Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 03, 2023
Application Purpose
Original Equipment
Date of Application
Dec 03, 2023
Equipment Note
Smart watch
Frequency Range
2402.00000000 - 2480.00000000
Company
Accutime Watch Corp
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Adapt to platform requirements: Initial use Watch and APP c。nnection watch device. between the mobile phone ’Android 5.0 and above mobile phones To ensure the normal use eThe permissions during e M。bile phone Bluet,。。th and the watch may be ti IDS 9.0 and above mobile phones 。f the watch, please charge the APP installation process connection: Blueto。th unstable. You can turn off the * Support Bluetooth BT 3.0 it first. are fully agreed, and the must be turned on。n the Bluetooth of the mobile APP download method: The contact of the charging watch and the mobile phone watch side, enter the mobile phone and rec。nnectit again, 撞撞 clip connected to the power must be connected to the phone Bluetooth, search fo「 or reset the watch to the supply can be charged with factory settings, such as The the contact on the back of APP and the mobile phone the Bluet。oth device of the watch is in a dead state, you Bluetooth to achieve all model name, and click the watch. functions. Connect to pai仁 can press and hold the power Smart watch manual Note: The reverse contact button for 10 seconds t。 1.105/Android pho门euse厄:scan the • APP connection method: esimple solution t。 above QR code to download and install point will cause the battery restart the watch. the application. to short-circuit. open the APP and m。bile common Bluetooth eH。w t。c。nnectBT3.0 2. Android: Search for ”H「yFine “ through phone Bluetooth, the APP problems: Due to the lack Bluetooth: the Google Play to download and in处all 「emindsyou to enable the the application. of uniformity in the Enter the Bluet。oth terminal 3. Apple: Search for "HryFine '’ through the notification point to confirm. Bluetooth protocol of of the mobile phone and App store to download and install the app. Click to add a device, search various mobile phone search for Hry3.0 binding. for the device name and click brands, sometimes the • How to verify that the Connect to connect to the Bluet。oth connection Bluetooth in degrees. device. will light up when you raise phone system to sea「ch and protect it from damage. exposure. • Stopwatch: start • Brightness: can set the your wrist, and it will turn o忏 connect Hry3.0 after it is • You can wipe the surface This product does not stopwatch timing and end brightness size and backlight when you put it down turned on, and disconnect it 。f the watch with a damp support IP68 waterproof, timing. off time. • Language: After connecting when it is turned off doth, and use mild soap and does not su ppo同rain, hand • Alarm bell: You can set a • QR c。de: QR code to the APP, you can set the wate「to remove oil or dust. washing, swimming wea几 custom alarm clock on the downloaded by mobile APP. language on the APP side, and Precautions for use: • Do not expose the watch hot showers or saunas, etc., APP, and the watch will • Reset: Let your device the language can be • Not suitable for bathing to an environment with can not be worn, and synchronized to the watch and swimming. vibrate to remind you at the reset and clear data, such as afte「setting;。r switch the • Please connect the watch strong chemical substances, cannot prevent wate「vapo仁 point. pedometer sleep, etc. language on the watch side, when synchronizing data. such as gasoline, cleaning If the watch is damaged due eSettings: You can set to • Flashlight: Turn on the that is, it will als。be solvents, propanol, alcohol to water ingress due to use turn on or off the vibration flashlight function, the screen synchronized to the APP side • Use the built-in charging 。r insect repellent, chemical in violation of the and raise the wrist to of the bracelet will be bright • Dial push: enter the APP cable to charge. substances will damage the instructions, our company brighten the screen. and white. end dial function, you can • Do not expose the watch sealing of the watch and the • Raise your hand t。brigh to high moisture, extremely will not provide a free • style: You can set and view my dial and local dial; surface of the case. warranty. change the UI style. ten the screen: After turning you can als。pushDIV dials h igh or extremely low • Avoid your watch from • About: Display the MAC on the raising of thehand to and dialmalls to the watch end temperatures fo「a long time. being exposed to strong serial code, Bluetooth name, brighten the screen, when you • Dual mode switch: BT Watch maintenance: shocks and extreme heat and ve「sion number of this wear the bracelet, the screen switch, enter the m。bile • Do not scratch the sen so几 c。nnecti。n is successful: long p陀ss for power on and •c。ntact:After the bra eel The bluetooth icon in the 。忏and restart et is successfully connected upper left corner of the main • Clock interface: Swipe to the APP, you can add a menu is oval to indicate that left and right on the dial contact in the APP. After the the Bluetooth connection is interface to preview or switch contact is successfully added, successful. Use the watch to dials, swipe up on the quick the phone b。ok of the click to find the phone or notification bar interface, and bracelet will be displayed enter the APP to find the swipe down to enter the synchronously. Click the watch. If there is vibration, message notification list contact in the phone book it means that theAPP is on the bracelet to make a connected successfully. Watch function call (Note: The bracelet introduction needs Connect mobile Watch operating in estandby interface: enter phone Bluetooth). structions: the standby interface. ecall record: can display •Power button: Up key: • Dial pad: connect to the the call record of the short press to enter menu mobile phone to dial out via wristband, click the phone and return, down key: wake Bluetooth, and you can number to dial. up/turn o忏the screen and make a call on the watch side. e Information: The content c。mm。n problem: Is the Bluetooth connection automatically overwritten to Can ’ t find the watch? always on? Will there be any generate the latest data, so • Answer: Because the data if it is tur…

Text truncated - open the document above for the full version.

Attestation Statements

Attestation Statements (2023/11/23) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2ALPLI8PRO) (Accutime Watch Corp), the undersigned, hereby authorize Accutime Watch Corp to act as our designated U.S. agent for service of process, (Accutime Watch Corp) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Accutime Watch Corp accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company Name: Accutime Watch Corp Address: 1001 Ave Of the Americas, New York, New York 10018, United States Contact Name: Jack Shama FRN: 0026401646 Telephone No: (212) 686-9438 Email: [email protected] Signature [Jack Shama] U.S. Agent Information: Company Name: Accutime Watch Corp Address: 1001 Ave Of the Americas, New York, New York 10018, United States Contact Name: Jack Shama FRN: 0026401646 Telephone No: (212) 686-9438 Email: [email protected] Signature [Jack Shama]

Attestation Statements

(Accutime Watch Corp) (2023.11.23) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2ALPLI8PRO) [Accutime Watch Corp] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Jack Shama (Accutime Watch Corp) (2023.11.23) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2ALPLI8PRO) [Accutime Watch Corp] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Jack Shama

Cover Letter(s)

Accutime Watch Corp 2023.11.23 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title: Jack Shama / Manager Contact information / address: 1001 Ave Of the Americas, New York, New York 10018, United States

Cover Letter(s)

Accutime Watch Corp 2023.11.23 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Smart watch Trademark: N/A MODEL: HK4208AZ, BAR4000AZ, SNC4386MAZ FCC ID: 2ALPLI8PRO To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title: Jack Shama / Manager Contact information / address: 1001 Ave Of the Americas, New York, New York 10018, United States

External Photos

External Photos

ID Label/Location Info

Label & label location FCC ID: 2ALPLI8PRO

Internal Photos

Internal Photos Antenna

RF Exposure Info

RF EXPOSURE EVALUATION METHOD FCC ID: 2ALPLI8PRO Applicable standard: In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BT: Modulation Frequency Maximum Conducted Output Power(PK) Conducted Output Power Limit (MHz) (dBm) dBm GFSK 2402 -1.78 21 2441 -1.73 21 2480 -2.28 21 π/4 DQPSK 2402 0.37 21 2441 0.41 21 2480 -0.1 21 8DPSK 2402 0.85 21 2441 0.93 21 2480 0.37 21 max possible output power (PK,conducted):1±1dBm 0dBi logarithmic terms convert to numeric result is nearly1 2dBm=1.58mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.402=0.490≤3.0 2441MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.441=0.494≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.48=0.498≤3.0 BLE: Modulation Frequency Maximum Conducted Output Power(PK) Conducted Output Power Limit (MHz) (dBm) dBm GFSK 2402 -1.59 21 2440 -1.59 21 2480 -2.19 21 max possible output power (PK,conducted):0±1dBm 0dBi logarithmic terms convert to numeric result is nearly 1 1dBm=1.26mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.402=0.391≤3.0 2440MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.440=0.394≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.26/5*√2.48=0.397≤3.0

Test Report

 Mo Fre Ga MA Im An Ma odel Name equency ain (dBi) AX. Gain pedance tenna Leng a nufacturer& address 2400 -1.02 gth A Antenn 0MHz 2dBi Antenna Ph XOZ na Speci 2.4G 2450 -0.45 hoto & Le fication G FHSS AN 0MHz 5dBi 0 dBi 50 Ω 26.8mm ength (mm NT 2500 0 dBi m) MHz i Shenzhen Ksu Electronics Co., LTD 5F, B1 Building, Xujingchang Science and Technology Industrial Park, 39 Haoye Road, Fuhai Street, Baoan District, Shenzhen, Guangdong Province YOZZ XOYY 

Test Report

No.:BCTC/RF-EMC-005 Page: 1 of 43 Edition:B.0 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2311372734-2E Applicant: Accutime Watch Corp Product Name: Smart watch Model/Type Reference: HK4208AZ Tested Date: 2023-11-21 to 2023-11-24 Issued Date: 2023-11-24 Report No.: BCTC2311372734-2E No.:BCTC/RF-EMC-005 Page: 2 of 43 Edition:B.0 FCC ID: 2ALPLI8PRO The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Smart watch Trademark: N/A Model/Type Reference: HK4208AZ BAR4000AZ, SNC4386MAZ Prepared For: Accutime Watch Corp Address: 1001 Ave Of the Americas, New York, New York 10018, United States Manufacturer: ShenZhen KY Technology Co., Ltd Address: B1 Building 5th floor XuJingChang Industry zoom, Fuhai road, Baoan, SZ. 518103 Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2023-11-21 Sample Tested Date: 2023-11-21 to 2023-11-24 Issue Date: 2023-11-24 Report No.: BCTC2311372734-2E Test Standards: FCC Part15.247 ANSI C63.10-2013 Test Results: PASS Remark: This is Bluetooth BLE radio test report. Tested by: Approved by: Shanshan. Zhang / Project Handler Zero Zhou/Reviewer Report No.: BCTC2311372734-2E No.:BCTC/RF-EMC-005 Page: 3 of 43 Edition:B.0 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Summary ....................................................................................................... 6 3. Measurement Uncertainty ..................................................................................... 7 4. Product Information And Test Setup ..................................................................... 8 4.1 Product Information ............................................................................................... 8 4.2 Test Setup Configuration ...................................................................................... 9 4.3 Support Equipment ............................................................................................... 9 4.4 Channel List ........................................................................................................ 10 4.5 Test Mode ........................................................................................................... 10 4.6 Table of parameters of text software setting ....................................................... 10 5. Test Facility And Test Instrument Used ............................................................... 11 5.1 Test Facility ......................................................................................................... 11 5.2 Test Instrument Used .......................................................................................... 11 6. Conducted Emissions .......................................................................................... 13 6.1 Block Diagram Of Test Setup .............................................................................. 13 6.2 Limit .................................................................................................................... 13 6.3 Test procedure .................................................................................................... 13 6.4 EUT Operating Conditions .................................................................................. 13 6.5 Test Result .......................................................................................................... 14 7. Radiated Emissions ............................................................................................. 16 7.1 Block Diagram Of Test Setup .............................................................................. 16 7.2 Limit .................................................................................................................... 17 7.3 Test procedure .................................................................................................... 18 7.4 EUT operating Conditions ................................................................................... 19 7.5 Test Result .......................................................................................................... 19 8. Radiated Band Emission Measurement And Restricted Bands Of Operation ..... 23 8.1 Block Diagram Of Test Setup .............................................................................. 23 8.2 Limit .................................................................................................................... 23 8.3 Test Procedure ................................................................................................... 24 8.4 EUT Operating Conditions .................................................................................. 24 8.5 Test Result .......................................................................................................... 25 9. Power Spectral Density Test ............................................................................... 26 9.1 Block Diagram Of Test Setup .............................................................................. 26 9.2 Limit .................................................................................................................... 26 9.3 Test procedure .................................................................................................... 26 9.4 EUT Operating Conditions .................................................................................. 26 9.5 Test Result .....................…

Text truncated - open the document above for the full version.

Test Report

Accutime Watch Corp Model Difference 2023/11/23 EUT NAME: Smart watch FCC ID: 2ALPLI8PRO Trademark: N/A MODEL: HK4208AZ BAR4000AZ, SNC4386MAZ All the models are the same circuit and RF module, except model number and appearance color. Regards Sincerely Client’s signature: Client’s name / title: Jack Shama / Manager Contact information / address: 1001 Ave Of the Americas, New York, New York 10018, United States

Test Setup Photos

Conducted emissions Radiated Measurement Photos

Contact Information

Applicant

Jack Shama
[email protected]212-686-9438Fax: 212-685-6627

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz690.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

Other Applications from Accutime Watch Corp

Smart Watch - FCC ID 2ALPL-MIN4363 - Accutime Watch Corp
2ALPL-MIN4363

Smart Watch

Feb 09, 2026

Equipment Class