FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. INFINIX MOBILITY LIMITED/
  3. 2AIZN-X6821

2AIZN-X6821Mobile Phone

INFINIX MOBILITY LIMITED
Mobile Phone - FCC ID 2AIZN-X6821 - INFINIX MOBILITY LIMITED
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jul 15, 2022
Application Purpose
Original Equipment
Date of Application
Jul 15, 2022
Equipment Note
Mobile Phone
Frequency Range
2545.00000000 - 2645.00000000
Company
INFINIX MOBILITY LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—
β†—

Test Report

β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—
β†—

Test Setup Photos

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Infinix X6821 User Manual (K) 1 Explosion diagram specification 1 CTP+LCM 6.66FHD 2 MI HOUSING 3 PCBA MB 4 CAM OIS 60M 5 SPK 6 FM 7 CAM AF 108M 8 CAM AF 13M 9 CAM FF 2M 10 COAXIAL CABLE SEAL MYLAR 11 R CAM DECO ASM 12 HEAT CON COPPER PIPE 13 UP FRAME ASM 14 R CAM LENS CH GLASS 15 SHIELD RADIATING COP FOILB 16 CARD HOLDER 17 R CAM CON FOAMS 108M 18 ELE RCV FILM 19 R CAM CON FOAMS 13M 20 CAM FRAME 2M 21 LCD SHIELD COP FOIL 22 VOLUME KEY 23 R CAM LENS 2M 24 ELE FP FOAM 25 POWER KEY SUPPORT FOAM 26 CAM FRAM CON FOAM 27 MC SCREW L2.5 28 BAT COVER ASM 29 B AT 30 FPC SIDE KEY 31 NFC 32 PCBA SUB 33 FP MYLAR 34 MOTOR LINEAR 35 COAXIAL CABLE 36 FPC MAIN 37 RCAM RUBBER 2M 38 DOWN FRAME ASM 39 FP FPC SUPPORT FOAM 40 EAR RUBBER 2 41 USB RUBBER 42 MOTOR CON FB 43 SPK SINGLE RADIATING FILM 44 SIDEKEY FRAME 45 TP RADIATING FILM 46 UP FRAME RADIATING FILM 47 MC SCREW L3.5 48 3 Know your phone 1. Front camera 2. Volume + key 3. Volume - key 4. Power key 5. NFC 2 SIM/SD card installation 1. P ower off mobile. 2. Refer to the following picture for SIM / SD card installation. 3 Charging the phone You can charge your device using a charger or by connecting it to the computer using a USB cable (comes with the phone). Use only INFINIX charger and cables. Other chargers or cables may damage the device. This will invalidate your phone warranty. 4 FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receive r. 5 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. SAR Information Statement Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radiofrequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. * Tests for SAR are conducted with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a 6 phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when tested for use at the ear is 0.707W/Kg and when worn on the body, as described in this user guide, is 0.606W/Kg (Body-worn measurements differ among phone models, depending upon available accessories and FCC requirements). The maximum scaled SAR in hotspot mode is 0.606W/Kg. While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RFexposure guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/ oet/fccid after searching on FCC ID: 2AIZN-X6821 Additional information on Specific Absorption Rates (SAR) can be found on the Cellular Telecommunications Industry Asso-ciation (CTIA) web-site at http://www.wow-com.com. * In the United States and Canada, the SAR limit for mobile phones used by the public is 1.6 watts/kg (W/kg) averaged over one gram of tissue. The standard incorporates a sub-stantial margin of safety to give additional protection for the public and to account for any variations in measurements. 7 Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 10mm must be maint…

Text truncated - open the document above for the full version.

Cover Letter(s)

INFINIX MOBILITY LIMITED DATE :2022-7-7 Equipment Autorisation Division Federal Communications Commission 7345 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AIZN-X6821 Product Name: Mobile Phone Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: β€’ Schematics β€’ Block diagram β€’ Operation description β€’ Tune up β€’ BOM These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 2022-7-7 By: Yiting Luo Signature Printed Title: Manager On behalf of : INFINIX MOBILITY LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

INFINIX MOBILITY LIMITED Date: 2022-7-7 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC.to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, Dated this 2022-7-7 By: Yiting Luo Signature Printed Title: Manager On behalf of : INFINIX MOBILITY LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

INFINIX MOBILITY LIMITED DATE:2022-7-7 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act asAgent On our behalf, I appoint JianYan Testing Group Shenzhen Co., Ltd.; No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Communit y,Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China.οΌ›Bruce.Zhang , to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with INFINIX MOBILITY LIMITED/ ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL Hong Kong Dated this 2022-7-7 By: Yiting Luo Signature Printed Title: Manager On behalf of : INFINIX MOBILITY LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

INFINIX MOBILITY LIMITED DATE :2022-7-7 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AIZN-X6821 Product Name: Mobile Phone Request for Short-Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.:  Test Setup Photos  External Photos  Internal Photos  User Manual The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. <Signature> Name Yiting Luo Title manager Company INFINIX MOBILITY LIMITED

External Photos

JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 1 of 4 EUT External Photos JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 4 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 4 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 4 of 4 ------End------

ID Label/Location Info

label location label location

Internal Photos

JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 1 of 7 EUT Internal Photos JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 7 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 7 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 4 of 7 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 5 of 7 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 6 of 7 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 7 of 7 ------End------

RF Exposure Info

JianYan Testing Group Shenzhen Co., Ltd. Report No.: JYTSZ-R14-2200127 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC SAR REPORT Applicant: INFINIX MOBILITY LIMITED Address of Applicant: FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL CENTRE 31- 35 SHAN MEI STREET FOTAN NT HONGKONG Equipment Under Test (EUT) Product Name: Mobile Phone Model No.: X6821 Trade mark Infinix FCC ID: 2AIZN-X6821 Applicable standards: FCC 47 CFR Part 2.1093 Date of Test: 14 Jun., 2022 ~ 23 Jun., 2022 Test Result: Maximum Reported 1-g SAR (W/kg) Head: 0.707 Body: 0.606 Hotspot: 0.606 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 2 of 172 2 Version Version No. Date Description 00 14 Jul., 2022 Original Tested by: Date: 14 Jul., 2022 Test Engineer Reviewed by: Date: 14 Jul., 2022 Project Engineer Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 3 of 172 3 Contents 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 SAR RESULTS SUMMARY ................................................................................................................................. 5 5 GENERAL INFORMATION .................................................................................................................................. 7 5.1 CLIENT INFORMATION ..................................................................................................................................................................... 7 5.2 GENERAL DESCRIPTION OF EUT ................................................................................................................................................... 7 5.3 MAXIMUM RF OUTPUT POWER ...................................................................................................................................................... 9 5.4 ENVIRONMENT OF TEST SITE ....................................................................................................................................................... 10 5.5 TEST SAMPLE PLAN ..................................................................................................................................................................... 10 5.6 TEST LOCATION ........................................................................................................................................................................... 10 6 INTRODUCTION ................................................................................................................................................. 11 6.1 INTRODUCTION ............................................................................................................................................................................. 11 6.2 SAR DEFINITION .......................................................................................................................................................................... 11 7 RF EXPOSURE LIMITS ..................................................................................................................................... 12 7.1 UNCONTROLLED ENVIRONMENT ................................................................................................................................................... 12 7.2 CONTROLLED ENVIRONMENT ....................................................................................................................................................... 12 7.3 RF EXPOSURE LIMITS .................................................................................................................................................................. 12 8 SAR MEASUREMENT SYSTEM ....................................................................................................................... 13 8.1 E-FIELD PROBE............................................................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 117 of 172 Appendix C: System Calibration Certificate Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 118 of 172 Calibration information for E-field probes Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 119 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 120 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 121 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 122 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 123 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 124 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 125 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 126 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 127 of 172 Calibration information for Dipole Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 128 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 129 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 130 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 131 of 172 Report No.: JYTSZ-R14-2200127 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2206018 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 132 of 172 Report No.: JYTSZ-R14-2…

Text truncated - open the document above for the full version.

Test Report

JianYan Testing Group Shenzhen Co., Ltd. Report No.: JYTSZ-R12-2201171 This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in above the application standard version. Test results reported herein relate only to the item(s) tested. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1. Cover Page FCC RF Test Report (GSM) Applicant: INFINIX MOBILITY LIMITED Address of Applicant: FLAT 39 8/F BLOCK D WAH LOK INDUSTRIAL CENTRE 31- 35 SHAN MEI STREET FOTAN NT HONGKONG Equipment Under Test (EUT) Product Name: Mobile Phone Model No.: X6821 Trade Mark: Infinix FCC ID: 2AIZN-X6821 Applicable Standards: FCC CFR Title 47 Part 2, 22H, 24E Date of Sample Receipt: 09 Jun., 2022 Date of Test: 10 Jun., to 12 Jul., 2022 Date of Report Issued: 13 Jul., 2022 Test Result: PASS Tested by: Date: 13 Jul., 2022 Test Engineer Reviewed by: Date: 13 Jul., 2022 Project Engineer Approved by: Date: 13 Jul., 2022 Manager Report No.: JYTSZ-R12-2201171 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-150-C Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 13 2. Version Version No. Date Description 00 13 Jul., 2022 Original Report No.: JYTSZ-R12-2201171 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-150-C Project No.: JYTSZR2206017 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 13 3. Contents Page 1. Cover Page .......................................................................................................................................................... 1 2. Version ................................................................................................................................................................. 2 3. Contents ............................................................................................................................................................... 3 4. General Information .......................................................................................................................................... 4 4.1 Client Information ................................................................................................................................................ 4 4.2 General Description of E.U.T. ........................................................................................................................... 4 4.3 Test Mode and Environment ............................................................................................................................. 5 4.4 Description of Test Auxiliary Equipment .......................................................................................................... 5 4.5 Measurement Uncertainty .................................................................................................................................. 5 4.6 Additions to, Deviations, or Exclusions from the Method .............................................................................. 5 4.7 Laboratory Facility ............................................................................................................................................... 5 4.8 Laboratory Location ............................................................................................................................................ 6 4.9 Test Instruments List .............................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jerry Liu
[email protected]+86-0755-61803856Fax: 755-33979211

Test Firm

JianYan Testing Group Shenzhen Co., Ltd.Bruce Zhang
[email protected]+86 (0) 755 23118282

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
22272.54 GHz - 2.65 GHz256.40 mW18M0G7D0.01 ppm
Confidentiality
Long Term
Grant Notes
Output Power is EIRP and ERP for above and below 1 GHz, respectively. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.71 W/kg, 0.61 W/kg, 0.61 W/kg, and 0.76 W/kg, respectively. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.

Other Applications from INFINIX MOBILITY LIMITED

2AIZN-X1102D

Tablet

Sep 09, 2026

Equipment Class

PCB - PCS Licensed Transmitter
2AIZN-X6843

Mobile Phone

Sep 04, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AIZN-DONGLE

Infinix Space Max

Aug 14, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
2AIZN-XEH1LR

Wireless Over-Ear Headphones

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AIZN-XGC001-L

GT NX Controller

Jul 16, 2026

Equipment Class

JAB - Part 15 Class B Digital Device