  3. 2AIJ4-T-M12

2AIJ4-T-M12Walkie-Talkie

Quanzhou HengLiDa Tel-Equipment Co.,Ltd.
Walkie-Talkie - FCC ID 2AIJ4-T-M12 - Quanzhou HengLiDa Tel-Equipment Co.,Ltd.
Click to zoom

Application Details

Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter
Date of Grant
Mar 24, 2026
Application Purpose
Original Equipment
Equipment Note
Walkie-Talkie
Frequency Range
462.55000000 - 462.72500000
Company
Quanzhou HengLiDa Tel-Equipment Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PREFACE ThankyouforpurchasingourMiniRadio.Thiseasy-to-useradiowilldeliveryou secure,instantandreliablecommunicationsatpeakefficiency.Pleasereadthis manualcarefullybeforeuse.Theinformationpresentedhereinwillhelpyoutoderive maximumperformancefromyourradio. Tobeginoperation,pleasefullychargetheradios. ProductInspection: Openthepackagecarefully,checktheproductandaccessoriesaccordingto thefollowinglist.Pleaseinformyoursupplierimmediatelyifanydamageor missinghappened. NO.ItemQTY 1FMtransceiver1 2ChargerandUSBcable1 3Usermanual1 MainFeature ▲Power:≤0.5W ▲Frequencyband:462.5500-462.7250MHz,462.5625-462.7125MHz ▲15storagechannels ▲Computerread-writefrequencyfunction ▲8-levelcontinuousvolumeadjustment ▲CTCSS/DCS ▲AIvoicecontrolledemission ▲Automaticfrequencycalibration ▲KeypadLockFunction BasicOperation Activatetheintelligentvoicefunction: Turnoffthedevice,holddownthe“PTT”keyandthenpressthe “O” keytoactivate theintelligentvoicefunction;Onlyrepeattothe“O”keydisablethisfeature. Afterthisfunctionisenabled,youonlyneedtosay"Start-call",Atthistime,thered lightison,andthenyoucantalktotheotherside;Then,yousimplysay"Talk-over" toendthecall. key Longpresstoturnon/offthewalkie-talkie;Pressthiskeybrieflyinstandbymodeto broadcastthecurrentchannel. ▲key Shortpressthiskeyinstandbymodetoaddchannel. ▼key Shortpressthiskeyinstandbymodetodecreasethechannel. ◀ key Shortpressthisbuttoninstandbymodetodecreasethevolume. ▶ key Instandbymode,longpressthiskeytolockthekeyboard.Atthistime,otherkeys exceptPTTkeyareinvalid,andthenlongpressthiskeytoreleasethekeyboard lockedfunction;Shortpressthisbuttoninstandbymodetoaddthevolume. PTTkey(transmitkey) Transmitandreceiveconversionkey:whentransmitting,pressthiskeyandspeak intothemicrophone;Whenreceiving,releasethiskey. Automaticfrequencycalibration Pressandholdthe"▼"buttontoturnonthemachine,andthemachine'strafficlights willflashalternatelytoindicateenteringthefrequencymatchingmode.Pressthe“▲” keytoexitthemode.Inthefrequencymatchingstate,whenanothermachineis transmitting,thegreenlightwillremainonafterthefrequencymatchingiscompleted. PressingPTTwillsaveit. Note:whenyouoperateotherkeysexceptPTTkey,pleasefirstconfirmwhetherthe keyboardislocked Ifspecificationsaresubjecttochangeduetotechnicalimprovement, pleaseforgiveusfornotgivingnotice. FCCstatement ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1) thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation. Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe user'sauthoritytooperatetheequipment. NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuantto Part15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterference inaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurina particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception, whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowing measures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Thisdeviceanditsantenna(s)mustnotbeco-locatedoroperationinconjunctionwithanyotherantennaor transmitter. Holdthetransmitterapproximately2inches(25mm)fromyourfaceandspeakinanormalvoice,withthe antennapointedupandaway. SpecificAbsorptionRate(SAR)information: walkie-talkiemeetsthegovernment'srequirementsforexposuretoradiowaves.Theguidelines arebasedonstandardsthatweredevelopedbyindependentscientificorganizationsthrough periodicandthoroughevaluationofscientificstudies.Thestandardsincludeasubstantialsafety margindesignedtoassurethesafetyofallpersonsregardlessofageorhealth.FCCRFExposure InformationandStatementtheSARlimitofUSA(FCC)is8.0W/kgaveragedoveronegramof tissue.Devicetypes:walkie-talkiehasalsobeentestedagainstthisSARlimit. Thisdevicewastestedfortypicalbody-wornoperationswiththebackofthewalkie-talkiekept 0mmbody-wornSideand25mmFrontoffaceSide.TomaintaincompliancewithFCCRF exposurerequirements,useaccessoriesthatmaintain0mmbody-wornSideand25mmFrontof faceSideseparationdistancebetweentheuser'sbodyandthebackofthewalkie-talkie.Theuseof beltclips,holstersandsimilaraccessoriesshouldnotcontainmetalliccomponentsinitsassembly. TheuseofaccessoriesthatdonotsatisfytheserequirementsmaynotcomplywithFCCRF exposurerequirements,andshouldbeavoided. RFEnergyExposureAwarenessandControlInformationandOperationalInstructionsforOccupationalUse Notice:thisradioisintendedforuseinoccupational/controlledconditionswhereusershavefullknowledge oftheirexposureandcanexercisecontrolovertheirexposuretomeettheoccupationallimitsinFCCand Internationalstandards.ThisradiodeviceisNOTauthorizedforgeneralpopulationconsumeruse. FederalCommunicationCommission(FCC)Regulations WhenWaterproofwalkie-talkieisusedasaconsequenceofemployment,theFCCrequiresuserstobe fullyawareofandabletocontroltheirexposuretomeetoccupationalrequirement.Exposureawarenesscan befacilitatedbytheuseofaproductlabeldirectinguserstospecificuserawarenessinformation.Your Waterproofwalkie-talkiehasaRFExposureProductLabel.Also,yourWaterproofwalkie-talkieRadio usermanualincludesinformationandoperatinginstructionsrequiredtocontrolyourRFexposureand satisfycompliancerequirements. CompliancewithRFExposureStandards YourWaterproofwalkie-talkieisdesignedandtestedtocompliancewithanumberofnationaland internationalstandardsandguidelinesforhumanexposuretoradiofrequencyelectromagneticenergy.This radiocompliancewiththeIEEE(FCC)andICNIRPexposurelimitsforoccupational/controlle…

Text truncated - open the document above for the full version.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2AIJ4-T-M12 T-M12 We, Applicant Company Name: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address: 659 Xingpu, Xiamei Town, Nan’an City, Fujian Province, China Phone: 0595-86769179 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of it’s successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, {新申请人签名} Signature Date: 2026/3/17 Printed Name of Signee: YUZHAN HONG/Manager Company: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address: 659 Xingpu, Xiamei Town, Nan’an City, Fujian Province, China Phone: 0595-86769179 Fax: / Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2AIJ4-T-M12 T-M12 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Parts Lists • the Tune Up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, {新申请人签名} Signature Date: 2026/3/17 Printed Name of Signee: YUZHAN HONG/Manager Company: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address: 659 Xingpu, Xiamei Town, Nan’an City, Fujian Province, China Phone: 0595-86769179 Fax: / Email: [email protected]

External Photos

FCCID:2AIJ4-T-M12 ExternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2AIJ4-T-M12 Fig.3 Fig.4 FCCID:2AIJ4-T-M12 Fig.5 Fig.6 FCCID:2AIJ4-T-M12 Fig.7

ID Label/Location Info

FCCID:2AIJ4-T-M12 LabelandLocation Size:L:15mm*W:15mm LabelandLocation FCCID:2AIJ4-T-M12

Internal Photos

FCCID:2AIJ4-T-M12 InternalPhotosoftheEUT Fig.1 Fig.2 RF Antenna FCCID:2AIJ4-T-M12 Fig.3 Fig.4

RF Exposure Info

Page 1 of 67 Report No.: AiTSZ-260201106FW1 FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093) and IEEE Std 1528-2013 Product Name: Walkie-Talkie Model No.: T-M12 Serial Model: / Brand Name: / Report No.: AiTSZ-260201106FW1 FCC ID: 2AIJ4-T-M12 Prepared for Quanzhou HengLiDa Tel-Equipment Co.,Ltd. 659 Xingpu, Xiamei Town, Nan'an City, Fujian Province, China Prepared by Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Page 2 of 67 Report No.: AiTSZ-260201106FW1 TEST RESULT CERTIFICATION Applicant’s name..................: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address..................................: 659 Xingpu, Xiamei Town, Nan'an City, Fujian Province, China Manufacturer's Name...........: Quanzhou HengLiDa Tel-Equipment Co.,Ltd. Address..................................: 659 Xingpu, Xiamei Town, Nan'an City, Fujian Province, China Product description Product name.........................: Walkie-Talkie Trademark .............................: / Model and/or type reference ..: T-M12 Serial Model............................: / Standards..............................: FCC 47 CFR Part 2(2.1093) IEEE Std 1528-2013 Published RF exposure KDB procedures This device described above has been tested by Guangdong Asia Hongke Test Technology Limited. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01.Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093). The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited, this document may be altered or revised by Guangdong Asia Hongke Test Technology Limited, personal only, and shall be noted in the revision of the document. Test Sample Number ..............................:AiTSZ-260201106-1 Date of Test Date (s) of performance of tests .............:Feb. 24, 2026 Date of Issue...........................................:Feb. 25, 2026 Test Result ..............................................:Pass Reviewed by: Approved by: Ken Zou Jack Li Page 3 of 67 Report No.: AiTSZ-260201106FW1 ※ ※ Revision History ※ ※ REV.DESCRIPTIONISSUED DATEREMARK Rev.1.0Initial Test Report ReleaseFeb. 25, 2026Jack Li Page 4 of 67 Report No.: AiTSZ-260201106FW1 TABLE OF CONTENTS 1.General Information............................................................................................6 1.1.RF exposure limits....................................................................................6 1.2.Statement of Compliance........................................................................7 1.3.EUT Description.......................................................................................8 1.4.Test specification(s)..................................................................................8 1.5.Ambient Condition...................................................................................8 1.6.Test Facility...............................................................................................9 2.SAR Measurement System.................................................................................10 2.1.SATIMO SAR Measurement Set-up Diagram.........................................10 2.2.Robot.....................................................................................................11 2.3.Probe......................................................................................................12 2.3.1.E-Field Probe Calibration.................................................................12 2.4.Phantoms...............................................................................................13 2.5.Technical Data........................................................................................14 2.6.Device Holder.........................................................................................15 2.7.Test Equipment List................................................................................17 3.SAR Measurement Procedures..........................................................................20 3.1.Power Reference....................................................................................20 3.2.Area scan & Zoom scan..........................................................................20 3.3.Description of interpolation/extrapolation scheme..............................21 3.4.Volumetric Scan.....................................................................................22 3.5.Power Drift.............................................................................................22 4.System Verification Procedure...........................................................................23 4.1.Tissue Verification..................................................................................23 4.1.1.Tissue Dielectric Parameter Check Results......................................24 4.2.System Verification Procedure..............................................................25 4.2.1.System Verification Results.............................................................26 5.SAR measurement variabilit...............................................................................27 6.SAR Measurement Uncertainty.........................................................................28 7.RF Exposure Positions........................................................................................31 7.1.Generic device.......................…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 45 of 67 Report No.: AiTSZ-260201106FW1 Appendix D. Calibration Certificate Table of contents E Field Probe - SN 31/17 EPGO324 450 MHz Dipole - SN 38/18 DIP 0G450-465 Page 46 of 67 Report No.: AiTSZ-260201106FW1 Page 47 of 67 Report No.: AiTSZ-260201106FW1 Page 48 of 67 Report No.: AiTSZ-260201106FW1 Page 49 of 67 Report No.: AiTSZ-260201106FW1 Page 50 of 67 Report No.: AiTSZ-260201106FW1 Page 51 of 67 Report No.: AiTSZ-260201106FW1 Page 52 of 67 Report No.: AiTSZ-260201106FW1 Page 53 of 67 Report No.: AiTSZ-260201106FW1 Page 54 of 67 Report No.: AiTSZ-260201106FW1 Page 55 of 67 Report No.: AiTSZ-260201106FW1 Page 56 of 67 Report No.: AiTSZ-260201106FW1 Page 57 of 67 Report No.: AiTSZ-260201106FW1 Page 58 of 67 Report No.: AiTSZ-260201106FW1 Page 59 of 67 Report No.: AiTSZ-260201106FW1 Page 60 of 67 Report No.: AiTSZ-260201106FW1 Page 61 of 67 Report No.: AiTSZ-260201106FW1 Page 62 of 67 Report No.: AiTSZ-260201106FW1 Page 63 of 67 Report No.: AiTSZ-260201106FW1 Page 64 of 67 Report No.: AiTSZ-260201106FW1 Page 65 of 67 Report No.: AiTSZ-260201106FW1 Page 66 of 67 Report No.: AiTSZ-260201106FW1 Page 67 of 67 Report No.: AiTSZ-260201106FW1 Appendix E. Justification of the extended calibration Referring to KDB 865664 D01, if dipoles are verified in retum loss(< -20dB, within 20% of prior calibration), and inimpedance(within S ohm of prior calibration), the annual calibration is not necessary and the calibration interval canbe extended. <Head 450MHz> Return Loss (dB) Delta (%)ImpedanceDelta(ohm) Date of Measurement -25.95-45.0-Feb. 21, 2025 -26.25-1.1645.870.87Feb. 20, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. ※※END OF THE REPORT※※

Test Report

ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China TESTREPORT FCCPart95 ReportReferenceNo. ....................... : FCCID. ................................................. : GRCTR260102033-01 2AIJ4-T-M12 Compiledby (position+printedname+signature).: TestingEngineerJimmyWang Supervisedby (position+printedname+signature) . : ProjectEngineerKelleyZhang Approvedby (position+printedname+signature) . : ManagerSamWang Dateofissue.........................................:Feb.28,2026 TestingLaboratoryName ................ :ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address ................................................. : 101#,BuildingK&BuildingT,TheSecondIndustrialZone,Jiazitang Community,FenghuangStreet,GuangmingDistrict,Shenzhen,China Applicant’sname...............................: QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Address.................................................: 659Xingpu,XiameiTown,Nan'anCity,FujianProvince,China Testspecification ............................... : Standard ................................................ : FCCPart95 ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerand sourceofthematerial.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesno responsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthe reproducedmaterialduetoitsplacementandcontext. Testitemdescription ........................ : Walkie-Talkie TradeMark ............................................ : / Manufacturer ....................................... : QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Model/Typereference.........................: T-M12 ListedModels......................................: / Modulation ........................................... : FM Hardwareversion.................................: V1.0 Softwareversion ................................. : V1.0 Frequency.............................................. 462.5500-462.7250MHz,462.5625-462.7125MHz Rating...............................................:DC5VPoweredbyadapter DC3.7VByLi-ionrechargeablebattery Result ..................................................... : PASS ReportNo.:GRCTR260102033-01Page2of29 TESTREPORT EquipmentunderTest: Walkie-Talkie Model/Type: T-M12 ListedModels: / Applicant: QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Address: 659Xingpu,XiameiTown,Nan'anCity,FujianProvince,China Manufacturer: QuanzhouHengLiDaTel-EquipmentCo.,Ltd. Address: 659Xingpu,XiameiTown,Nan'anCity,FujianProvince,China TestresultPass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR260102033-01Page3of29 Contents 1SUMMARY....................................................................................................................................................................4 1.1TESTSTANDARDS..........................................................................................................................................................4 1.2TESTDESCRIPTION............................................................................................................................................................4 2GENERALINFORMATION...............................................................................................................................................5 2.1GENERALREMARKS...........................................................................................................................................................5 2.2PRODUCTDESCRIPTION......................................................................................................................................................5 2.3DESCRIPTIONOFTESTMODESANDTESTFREQUENCY.............................................................................................................5 2.4EQUIPMENTUNDERTEST...................................................................................................................................................6 2.5SHORTDESCRIPTIONOFTHEEQUIPMENTUNDERTEST(EUT)...................................................................................................6 2.6BLOCKDIAGRAMOFTESTSETUP.........................................................................................................................................6 2.7RELATEDSUBMITTAL(S)/GRANT(S)....................................................................................................................................6 2.8MODIFICATIONS................................................................................................................................................................6 3TESTENVIRONMENT.....................................................................................................................................................7 3.1ADDRESSOFTHETESTLABORATORY......................................................................................................................................7 3.2TESTFACILITY...................................................................................................................................................................7 3.3ENVIRONMENTALCONDITIONS.............................................................................................................................................7 3.4STATEMENTOFTHEMEASUREMENTUNCERTAINTY...................................................................................................................8 3.5EQUIPMENTSUSEDDURINGTHETEST..................................................................................................................................8 4TESTCONDITIONSANDRESULTS…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2AIJ4-T-M12 TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCCID:2AIJ4-T-M12 TestSetupPhoto(s)ofRFMeasurement Fig.3

Test Setup Photos

Page 1 of 1 FCC ID:2AIJ4-T-M12 Front of face (Separation distance of 25mm) Body worn (Separation distance of 0mm)

Contact Information

Applicant

YUZHAN HONG(general manager)
[email protected]Fax: 0595-86766816

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place, Fullerton, · United States

Test Firm

Shenzhen GUOREN Certification Technology Service CSam Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
195B462.55 MHz - 462.725 MHz352.40 mW11KF3E2.5ppm
295B462.5625 MHz - 462.7125 MHz369.80 mW11KF3E2.5ppm
Confidentiality
Long Term
Grant Notes
Output Power listed is ERP. The reported SAR values are for a maximum duty cycle of 50 %. The highest reported SAR levels for head (face up), and body-worn accessories exposure conditions are 0.07 W/kg, and 0.26 W/kg respectively.

Other Applications from Quanzhou HengLiDa Tel-Equipment Co.,Ltd.

Walkie-Talkie - FCC ID 2AIJ4-T-BL8 - Quanzhou HengLiDa Tel-Equipment Co.,Ltd.
2AIJ4-T-BL8

Walkie-Talkie

Mar 24, 2026

Equipment Class

FRF - Part 95 Family Radio Face Held Transmitter