FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hangzhou Jufeng Technology Co., Ltd./
  3. 2AKUR-PLAY01

2AKUR-PLAY01FPT Camera

Hangzhou Jufeng Technology Co., Ltd.
FPT Camera - FCC ID 2AKUR-PLAY01 - Hangzhou Jufeng Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 27, 2023
Application Purpose
Original Equipment
Date of Application
Jul 27, 2023
Equipment Note
FPT Camera
Frequency Range
2412.00000000 - 2462.00000000
Company
Hangzhou Jufeng Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PLAY fast user manual 1. Camera connect power supply. 2. After led light flash and pan move, use mobile wifi setup to search AP hotspot FC-xxxxxx, wifi password is the first 14 serial code. 3. Open APP(FunSDKDemo-FSSXM), follow below instructions step by step: open this app click here. Media function click here. Play live video click here. Device list(Lan) Choose this device and click . click here.Control device input password here.(iUPInRjUn) 4. Start live video. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party. Responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices). This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: The equipment complies with FCC Radiation exposure limits set forth for uncontrolled enviroment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. .

Attestation Statements

Hangzhou Jufeng Technology Co., Ltd. The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/28/2023 U.S. Agent Designation Hangzhou Jufeng Technology Co., Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AKUR-PLAY01): Name and company of U.S. agent: ACT Lab LLC Physical U.S. address of agent: 3280 East 59th Street Long Beach, CA 90805 United States FRN of U.S. agent: 0033465568 Email address of U.S. agent: [email protected] ACT Lab LLC acknowledges their obligation to accept service of process on behalf of Hangzhou Jufeng Technology Co., Ltd. Hangzhou Jufeng Technology Co., Ltd. with the FRN 0026154054 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature Fang Lai Manager Hangzhou Jufeng Technology Co., Ltd. Signature Mr Scott Huber Senior Technical Director ACT Lab LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V04

Attestation Statements

Hangzhou Jufeng Technology Co., Ltd. The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/27/2023 To whom it may concern: We, Hangzhou Jufeng Technology Co., Ltd. hereby certify that the equipment for which authorization is sought (FCC ID: 2AKUR-PLAY01) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). Sincerely, Signature Fang Lai Manager Hangzhou Jufeng Technology Co., Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V02

External Photos

FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 3 Appearance of EUT Photo 4 Appearance of EUT FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 5 Appearance of Adapter

ID Label/Location Info

FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Appendix IID Label Size for the label: 30mm X 30mm Appendix II ID Label Location FPT Camera FCC ID: 2AKUR-PLAY01 Model: FPT Camera Play This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Appendix IV EUT Internal Photographs Photo 6 Internal of EUT Photo 7 Internal of EUT FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 8 Internal of EUT Photo 9 Internal of EUT Antenna FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 10 Appearance of PCB Photo 11 Appearance of PCB FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 12 Appearance of PCB Photo 13 Appearance of PCB FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 14 Appearance of PCB Photo 15 Appearance of PCB FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 16 Appearance of PCB Photo 17 Appearance of PCB FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 18 Appearance of PCB Photo 19 Appearance of PCB FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 20 Appearance of PCB Photo 21 Appearance of PCB FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo 22 Appearance of PCB Photo 23 Appearance of PCB

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202305-0134-4 Page: 1 of 3 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Maximum Permissible Exposure Evaluation FCC ID: 2AKUR-PLAY01 1. Client Information Applicant : Hangzhou Jufeng Technology Co., Ltd. Address : Building 9, Yinhu Innovation Center, No.9 FuXian Road, YinHu Street, Hangzhou, China. Manufacturer : Hangzhou Jufeng Technology Co., Ltd. Address : Building 9, Yinhu Innovation Center, No.9 FuXian Road, YinHu Street, Hangzhou, China. 2. General Description of EUT EUT Name : FPT Camera Models No. : FPT Camera Play Model Different : ---- Product Description : Operation Frequency: 802.11b/g/n(HT20): 2412MHz~2462MHz 802.11n(HT40): 2422MHz~2452MHz Antenna Gain: 3.98dBi FPC Antenna Power Rating : Adapter (SA0101-0502000UA) Input: 100-240V~ 50/60Hz 0.35A Max Output: 5.0V2.0A, 10.0W Software Version : V1.0 Hardware Version : V1.0 Connecting I/O Port(S) : Please refer to the User's Manual Remark : the evaluation report used the EUT(202305-0134-3-2#). Report No.: TBR-C-202305-0134-4 Page: 2 of 3 TB-RF-074-1.0 MPE Calculations for WIFI 1. EUT Operation Condition: Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 2. Exposure Evaluation: Equation from page 18 of OET Bulletin 65, Edition 97-01 S=(PG)/4πR 2 Where S: power density P: power input to the antenna G: power gain of the antenna in the direction of interest relative to an isotropic radiator. R: distance to the center of radiation of the antenna 3. Simultaneous transmission MPE Considerations According to KDB447498: All transmitters and antennas in the host must be either evaluated for MPE compliance, by measurement or computational modeling, or qualify for the standalone MPE test exclusion in section 7.1. Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modeled or measured field strengths or power density, is ≤ 1.0. This means that: ∑ of MPE ratios ≤ 1.0 Report No.: TBR-C-202305-0134-4 Page: 3 of 3 TB-RF-074-1.0 4. Test Result: Mode Conducted Power(max) (dBm) Turn-up Power (dB) Max tune up power (dBm) [P] ANT Gain (dBi) [G] Distance (cm) [R] Power Density (mW/ cm 2 ) [S] Limit of Power Density (mW/ cm 2 ) (S) 802.11b 17.489 17±1 18 3.98 20 0.0314 1 17.194 17±1 18 3.98 20 0.0314 1 18.218 18±1 19 3.98 20 0.0395 1 802.11g 14.035 14±1 15 3.98 20 0.0157 1 13.699 14±1 15 3.98 20 0.0157 1 13.355 13±1 14 3.98 20 0.0125 1 802.11n(HT20) 12.904 13±1 14 3.98 20 0.0125 1 12.649 13±1 14 3.98 20 0.0125 1 13.732 14±1 15 3.98 20 0.0157 1 802.11n(HT40) 11.277 11±1 12 3.98 20 0.0079 1 11.427 11±1 12 3.98 20 0.0079 1 11.149 11±1 12 3.98 20 0.0079 1 5. Conclusion: As specified in Table 1B of 47 CFR 1.1310- Limits for Maximum Permissible Exposure (MPE), Limits for General Population/ Uncontrolled Exposure Frequency Range (MHz) Power density (mW/ cm 2 ) 300-1,500 F/1500 1,500-100,000 1.0 For 2.4WIFI :2412~2462 MHz MPE limit S: 1mW/ cm 2 The worst MPE is calculated as 0.0395mW/ cm2 < limit 1mW / cm 2 . So, RF exposure limit warning or SAR test are not required. The EUT will only be used with a separation of 20cm or greater between the antenna and nearby persons and can therefore be considered a mobile transmitter per 47 CFR2.1091 (b). The RF Exposure Information page from the manual is included here for reference. Note For a more detailed features description, please refer to the RF Test Report. 6. Conclusion: The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. -----END OF THE REPORT-----

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 1 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 RF Test Data for 2.4G WiFi (Conducted Measurements) General Description of EUT Product Name: FPT Camera Test Model: FPT Camera Play Sample ID: 202305-0134-3-2# Environmental Conditions Temperature: 25°C Relative Humidity: 55% Test Voltage: DC 5V Test Engineer: Huang jian ping Note: For a more detailed features description, please refer to the report TBR-C-202305-0134-8 The report only show the worst case data. Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 2 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Contents 1. Duty Cycle ........................................................................................................................................................................................... 3 2. Maximum Conducted Output Power ............................................................................................................................................... 10 3. -6dB Bandwidth ................................................................................................................................................................................ 11 4. Occupied Channel Bandwidth ......................................................................................................................................................... 18 5. Maximum Power Spectral Density Level ......................................................................................................................................... 25 6. Band Edge ........................................................................................................................................................................................ 32 7. Conducted RF Spurious Emission .................................................................................................................................................. 41 8. Restrict Band .................................................................................................................................................................................... 54 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 3 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 1. Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT b 2412 Ant1 100 0 0 NVNT b 2437 Ant1 100 0 0 NVNT b 2462 Ant1 100 0 0 NVNT g 2412 Ant1 90.43 0.44 0.53 NVNT g 2437 Ant1 90.05 0.46 0.53 NVNT g 2462 Ant1 90.43 0.44 0.53 NVNT n(HT20) 2412 Ant1 100 0 0 NVNT n(HT20) 2437 Ant1 100 0 0 NVNT n(HT20) 2462 Ant1 100 0 0 NVNT n(HT40) 2422 Ant1 100 0 0 NVNT n(HT40) 2437 Ant1 100 0 0 NVNT n(HT40) 2452 Ant1 100 0 0 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 4 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Test Graphs Duty Cycle NVNT b 2412MHz Ant1 Duty Cycle NVNT b 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 5 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Duty Cycle NVNT b 2462MHz Ant1 Duty Cycle NVNT g 2412MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 6 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Duty Cycle NVNT g 2437MHz Ant1 Duty Cycle NVNT g 2462MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 7 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Duty Cycle NVNT n(HT20) 2412MHz Ant1 Duty Cycle NVNT n(HT20) 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 8 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Duty Cycle NVNT n(HT20) 2462MHz Ant1 Duty Cycle NVNT n(HT40) 2422MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 9 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Duty Cycle NVNT n(HT40) 2437MHz Ant1 Duty Cycle NVNT n(HT40) 2452MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0134-8 Page: 10 of 63 FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 2. Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT b 2412 Ant1 17.489 30 Pass NVNT b 2437 Ant1 17.194 30 Pass NVNT b 2462 Ant1 18.218 30 Pass NVNT g 2412 Ant1 14.035 30 Pass NVNT g 2437 Ant1 13.699 30 Pass NVNT g 2462 Ant1 13.355 30 Pass NVNT n(HT20) 2412 Ant1 12.904 30 Pass NVNT n(HT20) 2437 Ant1 12.649 30 Pass NVNT n(HT20) 2462 Ant1 13.732 30 Pass NVNT n(HT40) 2422 Ant1 11.277 30 Pass NVNT n(HT40) 2437 Ant1 11.427 30 Pass NVNT n(HT40) 2452 Ant1 11.149 30 Pass Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Z…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202305-0134-8 Page: 1 of 46 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Test Report FCC ID: 2AKUR-PLAY01 Report No. : TBR-C-202305-0134-8 Applicant : Hangzhou Jufeng Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : FPT Camera Model No. : FPT Camera Play Series Model No. : ---- Brand Name : FPT Sample ID : 202305-0134-3-1# & 202305-0134-3-2# Receipt Date : 2023-05-22 Test Date : 2023-05-22 to 2023-07-14 Issue Date : 2023-07-21 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Witness Engineer : Wade. Lv Engineer Supervisor : Ivan Su Engineer Manager : Ray Lai This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202305-0134-8 Page: 2 of 46 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 6 1.4 Description of Support Units .............................................................................................. 7 1.5 Description of Test Mode .................................................................................................... 7 1.6 Description of Test Software Setting ................................................................................ 9 1.7 Measurement Uncertainty .................................................................................................. 9 1.8 Test Facility ......................................................................................................................... 10 2. TEST SUMMARY ..................................................................................................................... 11 3. TEST SOFTWARE ................................................................................................................... 11 4. TEST EQUIPMENT .................................................................................................................. 12 5. CONDUCTED EMISSION TEST ........................................................................................... 16 5.1 Test Standard and Limit .................................................................................................... 16 5.2 Test Setup ........................................................................................................................... 16 5.3 Test Procedure ................................................................................................................... 16 5.4 Deviation From Test Standard ......................................................................................... 17 5.5 EUT Operating Mode ........................................................................................................ 17 5.6 Test Data ............................................................................................................................. 17 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 18 6.1 Test Standard and Limit .................................................................................................... 18 6.2 Test Setup ........................................................................................................................... 20 6.3 Test Procedure ................................................................................................................... 21 6.4 Deviation From Test Standard ......................................................................................... 22 6.5 EUT Operating Mode ........................................................................................................ 22 6.6 Test Data ............................................................................................................................. 22 7. RESTRICTED BANDS REQUIREMENT ............................................................................. 23 7.1 Test Standard and Limit .................................................................................................... 23 7.2 Test Setup ........................................................................................................................... 23 7.3 Test Procedure ................................................................................................................... 24 7.4 Deviation From Test Standard ......................................................................................... 25 Report No.: TBR-C-202305-0134-8 Page: 3 of 46 TB-RF-074-1.0 7.5 EUT Operating Mode ........................................................................................................ 25 7.6 Test Data ............................................................................................................................. 25 8. BANDWIDTH TEST ................................................................................................................. 26 8.1 Test Standard and Limit .......................................…

Text truncated - open the document above for the full version.

Test Report

version01 Hangzhou Jufeng Technology Co., Ltd. Declaration concerning Antenna Specification It is hereby declared that the product Model No.: FPT Camera Play FCC ID: 2AKUR-PLAY01 fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for FPC antenna type(s) described below: Antenna No. Model No. of antenna: Type of antenna: Gain of the antenna (Max.) Frequency range: 2.4G WIFI YJC-6N045-B53 FPC Antenna 3.98dBi for 2400-2500MHz; The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: Hangzhou Jufeng Technology Co., Ltd. Address: Building 9, Yinhu Innovation Center, No.9 FuXian Road, YinHu Street, Hangzhou, China Place: Fang Lai Date: 2023-7-21 Signature:

Test Report

Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com CUSTOMERNAME CUSTOMERP/N PARTNAME FPTHead shaking machine model) P/N YJC-6N045-B53 A0 APPROVALREV. DELIVERYDATE 2022.08.17 黄腾 PREPAREDBY CHECKEDBY 伍龙飞 APPROVEDBY CustomerApproved CheckedBy PreparedBy ApprovedBy Headerquarter address: building C, Hongyu guangming valley, No.11 You Magang Road, Ma Tian Street, GuangMing District, ShenZhen Hangzhou agency: building B, Dahua Jianghong international Innovation Park,No.369 internet of Things Street, Binjiang Dstrict, Hangzhou Phone number:+86-755-27810060/23192199; fax:+86-0755-27810057 website:http://www.szsyjc.com email:[email protected] Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com content 1、cover··········································································1 2、content·······································································2 3、revised resume·····························································3 4、Antenna plane figure····················································4 5、Antenna technical parameter··········································5 6、environment performance testing····································5 7、Antenna physical figure and attached location figure····6 8、Antenna performance testing figure································6 9、 OTA active test data statistics·······················7 10、 2D、3D testing data··············································8-10 11、 ROHS material report·············································11 Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com Revised resume versio date publish A/0 2022.11.25 first version publish Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com 电器技术参数 电性能指标 ElectricalSpecifications 频率范围 电压驻波比 输入阻抗 方向 2400-2500MHz FrequencyRange VSWR 2400-2500MHz <1.92 50Ω <1.92 50Ω InputImpedance Direction Gain 全向 All 增益 dBi dBi 机械指标 MechanicalSpecifications 天线颜色 接口形式 黑色 AntennaColor Black 二代线端 Inputconnector XD(II) 工作温度 工作湿度 -20°C~+70°C WorkingTemperature WorkingHumidity -20°C~+70°C 20%~80% 20%~80% Environment performance testing: test tempearture, humidity, and air pressure without specifying as fellows: temperature: -30°C~+80°C relative humidity : 45%-85% air pressure:86kpa-106kpa Between -20°C and 70°C go on 5 loop and in normal condition after 1 hour - 2 hours checking appearance quality The size should meet the regulations and the mechanical and elecrical performance requirements Relative humidity:95±3%, experiment temperature:40°C.after ,and check its appearance after 1-2 h in normal condition The size should meet the regulations and the mechanical and elecrical performance requirements Vibrate experiment Oscillation range:10-55HZ, shifting amplitude:0.35MM, acceleration:50.0M/S,sweep loop frequency:30 times Electrical mechanical performance is normal Drop experiment Free fall from 1 meter height in the direction of mutually vertical axes for 3 times Electrical mechanical performance is normal Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com Antenna physical figure and attached location figure Antenna performance figure: Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com 深圳市英佳创电子科技有限公司 http://www.szsyjc.com OTA active test data statistics: Item Measurement Band Channel Frequency Max Min Total 1 TRP WIFI_B (11M) 1 2412 17.28 -4.18 14.02 2 3 TRP TRP WIFI_B (11M) WIFI_B (11M) WIFI_B (11M) WIFI_B (11M) WIFI_B (11M) WIFI_G (6M) WIFI_G (6M) WIFI_G (6M) WIFI_G (54M) WIFI_G (54M) WIFI_G (54M) 6 11 1 2437 2462 2412 2437 2462 2412 2437 2462 2412 2437 2462 17.43 18.68 -62.93 -62.73 -63.63 15.20 15.70 16.93 -46.62 -48.67 -50.82 -2.34 0.36 13.72 14.83 -80.34 -78.92 -78.28 11.71 12.04 13.26 -64.70 -65.19 -65.66 4 TIS(EIRP) TIS(EIRP) TIS(EIRP) TRP -84.71 -82.54 -81.93 -6.37 5 6 6 11 1 7 8 TRP 6 -4.34 9 TRP 11 1 -1.55 10 11 12 TIS(EIRP) TIS(EIRP) TIS(EIRP) -68.18 -68.85 -69.31 6 11 WIFI_N_ISM (6.5M) 13 14 15 TRP TRP TRP 1 6 2412 2437 2462 14.96 15.57 16.41 -9.48 -12.59 -8.09 10.52 11.94 11.40 WIFI_N_ISM (6.5M) WIFI_N_ISM (6.5M) 11 Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com 2D.3D testing data: (2.4G testing data) Frequency 2400MHz 2410MHz 2420MHz 2430MHz 2440MHz 2450MHz 2460MHz 2470MHz 2480MHz 2490MHz 2500MHz Efficiency(%) Gain.(dBi) 53.88 59.84 54.58 54.95 53.88 59.23 58.09 58.48 55.46 60.39 58.52 2.54 3.28 2.73 3.53 2.91 3.56 3.46 3.80 3.02 3.98 3.62 (Phi 0 2Dfigure) Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com (Phi 90 2D figure) (Theta 90 2D figure) Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com 3D testing figure (3D 2400MHz) (3D 2450MHz) (3D 2500MHz) Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com Shenzhen yingjiachuang Electronic Co.,Ltd http://www.szsyjc.com material RoHS table for declaration of conformity This is to certify that the components, auxiliary materials used, and additives used in production engineering delivered to your company comply with the environmental requirements of the RoHS Restriction on on the Use of Hazardous Substances Directive(RoHS command 2011/65/EC) The report on the composition of raw materials, packaging materials, and additives used in the production process for components and auxiliary materials is as follows: Component /Part Name Material ppm PASS? ICP report # Test Org. Test Date Composition Cd Pb Hg Cr 6+ PBB PBDE PASS FPC ND ND ND ND 5 ND ND ND ND ND ND ND ND ND ND PASS PASS PASS FPC SHAEC2202460504 CANEC2201952008 A2220404860101001C SGS SGS CTI 22/02/21 22/02/18 22/09/17 ND ND Tin phosphor bronze Gold- plating XD(II代) ND RG/RF series coaxial cable 线材 ND 10 ND ND ND ND PASS CANEC2202366903 SGS 22/02/28 第 11页共 11页

Test Setup Photos

FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Appendix V EUT Test Photographs Photo of Setup for Radiated Emission (Below 1 GHz) Photo of Setup for Radiated Emission (Above 1 GHz) FCC ID: 2AKUR-PLAY01 TB-RF-074-1.0 Photo of Setup for Radiated Emission (Above 1 GHz) Photo of Setup for Conducted Emission -----END OF THE REPORT-----

Contact Information

Applicant

Fang Lai(Manager)
[email protected]0571-23271188Fax: 0571-23271691

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz66.40 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device supports 20 and 40MHz bandwidth operation.

Other Applications from Hangzhou Jufeng Technology Co., Ltd.

FPT Camera - FCC ID 2AKUR-IQ3 - Hangzhou Jufeng Technology Co., Ltd.
2AKUR-IQ3

FPT Camera

Jul 27, 2023

Equipment Class

DTS - Digital Transmission System
NVR - FCC ID 2AKUR-NVR8008T-QWS - Hangzhou Jufeng Technology Co., Ltd.
2AKUR-NVR8008T-QWS

NVR

Sep 26, 2021

Equipment Class

DTS - Digital Transmission System