
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC statement: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Radiation Exposure Statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of thedevicemust be respected.
Sincerely, Name/Title: John Zhu// Company: Powerstick.com Inc. Address: 29 Camelot Drive Ottawa K2G 5W6 Canada Phone: 613-230-4840 Fax: Director of Engineering E-Mail: [email protected]
Page1of4FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity EXTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of4FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7
Page1of1FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L2.0cmx3.5cm) LabelLocation Clearcharge Model:805101 FCCID:2AITNCLEARCHARGE
Page1of5FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity INTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of5FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 CoilAntenna Page4of5FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10
Page 1 of 10 FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluationReport 1.ProductInformation FCCID:2AITNCLEARCHARGE Numberoftestedsamples2 SamplenumberA120822033-1(Engineersample),A120822033-2(Normalsample) ProductNameClearcharge ModelNumber805101 PowerSupply Input:DC5-12V,1.5-2A,15W Output:DC5-9V,2.0A ModulationTypeContinuousWave FrequencyRange110.3~205.0KHz AntennaTypeCoilAntenna HardwareversionClearcharge_V8 SoftwareversionClearchargeFW03 AccessoriesPhone ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18insomecaseshaveto demonstratecompliancewithRFexposurerequirements.Thepotentialforexposuremustbeassessed accordingtotheoperatingconfigurationsofthewirelesssystemandtheexposureconditionsofusers andbystanders.RFexposuremustbeevaluatedwiththeclientdevice(s)beingchargedbytheprimary atmaximumoutputpower.TheRFexposurerequirementsmustbedeterminedinconjunctionwiththe deviceoperatingcharacteristics,accordingtothemobileandportableexposurerequirementsin Section2.1091andSection2.1093oftherules.SARandMPElimitsdonotcoverthefrequencyrange forwirelesspowertransferapplicationswhichoperatebelow100kHzand300kHzrespectively; therefore,RFexposurecomplianceneedstobedeterminedwithrespectto1.1307(c)and(d)ofthe FCCrules. 2)Basedonthedesignandimplementationofthepowertransferapplication,itmustbeclearlyidentified ifmobileorportableRFexposureconditionsapply.Devicesthatareinstalledtoprovideseparationofat least20cmfromusersandbystandersmayqualifyformobileexposureconditions.Forsome conditionswhereusersandbystandersmaybeexposedatcloserthan20cm,section2.1091(d)(4)of therulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawirelesschargingpads,RFexposure evaluationshouldbeconductedassumingauserseparationdistanceof15cm.EandHfieldstrength measurementsornumericalmodelingmaybeusedtodemonstratecompliance.Measurementsshould bemadefromallsidesandthetopoftheprimary/clientpair,withthe15cmmeasuredfromthecenter oftheprobe(s)totheedgeofthedevice.Emissionsbetween100kHzto300kHzshouldbeassessed versusthelimitsat300kHzinTable1ofSection1.1310:614V/mand1.63A/m.AKDBinquiryis requiredtodeterminetheapplicableexposurelimitsbelow100kHz. 4)Portableexposureconditionsfrom100kHzto6GHzaredeterminedwithrespecttoSAR Page 2 of 10 FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity requirements.ExistingSARsystemsandtestproceduresaregenerallyintendedformeasurements above100MHz.Whilenumericalmodelingcanbeanalternative,theconstraintsofsubstantial computationalresourcesatlowfrequenciescouldintroducefurtherlimitations.Underthese circumstances,includingoperationsbelow100kHz,theCommissionmayconsideracombinationof analyticalanalysis,fieldstrength,radiatedandconductedpowermeasurements,inconjunctionwith somelimitednumericalmodelingtoassesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPEmeasurementproceduresmaybe adaptedtoevaluatewirelesspowertransferdevicesforcompliancewithrespecttomobileorportable exposureconditions.IfthegranteeoritstestlabhaveanyquestionsregardingRFexposureevaluation theyshouldcontacttheFCCLaboratorywithsufficientsystemoperatingconfigurationdetailsto determineifRFexposureevaluationisnecessaryand,ifrequired,howtoapplyspecifictestprocedures. Below100MHz,whenSARtestingisrequiredandthedeviceisoperatingatcloseproximitytopersons, informationondevicedesign,implementation,operatingconfigurations,exposureconditionsofusers andbystandersareneededtodeterminetheevaluationandtestingrequirements.Inaddition,the influenceofnearbyobjectsmayalsoneedconsiderationaccordingtothewirelesspowertransfer systemimplementation;forexample,theeffectsofplacingthedevice,itscoilsorradiatingelementson ornearmetallicsurfaces 3.EvaluationLimit 3.1Referevaluationmethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposure ConsiderationsforLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment Page 3 of 10 FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3the Emission-Limitsinthefrequencyrangefrom100KHzto300KHzshouldbeassessedversus thelimitsat300KHzinTable1ofCFR47–Section1.310asfollowi…
Text truncated - open the document above for the full version.
SpecificatonApproval (Customer): (CustomerP/N): (Model):MP-A2coil (IssueDate):2022.12.13 (DocumentRev.):RevNo1.0 (CustomerSignatures) (InnerSignatures) (Mfrs.):DongguanYouyiCoilElectronicTechnologyCo.,Ltd. (Add.):Floor4,No.57,BitaoStreet,ShijieTown,Dongguan,Guangdong (Tel):13415878813 (E-mail):[email protected] website:www.youyixq.com RevisionTheDetail Version1.0.0part1of4 (PrecheckBy):(CheckedBy):(ApprovedBy): (Department):(ED)(QC)(SD) (ApprovdeBy): Revision ItemBeforeAfterDataAttention SpecificationsReferenceDesigns ModelNumber CustomerP/N Version1.0.0part2of SpecificationsReferenceDesigns Version1.0.0part3of4 SupplierP/N YY20221213 1.(AppearanceSize):(mm) A19±1 B45±1 C50±1 D5±0.5 E 19±1 F45±1 G4±2 H3.5±1.5 I 1±0.2 J2.9MAX K L M N O P Q R S T U V W X Y Z 2.(SchematicDiagram): 3.(WindingParameters): WindingStartFinishTurnsLineDiameter Winding Way Winding Direction Layer&Circle SF12Turns0.08*105P Closewind ing α 1Layer 4.(ElectricalCharacteristics): ItemTerminalTestConditions Test Instrument ParameterUnitNumericalValue InductanceS-F 100KHz/ 1.00V 3250 Inductance@1 00KHz/1V μH10μH±10% QFactorS-F 100KHz/ 1.00V 3250Q@100KHz/1V80Ref ResistanceS-F 100KHz/ 1.00V 3250 DCR@25°CmΩ 75Max AntennaGain;0dBi MaterialBillOfMaterials Version1.0.0part4of4 MaterialList CustomerP/NSupplierP/N FSXQ*-AHN*0001-0004 No.MaterialNameMaterialSpecificationMaterialCodeManufacturer 1Wiresize0.08mm*90P 2TinHighTemperature 3GlueEnvironment 4FerritesizeG50*5*1mmMnZn 5 6 7 8 9 10 11 Approver Proofreader CartographerDate Benjamin2022-12-13
Page1of24FCCID:2AITNCLEARCHARGEReportNo.:LCSA120822033EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For Powerstick.comInc. Clearcharge TestModel:805101 Preparedfor:Powerstick.comInc. Address:29CamelotDr.Ottawa,Ontario,Canada,K2G5W6 Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkShajing Street,BaoanDistrict,Shenzhen,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:December08,2022 Numberoftestedsamples:2 Serialnumber:A120822033-1(Engineersample),A120822033-2(Normal sample) DateofTest:December08,2022~December12,2022 DateofReport:December12,2022 Page2of24FCCID:2AITNCLEARCHARGEReportNo.:LCSA120822033EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA120822033EA DateOfIssue......................................:December12,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet, BaoanDistrict,Shenzhen,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:Powerstick.comInc. Address................................................:29CamelotDr.Ottawa,Ontario,Canada,K2G5W6 TestSpecification Standard..............................................:FCCCFR47PART15C TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:Clearcharge TradeMark..........................................:N/A TestModel...........................................: 805101 PowerSupply......................................: Input:DC5-12V,1.5-2A,15W Output:DC5-9V,2.0A Result..................................................: Positive Compiledby: Supervisedby:Approvedby: LiHuan/AdministratorCaryLuo/Techniqueprincipal GavinLiang/Manager Page3of24FCCID:2AITNCLEARCHARGEReportNo.:LCSA120822033EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA120822033EA December12,2022 Dateofissue TestModel..............................:805101 EUT.........................................:Clearcharge Applicant...............................:Powerstick.comInc. Address..................................:29CamelotDr.Ottawa,Ontario,Canada,K2G5W6 Telephone...............................:/ Fax..........................................:/ Manufacturer........................:Powerstick.comInc. Address...................................:29CamelotDr.Ottawa,Ontario,Canada,K2G5W6 Telephone...............................:/ Fax..........................................:/ Factory...................................:Powerstick.comInc. Address...................................:29CamelotDr.Ottawa,Ontario,Canada,K2G5W6 Telephone...............................:/ Fax..........................................:/ Page4of24FCCID:2AITNCLEARCHARGEReportNo.:LCSA120822033EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000December12,2022InitialIssue-- Page5of24FCCID:2AITNCLEARCHARGEReportNo.:LCSA120822033EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION.............................................................................................6 1.1DescriptionofDevice(EUT).....................................................................................................6 1.2SupportequipmentList.............................................................................................................6 1.3ExternalI/OCable.....................................................................................................................6 1.4DescriptionofTestFacility........................................................................................................7 1.5StatementoftheMeasurementUncertainty.............................................................................7 1.6MeasurementUncertainty......................................................…
Text truncated - open the document above for the full version.
Page1of2FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PhotographsofTestSetup ConductedEmission-ACadapterchargemode RadiatedEmissionbelow30MHz-ACadapterchargemode Page2of2FCCID:2AITNCLEARCHARGE ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RadiatedEmissionbelow1GHz-ACadapterchargemode
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1103 MHz - 0.205 MHz | - |

FLYTE
Equipment Class
DTS - Digital Transmission System
Spot
Equipment Class
DTS - Digital Transmission System
Powerstation
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
PowerMag
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzHyperNova
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz