FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Allterco Robotics/
  3. 2ALAY-SHELLYPRO3

2ALAY-SHELLYPRO3Smart switch

Allterco Robotics
Smart switch - FCC ID 2ALAY-SHELLYPRO3 - Allterco Robotics
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Nov 06, 2022
Application Purpose
Original Equipment
Date of Application
Nov 06, 2022
Equipment Note
Smart switch
Frequency Range
2402.00000000 - 2480.00000000
Company
Allterco Robotics
Country
Bulgaria

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

N N L3(C) L1(A) L2(B) S3 OUT3 S2LS1 I3O3I2O2I1O1 OUT2OUT1 LANWI-FI RESET POWER N N L3(C) L1(A) L2(B) S3 OUT3 S2LS1 I3O3I2O2I1O1 OUT2OUT1 LANWI-FI RESET POWER N N L3(C) L1(A) L2(B) S3 OUT3 S2LS1 I3O3I2O2I1O1 OUT2OUT1 LANWI-FI RESET POWER FCCWarning Thisdevicecomplieswithpart15oftheFCCrules.Operationissubjecttothefollowingtwo conditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecould voidtheuser'sauthoritytooperatetheequipment. NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoes causeharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturning theequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneor moreofthefollowingmeasures: •Reorientorrelocatethereceivingantenna. •Increasetheseparationbetweentheequipmentandreceiver. •Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. •Consultthedealeroranexperiencedradio/TVtechnicianforhelp. RadiationExposureStatement ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance20cm betweentheradiatorandyourbody.

External Photos

Page1of3FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6

ID Label/Location Info

Page1of1FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:5.0cmxW:5.0cm) LabelLocation Smartswitch Model:ShellyPRO3 FCCID:2ALAY-SHELLYPRO3

Internal Photos

Page1of4FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 BT/WIFIANT Page4of4FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

RF Exposure Info

Page1of5FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation FCCID:2ALAY-SHELLYPRO3 EUT:Smartswitch TestModel:ShellyPRO3 PowerSupply:Input:110-240V~,50/60Hz 16.0AMaxincandescentlamps HardwareVersion:-Shelly_PRO3_Buttons_v1.2.3 -Shelly_PRO3_Relays_v2.2.3 -Shelly_PRO3_Wifi_v1.2.3 SoftwareVersion:0.10.2-beta2 Bluetooth: FrequencyRange:2402MHz-2480MHz ChannelNumber:79channelsforBluetoothV4.2(DSS) 40channelsforBluetoothV4.2(DTS) ChannelSpacing:1MHzforBluetoothV4.2(DSS) 2MHzforBluetoothV4.2(DTS) ModulationType:GFSK,Ï€/4-DQPSK,8-DPSKforBluetoothV4.2(DSS) GFSKforBluetoothV4.2(DTS) BluetoothVersion:V4.2 AntennaDescription:PCBAntenna,0dBi(Max.) WIFI(2.4GBand): FrequencyRange:2412MHz-2462MHz ChannelSpacing:5MHz ChannelNumber:11Channelsfor20MHzbandwidth(2412~2462MHz) 7Channelsfor40MHzbandwidth(2422~2452MHz) ModulationType:IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaDescription:PCBAntenna,0dBi(Max.) Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:MobileDevice 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthe sumoftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating Page2of5FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoes notapplywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalent conditions.Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimum testseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmission operations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic, andElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4Ï€R² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation EUTcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/External Identification Antennatypeand antennanumber Operatefrequency band Maximum antennagain Notes AntennaPCBAntenna2400-2500MHz0dBi BT/WIFI Antenna Page3of5FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.ConductedPower [BT] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) GFSK 0024024.31 3924414.09 7924804.69 Ï€/4-DQPSK 0024023.19 3924413.2 7924803.71 8-DPSK 0024023.31 3924413.29 7924803.76 [BTLE] ModeChannel Frequency (MHz) PeakConductedOutputPower (dBm) GFSK 0024020.14 1924400.12 3924800.12 [2.4GWLAN] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) IEEE802.11b 1241215.69 6243715.68 11246215.33 IEEE802.11g 1241213.38 6243712.98 11246212.60 IEEE802.11n HT20 1241213.37 6243712.99 11246212.64 IEEE802.11n HT40 3242212.23 6243712.98 9246212.92 Page4of5FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 7.ManufacturingTolerance GFSK(Peak) ChannelChannel00Channel39Channel78 Target(dBm)4.04.04.0 Tolerance±(dB)1.01.01.0 Ï€/4-DQPSK(Peak) ChannelChannel00…

Text truncated - open the document above for the full version.

Test Report

1.Antenna Information Manufacturer Model Type Gain 2.Radiation Pattern 2400M: Shelly PRO 3 Antenna Specification Hangzhou Tuya Information Technology Co., Ltdd Shelly PRO 3 PCB 0dBi , � ' ' • • ·• . 2450MHz • • ••• 2500MHz • • • 3.Gain table of Antenna frequency gain efficiency Frequency I MHz Efficiency I % Gain/ dBi 2400 16.37 -0.77 2410 16.83 -0.95 2420 17.54 -1.2 2430 18.03 -1.15 2440 18.79 -1.21 2450 18.97 0.0 2460 18.45 -1.18 2470 17.82 -1.12 2480 17.38 -1.05 2490 16.67 -0.79 4.PCB photo

Test Report

Page 1 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity AppendixA RF Test Data for BT (ConductedMeasurement) ProductName:Smartswitch Test Model:ShellyPRO 3 EnvironmentalConditions Temperature: 23.8 ï‚° C RelativeHumidity:52.1% ATM Pressure:100.0 kPa Test Engineer: MonkeyLi Supervisedby: Li Huan Page 2 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.1 20dB EmissionBandwidth Test Result TestModeAntennaChannel 20db EBW[MHz] FL[MHz]FH[MHz]Verdict DH5Ant1 24020.9842401.5142402.498--- 24410.9992440.4692441.468--- 24800.9812479.5022480.483--- 2DH5Ant1 24021.3142401.3372402.651--- 24411.2872440.3582441.645--- 24801.2992479.3522480.651--- 3DH5Ant1 24021.3442401.3222402.666--- 24411.3142440.3372441.651--- 24801.2722479.3462480.618--- Page 3 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page 4 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2402 2DH5_Ant1_2441 Page 5 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2480 3DH5_Ant1_2402 Page 6 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 3DH5_Ant1_2441 3DH5_Ant1_2480 Page 7 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximumconductedoutputpower Test Result TestModeAntennaChannelResult[dBm]Limit[dBm]Verdict DH5Ant1 24024.31≤20.97PASS 24414.09≤20.97PASS 24804.69≤20.97PASS 2DH5Ant1 24023.19≤20.97PASS 24413.2≤20.97PASS 24803.71≤20.97PASS 3DH5Ant1 24023.31≤20.97PASS 24413.29≤20.97PASS 24803.76≤20.97PASS Page 9 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page 10 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2402 2DH5_Ant1_2441 Page 11 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2480 3DH5_Ant1_2402 Page 12 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 3DH5_Ant1_2441 3DH5_Ant1_2480 Page 13 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Page 14 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.3 Carrierfrequenc…

Text truncated - open the document above for the full version.

Test Report

Page 28 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 3DH5_Ant1_High_2480 3DH5_Ant1_Low_Hop_2402 Page 29 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 3DH5_Ant1_High_Hop_2480 Page 30 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.7 ConductedSpuriousEmission Test Result TestModeAntennaChannel FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1 2402 Reference-0.66-0.66---PASS 30~1000-0.66-60.43≤-20.66PASS 1000~26500-0.66-45.9≤-20.66PASS 2441 Reference-0.63-0.63---PASS 30~1000-0.63-59.97≤-20.63PASS 1000~26500-0.63-46.31≤-20.63PASS 2480 Reference-0.82-0.82---PASS 30~1000-0.82-60.84≤-20.82PASS 1000~26500-0.82-44.65≤-20.82PASS 2DH5Ant1 2402 Reference-5.33-5.33---PASS 30~1000-5.33-61≤-25.33PASS 1000~26500-5.33-45.59≤-25.33PASS 2441 Reference-4.51-4.51---PASS 30~1000-4.51-60.57≤-24.51PASS 1000~26500-4.51-45.4≤-24.51PASS 2480 Reference-1.78-1.78---PASS 30~1000-1.78-60.42≤-21.78PASS 1000~26500-1.78-45.22≤-21.78PASS 3DH5Ant1 2402 Reference-4.71-4.71---PASS 30~1000-4.71-53.06≤-24.71PASS 1000~26500-4.71-45.92≤-24.71PASS 2441 Reference-4.54-4.54---PASS 30~1000-4.54-60.3≤-24.54PASS 1000~26500-4.54-45.19≤-24.54PASS 2480 Reference-4.95-4.95---PASS 30~1000-4.95-60.77≤-24.95PASS 1000~26500-4.95-45.92≤-24.95PASS Page 31 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 Page 32 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 Page 33 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference Page 34 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity DH5_Ant1_2480_30~1000 DH5_Ant1_2480_1000~26500 Page 35 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2402_0~Reference 2DH5_Ant1_2402_30~1000 Page 36 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference Page 37 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 Page 38 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 Page 39 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2480_1000~26500 3DH5_Ant1_2402_0~Reference Page 40 of 52FCC ID: 2ALAY-SHELLYPRO3ReportNo. : LCS A090122147EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authentici…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 36 FCCID:2ALAY-SHELLYPRO3ReportNo.:LCSA090122147EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR AlltercoRobotics Smartswitch TestModel:ShellyPRO3 Preparedfor:AlltercoRobotics Address:103CherniVrahBlvd,Sofia,1407Bulgaria Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:September16,2022 Numberoftestedsamples:2 SampleNo.:A090122147-1,A090122147-2 Serialnumber:Prototype DateofTest:September16,2022~September29,2022 DateofReport:October08,2022 Page 2 of 36 FCCID:2ALAY-SHELLYPRO3ReportNo.:LCSA090122147EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA090122147EA DateofIssue.......................................:October08,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–¡ Otherstandardtestingmethodâ–¡ Applicant’sName.............................: AlltercoRobotics Address................................................: 103CherniVrahBlvd,Sofia,1407Bulgaria TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:Smartswitch TradeMark..........................................: TestModel...........................................:ShellyPRO3 Ratings.................................................: Input:110-240V~,50/60Hz 16.0AMaxincandescentlamps Result..................................................:Positive Compiledby:Supervisedby:Approvedby: DiamondLu/Administrator CaryLuo/Techniqueprincipal GavinLiang/Manager Page 3 of 36 FCCID:2ALAY-SHELLYPRO3ReportNo.:LCSA090122147EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA090122147EA October08,2022 Dateofissue TestModel.............................. : ShellyPRO3 EUT......................................... : Smartswitch Applicant...............................:AlltercoRobotics Address...................................:103CherniVrahBlvd,Sofia,1407Bulgaria Telephone...............................: / Fax..........................................:/ Manufacturer.........................: AlltercoRobotics Address...................................:103CherniVrahBlvd,Sofia,1407Bulgaria Telephone...............................: / Fax..........................................:/ Factory...................................: AlltercoRobotics Address...................................: 103CherniVrahBlvd,Sofia,1407Bulgaria Telephone...............................:/ Fax..........................................:/ Page 4 of 36 FCCID:2ALAY-SHELLYPRO3ReportNo.:LCSA090122147EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000October08,2022InitialIssue--- Page 5 of 36 FCCID:2ALAY-SHELLYPRO3ReportNo.:LCSA090122147EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION...........................................................................................6 1.1DescriptionofDevice(EUT)...................................................................................................6 1.2SupportequipmentList...........................................................................................................7 1.3ExternalI/OCable..................................................................................................................7 1.4DescriptionofTestFacility.....................................................................................................7 1.5StatementoftheMeasurementUncertainty...........................................................................7 1…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2ALAY-SHELLYPRO3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotoofLineConductedEmissionsMeasurement

Contact Information

Applicant

Dimitar Dimitrov(CEO)
[email protected]+359 2 957 1247Fax: +359 2 957 1248

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.90 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Allterco Robotics

Shelly Plus Wall Dimmer US - FCC ID 2ALAYSNDM-0013US - Allterco Robotics
2ALAYSNDM-0013US

Shelly Plus Wall Dimmer US

Sep 27, 2022

Equipment Class

DTS - Digital Transmission System
Smart switch - FCC ID 2ALAY-SHELLYPRO2PM - Allterco Robotics
2ALAY-SHELLYPRO2PM

Smart switch

Aug 03, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart switch - FCC ID 2ALAY-SHELLYPRO2 - Allterco Robotics
2ALAY-SHELLYPRO2

Smart switch

Aug 03, 2022

Equipment Class

DTS - Digital Transmission System
Shelly RGBW2 - FCC ID 2ALAYSHRGBW-V2 - Allterco Robotics
2ALAYSHRGBW-V2

Shelly RGBW2

Apr 13, 2022

Equipment Class

DTS - Digital Transmission System