  2. Shenzhen JBT Smart Lighting Co.,LTD/
  3. 2AKG3-OW104

2AKG3-OW104Smart Outdoor Wifi Plug

Shenzhen JBT Smart Lighting Co.,LTD
Smart Outdoor Wifi Plug - FCC ID 2AKG3-OW104 - Shenzhen JBT Smart Lighting Co.,LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 14, 2023
Application Purpose
Original Equipment
Date of Application
Jul 14, 2023
Equipment Note
Smart Outdoor Wifi Plug
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen JBT Smart Lighting Co.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Can’t connect? Need help? WE CAN HELP DO NOT RETURN THIS PRODUCT TO THE STORE support.merkurysmart.com or tap ‘support‘ for help in the Merkury Smart app. SMART OUTDOOR WI-FI PLUG START GUIDE Thank you for purchasing your MERKURY smart home product. Get started using your new devices by downloading Merkury Smart App, one convenient app that manages everything straight from your phone or tablet. Easily connect to your home Wi-Fi, and control multiple devices from the touch of your fingertips. 13 You can rename your devices in the Merkury Smart app, and Alexa will refer to them by the same name. So if you rename a smart strip to “Living Room“ or a nickname like “Blossom,“ then Alexa will use that same name later on. Alternatively, you can create an Alexa group, like “Bedroom“ or “Downstairs,“ and add the device to the group. Alexa will recognize the group name in the Alexa app, or the device name in the Merkury Smart app. Amazon Alexa 04 Choose “Discover Devices.“ After a few seconds your Merkury devices will be displayed under Smart Home in the Alexa app. 03 Authorize your account with Smart Home Skills using the username and password from your Merkury app. By signing in, you are authorizing Google to access your devices Email Address* Password* Sign In 12 To control your Merkury smart bulbs, plugs or surge protectors, just ask Alexa. Make sure your devices are already set up using the Merkury app. “Alexa, turn on the patio lights.“ “Alexa, turn off the garden lights.” *Some commands require compatible devices. Things you can say*: 01 02 Open the Alexa app and go to Skills in the menu. Search for Merkury Smart then tap Enable. Merkury Smart 01 02 02 02 03 05 Download & Register Plug In Connect (Bluetooth Discovery) Connect (Easy Mode) Connect (AP Mode) Questions, Troubleshooting, Notices Contents Start Guide 08 10 Google Assistant Amazon Alexa Voice Control Guide FCC Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 11 Google Assistant 04 Authorize your account with Google Assistant using the username and password from your Merkury Smart app. 03 Choose “Merkury Smart“ from the list of Home Control partners. Now your Google Home app and Merkury devices are linked! You’re now able to say “Hey Google“ and control your Merkury devices. At any time, go into the “Home Control“ section of the Google Home app to set nicknames and rooms for your devices. You can rename your devices in the Merkury Smart app, and Google Assistant will refer to them by the same name. So if you rename a smart bulb to “Living Room“ or a nickname like “Blossom,“ then Google Assistant will use that same name later on. You can always give it a nickname using the Google Home app as well. You can also assign bulbs to a specific room, like “Bedroom“ or “Kitchen.“ Google Assistant will be able to control devices by room.      By signing in, you are authorizing Google to access your devices /account.mymerkurysmart.com/ Email Address* Password* Sign In 10 To control your Merkury smart bulbs, plugs or surge protectors, just say “OK Google,“ or “Hey Google,“ and ask. Make sure your devices are already set up using the Merkury Smart app. “Hey Google, turn on all the patio light.“ “Hey Google, turn off the garden lights.” Things you can say*: *Some commands require compatible devices. 01 02 Open the Google Home app and go to Home Control in the menu. Tap the “+“ button. Important Information: Important Information: Before installing, read and follow all precautions, including the following: CAUTION: Suitable for indoor use only. DO NOT IMMERSE IN WATER. DO NOT EXCEED RATED CAPACITY. Support: If you encounter any issues, please contact us at support.merkurysmart.com for help. © 2023 Merkury Innovations • 45 Broadway 3rd FL, New York NY 10006. The illustrated product and specifications may differ slightly from those supplied. iPhone, Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google, Google Play, and related marks and logos are trademarks of Google LLC. iOS is a registered trademark of Cisco in the U.S. and other countries and is used under license. Amazon, Alexa and all related l…

Text truncated - open the document above for the full version.

Cover Letter(s)

Shenzhen JBT Smart Lighting Co., LTD Add: No.7 Building,No.1 Furong Road,Furong Industrial Park,Shajing Town,BaoanDistrict Shenzhen China Date: 2023-6-3 FCC ID: 2AKG3-OW104 Dear Sir/Madam, We, Shenzhen JBT Smart Lighting Co., LTD Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Smart Outdoor Wifi Plug Model no.: MI-OW104-101, MI-OW104-101P, MIC-OW104-101, MIC-OW104-101P, MI-OW204-101, MI-OW204-101P, MIC-OW204-101, MIC-OW204-101P, GN-OW104-101, GN-OW104-101P, GNC- OW104-101, GNC-OW104-101P, GN-OW204-101, GN-OW204-101P, GNC-OW204-101, GNC- OW204-101P, JBT-SMT-WFCZ-2301-1, JBT-SMT-WFCZ-2301-2 Sincerely, Name/Title: Jason Wang/Manager Company: Shenzhen JBT Smart Lighting Co., LTD Address: No.7 Building,No.1 Furong Road,Furong Industrial Park,Shajing Town,BaoanDistrict Shenzhen China Phone: 17508106923 Fax: 17508106923 E-Mail: [email protected]

External Photos

Test Report Number: BTF230628R00901 Appendix EUT Photos for BTF230628R00901 Test Report Number: BTF230628R00901 External Test Report Number: BTF230628R00901 Test Report Number: BTF230628R00901

ID Label/Location Info

________________________________________________________________________________ _________ LABEL AND LOCATION (Size: L2.0cm*W1.0cm) Material: Tagboard Glue: adhesive sticker Font color: Black Label color: White Smart Outdoor Wifi Plug MI-OW104-101 FCC ID: 2AKG3-OW104 Label Location

Internal Photos

Test Report Number: BTF230628R00901 Appendix EUT Photos for BTF230628R00901 Test Report Number: BTF230628R00901 Internal Test Report Number: BTF230628R00901 Test Report Number: BTF230628R00901 Antenna

RF Exposure Info

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 8 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Exposure Report For Applicant Name: Shenzhen JBT Smart Lighting Co., LTD Address: No.7 Building,No.1 Furong Road, Furong Industrial Park, Shajing Town, Baoan District, Shenzhen City China EUT Name: Smart Outdoor Wifi Plug Brand Name: N/A Model Number: MI-OW104-101 Series Model Number: Refer to section 2 Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF230628R00902 Test Standards: 47 CFR Part 2 Subpart J Section 2.1091 FCC ID: 2AKG3-OW104 Test Conclusion: Pass Test Date: 2023-06-21 to 2023-06-30 Date of Issue: 2023-07-11 Prepared By: Elma. Yang / Project Engineer Date: 2023-07-11 Approved By: Ryan CJ / EMC Manager Date: 2023-07-11 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF230628R00902 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 8 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 Jul. 11 th 2023 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF230628R00902 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 8 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1. Introduction ............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 2.5 Technical Information........................................................................................................................................................... 5 3. Test Requirement ................................................................................................................................................................................. 7 1.1 Assessment Result ............................................................................................................................................................... 7 Test Report Number: BTF230628R00902 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 4 of 8 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China 1. Introduction 1.1 Identification of Testing Laboratory Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Phone Number: +86-0755-23146130 Fax Number: +86-0755-23146130 1.2 Identification of the Responsible Testing Location Test Location: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Description: All measurement facilities used to collect the measurement data are located at F101,201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China FCC Registration Number: 518915 Designation Number: CN1330 1.3 Laboratory Condition Ambient Temperature: 20°C to 25°C Ambient Relative Humidity: 45% to 55% Ambient Pressure: 100 kPa to 102 kPa 1.4 Announcement (1) T…

Text truncated - open the document above for the full version.

Test Report

tυyd、 1. General Description CBU Antenna test rep01t EUT Name CBU Antenna Wireless type Antenna Type Dimensions BT/WIFI PCB antenna Appendix A 2. Technical Information e E nuu -- VJ m 一 - m R - - e - - u w 一一 叫 n E ’ r e -- F BEH E - - ,.‘ q -一 唱 e E E r -- 甲卜 EE -- 2402MHz ~ 2480MHz 2400,2410 ...... 2500MHz 3. Test Standards Identity IEEE 149-1979 Document Title IEEE Standard Test Procedures for Antennas

Test Report

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 78 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Test Report For Applicant Name: Shenzhen JBT Smart Lighting Co., LTD Address: No.7 Building, No.1 Furong Road, Furong Industrial Park, Shajing Town, Baoan District, Shenzhen City, China EUT Name: Smart Outdoor Wifi Plug Brand Name: N/A Model Number: MI-OW104-101 Series Model Number: Refer to section 2 Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF230628R00901 Test Standards: 47 CFR Part 15.247 Test Conclusion: Pass FCC ID: 2AKG3-OW104 Test Date: 2023-06-21 to 2023-06-30 Date of Issue: 2023-07-11 Prepared By: Elma. Yang / Project Engineer Date: 2023-07-11 Approved By: Ryan CJ/ EMC Manager Date: 2023-07-11 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF230628R00901 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 78 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2023-07-11 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF230628R00901 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 78 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1 INTRODUCTION ..........................................................................................................................................5 1.1 Identification of Testing Laboratory ...............................................................................................5 1.2 Identification of the Responsible Testing Location ......................................................................5 1.3 Announcement .................................................................................................................................5 2 PRODUCT INFORMATION ..........................................................................................................................6 2.1 Application Information ...................................................................................................................6 2.2 Manufacturer Information ................................................................................................................6 2.3 Factory Information .........................................................................................................................6 2.4 General Description of Equipment under Test (EUT) ...................................................................6 2.5 Technical Information ......................................................................................................................6 3 SUMMARY OF TEST RESULTS .................................................................................................................7 3.1 Test Standards ..................................................................................................................................7 3.2 Uncertainty of Test ...........................................................................................................................7 3.3 Summary of Test Result ..................................................................................................................7 4 TEST CONFIGURATION .............................................................................................................................8 4.1 Test Equipment List .........................................................................................................................8 4.2 Test Auxiliary Equipment ............................................................................................................. 12 4.3 Test Modes ..................................................................................................................................... 12 5 EVALUATION RESULTS (EVALUATION) ................................................................................................ 13 5.1 Antenna requirement .................................................................................................................... 13 5.1.1 Conclusion: .......................................................................................................................... 13 6 RADIO SPECTRUM MATTER TEST RESULTS (RF) .............................................................................. 14 6.1 Conducted Emission at AC power line ....................................................................................... 14 6.1.1 E.U.T. Operation: ................................................................................................................. 14 6.1.2 Test Setup Diagram: ............................................................................................................ 14 6.1.3 Test Data: ............................................................................................................................ 15 6.2 Occupied Bandwidth ...…

Text truncated - open the document above for the full version.

Test Report

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 50 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Test Report For Applicant Name: Shenzhen JBT Smart Lighting Co., LTD Address: No.7 Building, No.1 Furong Road, Furong Industrial Park, Shajing Town, Baoan District, Shenzhen City, China EUT Name: Smart Outdoor Wifi Plug Brand Name: N/A Model Number: MI-OW104-101 Series Model Number: Refer to section 2 Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF230628R00903 Test Standards: 47 CFR Part 15.247 Test Conclusion: Pass FCC ID: 2AKG3-OW104 Test Date: 2023-06-21 to 2023-06-30 Date of Issue: 2023-07-11 Prepared By: Elma. Yang / Project Engineer Date: 2023-07-11 Approved By: Ryan CJ/ EMC Manager Date: 2023-07-11 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF230628R00903 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 50 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2023-07-11 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF230628R00903 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 50 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1 INTRODUCTION ..........................................................................................................................................5 1.1 Identification of Testing Laboratory ...............................................................................................5 1.2 Identification of the Responsible Testing Location ......................................................................5 1.3 Announcement .................................................................................................................................5 2 PRODUCT INFORMATION ..........................................................................................................................6 2.1 Application Information ...................................................................................................................6 2.2 Manufacturer Information ................................................................................................................6 2.3 Factory Information .........................................................................................................................6 2.4 General Description of Equipment under Test (EUT) ...................................................................6 2.5 Technical Information ......................................................................................................................6 3 SUMMARY OF TEST RESULTS .................................................................................................................7 3.1 Test Standards ..................................................................................................................................7 3.2 Uncertainty of Test ...........................................................................................................................7 3.3 Summary of Test Result ..................................................................................................................7 4 TEST CONFIGURATION .............................................................................................................................8 4.1 Test Equipment List .........................................................................................................................8 4.2 Test Auxiliary Equipment ............................................................................................................. 12 4.3 Test Modes ..................................................................................................................................... 12 5 EVALUATION RESULTS (EVALUATION) ................................................................................................ 13 5.1 Antenna requirement .................................................................................................................... 13 5.1.1 Conclusion: .......................................................................................................................... 13 6 RADIO SPECTRUM MATTER TEST RESULTS (RF) .............................................................................. 14 6.1 Conducted Emission at AC power line ....................................................................................... 14 6.1.1 E.U.T. Operation: ................................................................................................................. 14 6.1.2 Test Setup Diagram: ............................................................................................................ 14 6.1.3 Test Data: ............................................................................................................................ 15 6.2 Occupied Bandwidth ...…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Report Number: BTF230628R00901 Appendix Setup Photos for BTF230628R00901 Test Report Number: BTF230628R00901 Conducted Emission at AC power line Band edge emissions (Radiated) Emissions in restricted frequency bands (above 1GHz) Test Report Number: BTF230628R00901 Emissions in restricted frequency bands (below 1GHz)

Contact Information

Applicant

Jason wang
[email protected]17508106923Fax: 17508106923

Test Firm

BTF Testing Lab (Shenzhen) Co., Ltd.Ryan CJ
[email protected]8675523146130

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz32.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen JBT Smart Lighting Co.,LTD

LED Down Light - FCC ID 2AKG3-US-DL6C-1 - Shenzhen JBT Smart Lighting Co.,LTD
2AKG3-US-DL6C-1

LED Down Light

Dec 11, 2022

Equipment Class

DTS - Digital Transmission System
LED Down Light - FCC ID 2AKG3-US-DL6B-1 - Shenzhen JBT Smart Lighting Co.,LTD
2AKG3-US-DL6B-1

LED Down Light

Dec 11, 2022

Equipment Class

DTS - Digital Transmission System
Control Box - FCC ID 2AKG3-EW020 - Shenzhen JBT Smart Lighting Co.,LTD
2AKG3-EW020

Control Box

Dec 08, 2022

Equipment Class

DTS - Digital Transmission System
smart lamp - FCC ID 2AKG3-EW018 - Shenzhen JBT Smart Lighting Co.,LTD
2AKG3-EW018

smart lamp

Jul 28, 2021

Equipment Class

DTS - Digital Transmission System
LED Strip - FCC ID 2AKG3-EW010 - Shenzhen JBT Smart Lighting Co.,LTD
2AKG3-EW010

LED Strip

Jul 25, 2021

Equipment Class

DTS - Digital Transmission System