZ-260201105FW1 Page 65 of 67 Report No.: AiTSZ-260201105FW1 Page 66 of 67 Report No.: AiTSZ-260201105FW1 Page 67 of 67 Report No.: AiTSZ-260201105FW1 Appendix E. Justification of the extended calibration Referring to KDB 865664 D01, if dipoles are verified in retum loss(< -20dB, within 20% of prior calibration), and inimpedance(within S ohm of prior calibration), the annual calibration is not necessary and the calibration interval canbe extended. <Head 450MHz> Return Loss (dB) Delta (%)ImpedanceDelta(ohm) Date of Measurement -25.95-45.0-Feb. 21, 2025 -26.25-1.1645.870.87Feb. 20, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. ※※END OF THE REPORT※※
ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China TESTREPORT FCCPart95 ReportReferenceNo. ....................... : FCCID. ................................................. : GRCTR260102032-01 2AIJ4-T-BL8 Compiledby (position+printedname+signature).: TestingEngineerJimmyWang Supervisedby (position+printedname+signature) . : ProjectEngineerKelleyZhang Approvedby (position+printedname+signature) . : ManagerSamWang Dateofissue.........................................:Feb.28,2026 TestingLaboratoryName ................ :ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address ................................................. : 101#,BuildingK&BuildingT,TheSecondIndustrialZone,Jiazitang Community,FenghuangStreet,GuangmingDistrict,Shenzhen,China Applicant’sname...............................: QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Address.................................................: 659Xingpu,XiameiTown,Nan'anCity,FujianProvince,China Testspecification ............................... : Standard ................................................ : FCCPart95 ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerand sourceofthematerial.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesno responsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthe reproducedmaterialduetoitsplacementandcontext. Testitemdescription ........................ : Walkie-Talkie TradeMark ............................................ : / Manufacturer ....................................... : QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Model/Typereference.........................: T-BL8 ListedModels......................................: / Modulation ........................................... : FM Hardwareversion.................................: V1.0 Softwareversion ................................. : V1.0 Frequency.............................................. 462.5500-462.7250MHz,462.5625-462.7125MHz Rating...............................................:DC5VPoweredbyadapter DC3.7VByLi-ionrechargeablebattery Result ..................................................... : PASS ReportNo.:GRCTR260102032-01Page2of29 TESTREPORT EquipmentunderTest: Walkie-Talkie Model/Type: T-BL8 ListedModels: / Applicant: QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Address: 659Xingpu,XiameiTown,Nan'anCity,FujianProvince,China Manufacturer: QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Address: 659Xingpu,XiameiTown,Nan'anCity,FujianProvince,China TestresultPass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR260102032-01Page3of29 Contents 1SUMMARY....................................................................................................................................................................4 1.1TESTSTANDARDS..........................................................................................................................................................4 1.2TESTDESCRIPTION............................................................................................................................................................4 2GENERALINFORMATION...............................................................................................................................................5 2.1GENERALREMARKS...........................................................................................................................................................5 2.2PRODUCTDESCRIPTION......................................................................................................................................................5 2.3DESCRIPTIONOFTESTMODESANDTESTFREQUENCY.............................................................................................................5 2.4EQUIPMENTUNDERTEST...................................................................................................................................................6 2.5SHORTDESCRIPTIONOFTHEEQUIPMENTUNDERTEST(EUT)...................................................................................................6 2.6BLOCKDIAGRAMOFTESTSETUP.........................................................................................................................................6 2.7RELATEDSUBMITTAL(S)/GRANT(S)....................................................................................................................................6 2.8MODIFICATIONS................................................................................................................................................................6 3TESTENVIRONMENT.....................................................................................................................................................7 3.1ADDRESSOFTHETESTLABORATORY......................................................................................................................................7 3.2TESTFACILITY...................................................................................................................................................................7 3.3ENVIRONMENTALCONDITIONS.............................................................................................................................................7 3.4STATEMENTOFTHEMEASUREMENTUNCERTAINTY...................................................................................................................8 3.5EQUIPMENTSUSEDDURINGTHETEST..................................................................................................................................8 4TESTCONDITIONSANDRESULTS…
Text truncated - open the document above for the full version.
FCCID:2AIJ4-T-BL8 TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCCID:2AIJ4-T-BL8 TestSetupPhoto(s)ofRFMeasurement Fig.3
Page 1 of 1 FCC ID: 2AIJ4-T-BL8 Front of face (Separation distance of 25mm) Body worn (Separation distance of 0mm)
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95B | 462.55 MHz - 462.725 MHz | 1.8072 W | 11KF3E | 2.5ppm |
| 2 | 95B | 462.5625 MHz - 462.7125 MHz | 1.8578 W | 11KF3E | 2.5ppm |

Walkie-Talkie
Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter