2AJZP-D450C1Mobile Phone

Mason America, Inc.
Mobile Phone - FCC ID 2AJZP-D450C1 - Mason America, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 06, 2020
Application Purpose
Original Equipment
Date of Application
Aug 06, 2020
Equipment Note
Mobile Phone
Frequency Range
2412.00000000 - 2462.00000000
Company
Mason America, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

D450C1 STARTUP GUIDE GETTING STARTED Thank you for using Mason products. In this scope of this quick guide, we want to introduce to you some important basics and some precautions. TABLET OVERVIEW specification parameter ModelD450C1 HWversionPVT2.0  ManufacturerMason  HOW TO INSERT THE SIMCARD AND MEMORY CARD 1. Setting up SIM and SD card 1) To remove the card tray, insert the SIM eject PIN included with your device into the small hole next to the car tray 2) The SIM card tray will pop-up. Withdraw the SIM tray 3) Insert a SIM card or micro SD into the card tray with the SIM’s chip surface facing downwards 4) Insert the card tray back into your device in the correct orientation 2. Press and hold the power button during 3~5 second to turn power on . Notes: Mason is not responsible in case of damage caused by incorrect assembly or removal of cards or damage caused by using non-standard equipment. KEY FEATURES OF D450C1 Navigation bar: 1. Left button: Return to previous screen 2. Right button: Touch on to go Task manager 3. Home button: Touch on to go IDLE FCC Statement § 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. § 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. SAR Information This phone is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the United States. During SAR testing, this device was set to transmit at its highest certified power level in all tested frequency bands, and placed in positions that simulate RF exposure in usage against the head with no separation, and near the body with the separation of 10 mm. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. The exposure standard for wireless devices employing a unit of measurement is known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range. - English: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, an d (2) This device must accept any interference, including interference that may cause undesired ope ration of the device. - French: Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Cover Letter(s)

Mason America, Inc. Letter of Authorization Company: Mason America, Inc Address: 506 2nd Ave Suite 1400 Seattle Washington United States Product Name: Mobile phone Model Number: D450C1 FCC Identifier: 2AJZP-D450C1 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Jim Xiao Date: 2020/7/16 Title: CEO Signature of applicant:

Cover Letter(s)

Mason America, Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020/07/28 Subject; Request for Confidentiality FCC ID: 2AJZP-D450C1 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Bom List Tune up procedure NII Software Security In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Jim Xiao Title: Manager

External Photos

External Photo

Internal Photos

Internal Photo WWAN ANT BT/WIFI/GPS ANT LTE Sub ANT NFC ANT

RF Exposure Info

Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 1 / 41 Appendix A: SAR System performance Check Plots Measurement Liquid Frequency Test Date System Check Head 750 2020-05-13 System Check Body 750 2020-05-13 System Check Head 835 2020-05-14 System Check Body 835 2020-05-14 System Check Head 1800 2020-05-16 System Check Body 1800 2020-05-16 System Check Head 1900 2020-05-17 System Check Body 1900 2020-05-17 System Check Head 2450 2020-05-18 System Check Body 2450 2020-05-18 System Check Head 2600 2020-05-18 System Check Body 2600 2020-05-18 System Check Head 5200 2020-05-19 System Check Body 5200 2020-05-19 System Check Head 5400 2020-05-19 System Check Body 5400 2020-05-19 System Check Head 5600 2020-05-19 System Check Body 5600 2020-05-19 System Check Head 5800 2020-05-19 System Check Body 5800 2020-05-19 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 2 / 41 System Performance Check (Head, 750MHz) Type: Phone measurement Area scan resolution: dx=8mm,dy=8mm Zoom scan resolution: dx=8mm, dy=8mm, dz=5mm Date of measurement: 05/13/2020 Measurement duration: 22 minutes 09 seconds A. Experimental conditions. Phantom File dx=8mm dy=8mm Phantom 5x5x7,dx=8mm dy=8mm dz=5mm Device Position Dipole Band 750MHz Channels Signal CW B. SAR Measurement Results Band SAR E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 750 Relative permittivity (real part) 41.87 Relative permittivity 21.60 Conductivity (S/m) 0.90 Power drift (%) -1.33 Ambient Temperature: 22.2°C Liquid Temperature: 22.6°C ConvF: 1.54 Crest factor: 1:1 SURFACE SAR VOLUME SAR Maximum location: X=-2.00, Y=-12.00 SAR Peak: 0.11 W/kg SAR 10g (W/Kg) 0.057736 SAR 1g (W/Kg) 0.080363 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 3 / 41 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.1648 0.0816 0.0538 0.0461 0.0309 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 4 / 41 System Performance Check (Body, 750MHz) Type: Phone measurement Area scan resolution: dx=8mm,dy=8mm Zoom scan resolution: dx=8mm, dy=8mm, dz=5mm Date of measurement: 05/13/2020 Measurement duration: 22 minutes 03 seconds A. Experimental conditions. Phantom File dx=8mm dy=8mm Phantom 5x5x7,dx=8mm dy=8mm dz=5mm Device Position Dipole Band 750MHz Channels Signal CW B. SAR Measurement Results Band SAR E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 750 Relative permittivity (real part) 55.49 Relative permittivity 22.80 Conductivity (S/m) 0.95 Power drift (%) -1.50 Ambient Temperature: 22.2°C Liquid Temperature: 22.6°C ConvF: 1.59 Crest factor: 1:1 SURFACE SAR VOLUME SAR Maximum location: X=-8.00, Y=-9.00 SAR Peak: 0.12 W/kg SAR 10g (W/Kg) 0.062943 SAR 1g (W/Kg) 0.091060 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 5 / 41 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.1227 0.0948 0.0688 0.0506 0.0380 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 6 / 41 System Performance Check (Head, 835MHz) Type: Phone measurement Area scan resolution: dx=8mm,dy=8mm Zoom scan resolution: dx=8mm, dy=8mm, dz=5mm Date of measurement: 05/14/2020 Measurement duration: 22 minutes 06 seconds A. Experimental conditions. Phantom File dx=8mm dy=8mm Phantom 5x5x7,dx=8mm dy=8mm dz=5mm Device Position Dipole Band 835MHz Channels Signal CW B. SAR Measurement Results Band SAR E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 835 Relative permittivity (real part) 41.53 Relative permittivity 19.48 Conductivity (S/m) 0.92 Power drift (%) -2.66 Ambient Temperature: 22.2°C Liquid Temperature: 22.6°C ConvF: 1.92 Crest factor: 1:1 SURFACE SAR VOLUME SAR Maximum location: X=-2.00, Y=-16.00 SAR Peak: 0.14 W/kg SAR 10g (W/Kg) 0.065465 SAR 1g (W/Kg) 0.098655 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 7 / 41 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.1346 0.1036 0.0740 0.0526 0.0371 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 8 / 41 System Performance Check (Body, 835MHz) Type: Phone measurement Area scan resolution: dx=8mm,dy=8mm Zoom scan resolution: dx=8mm, dy=8mm, dz=5mm Date of measurement: 05/14/2020 Measurement duration: 22 minutes 04 seconds A. Experimental conditions. Phantom File dx=8mm dy=8mm Phantom 5x5x7,dx=8mm dy=8mm dz=5mm Device Position Dipole Band 835MHz Channels Signal CW B. SAR Measurement Results Band SAR E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 835 Relative permittivity (real part) 55.20 Relative permittivity 20.91 Conductivity (S/m) 0.97 Power drift (%) -2.52 Ambient Temperature: 22.2°C Liquid Temperature: 22.6°C ConvF: 1.99 Crest factor: 1:1 SURFACE SAR VOLUME SAR Maximum location: X=-1.00, Y=-25.00 SAR Peak: 0.14 W/kg SAR 10g (W/Kg) 0.070150 SAR 1g (W/Kg) 0.103740 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 9 / 41 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.2714 0.1059 0.0600 0.0535 0.0292 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 10 / 41 System Performance Check (Head, 1800MHz) Type: Validation measurement Area scan resolution: dx=8mm,dy=8mm Zoom scan resolution: dx=8mm, dy=8mm, dz=5mm Date of measurement: 05/16/2020 Measurement duration: 22 minutes 07 seconds A. Experimental conditions. Phantom File dx=8mm dy=8mm Phantom 5x5x7,dx=8mm dy=8mm dz=5mm Device Position Dipole Band 1800MHz Channels Signal CW B. SAR Measurement Results Band SAR E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 1800 Relative permittivity (real part) 40.51 Relative permittivity 14.10 Conductivity (S/m) 1.41 Power Drift (%) -0.50 Ambient Temperature: 22.1°C Liquid Temperature: 22.6°C ConvF: 2.14 Duty factor: 1:1 SURFACE SAR VOLUME SAR Maximum location: X=-10.00, Y=-13.00 SAR Peak: 0.67 W/kg SAR 10g (W/Kg) 0.217404 SAR 1g (W/Kg) 0.405953 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 11 / 41 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.6728 0.4334 0.2463 0.1439 0.0907 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 12 / 41…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 1 / 61 Appendix B: SAR Measurement results Plots Plot Frequency/Mode Testing Position and Channel Test Date 1 WCDMA1900 Right Cheek Middle 2020/05/17 2 WCDMA1900 Body Back, Middle ,10mm 2020/05/17 3 WCDMA1700 Right Cheek Middle 2020/05/16 4 WCDMA1700 Body Back, Middle ,10mm 2020/05/16 5 WCDMA850 Right Cheek Middle 2020/05/14 6 WCDMA850 Body Back, Middle ,10mm 2020/05/14 7 LTE Band2 Right Cheek Middle 2020/05/17 8 LTE Band2 Body Back, Middle ,10mm 2020/05/17 9 LTE Band4 Right Cheek Middle 2020/05/16 10 LTE Band4 Body Back, Middle ,10mm 2020/05/16 11 LTE Band5 Right Cheek Middle 2020/05/14 12 LTE Band5 Body Back, Middle ,10mm 2020/05/14 13 LTE Band7 Left Cheek Middle 2020/05/18 14 LTE Band7 Body Face, Middle ,10mm 2020/05/18 15 LTE Band7 Edge C, Middle ,10mm 2020/05/18 16 LTE Band12 Left Cheek Middle 2020/05/13 17 LTE Band12 Body Back, Middle ,10mm 2020/05/13 18 LTE Band17 Right Cheek Middle 2020/05/13 19 LTE Band17 Body Back, Middle ,10mm 2020/05/13 20 LTE Band41 Left Cheek Middle 2020/05/18 21 LTE Band41 Body Face, Middle ,10mm 2020/05/18 22 LTE Band41 Edge C, Middle ,10mm 2020/05/18 23 LTE Band66 Right Cheek Middle 2020/05/16 24 LTE Band66 Body Back, Middle ,10mm 2020/05/16 25 WIFI 2.4G 802.11b Left Cheek Middle 2020/05/18 26 WIFI 2.4G 802.11b Body Back, Middle ,10mm 2020/05/18 27 WIFI 5G 802.11a Left Cheek Middle 2020/05/19 28 WIFI 5G 802.11a Body Back, Middle ,10mm 2020/05/19 29 BT Left Cheek Middle 2020/05/18 30 BT Body Back, Middle ,10mm 2020/05/18 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 2 / 61 Plot 1: WCDMA1900, Right Cheek, Middle Type: Phone measurement Date of measurement: 05/17/2020 Measurement duration: 22 minutes 14 seconds Mobile Phone IMEI number: -- A. Experimental conditions. Area Scan dx=8mm dy=8mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Right Cheek Band Band2_WCDMA1900 Channels 9400 Signal WCDMA (Duty cycle: 1:1) B. SAR Measurement Results E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 1880 Relative permittivity (real part) 40.48 Relative permittivity (imaginary part) 13.26 Conductivity (S/m) 1.40 Variation (%) -3.90 ConvF: 2.03 SURFACE SAR VOLUME SAR Maximum location: X=-46.00, Y=-51.00 SAR Peak: 0.28W/kg SAR 10g (W/Kg) 0.120688 SAR 1g (W/Kg) 0.194050 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 3 / 61 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.2745 0.2049 0.1407 0.0961 0.0655 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 4 / 61 Plot 2: WCDMA1900, Back, Middle,10mm Type: Phone measurement Date of measurement: 05/17/2020 Measurement duration: 22 minutes 11 seconds Mobile Phone IMEI number: -- A. Experimental conditions. Area Scan dx=8mm dy=8mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Back Band Band2_WCDMA1900 Channels 9400 Signal WCDMA (Duty cycle: 1:1) B. SAR Measurement Results E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 1880 Relative permittivity (real part) 53.29 Relative permittivity (imaginary part) 14.21 Conductivity (S/m) 1.50 Variation (%) -1.40 ConvF: 2.08 SURFACE SAR VOLUME SAR Maximum location: X=0.00, Y=-2.00 SAR Peak: 0.91W/kg SAR 10g (W/Kg) 0.270900 SAR 1g (W/Kg) 0.536875 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 5 / 61 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.9077 0.5908 0.3380 0.1950 0.1172 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 6 / 61 Plot 3: WCDMA1700, Right Cheek, Middle Type: Phone measurement Date of measurement: 05/16/2020 Measurement duration: 22 minutes 10 seconds Mobile Phone IMEI number: -- A. Experimental conditions. Area Scan dx=8mm dy=8mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Right Cheek Band Band2_WCDMA1700 Channels 1413 Signal WCDMA (Duty cycle: 1:1) B. SAR Measurement Results E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 1732.6 Relative permittivity (real part) 40.52 Relative permittivity (imaginary part) 14.10 Conductivity (S/m) 1.41 Variation (%) -1.12 ConvF: 2.14 SURFACE SAR VOLUME SAR Maximum location: X=-46.00, Y=-51.00 SAR Peak: 0.07W/kg SAR 10g (W/Kg) 0.029352 SAR 1g (W/Kg) 0.046302 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 7 / 61 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 0.0677 0.0470 0.0301 0.0203 0.0148 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 8 / 61 Plot 4: WCDMA1700, Back, Middle,10mm Type: Phone measurement Date of measurement: 05/16/2020 Measurement duration: 22 minutes 17 seconds Mobile Phone IMEI number: -- A. Experimental conditions. Area Scan dx=8mm dy=8mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Back Band Band2_WCDMA1700 Channels 1413 Signal WCDMA (Duty cycle: 1:1) B. SAR Measurement Results E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 1732.6 Relative permittivity (real part) 53.31 Relative permittivity (imaginary part) 15.40 Conductivity (S/m) 1.54 Variation (%) -1.19 ConvF: 2.22 SURFACE SAR VOLUME SAR Maximum location: X=1.00, Y=8.00 SAR Peak: 1.17W/kg SAR 10g (W/Kg) 0.389879 SAR 1g (W/Kg) 0.743396 Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 9 / 61 Z (mm) 0.00 4.00 9.00 14.00 19.00 SAR (W/Kg) 1.1665 0.8041 0.4958 0.3043 0.1880 3D screen shot Hot spot position Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) 10 / 61 Plot 5: WCDMA850, Right Cheek, Middle Type: Phone measurement Date of measurement: 05/14/2020 Measurement duration: 22 minutes 12 seconds Mobile Phone IMEI number: -- A. Experimental conditions. Area Scan dx=8mm dy=8mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Right Cheek Band Band5_WCDMA850 Channels 4183 Signal WCDMA (Duty cycle: 1:1) B. SAR Measurement Results E-Field Probe SATIMO SN_41/18_EPG0330 Frequency (MHz) 836.6 Relative permittivity (real part) 41.53 Relative permittivity (imaginary part) 19.48 Conductivity (S/m) 0…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No. SET2020-05992 ANNEX C: Calibration Reports EPGO 330 Probe Calibration Report SID750 Dipole Calibration Report SID835 Dipole Calibration Report SID1800 Dipole Calibration Report SID1900 Dipole Calibration Report SID2450 Dipole Calibration Report SID2600 Dipole Calibration Report SID5G Dipole Calibration Report Report No. SET2020-05992 EPGO330 Probe Calibration Report Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 SID750Dipole Calibration Report Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 SID835 Dipole Calibration Report Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 SID1800 Dipole Calibration Report Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 SID1900 Dipole Calibration Report Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992

RF Exposure Info

Report No. SET2020-05992 v Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 Report No. SET2020-05992 <Justification of the extended calibration> If dipoles are verified in return loss(<-20dB, within 20% of prior calibration),and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. Head 750MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -40.35 - 49.1 - 2019.11.26 -40.17 4.23 48.98 -0.12 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 750MHz Report No. SET2020-05992 Head 835MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -21.05 - 59.7 - 2019.11.26 -21.09 -0.93 59.74 0.04 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 835MHz Report No. SET2020-05992 Head 1800MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -21.94 - 44.7 - 2019.11.26 -21.48 11.17 44.12 -0.58 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 1800MHz Report No. SET2020-05992 Head 1900MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -24.08 - 51.2 - 2019.11.26 -24.07 0.23 54.29 3.09 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 1900MHz Report No. SET2020-05992 Head 2450MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -27.94 - 49.5 - 2019.11.26 -27.59 8.39 47.93 -1.57 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 2450MHz Report No. SET2020-05992 Head 2600MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -30.33 - 53.1 - 2019.11.26 -29.92 9.90 51.54 -1.56 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 2600MHz Report No. SET2020-05992 Head 5-6GHz Date of Measurement Frequency (MHz) Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 5200 -9.69 - 25.64 - 2017.11.27 5400 -10.98 - 84.04 - 2017.11.27 5600 -13.52 - 36.63 - 2017.11.27 5800 -13.34 - 47.82 - 2019.11.26 5200 -9.70 -0.23 27.66 2.02 2019.11.26 5400 -11.02 -0.93 84.54 0.50 2019.11.26 5600 -13.34 4.23 36.02 -0.61 2019.11.26 5800 -13.49 0.69 51.67 3.85 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 5-6GHz Report No. SET2020-05992 Body 750MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -27.32 - 46.8 - 2019.11.26 -27.28 0.93 46.60 -0.20 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 750MHz Report No. SET2020-05992 Body 835MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -25.17 - 55.1 - 2019.11.26 -25.25 -1.86 56.65 1.55 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 835MHz Report No. SET2020-05992 Body 1800MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -24.11 - 44.3 - 2019.11.26 -24.16 -1.15 43.81 -0.49 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 1800MHz Report No. SET2020-05992 Body 1900MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -22.17 - 46.8 - 2019.11.26 -21.90 6.41 50.56 3.76 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 1900MHz Report No. SET2020-05992 Body 2450MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -26.02 - 53.2 - 2019.11.26 -25.55 11.43 50.04 -3.16 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 2450MHz Report No. SET2020-05992 Body 2600MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 -33.55 - 49.4 - 2019.11.26 -33.56 -0.23 49.14 -0.26 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 2600MHz Report No. SET2020-05992 Body 5-6GHz Date of Measurement Frequency (MHz) Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.11.27 5200 -8.86 - 23.97 - 2017.11.27 5400 -9.91 - 92.64 - 2017.11.27 5600 -11.72 - 32.59 - 2017.11.27 5800 -11.90 - 48.49 - 2019.11.26 5200 -8.63 5.44 24.83 0.86 2019.11.26 5400 -10.31 -9.65 92…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) Page 1 of 69 FCC SAR TEST REPORT Report No.: SET2020-05992 Product: Mobile phone Tra d e Na me: MASON Model No.: D450C1 FCC ID: 2AJZP-D450C1 IC : 24360-D450C1 Applicant: Mason America, Inc. Address: 506 2nd Ave Suite 1400 Seattle Washington United States Issued by: CCIC Southern Testing Co., Ltd. Lab Location: Electronic Testing Building, No. 43 Shahe Road, Xili Street, Nanshan District, Shenzhen, Guangdong, China. Te l: 86 755 26627338 Fax:86 755 26627238 Mail: [email protected] Website:http://www.ccic-set.com This test report consists of 69 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CCIC-SET. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CCIC-SET within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Report No. SET2020-05992 CCIC-SET/TRF:ISAR(2019-05-23) Page 2 of 69 Te s t R e p o r t Product. ...................: Mobile phone Model No. .................: D450C1 Brand Name..............: MASON FCC ID....................: 2AJZP-D450C1 IC..........................: 24360-D450C1 Applicant.................: Mason America, Inc. Applicant Address.......: 506 2nd Ave Suite 1400 Seattle Washington United States Manufacturer............: Mason America, Inc. Manufacturer Address: 506 2nd Ave Suite 1400 Seattle Washington United States Test Standards..........: 47CFR §2.1093- Radiofrequency Radiation Exposure Evaluation: Portable Devices; ANSI C95.1–1992: Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz – 300 GHz.( IEEE Std C95.1-1991) RSS-102: Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)(Issue 5 of March 2015) IEEE 1528–2013: IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques IEC 62209-1:2016, Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) IEC 62209-2:2010, Human exposure to radio frequency fields from hand-held and body mounted wireless communication devices-Human models, instrumentation, and procedures -Part2:Procedure to determine the specific rate(SAR) for wireless communication devices used in close proximity to the human body(frequency range of 30MHz to 6GHz) Test Result...............: Pass Test Date..................: 2020.05.13-2020.05.19 Tested by ..............: 2020-08-03 Mei Chun, Test Engineer Reviewed by.............: 2020-08-03 Chris You, Senior Engin…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Anny Chung(Operations Manager,APAC)
[email protected]7607055516Fax: 8054915123

Technical Contact

Mason America, Inc.
[email protected]

United States

Test Firm

CCIC Southern Testing Co., LtdZhu Qi
[email protected]867552626067

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz46.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, hotspot and simultaneous transmission use conditions is 0.24W/kg, 0.07W/kg, 0.07W/kg and 1.16W/kg respectively.