FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Accutime Watch Corp/
  3. 2ALPL-MIN4363

2ALPL-MIN4363Smart Watch

Accutime Watch Corp
Smart Watch - FCC ID 2ALPL-MIN4363 - Accutime Watch Corp
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 09, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Watch
Frequency Range
2402.00000000 - 2480.00000000
Company
Accutime Watch Corp
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ACCUTIME WATCH CORP 1001 Ave Of the Americas, New York, United States 10018 Attestation Statements Not Covered Entity Applicant & Not Covered Equipment To: Federal Communications Commission Date: Feb. 3, 26 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) & (ii) FCC ID: 2ALPL-MIN4363 Elockers (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List, established pursuant to § 1.50002 of reference chapter, as an entity producing “covered” communication equipment. The equipment for which authorization is sought is not “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List that prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature: Printed Name: Jack Shama Title: Manager Address: 1001 Ave Of the Americas, New York, United States 10018 Tel.: 212-686-9438 Email: [email protected]

Attestation Statements

1 | P a g e ACCUTIME WATCH CORP 1001 Ave Of the Americas, New York, United States 10018 Attestation Statements To: Federal Communications Commission Date: Feb. 3, 26 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Attestation of Compliance with FCC Covered List Software Requirements FCC ID: [2ALPL-MIN4363] Product Name: [Smart Watch] This letter serves as an attestation that the equipment identified above ☐ is / ☒ is not (select one) "covered" software as defined under the Federal Communications Commission (FCC) Covered List requirements, as outlined in FCC 22-84 and KDB 986446. Specifically, the undersigned certifies that the equipment for which authorization is sought: 1. Does not contain cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors, assignees, parents, subsidiaries, affiliates, or any entity that has rebranded or relabeled software produced by the aforementioned entities. 2. Does not have the capability to store, run, or deliver any software identified on the FCC Covered List, including but not limited to cybersecurity and anti-virus software. To support this attestation, the appendix evaluation documentation has been prepared and is included in the certification filing. This attestation is based on a thorough evaluation of the device's design, functionality, and software environment. The undersigned affirms that the information provided is accurate and complete to the best of their knowledge. Sincerely yours, Applicant Signature: Printed Name: Jack Shama Title: Manager Address: 1001 Ave Of the Americas, New York, United States 10018 Tel.: 212-686-9438 Email: [email protected] 2 | P a g e Evaluation regarding to the Covered List Software: Compliance Methodology Evaluation Process Results Device is Inherent compliance ☒ The Chipset(s) used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ The Memory used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ There is storage capacity limitation for store or install the Cybersecurity or anti-virus software. Compliance ☒ Operating system used is limited to run, install or deliver the Cybersecurity or anti-virus software. Compliance Device is not Inherent compliance ☐ Evaluation Based on Software Bill of Materials (SBoM) ☐ Evaluation Based on Scan for Software on the device ☐ Evaluation Based on Filesystem scan ☐ Evaluation Based on Running software check

Attestation Statements

ACCUTIME WATCH CORP 1001 Ave Of the Americas, New York, United States 10018 U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: Feb. 3, 26 Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2ALPL-MIN4363 [ACCUTIME WATCH CORP] (“the applicant”) certifies that, as of the date of the filing of the application, [ACCUTIME WATCH CORP] (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. [MIRAMONT SOLUTIONS LLC] ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: ACCUTIME WATCH CORP FRN: 0026401646 Address: 1001 Ave Of the Americas, New York, United States 10018 Signature: Contact Person: Jack Shama Tel: 212-686-9438 Email: [email protected] Applicant Company Name: ACCUTIME WATCH CORP FRN: 0026401646 Address: 1001 Ave Of the Americas, New York, United States 10018 Signature: Contact Person: Jack Shama Tel: 212-686-9438 Email: [email protected]

Cover Letter(s)

ACCUTIME WATCH CORP 1001 Ave Of the Americas, New York, United States 10018 2/3/2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request for: FCC ID: 2ALPL-MIN4363 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request permanent confidential treatment of the exhibits accompanying this certification application as outlined below : ⎯ Block Diagram ⎯ Schematics ⎯ Operational Description The above exhibits contain trade secrets and/or proprietary information that are not publicly available and materials that the Applicant has spent considerable efforts in developing. Public disclosure of these may be harmful to the Applicant and give an unfair advantage to competitors on the market. Pursuant to DA 04-1705, the applicant also requests temporary confidential treatment of the exhibits outlined below for a period of (up to 180) days from the date of equipment authorization and prior to marketing in the United States to prevent the premature release of any sensitive information. Applicant is aware of their responsibility to notify DERYCOM in the event information regarding the product or the product is made available to the public before the requested period has expired. ⎯ User Manual ⎯ Internal Photos ⎯ Test Setup Photos Sincerely, (Signature) Applicant Signature: Printed Name: Jack Shama Title: Manager Address: 1001 Ave Of the Americas, New York, United States 10018 Tel.: 212-686-9438 Email: [email protected]

Cover Letter(s)

ACCUTIME WATCH CORP 1001 Ave Of the Americas, New York, United States 10018 Date: Feb. 3, 26 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID: 2ALPL-MIN4363 I, the undersigned, hereby authorize (Shenzhen DL Testing Technology Co., Ltd.) to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by (Shenzhen DL Testing Technology Co., Ltd.) shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by DERYCOM CERTIFICATION SERVICES, INC., still resides with (ACCUTIME WATCH CORP). We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. Sincerely, Applicant Signature: Printed Name: Jack Shama Title: Manager Address: 1001 Ave Of the Americas, New York, United States 10018 Tel.: 212-686-9438 Email: [email protected]

Cover Letter(s)

ACCUTIME WATCH CORP Model Difference Product description:Smart Watch Model name: MIN4363, SNC4488, HP4168, PEA4053, BAB4128, TMR4221, Z15CJ Trade Name: N/A All the model are the same circuit and RF module, except model names and appearance color. Regards Sincerely Client’s signature: Jack Shama Client’s name / title: Manager Contact information / address: 1001 Ave Of the Americas, New York, United States 10018

External Photos

FCC ID: 2ALPL-MIN4363 EUT PHOTO(External Photos) FCC ID: 2ALPL-MIN4363 FCC ID: 2ALPL-MIN4363 FCC ID: 2ALPL-MIN4363 FCC ID: 2ALPL-MIN4363

ID Label/Location Info

Label & label location 20mm*10mm FCC ID: 2ALPL-MIN4363 Label location

RF Exposure Info

FCC ID: 2ALPL-MIN4363 RF Exposure Evaluation According to WS-1 General RF Exposure Guidance v06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Here, For 2.4G: Mode Max Power(dBm) Tune up Power (dBm) Max. Tune up Power (dBm) Max. Tune up Power (mW) Frequency (MHz) Min. distance (mm) Calc. thresholds limit BLE 2M 5.9 6±1 7 5.01 2480 5 1.58 3.0 Result: No Standalone SAR test is required.

Test Report

Shenzhen Yixiantong Cable Co., Ltd. Address: Building 21, Wanfeng 98 Industrial Zone, Shajing Street, Bao'an District, Shenzhen City 天线规格承认书 Antenna Specification for Approval 客户名称 CustomerName:Shenzhen Mobang Technology Co., Ltd. 产品名称: ProductName: 2.4GANT 客户型号: ProductName: 产品料号: Part NO.: C10- 35- 2.5 制 表 : WriteBy:庄杰彬 日 期: IssuedDate: 2021- 10-08 客 户: 工程R& D Dept 采购Business Dept 承认 Approved By 一线通 研发R& D Dept 工程 Engineer Dept 审核 Approval 庄彩虹 庄杰彬 庄杰彬 Product Specification A. ElectricalCharacteristics Frequency 2400MHz ~2500MHz VSWR<3.0 Efficiency >30% Impedance 50 Ohm Polarization Line Gain 0DBi B. Material & MechanicalCharacteristics Material of Radiator Cu Cable Type 1.0 19P 红 Connector Type : NO Dimension C. Environmental Operation Temperature - 30 °C ~ + 80 ° CStorage Temperature - 30 ° C~+ 85 °C Test Equipment & Conditions 1. NetworkAnalyzers: Agilent 8753D 5071C 2. Communications TestSet: Agilent E5525C 3. 3D Chamber TestSystem Effiency& Gain Effiency& Gain 2.40 - 0.00 2.440 - 0. 11 2.48 - 0. 13 Radiation Pattern:

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260120008R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 46 FCC Part 15C Test Report FCC ID: 2ALPL-MIN4363 Applicant: ACCUTIME WATCH CORP Address: 1001 Ave Of the Americas, New York, United States 10018 Manufacturer: ACCUTIME WATCH CORP Address: 1001 Ave Of the Americas, New York, United States 10018 EUT: Smart Watch Trade Mark: N/A Model Number: MIN4363, SNC4488, HP4168, PEA4053, BAB4128, TMR4221, Z15CJ Date of Receipt: Jan. 12, 2026 Test Date: Jan. 12, 2026 to Jan. 17, 2026 Date of Report: Jan. 17, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Building C, Shuanghuan, No.8, Baoqing Roa Baolong Industrial Zone, Baolong Street, Longgang Shenzhen, Guangdong, China. Applicable Standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2020 Test Result: Pass Report Number: DLE-260120008R Prepared (Test Engineer): Dimon Tan Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260120008R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 46 Table of Contents Page 1.VERSION ............................................................................................................... 4 2. SUMMARY OF TEST RESULTS ........................................................................... 5 2.1 TEST FACILITY ...................................................................................................................... 6 2.2 MEASUREMENT UNCERTAINTY ......................................................................................... 6 3. GENERAL INFORMATION ................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT ....................................................................................... 7 3.2 DESCRIPTION OF TEST MODES ......................................................................................... 8 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED ..................... 9 3.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) ............................................... 9 3.5 EQUIPMENTS LIST FOR ALL TEST ITEMS ....................................................................... 10 4. EMC EMISSION TEST ......................................................................................... 11 4.1 CONDUCTED EMISSION MEASUREMENT......................................................................... 11 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS ............................................................ 11 4.1.2 TEST PROCEDURE ......................................................................................................... 11 4.1.3 DEVIATION FROM TEST STANDARD ............................................................................ 11 4.1.4 TEST SETUP ................................................................................................................... 12 4.1.5 EUT OPERATING CONDITIONS .................................................................................... 12 4.2.1 RADIATED EMISSION LIMITS ........................................................................................ 15 4.2.2 TEST PROCEDURE ........................................................................................................ 16 4.2.3 DEVIATION FROM TEST STANDARD ........................................................................... 16 4.2.4 TEST SETUP ................................................................................................................... 16 4.2.5 EUT OPERATING CONDITIONS .................................................................................... 17 BETWEEN 30MHZ – 1GHZ .................................................................................... 18 1GHZ~25GHZ ......................................................................................................... 20 5.RADIATED BAND EMISSION MEASUREMENT ................................................. 24 5.1 TEST REQUIREMENT: ...................................................................................................... 24 5.2 TEST PROCEDURE ........................................................................................................... 24 5.3 DEVIATION FROM TEST STANDARD .............................................................................. 25 5.4 TEST SETUP ...................................................................................................................... 25 5.5 EUT OPERATING CONDITIONS ....................................................................................... 25 5.6 TEST RESULT .................................................................................................................... 26 6.POWER SPECTRAL DENSITY TEST ................................................................. 27 6.1 APPLIED PROCEDURES / LIMIT ...................................................................................... 27 6.2 TEST PROCEDURE ........................................................................................................... 27 6.3 DEVIATION FROM STANDARD ........................................................................................ 27 6.4 TEST SETUP ...................................................................................................................... 27 6.5 EUT OPERATION CONDITIONS ....................................................................................... 27 6.6 TEST RESULT .................................................................................................................... 28 7. 6DB OCCUPIED BANDWIDTH ..........…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jack Shama
[email protected]Fax: 212-685-6627

Technical Contact

ACCUTIME WATCH CORPJack Shama
[email protected]

1001 Ave Of the Americas · New York, 10018 · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.89 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from Accutime Watch Corp

Smart watch - FCC ID 2ALPLI8PRO - Accutime Watch Corp
2ALPLI8PRO

Smart watch

Dec 03, 2023

Equipment Class

DTS - Digital Transmission System