Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Allterco Robotics Add: 103 Cherni Vrah Blvd, Sofia 1407 Bulgaria Date: 2022-8-4 FCC ID: 2ALAY-SHELLYPRO2PM Dear Sir/Madam, We, Allterco Robotics Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Smart switch Model no.: Shelly PRO 2PM, Shelly PRO 1PM Sincerely, Name/Title: Dimitar Dimitrov/CEO Company: Allterco Robotics Address: 103 Cherni Vrah Blvd, Sofia 1407 Bulgaria Phone: +359 2 957 1247 Fax: +359 2 957 1248 E-Mail: [email protected]
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2022-8-4> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2ALAY-SHELLYPRO2PM Shelly PRO 2PM For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Dimitar Dimitrov/CEO Company: Allterco Robotics Address: 103 Cherni Vrah Blvd, Sofia 1407 Bulgaria Phone: +359 2 957 1247 Fax: +359 2 957 1248 E-Mail: [email protected]
Allterco Robotics 103 Cherni Vrah Blvd, Sofia 1407 Bulgaria Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2022-8-4 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2ALAY-SHELLYPRO2PM including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Dimitar Dimitrov/CEO Company: Allterco Robotics Address: 103 Cherni Vrah Blvd, Sofia 1407 Bulgaria Phone: +359 2 957 1247 Fax: +359 2 957 1248 E-Mail: [email protected]
Page1of3FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6
Page1of1FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:4.5cmxW:4.5cm) LabelLocation Smartswitch Model:ShellyPRO2PM FCCID:2ALAY-SHELLYPRO2PM
Page1of7FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of7FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of7FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Antenna Page4of7FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of7FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Page6of7FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12 Page7of7FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.13
Page1of6FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation FCCID:2ALAY-SHELLYPRO2PM EUT:Smartswitch TestModel:ShellyPRO2PM AdditionalModelNo.:ShellyPRO1PM ModelDeclaration:PCBboard,structureandinternalofthesemodelsforRFpartarethe same,onlyonerelayboardismissingforShellyPRO1PM,Sono additionalmodelsweretested. PowerSupply:Input:110-240V~,50/60Hz 16.0AMaxincandescentlamps HardwareVersion:V2.2.1 SoftwareVersion:V0.10.2-beta1 Bluetooth: FrequencyRange:2402MHz-2480MHz ChannelNumber:79channelsforBluetoothV4.2(DSS) 40channelsforBluetoothV4.2(DTS) ChannelSpacing:1MHzforBluetoothV4.2(DSS) 2MHzforBluetoothV4.2(DTS) ModulationType:GFSK,π/4-DQPSK,8-DPSKforBluetoothV4.2(DSS) GFSKforBluetoothV4.2(DTS) BluetoothVersion:V4.2 AntennaDescription:PCBAntenna,0dBi(Max.) WIFI(2.4GBand): FrequencyRange:2412MHz-2462MHz ChannelSpacing:5MHz ChannelNumber:11Channelsfor20MHzbandwidth(2412~2462MHz) 7Channelsfor40MHzbandwidth(2422~2452MHz) ModulationType:IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaDescription:PCBAntenna,0dBi(Max.) Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:MobileDevice Page2of6FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthe sumoftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoes notapplywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalent conditions.Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimum testseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmission operations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic, andElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity Page3of6FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation PCBAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/External Identification Antennatypeand antennanumber Operatefrequency band Maximum antennagain Notes AntennaPCBAntenna2400-2500MHz0dBi BT/WIFI Antenna Page4of6FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.ConductedPower [BT] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) GFSK 0024020.43 392441-0.4 792480-1.44 π/4-DQPSK 0024022.86 3924411.97 7924800.8 8-DPSK 0024023.2 3924412.46 7924801.25 [BTLE] ModeChannel Frequency (MHz) PeakConductedOutputPower (dBm) GFSK 0024020.49 192440-0.33 392480-1.44 [2.4GWLAN] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) IEEE802.11b 1241214.06 6243713.09 11246212.26 IEEE802.11g 1241212.86 6243711.74 11246211.12 IEEE802.11n HT20 1241213.04 6243711.68 11246212.79 IEEE802.11n HT40 3242211.9 6243711.23 9246211.11 Page5of6FCCID…
Text truncated - open the document above for the full version.
Page 1 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity AppendixA RF Test Data for BT (ConductedMeasurement) ProductName:Smartswitch Test Model:ShellyPRO 2PM EnvironmentalConditions Temperature: 23.8  C RelativeHumidity:52.2% ATM Pressure:100.0 kPa Test Engineer: Nick Peng Supervisedby: Li Huan Page 2 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dBBandwidth ConditionModeFrequency(MHz)Antenna-20 dB Bandwidth(MHz)Limit -20 dB Bandwidth(MHz)Verdict NVNT1-DH52402Ant10.936N/APass NVNT1-DH52441Ant10.939N/APass NVNT1-DH52480Ant10.938N/APass NVNT2-DH52402Ant11.316N/APass NVNT2-DH52441Ant11.328N/APass NVNT2-DH52480Ant11.336N/APass NVNT3-DH52402Ant11.297N/APass NVNT3-DH52441Ant11.297N/APass NVNT3-DH52480Ant11.297N/APass Page 3 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page 4 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 -20dBBandwidthNVNT2-DH52402MHzAnt1 Page 5 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT2-DH52441MHzAnt1 -20dBBandwidthNVNT2-DH52480MHzAnt1 Page 6 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT3-DH52402MHzAnt1 -20dBBandwidthNVNT3-DH52441MHzAnt1 Page 7 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT3-DH52480MHzAnt1 Page 8 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.2 MaximumPeak ConductedOutputPower ConditionModeFrequency (MHz) AntennaTotal Power (dBm) Limit (dBm) Verdict NVNT1-DH52402Ant10.4321Pass NVNT1-DH52441Ant1-0.421Pass NVNT1-DH52480Ant1-1.4421Pass NVNT2-DH52402Ant12.8621Pass NVNT2-DH52441Ant11.9721Pass NVNT2-DH52480Ant10.821Pass NVNT3-DH52402Ant13.221Pass NVNT3-DH52441Ant12.4621Pass NVNT3-DH52480Ant11.2521Pass Page 9 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page 10 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT1-DH52480MHzAnt1 PowerNVNT2-DH52402MHzAnt1 Page 11 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT2-DH52441MHzAnt1 PowerNVNT2-DH52480MHzAnt1 Page 12 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT3-DH52402MHzAnt1 PowerNVNT3-DH52441MHzAnt1 Page 13 of 54 FCC ID: 2ALAY-SHELLYPRO2PMReportNo. : LCS A051022093EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenti…
Text truncated - open the document above for the full version.
Page 1 of 36 FCCID:2ALAY-SHELLYPRO2PMReportNo.:LCSA051022093EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR AlltercoRobotics Smartswitch TestModel:ShellyPRO2PM AdditionalModelNo.:ShellyPRO1PM Preparedfor:AlltercoRobotics Address:1407Sofia,Bulgaria,103CherniVrahBlvd,Bulgaria Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:June27,2022 Numberoftestedsamples:2 SampleNo.:A051022093-1,A051022093-2 Serialnumber:Prototype DateofTest:June27,2022~July05,2022 DateofReport:July06,2022 Page 2 of 36 FCCID:2ALAY-SHELLYPRO2PMReportNo.:LCSA051022093EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA051022093EA DateofIssue.......................................:July06,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................: AlltercoRobotics Address................................................: 1407Sofia,Bulgaria,103CherniVrahBlvd,Bulgaria TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:Smartswitch TradeMark..........................................: TestModel...........................................:ShellyPRO2PM Ratings.................................................: Input:110-240V~,50/60Hz 16.0AMaxincandescentlamps Result..................................................:Positive Compiledby:Supervisedby:Approvedby: DiamondLu/Administrator CaryLuo/Techniqueprincipal GavinLiang/Manager Page 3 of 36 FCCID:2ALAY-SHELLYPRO2PMReportNo.:LCSA051022093EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA051022093EA July06,2022 Dateofissue TestModel.............................. : ShellyPRO2PM EUT......................................... : Smartswitch Applicant...............................:AlltercoRobotics Address...................................:1407Sofia,Bulgaria,103CherniVrahBlvd,Bulgaria Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:AlltercoRobotics Address...................................:1407Sofia,Bulgaria,103CherniVrahBlvd,Bulgaria Telephone...............................:/ Fax..........................................:/ Factory...................................: AlltercoRobotics Address...................................: 1407Sofia,Bulgaria,103CherniVrahBlvd,Bulgaria Telephone...............................:/ Fax..........................................:/ Page 4 of 36 FCCID:2ALAY-SHELLYPRO2PMReportNo.:LCSA051022093EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000July06,2022InitialIssue-- Page 5 of 36 FCCID:2ALAY-SHELLYPRO2PMReportNo.:LCSA051022093EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION...........................................................................................6 1.1DescriptionofDevice(EUT)...................................................................................................6 1.2SupportequipmentList...........................................................................................................7 1.3ExternalI/OCable..................................................................................................................7 1.4DescriptionofTestFacility.....................................................................................................7 1.5StatementoftheMeasurementUncertainty................…
Text truncated - open the document above for the full version.
Page1of2FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2ALAY-SHELLYPRO2PM ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotoofLineConductedEmissionsMeasurement
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.10 mW |

Smart switch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Shelly Plus Wall Dimmer US
Equipment Class
DTS - Digital Transmission System
Smart switch
Equipment Class
DTS - Digital Transmission System
Shelly RGBW2
Equipment Class
DTS - Digital Transmission System