2ALE7-MINIPRO-2Smart Body Fat Scale

Youpin (Shenzhen) Medical Electronics Co., Ltd
Smart Body Fat Scale - FCC ID 2ALE7-MINIPRO-2 - Youpin (Shenzhen) Medical Electronics Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 26, 2020
Application Purpose
Original Equipment
Date of Application
Nov 25, 2020
Equipment Note
Smart Body Fat Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Youpin (Shenzhen) Medical Electronics Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement: Th is device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Th is equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures: -Reo rient the receiving antenna. -In crease the separation between the equipment and receiver. -Co nnect the equipment into and outlet on a circuit different from that to which the receiver is connected. -Cons ult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

Attestation Statements

Product Name: Smart Body Fat Scale Model No.: Mini Pro-2, Mini-2, Mini-Genie-2, S1 Pro-2 FCC ID:2ALE7-MINIPRO-2 All models are electrically identical ,Only model no is different. <Signature> Name: Dan Li Title: Manager Applicant Company: PICOOC Technology Co., Ltd

Cover Letter(s)

DATE: 2020-11-18 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 AuthoritytoActas Agent On our behalf, I appoint BlueAsia of Technical Services(Shenzhen) Co.,Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen,China (Name of Agent c ompany name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also c ertify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application.For instances where our authorized agent signs the application for certification on ourbehalf, I acknowledge that all res ponsibility for complying with the terms and conditionsfor certification, still resides with PICOOC Technology Co., Ltd. Room 507, F/5, Wanwei Building, No.5 Industrial Road, NanShan District, Shenzhen, China (Applicant Name and address) < Signature> Nam e:Dan Li Title:/ Applicant Company:PICOOC Technology Co., Ltd.

External Photos

Model No.: Mini Pro-2

ID Label/Location Info

FCC ID:2ALE7-MINIPRO-2

Internal Photos

Model No.: Mini Pro-2

RF Exposure Info

RF Exposure Evaluation Statement Product Name: Smart Body Fat Scale Model No.:Mini Pro-2, Mini-2, Mini-Genie-2, S1 Pro-2 FCC ID:2ALE7-MINIPRO-2 1.1 RF Exposure Compliance Requirement 1.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 1.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation 17  The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion 1.1.3 EUT RF Exposure Operational Mode: BLE(worst case) Channel Maximum Peak Conducted Output Power (dBm) Tune up tolerance (dB) Maximum tune-up Power Calculated value Exclusion threshold (dBm) (mW) 2402 3.45 ±1 4.45 2.79 0.86 3.0 2442 3.77 ±1 4.77 3.00 0.94 2480 3.69 ±1 4.69 2.94 0.93 Conclusion: the calculated value ≤3.0, SAR is exempted.

Test Report

Page 1 of63 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Add:No. 448, Bulong Road, Bantian Street, Longgang District, Shenzhen, China Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TEST REPORT Product Name : Smart Body Fat Scale Brand Mark : PICOOC Model No. : Mini Pro-2, Mini-2, Mini-Genie-2, S1 Pro-2 FCC ID : 2ALE7-MINIPRO-2 Report Number : BLA-EMC-202010-A4001 Date of Sample Receipt : 2020/10/20 Date of Test : 2020/10/20 to 2020/11/12 Date of Issue : 2020/11/13 Test Standard : 47 CFR Part 15, Subpart C 15.247 Test Result : Pass Prepared for: PICOOC Technology Co., Ltd. Room 507, F/5, Wanwei Building, No.5 Industrial Road, NanShan District, Shenzhen, China Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. IOT Test Centre of BlueAsia No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China TEL: +86-755-23059481 Compiled by: Review by: Approved by: Date: 2020/11/13 Report No.: BLA-EMC-202010-A4001 Page 2 of63 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com REPORT REVISE RECORD Version No. Date Description 00 2020/11/13 Original Report No.: BLA-EMC-202010-A4001 Page 3 of63 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TABLE OF CONTENTS 1 TEST SUMMARY ........................................................................................................................................5 2 GENERAL INFORMATION .........................................................................................................................6 3 GENERAL DESCRIPTION OF E.U.T. .........................................................................................................6 4 TEST ENVIRONMENT ................................................................................................................................7 5 TEST MODE ................................................................................................................................................7 6 MEASUREMENT UNCERTAINTY ..............................................................................................................7 7 DESCRIPTION OF SUPPORT UNIT...........................................................................................................8 8 LABORATORY LOCATION .........................................................................................................................8 9 TEST INSTRUMENTS LIST ........................................................................................................................9 CONDUCTED BAND EDGES MEASUREMENT ............................................................................................. 12 LIMITS ............................................................................................................................................................................. 12 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 12 TEST DATA ........................................................................................................................................................................ 13 RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS ......................................................... 14 LIMITS ............................................................................................................................................................................. 14 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 15 PROCEDURE ................................................................................................................................................................... 15 TEST DATA ........................................................................................................................................................................ 17 CONDUCTED SPURIOUS EMISSIONS ........................................................................................................... 21 LIMITS ............................................................................................................................................................................. 21 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 21 TEST DATA ........................................................................................................................................................................ 22 POWER SPECTRUM DENSITY ....................................................................................................................... 23 LIMITS ............................................................................................................................................................................. 23 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 23 TEST DATA ........................................................................................................................................................................ 23 CONDUCTED PEAK OUTPUT POWER .......................................................................................................... 24 LIMITS ............................................................................................................................................................................. 24 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 24 TEST DATA ....…

Text truncated - open the document above for the full version.

Test Setup Photos

Model No.: Mini Pro-2

Contact Information

Applicant

yuanpeng meng
[email protected]86 755 86350847Fax: 86 755 86350847

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.38 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted

Other Applications from Youpin (Shenzhen) Medical Electronics Co., Ltd

Smart Body Weight Scale - FCC ID 2ALE7-BASIC - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-BASIC

Smart Body Weight Scale

May 09, 2023

Equipment Class

DTS - Digital Transmission System
Smart Body Weight Scale - FCC ID 2ALE7-MINILITE - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-MINILITE

Smart Body Weight Scale

May 07, 2023

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2ALE7-MINIPROU - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-MINIPROU

Smart Body Fat Scale

Aug 24, 2021

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2ALE7-MINIU - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-MINIU

Smart Body Fat Scale

Aug 10, 2021

Equipment Class

DTS - Digital Transmission System
AI Electric Toothbrush - FCC ID 2ALE7-T1 - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-T1

AI Electric Toothbrush

Apr 21, 2021

Equipment Class

DTS - Digital Transmission System