FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. LC Future Center/
  3. 2AJN7-TP00152A

2AJN7-TP00152ANotebook Computer

LC Future Center

Application Details

Equipment Class
CBE - Citizens Band End User Devices
Date of Grant
Mar 18, 2024
Application Purpose
Original Equipment
Date of Application
Feb 22, 2024
Equipment Note
Notebook Computer
Frequency Range
3565.02000000 - 3684.99000000
Company
LC Future Center
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

-------------- ----------------------------- Lenovo US 8001 Development Drive Morrisville, NC 27560 United States Date: 12/05/2023 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Certification designating a U.S. agent for service of process pursuant to Part 2.911(d)(7) To whom it may concern, [ LC Future Center ] and FCC Grantee code:[2AJN7 ] , FRN [ 0025849167 ] (“the applicant”) certifies that, as of the date of the filing of application, [Lenovo (United States) Incorporated] (“the agent”) is designated as the U.S. agent for the purpose of accepting service of process on behalf of the applicant for Lenovo branded products. The physical U.S. address and email for the designated agent are: Physical U.S. address: [8001 Development Drive, Morrisville, NC 27560, United States] FRN: 0012799359 Email: [[email protected]] The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The agent accepts the designation by (the applicant) as the U.S. agent to accept service of process includes, but is not limited to, delivery of any correspondence, notices, orders, decisions, and requirements of administrative, legal, or judicial process related to Commission proceedings. Signed by the Applicant Signed by the Agent (if different from the Applicant) Signature of Grantee Contact named below Name: Allen Chen Name: Brian Killebrew Title: Certification PM Address: 7F., No.780, Beian Rd., Zhongshan Dist., Taipei 104, Taiwan Title: Director, Corporate Regulatory Compliance, Standards and ISO 9001 Email: [email protected] Email: [email protected]

Attestation Statements

LC Future Center 7F., No.780, Beian Rd., Zhongshan Dist. Taipei 104, Taiwan Tel: 886-2-2718-8555; Fax: 886-2-2532-3719 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Date: January 15, 2024 Subject: Certifications concerning “covered” equipment pursuant to Part 2.911(d)(5)(i) and (ii) To whom it may concern, LC Future Center (“the applicant”) certifies that the equipment FCC ID: 2AJN7-TP00152A for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. LC Future Center (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, ________________________ Allen Chen Design Leader [email protected]

Attestation Statements

LC Future Center 7F., No.780, Beian Rd., Zhongshan Dist. Taipei 104, Taiwan Tel: 886-2-2718-8555; Fax: 886-2-2532-3719 FCC Agent Authorization Date: January 15, 2024 To whom it may concern, LC Future Center hereby authorize Sporton International Inc. to act on our behalf in all matters relating to applications for FCC equipment authorization, including the signing of all documents relating to these matters. Any and all acts carried out by Sporton International Inc. on our behalf shall have the same effect as acts of our own. We also hereby certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to section 5301 of the Anti-Drug Abuse Act of 1988. 21 U.S.C. 862. This authorization is limited to the product of as following: FCC ID: 2AJN7-TP00152A This authorization is valid until further written notice from LC Future Center Sincerely, ________________________ Allen Chen Design Leader [email protected]

Cover Letter(s)

LC Future Center 7F., No.780, Beian Rd., Zhongshan Dist. Taipei 104, Taiwan Tel: 886-2-2718-8555; Fax: 886-2-2532-3719 Date: January 15, 2024 FCC Laboratory 7435 Oakland Mills Rd Columbia MD 21046 Subject: Request for Confidentiality FCC ID: 2AJN7-TP00152A To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following documents from public disclosure indefinitely.  Schematic Diagram  Block Diagram  Part List  Operational Description  Tune-up Procedure Above mentioned documents which contain detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we are requesting the Commission to withhold the following documents for 180 days after the grant of equipment authorization is issued:  External Photos  Internal Photos  Test Setup Photos  User Manual It is our understanding that all measurement test reports, FCC ID label format cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, _______________________ Allen Chen Design Leader [email protected]

ID Label/Location Info

Section 8. Host PC labeling The description of the regulatory information is secured and the users cannot modify it. <E-label screen> To access the E-label screen, do one of the following:  Restart the computer. When the logo screen is displayed, press F9. The E-label screen is displayed.  Restart the computer. When the logo screen is displayed, press Enter or tap the prompt to enter the Startup Interrupt menu. Then press F9 or tap the Regulatory Information option. The E-label screen is displayed. For RM520N-GL, AX211D2W and NFC M/N: TP00152A FCC ID: 2AJN7-TP00152A, IC: 21863-TP00152A Contains FCC ID: PD9AX211D2, IC: 1000M-AX211D2 Contains FCC ID: MCLT77H747, IC: 2878D-T77H747 For RM520N-GL, BE200D2W and NFC M/N: TP00152A FCC ID: 2AJN7-TP00152A, IC: 21863-TP00152A Contains FCC ID: PD9BE200D2, IC: 1000M-BE200D2 Contains FCC ID: MCLT77H747, IC: 2878D-T77H747

ID Label/Location Info

Section 8. Host PC labeling The description of the regulatory information is secured and the users cannot modify it. <E-label screen> To access the E-label screen, do one of the following:  Restart the computer. When the logo screen is displayed, press F9. The E-label screen is displayed.  Restart the computer. When the logo screen is displayed, press Enter or tap the prompt to enter the Startup Interrupt menu. Then press F9 or tap the Regulatory Information option. The E-label screen is displayed. For RM520N-GL and QCNCM825 M/N: TP00152B FCC ID: 2AJN7-TP00152A, IC: 21863-TP00152A

RF Exposure Info

TEL : 886-3-327-3456 Page 1 of 72 FAX : 886-3-328-4978 Issued Date : Feb. 01, 2024 Template version: 211220 FCC SAR TEST REPORT Report No. : FA3N2403 FCC SAR TEST REPORT FCC ID : 2AJN7-TP00152A Equipment : Notebook Computer Brand Name : Lenovo Model Name : TP00152A, TP00152B Applicant : LC Future Center Limited Taiwan Branch 7F., No.780, Beian Rd., Zhongshan Dist., Taipei 104, Taiwan Manufacturer : LCFC (HeFei) Electronics Technology Co., Ltd. No. 3188-1, Yungu Road (Hefei Export Processing Zone), Hefei Economics & Technology Development Area, Anhui, CHINA Standard : FCC 47 CFR Part 2 (2.1093) Equipment: Quectel RM520N-GL, Intel AX211D2W and Intel BE200D2W tested inside of Lenovo Notebook Computer. The product was received on Dec. 20, 2023 and testing was started from Dec. 30, 2023 and completed on Jan. 13, 2024. We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample provide by manufacturer and the test data has been evaluated in accordance with the test procedures given in 47 CFR Part 2.1093 and FCC KDB and has been pass the FCC requirement. The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Laboratory, the test report shall not be reproduced except in full. Sporton International Inc. Wensan Laboratory Approved by: Cona Huang / Deputy Manager TEL : 886-3-327-3456 Page 2 of 72 FAX : 886-3-328-4978 Issued Date : Feb. 01, 2024 Template version: 211220 FCC SAR TEST REPORT Report No. : FA3N2403 Table of Contents 1. Statement of Compliance ............................................................................................................................................. 4 2. Guidance Applied .......................................................................................................................................................... 4 3. Equipment Under Test (EUT) Information ................................................................................................................... 5 3.1 General Information ............................................................................................................................................... 5 3.2 General LTE SAR Test and Reporting Considerations ........................................................................................... 7 3.3 General 5G NR SAR Test and Reporting Considerations ..................................................................................... 11 4. Proximity Sensor Triggering Test ...............................................................................................................................14 5. RF Exposure Limits......................................................................................................................................................20 5.1 Uncontrolled Environment .....................................................................................................................................20 5.2 Controlled Environment .........................................................................................................................................20 6. Specific Absorption Rate (SAR) ..................................................................................................................................21 6.1 Introduction ...........................................................................................................................................................21 6.2 SAR Definition .......................................................................................................................................................21 7. System Description and Setup ...................................................................................................................................22 7.1 Test Site Location ..................................................................................................................................................22 7.2 E-Field Probe ........................................................................................................................................................23 7.3 Data Acquisition Electronics (DAE) .......................................................................................................................23 7.4 Phantom ................................................................................................................................................................24 7.5 Device Holder........................................................................................................................................................25 8. Measurement Procedures ...........................................................................................................................................26 8.1 Spatial Peak SAR Evaluation ................................................................................................................................26 8.2 Power Reference Measurement............................................................................................................................27 8.3 Area Scan .............................................................................................................................................................27 8.4 Zoom Scan ............................................................................................................................................................28 8.5 Volume Scan Procedures ......................................................................................................................................28 8.6 Power Drift Monitoring ...........................................................................................................................................28 9. Test Equipment List .............................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Date: 2023-12-30 System Check_Head_750MHz DUT: D750V3 - SN1107 Communication System: CW; Frequency: 750.000 MHz; Duty Cycle: 1:1 Medium: HSL_750_231230 Medium parameters used: f= 750.000 MHz; σ= 0.906 S/m; ε r = 42.1 Ambient Temperature: 23.3°C; Liquid Temperature: 22.3°C DASY6 Configuration: - Probe: EX3DV4 - SN7694; ConvF(9.84, 9.84, 9.84); Calibrated: 2023-10-26 - Sensor-Surface: 1.4 mm - Electronics: DAE4ip Sn1800; Calibrated: 2023-05-31 - Phantom: ELI V8.0 (20deg probe tilt); Serial: 2204; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.421 W/kg; SAR (10g) = 0.281 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.02 dB SAR (1g) = 0.423 W/kg; SAR (8g) = 0.295 W/kg; SAR (10g) = 0.280 W/kg Smallest distance from peaks to all points 3 dB below = > 15.0 mm Ratio of SAR at M2 to SAR at M1 = 84.1 % Date: 2024-01-09 System Check_Head_750MHz DUT: D750V3 - SN1107 Communication System: CW; Frequency: 750.000 MHz; Duty Cycle: 1:1 Medium: HSL_750_240109 Medium parameters used: f= 750.000 MHz; σ= 0.885 S/m; ε r = 41.7 Ambient Temperature: 23.6°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(9.21, 8.99, 9.25); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.407 W/kg; SAR (10g) = 0.270 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = 0.03 dB SAR (1g) = 0.412 W/kg; SAR (8g) = 0.287 W/kg; SAR (10g) = 0.272 W/kg Smallest distance from peaks to all points 3 dB below = > 15.0 mm Ratio of SAR at M2 to SAR at M1 = 84.9 % Date: 2024-01-11 System Check_Head_750MHz DUT: D750V3-1107 Communication System: CW; Frequency: 750.000 MHz; Duty Cycle: 1:1 Medium: HSL_750_240111 Medium parameters used: f= 750.000 MHz; σ= 0.885 S/m; ε r = 43.0 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7791; ConvF(8.85, 9.89, 8.98); Calibrated: 2023-02-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1424; Calibrated: 2023-12-07 - Phantom: ELI V8.0 (20deg probe tilt); Serial: 2055; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.404 W/kg; SAR (10g) = 0.270 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = 0.00 dB SAR (1g) = 0.405 W/kg; SAR (8g) = 0.282 W/kg; SAR (10g) = 0.268 W/kg Smallest distance from peaks to all points 3 dB below = > 15.0 mm Ratio of SAR at M2 to SAR at M1 = 87.0 % Date: 2023-12-30 System Check_Head_850MHz DUT: D835V2 - SN4d167 Communication System: CW; Frequency: 835.000 MHz; Duty Cycle: 1:1 Medium: HSL_850_231230 Medium parameters used: f= 835.000 MHz; σ= 0.942 S/m; ε r = 41.8 Ambient Temperature: 23.3°C; Liquid Temperature: 22.3°C DASY6 Configuration: - Probe: EX3DV4 - SN7694; ConvF(9.48, 9.48, 9.48); Calibrated: 2023-10-26 - Sensor-Surface: 1.4 mm - Electronics: DAE4ip Sn1800; Calibrated: 2023-05-31 - Phantom: ELI V8.0 (20deg probe tilt); Serial: 2204; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.486 W/kg; SAR (10g) = 0.322 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = 0.02 dB SAR (1g) = 0.485 W/kg; SAR (8g) = 0.338 W/kg; SAR (10g) = 0.321 W/kg Smallest distance from peaks to all points 3 dB below = 16.4 mm Ratio of SAR at M2 to SAR at M1 = 85.2 % Date: 2024-01-09 System Check_Head_835MHz DUT: D835V2 - SN4d167 Communication System: CW; Frequency: 835.000 MHz; Duty Cycle: 1:1 Medium: HSL_850_240109 Medium parameters used: f= 835.000 MHz; σ= 0.919 S/m; ε r = 41.4 Ambient Temperature: 23.6°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(9.14, 8.88, 9.24); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.455 W/kg; SAR (10g) = 0.300 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = 0.01 dB SAR (1g) = 0.461 W/kg; SAR (8g) = 0.322 W/kg; SAR (10g) = 0.305 W/kg Smallest distance from peaks to all points 3 dB below = 18.4 mm Ratio of SAR at M2 to SAR at M1 = 87.9 % Date: 2024-01-11 System Check_Head_835MHz DUT: D835V2-4d167 Communication System: CW; Frequency: 835.000 MHz; Duty Cycle: 1:1 Medium: HSL_850_240111 Medium parameters used: f= 835.000 MHz; σ= 0.915 S/m; ε r = 42.6 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7791; ConvF(8.73, 9.71, 8.75); Calibrated: 2023-02-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1424; Calibrated: 2023-12-07 - Phantom: ELI V8.0 (20deg probe tilt); Serial: 2055; Section: Flat - Measurement Software: 16.2.4.2524 - UID: CW Pin=17.0dBm/Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.477 W/kg; SAR (10g) = 0.314 W/kg; Pin=17.0dBm/Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.00 dB SAR (1g) = 0.479 W/kg; SAR (8g) = 0.331 W/kg; SAR (10g) = 0.313 W/kg Smallest distance from peaks to all points 3 dB below = 20.5 mm Ratio of SAR at M2 to SAR at M1 = 86.7 % Date: 2024-01-03 System Check_Head_1750MHz DUT: D1750V2 - SN1112 Communication System: CW; Frequency: 1750.000 MHz; Duty Cycle: 1:1 Medium: HSL_1750_240103 Medium parameters…

Text truncated - open the document above for the full version.

RF Exposure Info

Date: 2024-01-07 #01_WCDMA II_RMC 12.2Kbps_Bottom of Laptop_0mm_Ch9400 Communication System: UMTS-FDD ; Frequency: 1880.000 MHz; Duty Cycle: 1:1 Medium: HSL_1900_240107 Medium parameters used: f= 1880.000 MHz; σ= 1.37 S/m; ε r = 40.5 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(7.54, 7.35, 7.67); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: WCDMA, 10011-CAC Area Scan (90.0 mm x 120.0 mm): Measurement Grid: 15.0 mm x 15.0 mm SAR (1g) = 0.366 W/kg; SAR (10g) = 0.208 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.04 dB SAR (1g) = 0.415 W/kg; SAR (8g) = 0.238 W/kg; SAR (10g) = 0.219 W/kg Smallest distance from peaks to all points 3 dB below = 11.1 mm Ratio of SAR at M2 to SAR at M1 = 83.2 % Date: 2024-01-07 #02_WCDMA IV_RMC 12.2Kbps_Bottom of Laptop_0mm_Ch1413 Communication System: UMTS-FDD ; Frequency: 1732.600 MHz; Duty Cycle: 1:1 Medium: HSL_1750_240107 Medium parameters used: f= 1732.600 MHz; σ= 1.35 S/m; ε r = 40.8 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(7.86, 7.63, 7.94); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: WCDMA, 10011-CAC Area Scan (90.0 mm x 120.0 mm): Measurement Grid: 15.0 mm x 15.0 mm SAR (1g) = 0.741 W/kg; SAR (10g) = 0.431 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.00 dB SAR (1g) = 0.839 W/kg; SAR (8g) = 0.489 W/kg; SAR (10g) = 0.452 W/kg Smallest distance from peaks to all points 3 dB below = 11.4 mm Ratio of SAR at M2 to SAR at M1 = 82.9 % Date: 2024-01-09 #03_WCDMA V_RMC 12.2Kbps_Bottom of Laptop_0mm_Ch4182 Communication System: UMTS-FDD ; Frequency: 836.400 MHz; Duty Cycle: 1:1 Medium: HSL_850_240109 Medium parameters used: f= 836.400 MHz; σ= 0.919 S/m; ε r = 41.4 Ambient Temperature: 23.6°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(9.14, 8.88, 9.24); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: WCDMA, 10011-CAC Area Scan (90.0 mm x 120.0 mm): Measurement Grid: 15.0 mm x 15.0 mm SAR (1g) = 0.337 W/kg; SAR (10g) = 0.221 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.01 dB SAR (1g) = 0.363 W/kg; SAR (8g) = 0.225 W/kg; SAR (10g) = 0.211 W/kg Smallest distance from peaks to all points 3 dB below = 13.6 mm Ratio of SAR at M2 to SAR at M1 = 84.5 % Communication System: LTE-FDD; Frequency: 2560.000 MHz; Duty Cycle: 1:1 Medium: HSL_2600_240108 Medium parameters used: f= 2560.000 MHz; σ= 1.93 S/m; ε r = 39.1 Ambient Temperature: 23.5°C; Liquid Temperature: 22.5°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(7.1, 6.87, 7.24); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: LTE-FDD, 10169-CAF Area Scan (120.0 mm x 80.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 0.899 W/kg; SAR (10g) = 0.443 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.5 mm Power Drift = 0.03 dB SAR (1g) = 0.939 W/kg; SAR (8g) = 0.489 W/kg; SAR (10g) = 0.446 W/kg Smallest distance from peaks to all points 3 dB below = 9.5 mm Ratio of SAR at M2 to SAR at M1 = 81.2 % Date: 2024-01-08 #04_LTE Band 7_20M_QPSK_1_0_Bottom of Laptop_0mm_Ch21350 Date: 2024-01-09 #05_LTE Band 12_10M_QPSK_1_0_Bottom of Laptop_0mm_Ch23095 Communication System: LTE-FDD ; Frequency: 707.500 MHz; Duty Cycle: 1:1 Medium: HSL_750_240109 Medium parameters used: f= 707.500 MHz; σ= 0.874 S/m; ε r = 42.0 Ambient Temperature: 23.6°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(9.21, 8.99, 9.25); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: LTE-FDD, 10175-CAH Area Scan (90.0 mm x 120.0 mm): Measurement Grid: 15.0 mm x 15.0 mm SAR (1g) = 0.408 W/kg; SAR (10g) = 0.268 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.04 dB SAR (1g) = 0.459 W/kg; SAR (8g) = 0.295 W/kg; SAR (10g) = 0.277 W/kg Smallest distance from peaks to all points 3 dB below = 13.2 mm Ratio of SAR at M2 to SAR at M1 = 85.1 % Communication System: LTE-FDD; Frequency: 782.000 MHz; Duty Cycle: 1:1 Medium: HSL_750_240109 Medium parameters used: f= 782.000 MHz; σ= 0.898 S/m; ε r = 41.5 Ambient Temperature: 23.6°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7793; ConvF(9.21, 8.99, 9.25); Calibrated: 2023-03-08 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn376; Calibrated: 2023-09-14 - Phantom: ELI V8.0-I; Serial: 2196; Section: Flat - Measurement Software: 16.2.4.2524 - UID: LTE-FDD, 10175-CAH Area Scan (90.0 mm x 150.0 mm): Measurement Grid: 15.0 mm x 15.0 mm SAR (1g) = 0.358 W/kg; SAR (10g) = 0.233 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = 0.13 dB SAR (1g) = 0.385 W/kg; SAR (8g) = 0.241 W/kg; SAR (10g) = 0.225 W/kg Smallest distance from peaks to all points 3 dB below = 14.0 mm Ratio of SAR at M2 to SAR at M1 = 85.1 % Date: 2024-01-09 #06_LTE Band 13_10M_QPSK_1_0_Bottom of Laptop_0mm_Ch23230 Communication System: LTE-FDD; Frequency: 793.000 MHz; Duty Cycle: 1:1 Medium: HSL_750_240109 Medium parameters used: f= 793.000 MHz; σ= 0.902 S/m; ε r = 41.5 Ambient Temperature: 23.6°C; Liquid Te…

Text truncated - open the document above for the full version.

RF Exposure Info

SP ORTON INTERNATIONA L INC. T EL : 886-3-327-3456 F AX : 886 -3-3 28 -49 78 D750V3, serial no. 1107 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D750V3 – serial no. 1107 750MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 06.22.2022 (Cal. Report) -26.22555.101 -570.78 06.21.2023 (ex tended) -27.043-3.1255.002 -0.0991.8842 2.45498 T he return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D750 V3, serial no. 1107(Data of Measurement : 06.21.2023) 750MHz - Head SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 D835V2, serial no. 4d167 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D835V2 – serial no. 4d167 835MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 11.24.2022 (Cal. Report) -29.5 51.9 -2.8 11.23.2023 (extended) -28.4 3.73 51.5 -0.4 -3.7 -0.9 The return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D835 V2, serial no. 4d167 (Data of Measurement : 11.23.2023) 835MHz - Head SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 D1750V2, serial no. 1068 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D1750V2 – serial no. 1068 1750MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 11.21.2022 (Cal. Report) -29.916 51.686 2.7875 11.20.2023 (extended) -32.297 -8 50.595 1.09 2.4789 0.31 The return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D1750 V2, serial no. 1068 (Data of Measurement : 11.20.2023) 1750 MHz - Head SP ORTON INTERNATIONA L INC. T EL : 886-3-327-3456 F AX : 886 -3-3 28 -49 78 D1750V2, serial no. 1112 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D1750V2 – serial no. 1112 1750MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 06.22.2022 (Cal. Report) -37.29751.384 5.9661 06.21.2023 (ex tended) -36.6591.71 52.830 1.446 4.1453 -1.8208 T he return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978 <Dipole Verification Data> - D1750 V2, serial no. 1112(Data of Measurement : 06.21.2023) 1750MHz - Head SP ORTON INTERNATIONA L INC. T EL : 886-3-327-3456 F AX : 886 -3-3 28 -49 78 D1900V2, serial no. 5d185 Extended Dipole Calibrations If dipoles are verified in return loss (<-20dB, within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Justification of the extended calibration> D1900V2 – serial no. 5d185 1900MHZ Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 06.17.2022 (Cal. Report) -26.71652.666 3.9213 06.16.2023 (ex tended) -26.908-0.07253.715 1.049 3.9028 -0.0185 T he return loss is < -20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Allen Chen(Design Leader)
[email protected]886-2-2718-8555Fax: 886-2-2532-3719

Test Firm

SPORTON International Inc.Alex Chen
[email protected]+886-3-327-3456Fax: +886-3-327-0973

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
9963.57 GHz - 3.68 GHz124.20 mW27M8W7D0.1 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is EIRP. This device supports LTE of 5, 10, 15, and 20 MHz bandwidth modes for TDD LTE Band 48. 5GNR Sub 6GHz of 10, 20, 30, and 40 MHz bandwidth modes for TDD 5GNR n48. The highest reported SAR for body and simultaneous transmission exposure conditions are 1.10 W/kg and 1.20 W/kg, respectively.

Other Applications from LC Future Center

2AJN7-TP00172C

Notebook Computer

Aug 24, 2026

Equipment Class

CBE - Citizens Band End User Devices
2AJN7-TP00173A

Notebook Computer

May 28, 2026

Equipment Class

CBE - Citizens Band End User Devices
2AJN7-TP00172A

Notebook Computer

May 28, 2026

Equipment Class

PCB - PCS Licensed Transmitter
2AJN7-TP00176AL

Notebook Computer

May 07, 2026

Equipment Class

PCB - PCS Licensed Transmitter
2AJN7-TP00173AL

Notebook Computer

May 06, 2026

Equipment Class

CBE - Citizens Band End User Devices