FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. OKURA USA INC./
  3. 2AM3K-STZ-W202

2AM3K-STZ-W202WIRELESS MICROPHONE

OKURA USA INC.
WIRELESS MICROPHONE - FCC ID 2AM3K-STZ-W202 - OKURA USA INC.
Click to zoom

Application Details

Equipment Class
DWM - Part 15 Wireless Microphone
Date of Grant
Sep 18, 2024
Application Purpose
Original Equipment
Date of Application
Sep 18, 2024
Equipment Note
WIRELESS MICROPHONE
Frequency Range
470.20000000 - 607.80000000
Company
OKURA USA INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.

Attestation Statements

OKURA USA INC. 1195 NW. 97 AVENUE.MIAMI Florida United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-9-19 To whom it may concern: We, OKURA USA INC., hereby certify that the equipment for which authorization is sought (FCC ID: 2AM3K-STZ-W202) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature GONZALO J PALENZUELA Manager OKURA USA INC. 62_[model] CoveredEqu_2.911(d)(5 )(i) and (ii) - U, V03

Attestation Statements

OKURA USA INC. 1195 NW. 97 AVENUE.MIAMI Florida United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-9-19 U.S. Agent Designation OKURA USA INC. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AM3K-STZ-W202): Name and company of U.S. agent: OKURA USA INC. Physical U.S. address of agent: 1195 NW. 97 AVENUE.MIAMI Florida United States FRN of U.S. agent: 0026702597 Email address of U.S. agent: [email protected] OKURA USA INC. acknowledges their obligation to accept service of process on behalf of OKURA USA INC.. OKURA USA INC. with the FRN [0026702597] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature GONZALO J PALENZUELA Manager OKURA USA INC. Signature GONZALO J. PALENZUELA Manager OKURA USA INC. 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-9-19> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AM3K-STZ-W202 STZ-W202 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: GONZALO J PALENZUELA/Manager Company: OKURA USA INC. Address: 1195 NW. 97 AVENUE.MIAMI Florida United States Phone: 305-592-2616 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

OKURA USA INC. 1195 NW. 97 AVENUE.MIAMI Florida United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-9-19 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AM3K-STZ-W202 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: GONZALO J PALENZUELA/Manager Company: OKURA USA INC. Address: 1195 NW. 97 AVENUE.MIAMI Florida United States Phone: 305-592-2616 Fax: N/A E-Mail: [email protected]

External Photos

FCC ID: 2AM3K-STZ-W202 External Photos of the EUT FCC ID: 2AM3K-STZ-W202 FCC ID: 2AM3K-STZ-W202

ID Label/Location Info

Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2AM3K-STZ-W202

Internal Photos

FCC ID: 2AM3K-STZ-W202 Internal Photos of the EUT FCC ID: 2AM3K-STZ-W202 FCC ID: 2AM3K-STZ-W202 ANT FCC ID: 2AM3K-STZ-W202

RF Exposure Info

RF Exposure evaluation FCC ID: 2AM3K-STZ-W202 1.1. Applicable Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF exposure requirement KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 1.2. Requirement According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 “ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 1.3. Manufacturing tolerance pi/4 DQPSK (EIRP) Channel Channel Low Channel Mid Channel High Target (dBm) 7.0 7.0 7.0 Tolerance ±(dB) 1.0 1.0 1.0 Page 2 of 2 2. E v a l u a t i o n R e s u l t Evaluation Results Band/Mode f (GHz) Antenna Distance (mm) RF output power (including tune-up tolerance) SAR Test Exclusion Threshold SAR Test Exclusion dBm mW pi/4 DQPSK 0.470 5 8.0 6.3096 0.8651 <3.0 Yes 3. C o n c l u s i o n The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v06 .....................End of Report.........................

Test Report

1. Antenna Description: Antenna type Internal antenna Model STZ-W202 Frequency range 470.2-607.8MHz Manufacturer HANGZHOU NAG ELECTRONICS LTD ANT Peak Gain 1.12 dBi 2. Antenna Photo: Length: 28.03mm Diameter: 7.39mm

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART CTEST REPORT FCC PART 15.236 Report Reference No. ..................... : FCC ID. .............................................: CTA24090401001 2AM3K-STZ-W202 Compiled by ( position+printedname+signature) ... : File administrators Jinghua Xiao Supervised by (position+printedname+signature) .... : Project Engineer Xudong Zhang Approved by (position+printedname+signature) .... : RF Manager Eric Wang Date of issue ..................................... : Sep. 09, 2024 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : OKURA USA INC. Address ............................................ : 1195 NW. 97 AVENUE. MIAMI Florida United States 33172 Test specification ...........................: Standard ........................................... : FCC Part 15.236 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .....................: WIRELESS MICROPHONE Trade Mark ....................................... : Manufacturer .................................... : HANGZHOU NAG ELECTRONICS LTD Model/Type reference....................... : STZ-W202 Listed Models ................................... : N/A Modulation Type ............................... : pi/4 DQPSK Operation Frequency ........................ : 470.2-607.8MHz Rating ............................................... : DC 3.0V From Battery Result................................................ : PASS Report No.: CTA24090401001 Page 2 of 28 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : WIRELESS MICROPHONE Model /Type : STZ-W202 Series Model : N/A Applicant : OKURA USA INC. Address : 1195 NW. 97 AVENUE. MIAMI Florida United States 33172 Manufacturer : HANGZHOU NAG ELECTRONICS LTD Address : ROOM 803, HEBIN BUILDING, NO.333 NORTH JIANGUO ROAD, HANGZHOU,CHINA Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory Report No.: CTA24090401001 Page 3 of 28 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT operation mode 6 2.6 Block Diagram of Test Setup 6 2.7 Related Submittal(s) / Grant (s) 6 2.8 Modifications 6 3 T E S T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 7 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 8 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 10 4.1 AC Power Conducted Emission 10 4.2 Maximum Output Power 11 4.3 Occupied Bandwidth 13 4.4 Necessary Bandwidth 15 4.5 Transmitter spurious emissions 18 4.6 Frequency Stability 20 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 22 6 P H O T O S O F T H E E U T ........................................................... 23 Report No.: CTA24090401001 Page 4 of 28 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.236: Operation of wireless Wireless microphone system(bodypack transmitter)s in the bands 54-72 MHz, 76-88 MHz, 174-216 MHz, 470-608 MHz and 614-698 MHz. ANSI C63.10-2013:AmericanNationalStandardforTestingUnlicensedWirelessDevices Report No.: CTA24090401001 Page 5 of 28 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Sep. 02, 2024 Testing commenced on : Sep. 02, 2024 Testing concluded on : Sep. 09, 2024 2.2 Product Description Product Name: WIRELESS MICROPHONE Model/Type reference: STZ-W202 Power supply: DC 3.0V From Battery Hardware version: V1.0 Software version: V1.0 Testing sample ID: CTA240904010-1# (Engineer sample), CTA240904010-2# (…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AM3K-STZ-W202 Test Setup Photos of the EUT

Contact Information

Applicant

GONZALO J. PALENZUELA Manager
[email protected]305-592-2616Fax: 305-592-0030

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]+86 755 2322 5875

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C470.2 MHz - 607.8 MHz6.00 mW0.0009490000 %
Confidentiality
Long Term
Grant Notes
Output Power listed is EIRP.

Other Applications from OKURA USA INC.

amplifier - FCC ID 2AM3K-SPA-3000BT - OKURA USA INC.
2AM3K-SPA-3000BT

amplifier

Dec 18, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter