FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NLU Products, LLC dba BGZ brands/
  3. 2ALQR-CTT5701

2ALQR-CTT5701Portable 360 Security Camera

NLU Products, LLC dba BGZ brands
Portable 360 Security Camera - FCC ID 2ALQR-CTT5701 - NLU Products, LLC dba BGZ brands
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 08, 2021
Application Purpose
Original Equipment
Date of Application
Mar 08, 2021
Equipment Note
Portable 360 Security Camera
Frequency Range
2412.00000000 - 2462.00000000
Company
NLU Products, LLC dba BGZ brands
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

should be placed on a horizontal plane. can not be used when carrying, FCC ID:2ALQR-CTT5701 Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Attestation Statements

NLU Products, LLC dba BGZ brands Model difference statement Product Name: Portable 360°Security Camera Model N o.: 5701-00T, 5701-001, 5701-002, 5701-003, 5701-004, 5701-005, 5701-006, 5701-007, 5701-008, 5701- 009, 5701- 00P, 5701-00A, 5701-00V We (NLU Products, LLC dba BGZ brands, 2801 N Thanksgiving Way #300,Lehi, UT 84043, U.S.A.) hereby state that all models above are identical in interior structure, electrical circuits and components, and just the model and color are different for marking requirement. Signature: Name / title: Ryan Clark / Controller Tel: 801-922-5810 Email: [email protected] Date: 2.5.2021

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization < NLU Products, LLC dba BGZ brands > Company: NLU Products, LLC dba BGZ brands Address: 2801 N Thanksgiving Way #300,Lehi, UT 84043, U.S.A. Product Name: Portable 360 Security Camera Model Number: 5701-00T, 5701-001, 5701-002, 5701-003, 5701-004, 5701- 005, 5701-006, 5701-007, 5701-008, 5701- 009, 5701- 00P, 5701-00A, 5701-00V FCC Identifier: 2ALQR-CTT5701 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Ryan Clark Date: 3/9/21 Title: Controller Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 < NLU Products, LLC dba BGZ brands > Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2/5/21 Subject: Request for Confidentiality FCC ID: 2ALQR-CTT5701 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Ryan Clark Title: Controller

External Photos

1 - Page 1 of 3 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model 5701-00T) Photo 2 1 - Page 2 of 3 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 1 - Page 3 of 3 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 5 Photo 6 ----END OF REPORT----

Internal Photos

1 - Page 1 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model 5701-00T) Photo 2 1 - Page 2 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 1 - Page 3 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 5 Photo 6 FPC antenna 1 - Page 4 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 7 Photo 8 1 - Page 5 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 9 Photo 10 1 - Page 6 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 11 Photo 12 1 - Page 7 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 13 Photo 14 1 - Page 8 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 15 Photo 16 1 - Page 9 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 17 Photo 18 1 - Page 10 of 10 - Report No.: MTi20031912-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 19 Photo 20 ----END OF REPORT----

RF Exposure Info

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China MPE REPORT FCC ID: 2ALQR-CTT5701 Date of issue: Dec. 30, 2020 Report number: MTi20031912-5E2 Sample description: Portable 360°Security Camera Model(s): 5701-00T, 5701-001, 5701-002, 5701-003, 5701-004, 5701- 005, 5701-006, 5701-007, 5701-008, 5701- 009, 5701- 00P, 5701-00A, 5701-00V Applicant: NLU Products, LLC dba BGZ brands Address: 2801 N Thanksgiving Way #300, Lehi, UT 84043, U.S.A. Date of test: Apr. 22, 2020 to June 30, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 4 - Report No.: MTi20031912-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China TEST RESULT CERTIFICATION Applicant’s name: NLU Products, LLC dba BGZ brands Address: 2801 N Thanksgiving Way #300, Lehi, UT 84043, U.S.A. Manufacture's name: CTT Co., Ltd Address: Building 2 of Industril park No 197 Xinhua Blvd Tongqiao town Zhongkai High-teck zone Huizhou, Guangdong, China Product name: Portable 360°Security Camera Trademark: BodyGuardz Model and/or type reference: 5701-00T Serial model: 5701-001, 5701-002, 5701-003, 5701-004, 5701-005, 5701-006, 5701-007, 5701-008, 5701- 009, 5701- 00P, 5701-00A, 5701-00V RF exposure procedures: KDB 447498 D01 v06 This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Danny Xu June 30, 2020 Reviewed by: Leo Su Dec. 30, 2020 Approved by: Tom Xue Dec. 30, 2020 - Page 3 of 4 - Report No.: MTi20031912-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) MPE Calculation Method Friis transmission formula: Pd= (Pout*G)\ (4*pi*R 2 ) Where Pd= Power density in mW/cm2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1415926 R= distance between observation point and center of the radiator in cm(20cm) Pd the limit of MPE, 1mW/cm2. If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. - Page 4 of 4 - Report No.: MTi20031912-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Measurement Result WIFI: Operation Frequency: WIFI 802.11b/g/n HT20: 2412-2462MHz, 802.11n HT40: 2422-2452MHz, Power density limited: 1mW/ cm 2 Antenna Type: Wifi Antenna: FPC Antenna; WIFI antenna gain: 1.7dBi R=20cm mW=10^(dBm/10) antenna gain Numeric=10^(dBi/10)= 10^(1.7/10)=1.48 Channel Freq. (MHz) modulation conducted power Tune- up power Max Antenna Evaluation result at 20cm Power density Limits (dBm) (dBm) tune-up power Gain Power density(mW/cm2 ) (mW/cm2) (dBm) (mW) Numeric Ant A Ant A Ant A Ant A Ant A Ant A 2412 802.11b 13.52 14±1 15 31.62 1.48 0.00931 1 2437 14.5 14±1 15 31.62 1.48 0.00931 1 2462 14.05 14±1 15 31.62 1.48 0.00931 1 2412 802.11g 12.56 12±1 13 19.95 1.48 0.00587 1 2437 12.4 12±1 13 19.95 1.48 0.00587 1 2462 12.04 12±1 13 19.95 1.48 0.00587 1 2412 802.11n H20 11.6 12±1 13 19.95 1.48 0.00587 1 2437 12.31 12±1 13 19.95 1.48 0.00587 1 2462 12.2 12±1 13 19.95 1.48 0.00587 1 2422 802.11n H40 11.51 11±1 12 15.84 1.48 0.00467 1 2437 11.83 11±1 12 15.84 1.48 0.00467 1 2452 11.81 11±1 12 15.84 1.48 0.00467 1 Conclusion: For the max result: 0.00931≤ 1.0 for 1g SAR, No SAR is required. ----END OF REPORT----

Test Report

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Test Report FCCID: 2ALQR-CTT5701 Date of issue: Dec. 30, 2020 Report number: MTi20031912-5E1 Sample description: Portable 360°Security Camera Model(s): 5701-0 0 T, 5701-001, 5701-002, 5701-003, 5701-004, 5701-005, 5701-006, 5701-007, 5701-008, 5701- 009, 5701- 00P, 5701-00A, 5701-00V Applicant: NLU Products, LLC dba BGZ brands Address: 2801 N Thanksgiving Way #300, Lehi, UT 84043, U.S.A. Date of test: Apr. 22, 2020 to June 30, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 57 - Report No.: MTi20031912-5E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Table of Contents 1 GENERAL INFORMATION .......................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................... 5 1.2 OPERATION CHANNEL LIST .............................................................................................................................................. 6 1.3 TEST CHANNEL LIST ....................................................................................................................................................... 6 1.4 ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 6 1.5 DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 6 2 SUMMARY OF TEST RES U LT S .................................................................................................................................... 8 3 TEST FACILITIES AND ACCREDITATIONS ..................................................................................................................... 9 3.1 TEST LABORATORY ........................................................................................................................................................ 9 3.2 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 9 3.3 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 9 3.4 TEST SOFTWARE ........................................................................................................................................................... 9 4 EQUIPMENT LIST .................................................................................................................................................... 10 5 TEST RESULT ........................................................................................................................................................... 12 5.1 ANTENNA REQUIREMENT ............................................................................................................................................. 12 5.1.1 Standard requirement ....................................................................................................................................... 12 5.1.2 EUT antenna ..................................................................................................................................................... 12 5.2 PEAK OUTPUT POWER ................................................................................................................................................. 13 5.2.1 Limit .................................................................................................................................................................. 13 5.2.2 Test setup .......................................................................................................................................................... 13 5.2.3 Test procedure ................................................................................................................................................... 13 5.2.4 Te s t results......................................................................................................................................................... 14 5.3 POWER SPECTRAL DENSITY ........................................................................................................................................... 15 5.3.1 Limit .................................................................................................................................................................. 15 5.3.2 Test setup .......................................................................................................................................................... 15 5.3.3 Test procedure ................................................................................................................................................... 15 5.3.4 Test results......................................................................................................................................................... 16 5.4 CONDUCTED EMISSION ................................................................................................................................................ 20 5.4.1 Limits ..........................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: 5701-00T Radiated emission Conducted emission

Contact Information

Applicant

Ryan Clark(Controller)
[email protected]801-922-5810Fax: 801-495-3516

Technical Contact

Shenzhen Microtest Co., LtdSmith Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Selby Liao
[email protected]0755-88850135-1193

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz28.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz bandwidth.

Other Applications from NLU Products, LLC dba BGZ brands

5K Type C & Lightning Portable Power Bank Keychain - FCC ID 2ALQR-AWPB5K - NLU Products, LLC dba BGZ brands
2ALQR-AWPB5K

5K Type C & Lightning Portable Power Bank Keychain

Sep 14, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
3 in 1 wireless charger - FCC ID 2ALQR-31MTC - NLU Products, LLC dba BGZ brands
2ALQR-31MTC

3 in 1 wireless charger

Aug 08, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Portable Over-Door Camera - FCC ID 2ALQR-CTT5801 - NLU Products, LLC dba BGZ brands
2ALQR-CTT5801

Portable Over-Door Camera

May 19, 2021

Equipment Class

DTS - Digital Transmission System
Lantern - FCC ID 2ALQR-BLDCTT20 - NLU Products, LLC dba BGZ brands
2ALQR-BLDCTT20

Lantern

Jan 03, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Lander 6000mAh WRLS - FCC ID 2ALQR-CA6CML20 - NLU Products, LLC dba BGZ brands
2ALQR-CA6CML20

Lander 6000mAh WRLS

Dec 03, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz