FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. INFINIX MOBILITY LIMITED/
  3. 2AIZN-X6511B

2AIZN-X6511BMobile Phone

INFINIX MOBILITY LIMITED
Mobile Phone - FCC ID 2AIZN-X6511B - INFINIX MOBILITY LIMITED
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 04, 2021
Application Purpose
Original Equipment
Date of Application
Sep 04, 2021
Equipment Note
Mobile Phone
Frequency Range
2402.00000000 - 2480.00000000
Company
INFINIX MOBILITY LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Infinix X6511B User Manual (A) 1 E E x x p p l l o o s s i i o o n n d d i i a a g g r r a a m m s s p p e e c c i i f f i i c c a a t t i i o o n n 1 FL(CTP+LCM) 2 F HSG 3 R Cam Rubber 4 R Flash Hood 5 PS Rubber 6 F Cam Rubber 7 Cam FF 8 R Cam Lens 9 Cam FF 10 Cam AF 11 PCBA MB 12 REC 13 SIM Holder 14 Cam Deco 15 Rear Frame 16 Screw M1.4*D2.5*L2.5 17 Screw M1.4*D2.5*L3.5 18 Batt Cover 19 Finger Print 20 SPK Frame 21 USB Rubber 22 PCBA SUB 23 Earjack Rubber 24 Coaxial Cable 25 Side Key FPC 26 Moto 27 Battery 28 2 Know your phone 1. Front camera 2. Volume + key 3. Volume - key 4. Power key ① 3 SIM/SD card installation 1. Power off mobile. 2. Refer to the following picture for SIM / SD card installation. 4 C C h h a a r r g g i i n n g g t t h h e e p p h h o o n n e e You can charge your device using a charger or by connecting it to the computer using a USB cable (comes with the phone). 1. Please remind the front and back of the plug. 2. Use only INFINIX charger and cables. Other chargers or cables may damage the device. This will invalidate your phone warranty. 5 F F C C C C S S t t a a t t e e m m e e n n t t 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and 6 receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. SAR Information Statement Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radiofrequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. * Tests for SAR are conducted with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a 7 wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when tested for use at the ear is 1.047W/Kg and when worn on the body, as described in this user guide, is 0.697W/Kg (Body-worn measurements differ among phone models, depending upon available accessories and FCC requirements). The maximum scaled SAR in hotspot mode is 0.853W/Kg. While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RFexposure guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/ oet/fccid after searching on FCC ID: 2AIZN-X6511B Additional information on Specific Absorption Rates (SAR) can be found on the Cellular Telecommunications Industry Asso-ciation (CTIA) web-site at http://www.wow-com.com. * In the United States and Canada, the SAR limit for mobile phones used by the public is 1.6 watts/kg (W/kg) averaged over one gram of tissue. The standard incorporates a sub-stantial margin of safety to give additional protection for the public and to account for any variations in 8 measurements. Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 10mm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not mee…

Text truncated - open the document above for the full version.

Cover Letter(s)

INFINIX MOBILITY LIMITED DATE :2021-9-2 Equipment Autorisation Division Federal Communications Commission 7345 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AIZN-X6511B Product Name: Mobile Phone Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential:  Schematics  Block diagram  Operation description  Tune up  BOM These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 2021-9-2 By: Yiting Luo Signature Printed Title: Manager On behalf of : INFINIX MOBILITY LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

INFINIX MOBILITY LIMITED DATE:2021-8-2 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act asAgent On our behalf, I appoint JianYan Testing Group Shenzhen Co., Ltd.; No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Communit y,Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China.;Bruce.Zhang, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with INFINIX MOBILITY LIMITED/ ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL Hong Kong Dated this 2021-8-2 By: Yiting Luo Signature Printed Title: Manager On behalf of : INFINIX MOBILITY LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

INFINIX MOBILITY LIMITED DATE :2021-9-2 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AIZN-X6511B Product Name: Mobile Phone Request for Short-Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.:  Test Setup Photos  External Photos  Internal Photos  User Manual The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. <Signature> Name Yiting Luo Title manager Company INFINIX MOBILITY LIMITED

External Photos

Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 21 of 32 8 EUT Constructional Details Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 22 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 23 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 24 of 32

ID Label/Location Info

label location label location

Internal Photos

Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 25 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 26 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 27 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 28 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 29 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 30 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 31 of 32 Report No: JYTSZB-R12-2101454 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 32 of 32 ------End of report------

Test Report

JianYan Testing Group Shenzhen Co., Ltd. Report No: JYTSZB-R12-2101457 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT (Bluetooth) Applicant: INFINIX MOBILITY LIMITED Address of Applicant: FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL CENTRE 31- 35 SHAN MEI STREET FOTAN NT Equipment Under Test (EUT) Product Name: Mobile Phone Model No.: X6511B Trade mark: INFINIX FCC ID: 2AIZN-X6511B Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: 03 Aug., 2021 Date of Test: 04 Aug., to 17 Aug., 2021 Date of report issued: 17 Aug., 2021 Test Result: PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 38 2 Version Version No. Date Description 00 17 Aug., 2021 Original Tested by: Date: 17 Aug., 2021 Test Engineer Reviewed by: Date: 17 Aug., 2021 Project Engineer Report No: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 38 3 Contents Page 1 COVER PAGE ............................................................................................................................................................. 1 2 VERSION ..................................................................................................................................................................... 2 3 CONTENTS ................................................................................................................................................................. 3 4 TEST SUMMARY ........................................................................................................................................................ 4 5 GENERAL INFORMATION ........................................................................................................................................ 5 5.1 CLIENT INFORMATION ....................................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................... 5 5.3 TEST ENVIRONMENT AND MODE ........................................................................................................................ 6 5.4 DESCRIPTION OF SUPPORT UNITS .................................................................................................................... 6 5.5 MEASUREMENT UNCERTAINTY .......................................................................................................................... 6 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD ....................................................................... 6 5.7 LABORATORY FACILITY ..................................................................................................................................... 6 5.8 LABORATORY LOCATION ................................................................................................................................... 6 5.9 TEST INSTRUMENTS LIST .................................................................................................................................. 7 6 TEST RESULTS AND MEASUREMENT DATA ...................................................................................................... 8 6.1 ANTENNA REQUIREMENT .................................................................................................................................. 8 6.2 CONDUCTED EMISSIONS .................................................................................................................................. 9 6.3 CONDUCTED OUTPUT POWER ........................................................................................................................ 12 6.4 20DB OCCUPY BANDWIDTH ............................................................................................................................ 13 6.5 CARRIER FREQUENCIES SEPARATION ............................................................................................................. 14 6.6 HOPPING CHANNEL NUMBER .......................................................................................................................... 15 6.7 DWELL TIME ......................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 1 of 51 Test Data Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT 1-DH1 2402 Ant1 -0.535 0 -0.535 30 Pass NVNT 1-DH1 2441 Ant1 2.354 0 2.354 30 Pass NVNT 1-DH1 2480 Ant1 3.599 0 3.599 30 Pass NVNT 2-DH1 2402 Ant1 1.338 0 1.338 21 Pass NVNT 2-DH1 2441 Ant1 4.007 0 4.007 21 Pass NVNT 2-DH1 2480 Ant1 5.168 0 5.168 21 Pass NVNT 3-DH1 2402 Ant1 2.236 0 2.236 21 Pass NVNT 3-DH1 2441 Ant1 4.907 0 4.907 21 Pass NVNT 3-DH1 2480 Ant1 5.977 0 5.977 21 Pass Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 51 Test Graphs Power NVNT 1-DH1 2402MHz Ant1 Power NVNT 1-DH1 2441MHz Ant1 Power NVNT 1-DH1 2480MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 51 Power NVNT 2-DH1 2402MHz Ant1 Power NVNT 2-DH1 2441MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 4 of 51 Power NVNT 2-DH1 2480MHz Ant1 Power NVNT 3-DH1 2402MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 5 of 51 Power NVNT 3-DH1 2441MHz Ant1 Power NVNT 3-DH1 2480MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 6 of 51 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 7 of 51 -20dB Bandwidth Condition Mode Frequency (MHz) Antenna -20 dB Bandwidth (MHz) Limit -20 dB Bandwidth (MHz) Verdict NVNT 1-DH1 2402 Ant1 0.87 0 Pass NVNT 1-DH1 2441 Ant1 0.881 0 Pass NVNT 1-DH1 2480 Ant1 0.919 0 Pass NVNT 2-DH1 2402 Ant1 1.256 0 Pass NVNT 2-DH1 2441 Ant1 1.251 0 Pass NVNT 2-DH1 2480 Ant1 1.254 0 Pass NVNT 3-DH1 2402 Ant1 1.254 0 Pass NVNT 3-DH1 2441 Ant1 1.217 0 Pass NVNT 3-DH1 2480 Ant1 1.226 0 Pass Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 8 of 51 Test Graphs -20dB Bandwidth NVNT 1-DH1 2402MHz Ant1 -20dB Bandwidth NVNT 1-DH1 2441MHz Ant1 -20dB Bandwidth NVNT 1-DH1 2480MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 9 of 51 -20dB Bandwidth NVNT 2-DH1 2402MHz Ant1 -20dB Bandwidth NVNT 2-DH1 2441MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 10 of 51 -20dB Bandwidth NVNT 2-DH1 2480MHz Ant1 -20dB Bandwidth NVNT 3-DH1 2402MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 11 of 51 -20dB Bandwidth NVNT 3-DH1 2441MHz Ant1 -20dB Bandwidth NVNT 3-DH1 2480MHz Ant1 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 12 of 51 Report No.: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 13 of 51 Carrier Frequencies Separation Condition Mode Antenna Hopping Freq1 (MHz) Hopping Freq2 (MHz) HFS (MHz) Limit (MHz) Verdict NVNT 1-DH1 Ant1 2402.152 2403.164 1.012 0.87 Pass NVN…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 37 of 38 7 Test Setup Photo Radiated Spurious Emission Below 1GHz Above 1GHz Report No: JYTSZB-R12-2101457 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2108017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 38 of 38 Conducted Emission 8 EUT Constructional Details Reference to the test report No.: JYTSZB-R12-2101454. ------End of report------

Contact Information

Applicant

Jerry Liu
[email protected]+86-0755-61803856Fax: 755-33979211

Test Firm

JianYan Testing Group Shenzhen Co., Ltd.Bruce Zhang
[email protected]+86 (0) 755 23118282

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.96 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device is approved for use in the handset described in this filing. End-users must be informed of the body-worn accessory operating requirements for satisfying RF exposure compliance.

Other Applications from INFINIX MOBILITY LIMITED

2AIZN-X1102D

Tablet

Sep 09, 2026

Equipment Class

PCB - PCS Licensed Transmitter
2AIZN-X6843

Mobile Phone

Sep 04, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AIZN-DONGLE

Infinix Space Max

Aug 14, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
2AIZN-XEH1LR

Wireless Over-Ear Headphones

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AIZN-XGC001-L

GT NX Controller

Jul 16, 2026

Equipment Class

JAB - Part 15 Class B Digital Device