Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
External Tool Tag - User Manual (US/CA) Product Management Exported on 09/22/2022 Product Management – External Tool Tag - User Manual (US/CA) – 2 Table of Contents 1KINEXON External Tool Tag...................................................................................4 2SPECIFICATIONS....................................................................................................6 2.1Mechanical Drawing.....................................................................................................................6 2.2Label.............................................................................................................................................7 2.2.1Label back plate.........................................................................................................................................................7 2.2.2Label top cover...........................................................................................................................................................7 2.3External interfaces.......................................................................................................................7 2.3.1Wireless connection...................................................................................................................................................7 2.3.2Tag LED.......................................................................................................................................................................8 2.3.3Electrical Parameters.................................................................................................................................................8 2.4Battery..........................................................................................................................................8 3Regulatory and Legal Information........................................................................9 3.1Disclaimer.....................................................................................................................................9 3.2Intended Use................................................................................................................................9 3.3FCC Compliance...........................................................................................................................9 3.4FCC Caution..................................................................................................................................9 3.5ISED Caution...............................................................................................................................10 3.6Safety Information.....................................................................................................................10 Product Management – External Tool Tag - User Manual (US/CA) – 3 THE KINEXON External Tool Tag Product Management – External Tool Tag - User Manual (US/CA) KINEXON External Tool Tag – 4 • • • • • • • • 1 KINEXON External Tool Tag Real-time localization with high update rates and long battery lifetime. The KINEXON External Tool Tag is the perfect sensor for indoor localization in industrial and logistics environments. By mounting or embedding the tag on the object, it enables a precise and robust localization of all assets on the shop floor. Thus, the KINEXON External Tool Tag provides the basis for track & trace of your objects, workflow monitoring and process automation. Due to its big battery even dynamic movements that require a high update rate can be tracked over multiple years. Use Cases Track & Trace and optimized material handling of moving assets in industrial environments such as: Material & Goods Load Carrier (Barred box, pallet etc.) Manufactured products Tools Real-time location data is the enabler for improved process reliability and efficiency through process automation and optimization such as: Storage Automation Elimination of manual scanning Full transparency over material flow (cycle times, idle times etc.) Process Monitoring & Process Mining KEYFACTS RF Specifications Positioning PrincipleReal-time location system (RTLS, radio-based, ultra-wideband) Frequency RangeUWB (IEEE 802.15.4a): UWB Channel 5 (6.25 - 6.75 GHz) Average EIRP < -41 dBm / 1 MHz Peak EIRP < 0 dBm / 50 MHz Positioning Update Rate0.01 - 20 Hz Positioning Data3D (x, y, z) Positioning Accuracy< 10 cm (depending on environment) Physical Specifications IndicatorsStatus LED Inertial Measurement (Accelerometer) 3-axis, +/- 0.05g to +/-16g, up to 200 Hz, typically 5Hz Product Management – External Tool Tag - User Manual (US/CA) KINEXON External Tool Tag – 5 Physical Specifications BatteryInternal non-replaceable Li primary battery Battery LifetimeUp to 3 years (highly dependent on configuration) Material Weight200 g Dimensions85 x 56 x 44 mm Environmental Specifications Operating Temperature-20°C to 60°C incl. battery Storage Temperature-20 °C to + 30 °C incl. battery CleaningPossible to disinfect with Ethanol-containing disinfecting solutions from 40-96% of Ethanol (only surface cleaning – no immersing!) Do not use methanol, isopropanol or isopropyl alcohols for cleaning! Water RepellentTag can be wiped wet with water (no immersing!) Protection classIP65 Regulatory compliance (pending)US: FCC Part 15 Subpart C (15.250); European Union: ETSI EN 302 065-1, ETSI EN 303 883, ETSI EN 301489-1, ETSI EN 301489-17, ETSI EN 301489-33, EN 62311, 1999/519/EC, EN 62368-1 FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557-KNXHCTAG1 ANATEL ID: XXXXX-XX-XXXXX Product Management – External Tool Tag - User Manual (US/CA) SPECIFICATIONS – 6 2 SPECIFICATIONS 2.1 Mechanical Drawing Product Management – External Tool Tag - User Manual (US/CA) SPECIFICATIONS – 7 2.2 Label 2.2.1 Label back plate QR code EUI Device part-no. Certification logos/signs Company logo Size: (23x 55) mm 2.2.2 Label top cover Company logo EUI QR code Size: (20 x 25) mm 2.3 External interfaces 2.…
Text truncated - open the document above for the full version.
Request for Confidentiality Date: February 7, 2022 Subject: Confidentiality Request for FCC ID: 2ALC5-KNX-HCTAG1 Pursuant to FCC 47 CRF 0.457(d) and 0.459 the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* 3 UVer¶V ManXal KINEXON Inc. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of (specify number of days not to exceed 180) 2 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify Phoenix Testlab GmbH in the event information regarding the product or the product is made available to the public. Phoenix Testlab GmbH will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: ______________________________________________________ (Signature/Title 3 ) Mehdi Bentanfous CRO (Chief Revenue Officer Industries) 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
Authority to Act as Agent Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We the undersigned, hereby authorize CSA Group Bayern GmbH, Ms. Irina Bauer, Ohmstrasse 1-4, 94342 Strasskirchen, Germany to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by CSA Group Bayern GmbH on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from Kinexon Inc. By: __________________________ Mehdi Bentanfous (Signature 1 ) Tit le: CEO On behalf of: KINEXON Inc. Telephone: 1-646-469-9363 Email: 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead. We, the undersigned, hereby authorize CSA Group Bayern, Ms. Christa Jaeger, Ohmstrasse 1-4, 94342 Strasskirchen, Germany to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by CSA Group Bayern GmbH on our behalf shall have the same affect as acts of our own. Date: January 13, 2022 [email protected]
The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 1 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential Attachment A Type / Model Name : KNX-T6.1-1.2 / High-Capacity X-Tag Product Description : Tracking Tag Applicant : Kinexon Sports & Media Inc Address : 22 west 38th NEW YORK, NY 10018, USA Manufacturer : Kinexon GmbH Address : Schellingstraße 35 80799 MÜNCHEN, GERMANY according to Test Report No. : 80115860-00 to 80115860-04 20. September 2022 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 2 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential Contents 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 3 1.1 The EUT is applied in the following variants 3 1.2 External views 3 1.3 Internal views and antenna structure 6 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 3 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 1.1 The EUT is applied in the following variants There are no variants. 1.2 External views The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 4 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 5 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential test sample prepared for conducted measurements:
EUI: XXXXXX Model: KNX-T6.1-1.2-1 FCC ID: 2ALC5-KNX-HCTAG1 CMIIT ID: XXXXYZNNNN
Area forlabelon top side Area forlabelon bottomside Top Bottom
The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 1 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential Attachment A Type / Model Name : KNX-T6.1-1.2 / High-Capacity X-Tag Product Description : Tracking Tag Applicant : Kinexon Sports & Media Inc Address : 22 west 38th NEW YORK, NY 10018, USA Manufacturer : Kinexon GmbH Address : Schellingstraße 35 80799 MÜNCHEN, GERMANY according to Test Report No. : 80115860-00 to 80115860-04 20. September 2022 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 6 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential 1.3 Internal views and antenna structure The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 7 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-00 to 80115860-04, page 8 of 8 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 5.0, 2020-02-11 CSA Confidential test sample prepared for conducted measurements: - End of attachment_A -
The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-03 Rev2, page 1 of 27 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential EMI − T E S T R E P O R T - FCC Part 15.250, RSS-210 - Type / Model Name : KNX-T6.1-1.2 / High-Capacity X-Tag Product Description : Tracking Tag Applicant : KINEXON Inc. Address : 200 S Wacker Dr Suite 3100 CHICAGO, IL 60606, U.S.A. Manufacturer : Kinexon GmbH Address : Schellingstraße 35 80799 MÜNCHEN, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE Test Report No. : 80115860-03 Rev2 22. September 2022 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557KNX-HCTAG1 CSA Group Bayern GmbH File No. 80115860-03 Rev2, page 2 of 27 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential Contents 1 T E S T S T A N D A R D S 3 2 E Q U I P M E N T U N D E R T E S T 4 2.1 Information provided by the Client 4 2.2 Sampling 4 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 4 2.4 Equipment type 4 2.5 Short description of the equipment under test (EUT) 4 2.6 Variants of the EUT 4 2.7 Operation frequency and channel plan 4 2.8 Transmit operating modes 4 2.9 Antenna 5 2.10 Power supply system utilised 5 2.11 Peripheral devices and interface cables 5 2.12 Determination of worst case conditions for final measurement 5 3 T E S T R E S U L T S U M M A R Y 6 3.1 Revision history of test report 6 3.2 Final assessment 7 4 T E S T E N V I R O N M E N T 8 4.1 Address of the test laboratory 8 4.2 Environmental conditions 8 4.3 Statement of the measurement uncertainty 8 4.4 Conformity Decision Rule 9 4.5 Measurement protocol for FCC and ISED 9 5 T E S T C O N D I T I O N S A N D R E S U L T S 12 5.1 UWB Bandwidth 12 5.2 Radiated Emissions 9 kHz to 40 GHz 15 5.3 Radiated Emissions at 1164-1240 MHz and 1559-1610 MHz 21 5.4 Peak Power radiated 25 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 27 ATTACHMENT A separate supplement The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557KNX-HCTAG1 CSA Group Bayern GmbH File No. 80115860-03 Rev2, page 3 of 27 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September 2021) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements Part 15, Subpart C, Section 15.250 Operation of wideband systems within the band 5925-7250 MHz Industry Canada – Radio equipment standards RSS-Gen, Issue 5 + A1 + A2, March 2019 General Requirements for Compliance of Radio Apparatus RSS-210, Issue 10, December 2019 Licence-Exempt Radio Apparatus: Category I Equipment ANSI C63.10: 2013 Testing Unlicensed Wireless Devices ETSI TR 100 028 V1.3.1: 2001-03 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristics—Part 1 and Part 2 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557KNX-HCTAG1 CSA Group Bayern GmbH File No. 80115860-03 Rev2, page 4 of 27 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential 2 E Q U I P M E N T U N D E R T E S T 2.1 Information provided by the Client Please note, we do not take any responsibility for information provided by the client or his representative which may have an influence on the validity of the test results. 2.2 Sampling The customer is responsible for the choice of sample. Sample configuration, start-up and operation is carried out by the customer or according his/her instructions. 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 2.4 Equipment type portable wideband system 2.5 Short description of the equipment under test (EUT) The KINEXON tracking tag facilitates tracking of objects with a KINEXON RTLS system (Real Time Locating System). Number of tested samples: 2 Serial number: 256443 260919 Firmware version: production_tate_xtag_workertag_v5 2.6 Variants of the EUT There are no variants. 2.7 Operation frequency and channel plan The operating frequency band is 5925 MHz to 7250 MHz. Channel plan: 2.8 Transmit operating modes Modulation: variable pulse position modulation (PPM) in combination with binary phase shift keying (BPSK). Data rate: 6.8 Mbit/s Channel number f c (MHz) Channel 5 6489.6 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557KNX-HCTAG1 CSA Group Bayern GmbH File No. 80115860-03 Rev2, page 5 of 27 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.1, 2021-04-30 CSA Confidential 2.9 Antenna The following…
Text truncated - open the document above for the full version.
The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80115860-04 Rev2, page 1 of 12 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential R F − T E S T R E P O R T - Human Exposure - Type / Model Name : KNX-T6.1-1.2 / High-Capacity X-Tag Product Description : Tracking Tag Applicant : KINEXON Inc. Address : 200 S Wacker Dr Suite 3100 CHICAGO, IL 60606, U.S.A. Manufacturer : Kinexon GmbH Address : Schellingstraße 35 80799 MÜNCHEN, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE Test Report No. : 80115860-04 Rev2 22. September 2022 ______________________________________________________________________________________________ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557-KNXHCTAG1 CSA Group Bayern GmbH File No. 80115860-04 Rev2, page 2 of 12 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential Contents 1 T E S T S T A N D A R D S 3 2 E Q U I P M E N T U N D E R T E S T 4 2.1 Information provided by the Client 4 2.2 Sampling 4 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 4 2.4 Equipment type, category 4 2.5 Short description of the equipment under test (EUT) 4 2.6 Variants of the EUT 4 2.7 Operation frequency and channel plan 4 2.8 Transmit operating modes 4 2.9 Antennas 5 2.10 Power supply system utilised 5 3 T E S T R E S U L T S U M M A R Y 6 3.1 Revision history of test report 6 3.2 Final assessment 6 4 T E S T E N V I R O N M E N T 7 4.1 Address of the test laboratory 7 4.2 Environmental conditions 7 4.3 Statement of the measurement uncertainty 7 5 H U M A N E X P O S U R E 8 5.1 SAR test exclusion considerations 8 5.2 Exemption limits for routine evaluation - SAR evaluation 10 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 12 ATTACHMENT A as separate supplement The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557-KNXHCTAG1 CSA Group Bayern GmbH File No. 80115860-04 Rev2, page 3 of 12 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 1, Subpart I - Procedures Implementing the National Environmental Policy Act of 1969 Part 1, Subpart I, Section 1.1310 Radiofrequency radiation exposure limits Part 1, Subpart 2, Section 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. Part 1, Subpart 2, Section 2.1093 Radiofrequency radiation exposure evaluation: portable devices. KDB 447498 D01 RF Exposure procedures and equipment authorisation policies for mobile and portable devices, November 29, 2021. RSS-102, issue 5, March 2015, incl. Radio Frequency (RF) Exposure Compliance of Amendment 1, February 2021 Radiocommunication Apparatus (All Frequency Bands) Health Canada Notice, January 2021 Localized human exposure limits for radiofrequency fields in the range of 6 GHz to 300 GHz ISED Notice 2016-DRS0001 Applicability of Latest FCC RF Exposure KDB Procedures and September 20, 2016, updated July 2020 Other Procedures ISED Notice 2021-DRS0005 Introduction of an interim exemption limit for routine localized power July 20, 2021 density evaluations of transmitters operating in the 6 – 30 GHz frequency range ANSI C95.1: 2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz ETSI TR 100 028 V1.3.1: 2001-03, Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristics—Part 1 and Part 2 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557-KNXHCTAG1 CSA Group Bayern GmbH File No. 80115860-04 Rev2, page 4 of 12 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential 2 E Q U I P M E N T U N D E R T E S T 2.1 Information provided by the Client Please note, we do not take any responsibility for information provided by the client or his representative which may have an influence on the validity of the test results. 2.2 Sampling The customer is responsible for the choice of sample. Sample configuration, start-up and operation is carried out by the customer or according his/her instructions. 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 2.4 Equipment type, category portable UWB device 2.5 Short description of the equipment under test (EUT) The KINEXON tracking tag facilitates tracking of objects with a KINEXON RTLS system (Real Time Locating System). Number of tested samples: 1 Serial number: 255036 Firmware version: production_tate_xtag_workertag_v5 2.6 Variants of the EUT There are no variants. 2.7 Operation frequency and channel plan Operating range 1: 5925 MHz to 7250 MHz 2.8 Transmit operating modes Modulation: variable pulse position modulation (PPM) in combination with binary phase shift keying (BPSK) Data rate: 6.8 Mbit/s The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: 2ALC5-KNX-HCTAG1 IC: 25557-KNXHCTAG1 CSA Group Bayern GmbH File No. 80115860…
Text truncated - open the document above for the full version.
Page 1 of 4 Internal Test Setup Photos (FCC §15.250 / RSS-210) Extract from Test Report 80115860-03 issued by CSA Group Bayern GmbH UWB Bandwidth Page 2 of 4 Internal Radiated Emissions Page 3 of 4 Internal Page 4 of 4 Internal Peak Power Radiated
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.250 | 6.49 GHz - 6.49 GHz | - |

TAG for UWB localization system
Equipment Class
UWB - Ultra Wideband Transmitter
TAG for UWB localization system
Equipment Class
UWB - Ultra Wideband Transmitter
Anchor for UWB localization system
Equipment Class
UWB - Ultra Wideband Transmitter
UWB Tracking Tag with ePaper Display
Equipment Class
WBT - Wideband Transmitter
Tracking System
Equipment Class
WBT - Wideband Transmitter