FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Youpin (Shenzhen) Medical Electronics Co., Ltd/
  3. 2ALE7-MINIPROU

2ALE7-MINIPROUSmart Body Fat Scale

Youpin (Shenzhen) Medical Electronics Co., Ltd
Smart Body Fat Scale - FCC ID 2ALE7-MINIPROU - Youpin (Shenzhen) Medical Electronics Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 24, 2021
Application Purpose
Original Equipment
Date of Application
Aug 18, 2021
Equipment Note
Smart Body Fat Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Youpin (Shenzhen) Medical Electronics Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Product Name: Smart Body Fat Scale Model No.:Mini Pro U, Mini Pro-2, Mini Pro V2.0, S1 Pro V2.0 FCC ID:2ALE7-MINIPROU All models are electrically identical ,only model no is different.

External Photos

Model No.: Mini Pro U

ID Label/Location Info

FCC ID : 2ALE7-MINIPROU

Internal Photos

Model No.: Mini Pro U

RF Exposure Info

RF Exposure Evaluation Statement Product Name: Smart Body Fat Scale Model No.:Mini Pro U, Mini Pro-2, Mini Pro V2.0, S1 Pro V2.0 FCC ID:2ALE7-MINIPROU 1.1 RF Exposure Compliance Requirement 1.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 1.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation 17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion 1.1.3 EUT RF Exposure Operational Mode: BLE Channel Maximum Peak Conducted Output Power (dBm) Tune up tolerance (dB) Maximum tune-up Power Calculated value Exclusion threshold (dBm) (mW) 2402 MHz -0.019 ±1 0.981 1.25 0.39 3 2442 MHz -0.274 ±1 0.726 1.18 0.37 2480 MHz -0.009 ±1 0.991 1.26 0.40 Conclusion: the calculated value ≤3.0, SAR is exempted.

Test Report

Page 1 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: SmartBodyFatScale BrandMark: PICOOC ModelNo.: MiniProU,MiniPro-2,MiniProV2.0, S1ProV2.0 FCCID: 2ALE7-MINIPROU ReportNumber: BLA-EMC-202108-A2302 DateofSampleReceipt: 2021/8/5 DateofTest: 2021/8/5to2021/8/9 DateofIssue: 2021/8/9 TestStandard: 47CFRPart15,SubpartC15.247 TestResult:Pass Preparedfor: PICOOCTechnologyCo.,Ltd Room504,WanweiBuilding,No5,industrial5road,Nanshan District,Shenzhen Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2021/8/9 ReportNo.:BLA-EMC-202108-A2302 Page 2 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002021/8/9Original ReportNo.:BLA-EMC-202108-A2302 Page 3 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY ....................................................................................................................................................... 5 2GENERALINFORMATION ...................................................................................................................................... 6 3GENERALDESCRIPTIONOFE.U.T. .................................................................................................................... 6 4TESTENVIRONMENT .............................................................................................................................................. 7 5TESTMODE ............................................................................................................................................................... 7 6MEASUREMENTUNCERTAINTY .......................................................................................................................... 7 7DESCRIPTIONOFSUPPORTUNIT ...................................................................................................................... 8 8LABORATORYLOCATION ..................................................................................................................................... 8 9TESTINSTRUMENTSLIST ..................................................................................................................................... 9 10CONDUCTEDBANDEDGESMEASUREMENT ............................................................................................... 13 10.1LIMITS ................................................................................................................................................................ 13 10.2BLOCKDIAGRAMOFTESTSETUP ...................................................................................................................... 13 10.3TESTDATA ............................................................................................................................................................ 14 11CONDUCTEDSPURIOUSEMISSIONS ............................................................................................................. 15 11.1LIMITS ................................................................................................................................................................ 15 11.2BLOCKDIAGRAMOFTESTSETUP ...................................................................................................................... 15 11.3TESTDATA ............................................................................................................................................................ 16 12POWERSPECTRUMDENSITY ........................................................................................................................... 17 12.1LIMITS ................................................................................................................................................................ 17 12.2BLOCKDIAGRAMOFTESTSETUP ...................................................................................................................... 17 12.3TESTDATA ............................................................................................................................................................ 17 13CONDUCTEDPEAKOUTPUTPOWER ............................................................................................................. 18 13.1LIMITS ................................................................................................................................................................ 18 13.2BLOCKDIAGRAMOFTESTSETUP ...................................................................................................................... 18 13.3TESTDATA ............................................................................................................................................................ 19 14MINIMUM6DBBANDWIDTH ............................................................................................................................... 20 14.1LIMITS ................................................................................................................................................................ 20 14.2BLOCKDIAGRAMOFTESTSETUP ...................................................................................................................... 20 14.3TESTDATA ............................................................................................................................................................ 20 ReportNo.:BLA-EMC-202108-A2302 Page 4 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:marketing@cb…

Text truncated - open the document above for the full version.

Test Setup Photos

Model No.: Mini Pro U

Contact Information

Applicant

yuanpeng meng
[email protected]86 755 86350847Fax: 86 755 86350847

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz998.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted

Other Applications from Youpin (Shenzhen) Medical Electronics Co., Ltd

Smart Body Weight Scale - FCC ID 2ALE7-BASIC - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-BASIC

Smart Body Weight Scale

May 09, 2023

Equipment Class

DTS - Digital Transmission System
Smart Body Weight Scale - FCC ID 2ALE7-MINILITE - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-MINILITE

Smart Body Weight Scale

May 07, 2023

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2ALE7-MINIU - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-MINIU

Smart Body Fat Scale

Aug 10, 2021

Equipment Class

DTS - Digital Transmission System
AI Electric Toothbrush - FCC ID 2ALE7-T1 - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-T1

AI Electric Toothbrush

Apr 21, 2021

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2ALE7-MINIPRO-2 - Youpin (Shenzhen) Medical Electronics Co., Ltd
2ALE7-MINIPRO-2

Smart Body Fat Scale

Nov 26, 2020

Equipment Class

DTS - Digital Transmission System