2ALC5-KNX-ETAG1UWB Tracking Tag with ePaper Display

KINEXON Inc.
UWB Tracking Tag with ePaper Display - FCC ID 2ALC5-KNX-ETAG1 - KINEXON Inc.
Click to zoom

Application Details

Equipment Class
WBT - Wideband Transmitter
Date of Grant
Mar 23, 2022
Application Purpose
Original Equipment
Date of Application
Mar 23, 2022
Equipment Note
UWB Tracking Tag with ePaper Display
Frequency Range
6248.26000000 - 6746.92000000
Company
KINEXON Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—
β†—

Cover Letter(s)

β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual Paperless Logistics/Manufacturing Exported on 03/18/2022 Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual – 2 Table of Contents 1 Introduction ............................................................................................................ 4 2 Safety Information .................................................................................................. 6 3 Disclaimer ................................................................................................................ 7 4 Intended Use ........................................................................................................... 8 5 Key Facts.................................................................................................................. 9 6 External Interfaces ................................................................................................ 12 6.1 Wireless Connection ................................................................................................................... 12 6.2 Interaction Buttons ..................................................................................................................... 12 6.3 Visual LEDs................................................................................................................................... 13 6.4 Tag Battery .................................................................................................................................. 14 7 Hardware Variants ................................................................................................ 15 8 Accessories ............................................................................................................ 16 8.1 Holder .......................................................................................................................................... 16 9 Regulatory and Legal Information ....................................................................... 17 9.1 FCC Compliance .......................................................................................................................... 17 9.2 ISED Caution................................................................................................................................ 17 Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual – 3 β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ Introduction(see page 4) Safety Information(see page 6) Disclaimer(see page 7) Intended Use(see page 8) Key Facts(see page 9) RF Specifications(see page 9) Physical Specifications(see page 9) Environmental Specifications(see page 10) Mechanical Drawing(see page 11) Label Specifications(see page 11) External Interfaces(see page 12) Wireless Connection(see page 12) Interaction Buttons(see page 12) Visual LEDs(see page 13) Tag Battery(see page 14) Hardware Variants(see page 15) Accessories(see page 16) Holder(see page 16) Regulatory and Legal Information(see page 17) FCC Compliance(see page 17) ISED Caution(see page 17) Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual Introduction – 4 β€’ β€’ β€’ β€’ 1 Introduction The KINEXON ePaper Tag is the Ultra-Wideband basic component for a paperless material and goods handling in industry. The ePaper solution combines high precision UWB localization technology with smart process visualization. The KINEXON ePaper Tag can be placed on workpieces and load carriers without leaving any residue to track their entire value-added process. In addition, an integrated display automatically informs about production steps that have already been completed and those that are still pending. As a result, all information is digitized, repeated and printing processes are eliminated. KINEXON ePaper solution is flexible and provides complete control and maximum flexibility for dynamic production. The combination of high precision real time localization and smart visualization is the key to a paperless production. There are various potential use cases such as: ePaper-based workflow-instructions for shop floor employees. Real-time interaction through configurable button (e.g. signal for replenishment). Dynamic labeling with current status of the product or material. Digitization of all production & process relevant information. Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual Introduction – 5 Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual Safety Information – 6 β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ 2 Safety Information Read and follow all instructions before using the KINEXON ePaper Tag. Never open the case of the KINEXON ePaper Tag. There are no user serviceable parts or replaceable parts inside the case. Do not use the KINEXON ePaper Tag if it has been damaged. Use the Tag according to the following specifications. KINEXON will not take any responsibility or liability in case of accidents caused by misuse of the battery: Stop using the device immediately and stay away from battery if: The battery was exposed to high temperatures (60 Β°C or above). The battery shows signs of leakage. There is a noticeable odor coming from the battery. Avoid directly hitting or dropping the battery. Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual Disclaimer – 7 3 Disclaimer The information in this document is subject to change without notice. KINEXON GmbH assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact KINEXON GmbH. Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Non-Rechargeable) - User Manual Intended Use – 8 4 Intended Use This m…

Text truncated - open the document above for the full version.

Users Manual

THE KINEXON ePaper Tag (Rechargeable) - User Manual Paperless Logistics/Manufacturing Exported on 03/18/2022 Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Rechargeable) - User Manual – 2 Table of Contents 1 Introduction ............................................................................................................ 4 2 Safety Information .................................................................................................. 6 3 Disclaimer ................................................................................................................ 7 4 Intended Use ........................................................................................................... 8 5 Key Facts.................................................................................................................. 9 6 External Interfaces ................................................................................................ 13 6.1 Wireless Connection ................................................................................................................... 13 6.2 Interaction Buttons ..................................................................................................................... 13 6.3 Visual LEDs................................................................................................................................... 14 6.4 Tag Battery .................................................................................................................................. 15 7 Hardware Variants ................................................................................................ 16 8 Accessories ............................................................................................................ 17 8.1 Charging Cradle........................................................................................................................... 17 8.2 Holder .......................................................................................................................................... 17 9 Regulatory and Legal Information ....................................................................... 18 9.1 FCC Compliance .......................................................................................................................... 18 9.2 ISED Caution................................................................................................................................ 18 Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Rechargeable) - User Manual – 3 β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ Introduction(see page 4) Safety Information(see page 6) Disclaimer(see page 7) Intended Use(see page 8) Key Facts(see page 9) RF Specifications(see page 9) Physical Specifications(see page 10) Environmental Specifications(see page 10) Mechanical Drawing(see page 12) Label Specifications(see page 12) External Interfaces(see page 13) Wireless Connection(see page 13) Interaction Buttons(see page 13) Visual LEDs(see page 14) Tag Battery(see page 15) Hardware Variants(see page 16) Accessories(see page 17) Charging Cradle(see page 17) Holder(see page 17) Regulatory and Legal Information(see page 18) FCC Compliance(see page 18) ISED Caution(see page 18) Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Rechargeable) - User Manual Introduction – 4 β€’ β€’ β€’ β€’ 1 Introduction The KINEXON ePaper Tag is the Ultra-Wideband basic component for a paperless material and goods handling in industry. The ePaper solution combines high precision UWB localization technology with smart process visualization. The KINEXON ePaper Tag can be placed on workpieces and load carriers without leaving any residue to track their entire value-added process. In addition, an integrated display automatically informs about production steps that have already been completed and those that are still pending. As a result, all information is digitized, repeated and printing processes are eliminated. KINEXON ePaper solution is flexible and provides complete control and maximum flexibility for dynamic production. The combination of high precision real time localization and smart visualization is the key to a paperless production. There are various potential use cases such as: ePaper-based workflow-instructions for shop floor employees. Real-time interaction through configurable button (e.g. signal for replenishment). Dynamic labeling with current status of the product or material. Digitization of all production & process relevant information. Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Rechargeable) - User Manual Introduction – 5 Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Rechargeable) - User Manual Safety Information – 6 β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ 2 Safety Information Read and follow all instructions before using the KINEXON ePaper Tag. Never open the case of the KINEXON ePaper Tag. There are no user serviceable parts or replaceable parts inside the case. Do not use the KINEXON ePaper Tag if it has been damaged. Use the Tag according to the following specifications. KINEXON will not take any responsibility or liability in case of accidents caused by misuse of the battery: Stop using the device immediately and stay away from battery if: The battery was exposed to high temperatures (60 Β°C or above). The battery shows signs of leakage. There is a noticeable odor coming from the battery. Avoid directly hitting or dropping the battery. Paperless Logistics/Manufacturing – THE KINEXON ePaper Tag (Rechargeable) - User Manual Disclaimer – 7 3 Disclaimer The information in this document is subject to change without notice. KINEXON GmbH assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, co…

Text truncated - open the document above for the full version.

Cover Letter(s)

CSA Internal | 3rd Party Request for Confidentiality Date: August 2, 2021 Subject: Confidentiality Request for FCC ID: 2ALC5-KNX-ETAG1 Pursuant to FCC 47 CRF 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* 3 UVerΒΆV ManXal Kinexon Inc. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of (specify number of days not to exceed 180) 2 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify Phoenix Testlab GmbH in the event information regarding the product or the product is made available to the public. Phoenix Testlab GmbH will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: __________________________ Mehdi Bentanfous (Signature/Title 3 ) CEO 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

Cover Letter(s)

CSA Internal | 3rd Party Authority to Act as Agent Date: July 6, 2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We the undersigned, hereby authorize CSA Group Bayern GmbH, Ms. Irina Bauer, Ohmstrasse 1-4, 94342 Strasskirchen, Germany to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by CSA Group Bayern GmbH on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from Kinexon Inc. By: __________________________ Mehdi Bentanfous (Signature 1 ) Tit le: CEO On behalf of: KINEXON Inc. Telephone: 1-646-469-9363 Email: [email protected] 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be pla ced o n a p p ro p ria t e let t erh ea d .

Cover Letter(s)

β€’ β€’ β€’

External Photos

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 1 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential Attachment A Type / Model Name : KNX-T5.1-5 / ePaper Tag Product Description : UWB Tracking Tag with ePaper Display Applicant : Kinexon Inc. Address : 200 S Wacker Drive, Suite 3100 CHICAGO, IL 60606, USA Manufacturer : Kinexon GmbH Address : Schellingstraße 35 80799 MÜNCHEN, GERMANY according to Test Report No. : 80081673-00 to 80081673-07 11. September 2021 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 2 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential Contents 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 3 1.1 The EUT is applied in the following variants 3 1.2 External views 3 1.3 Internal views 5 1.4 HF part and antenna 8 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 3 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 1.1 The EUT is applied in the following variants There are eight variants of the EUT. Model Description Comment KNX-T5.1-1.1-2 Model with primary battery, b/w/r display not tested KNX-T5.1-1.4-2 Model with primary battery, b/w display not tested KNX-T5.1-4.1-1 Model with primary battery, b/w/r display, BLE module not tested KNX-T5.1-4.4-1 Model with primary battery, b/w display, BLE module not tested KNX-T5.1-2.2-2 Model with Qi charging, b/w/r display not tested KNX-T5.1-2.5-2 Model with Qi charging, b/w display not tested KNX-T5.1-5.2-1 Model with Qi charging, b/w/r display, BLE module tested KNX-T5.1-5.5-1 Model with Qi charging, b/w display, BLE module not tested All tests presented in the report were performed with the variant KNX-T5.1-5.2-1. All other variants were not tested and we do not take any responsibility for or make statements about the conformity. 1.2 External views The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 4 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 5 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential 1.3 Internal views

ID Label/Location Info

2ALC5-KNX-ETAG1 KNX-T5.1-2.2-2 Contains FCC ID: X8WBT840F This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation. KNX-T5.1-2.5-2 Contains FCC ID: X8WBT840F 2ALC5-KNX-ETAG1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation. KNX-T5.1-5.2-1 Contains FCC ID: X8WBT840F 2ALC5-KNX-ETAG1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation. KNX-T5.1-5.5-1 Contains FCC ID: X8WBT840F 2ALC5-KNX-ETAG1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation.

Internal Photos

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 1 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential Attachment A Type / Model Name : KNX-T5.1-5 / ePaper Tag Product Description : UWB Tracking Tag with ePaper Display Applicant : Kinexon Inc. Address : 200 S Wacker Drive, Suite 3100 CHICAGO, IL 60606, USA Manufacturer : Kinexon GmbH Address : Schellingstraße 35 80799 MÜNCHEN, GERMANY according to Test Report No. : 80081673-00 to 80081673-07 11. September 2021 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 5 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential 1.3 Internal views The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 6 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 7 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permiss i on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-00 to 80081673-07, page 8 of 8 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential 1.4 HF part and antenna UWB BLE - End of attachment_A -

Test Report

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80081673-04 Rev2, page 1 of 30 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential EMI βˆ’ T E S T R E P O R T - FCC Part 15.250, RSS-210 - Type / Model Name : KNX-T5.1-5 / ePaper Tag Product Description : UWB Tracking Tag with ePaper Display Applicant : Kinexon Inc. Address : 200 S Wacker Drive, Suite 3100 CHICAGO, IL 60606, USA Manufacturer : Kinexon GmbH Address : Schellingstraße 35 80799 MÜNCHEN, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE Test Report No. : 80081673-04 Rev2 09. September 2021 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-ETAG1 IC: 25557-KNXETAG1 CSA Group Bayern GmbH File No. 80081673-04 Rev2, page 2 of 30 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential Contents 1 T E S T S T A N D A R D S 3 2 E Q U I P M E N T U N D E R T E S T 4 2.1 General remarks 4 2.2 Information provided by the Client 4 2.3 Sampling 4 2.4 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 4 2.5 Equipment type 4 2.6 Short description of the equipment under test (EUT) 4 2.7 Variants of the EUT 5 2.8 Operation frequency and channel plan 5 2.9 Transmit operating modes 5 2.10 Antenna 5 2.11 Power supply system utilised 5 2.12 Peripheral devices and interface cables 5 2.13 Determination of worst case conditions for final measurement 6 3 T E S T R E S U L T S U M M A R Y 7 3.1 Final assessment 7 4 T E S T E N V I R O N M E N T 8 4.1 Address of the test laboratory 8 4.2 Environmental conditions 8 4.3 Statement of the measurement uncertainty 8 4.4 Conformity Decision Rule 8 5 T E S T C O N D I T I O N S A N D R E S U L T S 11 5.1 WBT Bandwidth 11 5.2 Radiated Emissions 9 kHz to 40 GHz 15 5.3 Radiated Emissions at 1164-1240 MHz and 1559-1610 MHz 21 5.4 Peak Power radiated 26 5.5 Antenna application 29 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 30 ATTACHMENT A separate supplement The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-ETAG1 IC: 25557-KNXETAG1 CSA Group Bayern GmbH File No. 80081673-04 Rev2, page 3 of 30 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September 2020) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September 2020) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements Part 15, Subpart C, Section 15.250 Operation of wideband systems within the band 5925-7250 MHz ANSI C63.10: 2013 Testing Unlicensed Wireless Devices ETSI TR 100 028 V1.3.1: 2001-03 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristicsβ€”Part 1 and Part 2 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-ETAG1 IC: 25557-KNXETAG1 CSA Group Bayern GmbH File No. 80081673-04 Rev2, page 4 of 30 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential 2 E Q U I P M E N T U N D E R T E S T 2.1 General remarks This test report replaces the test report 80081673-01 Rev1. The changes are as follows: - using WBT instead of UWB - additional remarks on page 30 Rev1 changes: - redefining type / model name on page 1 - expansion and redefining of variants of the EUT on page 5 - redefining power supply list on page 5 Rev0: Initial report 2.2 Information provided by the Client Please note, we do not take any responsibility for information provided by the client or his representative which may have an influence on the validity of the test results. 2.3 Sampling The customer is responsible for the choice of sample. Sample configuration, start-up and operation is carried out by the customer or according his/her instructions. 2.4 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 2.5 Equipment type Portable WBT Device 2.6 Short description of the equipment under test (EUT) The ePaper solution combines high-precision WBT localization technology with smart process visualization. The KINEXON ePaper Tag can be placed on workpieces and load carriers to track their entire value-added process. In addition, an integrated display automatically informs about production steps. Number of tested samples: 1 Serial number: 233247 (cont. transmission on channel 5) WBT driver version: 5.1 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-ETAG1 IC: 25557-KNXETAG1 CSA Group Bayern GmbH File No. 80081673…

Text truncated - open the document above for the full version.

Test Setup Photos

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-ETAG1 IC: 25557-KNXETAG1 CSA Group Bayern GmbH File No. 80081673-04 Rev0, page 10 of 29 Ohmstrasse 1-4 ο‚ž 94342 STRASSKIRCHEN ο‚ž GERMANY Tel.: +49(0)9424-94810 ο‚ž Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential 5 T E S T C O N D I T I O N S A N D R E S U L T S 5.1 UWB Bandwidth For test instruments and accessories used see section 6 Part CPR 3. 5.1.1 Description of the test location Test location: Anechoic chamber 1 5.1.2 Photo documentation of the test set-up The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-ETAG1 IC: 25557-KNXETAG1 CSA Group Bayern GmbH File No. 80081673-04 Rev0, page 11 of 29 Ohmst…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mehdi Bentanfous(CEO)
[email protected](347) 630-0208Fax: (347) 630-0208

Test Firm

CSA Group Bayern GmbHFrank Scharnowski
[email protected]+49 9931 9836 140

Technical Specifications

#Rule PartsFrequency RangePower Output
115.2506.25 GHz - 6.75 GHz-
Confidentiality
Long Term
Grant Notes
May contain modular approved transmitter with FCC ID: X8WBT840F and WPT receiver. This device is approved for mobile RF exposure operating conditions.

Other Applications from KINEXON Inc.

TAG for UWB localization system - FCC ID 2ALC5-KNX-HTAG2 - KINEXON Inc.
2ALC5-KNX-HTAG2

TAG for UWB localization system

Aug 18, 2024

Equipment Class

UWB - Ultra Wideband Transmitter
TAG for UWB localization system - FCC ID 2ALC5-KNX-TM1 - KINEXON Inc.
2ALC5-KNX-TM1

TAG for UWB localization system

Jul 30, 2024

Equipment Class

UWB - Ultra Wideband Transmitter
Anchor for UWB localization system - FCC ID 2ALC5-KNX-AM1 - KINEXON Inc.
2ALC5-KNX-AM1

Anchor for UWB localization system

Jul 09, 2024

Equipment Class

UWB - Ultra Wideband Transmitter
External Tool-Tag - FCC ID 2ALC5-KNX-HCTAG1 - KINEXON Inc.
2ALC5-KNX-HCTAG1

External Tool-Tag

Sep 25, 2022

Equipment Class

WBT - Wideband Transmitter
Tracking System - FCC ID 2ALC5-KNX-STAG1 - KINEXON Inc.
2ALC5-KNX-STAG1

Tracking System

Aug 11, 2020

Equipment Class

WBT - Wideband Transmitter