Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Fujian Newland Payment Technology Co.,Ltd. ADD: No. B602, Building #1, Haixia Jingmao Plaza,Fuzhou Bonded Area 350015, Fuzhou,Fujian, China TEL: +86-0591-83979587 FAX: +86-0591-83977666 Email: [email protected] Date: 202 4-04-15 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: We, Fujian Newland Payment Technology Co.,Ltd., hereby authorize Bay Area Compliance Laboratories Corp.(Dongguan) to act as a laboratory for testing and test report generation for the following project(s): (Product description: DH10, FCC ID:2AM6U-DH10W) The ESP8089 module in the product, which support 2.4G WIFI(b/g/n20/n40) 2412-2462MHz, but for this device 2.4G WIFI(802.11n40)2422-2452MHz proprietary technology was disabled by software,the end user has no capability to activate it. Sincerely, Signature: Printed Name: Yonghong Zhuang Title:Certification manager
Fujian Newland Payment Technology Co.,Ltd. ADD: No. B602, Building #1, Haixia Jingmao Plaza,Fuzhou Bonded Area 350015, Fuzhou,Fujian, China TEL: +86-0591-83979587 FAX: +86-0591-83977666 Email: [email protected] CFR 47 Β§2.911(d)(5)(i)(ii) Attestation Letter Attestation Letter Date: 2024-04-12 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 Β§2.911(d)(5)(i)(ii) Filing FCC ID:2AM6U-DH10W Fujian Newland Payment Technology Co.,Ltd.(βthe applicantβ) certifies that the equipment for which authorization is sought is not βcoveredβ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Fujian Newland Payment Technology Co.,Ltd.(βthe applicantβ) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing βcoveredβ equipment. Signature Printed Name: Yonghong Zhuang Title:Certification manager
U.S. AGENT LETTER OF ATTESTATION Date: 2024-04-12 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 Β§2.911(d)(7) Filing FCC ID:2AM6U-DH10W Fujian Newland Payment Technology Co.,Ltd. (βthe Applicantβ) certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Fujian Newland Payment Technology Co.,Ltd. (βthe Applicantβ) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Fujian Newland Payment Technology Co.,Ltd. Address: No. B602, Building #1, Haixia Jingmao Plaza,Fuzhou Bonded Area 350015, Fuzhou,Fujian, China FRN: 0026711499 Tel: +86-0591-83979587 Email: [email protected] Signed by (printed name): Yonghong Zhuang Signature:
QA-FR-170-B Fujian Newland Payment Technology Co.,Ltd. ADD: No. B602, Building #1, Haixia Jingmao Plaza,Fuzhou Bonded Area 350015, Fuzhou,Fujian, China TEL: +86-0591-83979587 FAX: +86-0591-83977666 Email: [email protected] FCC Authorization Date: 2024-04-12 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , Fujian Newland Payment Technology Co.,Ltd., Hereby authorizes Bay Area Compliance Laboratories Corp.( Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp.( Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Clientβs signature Printed Name: Yonghong Zhuang Title:Certification manager
QA-FR-172-A Fujian Newland Payment Technology Co.,Ltd. ADD: No. B602, Building #1, Haixia Jingmao Plaza,Fuzhou Bonded Area 350015, Fuzhou,Fujian, China TEL: +86-0591-83979587 FAX: +86-0591-83977666 Email: [email protected] FCC Confidential Authorization Date: 2024-04-12 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AM6U-DH10W In accordance with Sections 0.457 and 0.459 of the Commissionβs Rules, Fujian Newland Payment Technology Co.,Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: β’ Block Diagram β’ Schematics β’ Operation Description As well as short-term (secrecy cycle: 180 days) confidential treatment of information accompanying this application as outlined below: β’ Internal Photos β’ Userβs Manual β’ External Photos β’ Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature Printed Name: Yonghong Zhuang Title:Certification manager
Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN240229-09997E-RF-00A Report Template Version: FCC-Wi-Fi-V1.2 Page 62 of 62 APPENDIX C - RF EXPOSURE EVALUATION Applicable Standard According to subpart Β§1.1310,15.247(i) systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commissionβs guidelines. Limits for Maximum Permissible Exposure (MPE) (Β§1.1310, Β§2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3β1.34 614 1.63 *(100) 30 1.34β30 824/f 2.19/f *(180/fΒ²) 30 30β300 27.5 0.073 0.2 30 300β1500 / / f/1500 30 1500β100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to Β§1.1310 and Β§2.1091 RF exposure is calculated. Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4ο°RΒ² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: Operation Mode Frequency (MHz) Antenna Gain Conducted output power including Tune- up Tolerance Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric)(dBm)(mW) WiFi 2412-2462 1.54 1.43 1979.43 20.00 0.02 1.0 Note: The Conducted output power including Tune-up Tolerance provided by manufacturer. Result: Compliant. The devices meet FCC MPE at 20 cm distance ***** END OF REPORT *****
versions οΌ V1.0 Test reportTest report Shenzhen Zhongtianxun Communication Technology Co. Ltd radio-frequency Xie enyuan 187186853 structure Hu xiaoliang 181 2097 1171 audit operation Zhang wumin 159 1403 8427 Address No. 34 Shilong Avenue, Shiyan Street, Bao'an District, Shen zhen project information project name DH10 β WIFI Model POS Antenna type PCB Solution Company Antenna type PCB Solution Company Antenna system Date 2023-9-7 notes οΌ notes οΌ Add: No. 34 Shilong Avenue, Shiyan Street, Bao'an District, She nzhen TEL:0755 - 27588360 /27572127 FAX:0755 - 27588320 TEL:0755 27588360 /27572127 FAX:0755 27588320 Website:www.chinaztx.com DirectoryDirectory β R&D equipmentβ Explanation of nounsβ Test dataβ R&D equipmentβ Explanation of nounsβ Test dataβ Matching circuitβ Assembly instructionsβ Summaryβ Matching circuitβ Assembly instructionsβ Summary Mobile terminal antenna manufacturing and technical service provider R&D equipmentR&D equipment The company has one set of Satimo SG24 OTA testing system, the most advanced in the communication industry in France 2the communication industry in France , 2 sets of ETS OTA standar d testing system οΌ Bluetest reverberation darkroom 1 set οΌ1 set of MicroPross NFC testing system οΌ Can provide customers with accurateCan provide customers with accurate testing reports quickly and stably οΌFully compliant with CITA standards οΌSupport active passive testing of various standards such asstandards such as GSM/CDMA/WCDMA/TD/LTE/WIFI /BT/GPS/MIMO. The MicroPross NFC system can meet the testing requirements of varioustesting requirements of various operators οΌ Perform rapid performance testing on NFC devices and output formal certification test reports. Mobile terminal antenna manufacturing and technical service provider dBi Decibel relative isotropic antenna Explanation of nounsExplanation of nouns dBi Decibel relative isotropic antenna Tx Transmit frequency Rx Receive frequency TRP Total Radiated Power TIS Total Isotropic Sensitivity VSWR Vl Sdi W Ri VSWR V o l tage S tan di ng W ave R at i o GSM Global Service for Mobile communication DCS Digital Communication System DCS Digital Communication System PCS Personal Communication System PHS Personal Handl y β p hone S y stem y p y SAR Specific Absorption Rate PCB Printed Circuit Board CDMA Code Division Multi p le Access p WCDMA Wideband Code Division Multiple AccessLTE Long Term Evolution Mobile terminal antenna manufacturing and technical service provider Standing wave diagramStanding wave diagram Passive efficiency dataPassive efficiency data chNo FreqοΌMHzοΌ Gain(dBiοΌ Efficiency_Pcent 1 2400 1.353449427 63.79016083 2 2410 1 541192938 66 57009098 2 2410 1 . 541192938 66 . 57009098 3 2420 1.524375327 69.38341969 4 2430 1.287414794 69.0971675 5 2440 0.972231814 65.96208778 6 2450 1.075681489 67.67064162 7 2460 0.978523865 67.51884172 8 2470 0.961508976 68.17714506 9 2480 0.874914565 66.13047771 10 2490 0.738060728 64.82948643 11 2500 0.822665957 65.15350075 Radiation patternRadiation pattern 2450MHZ 2400MHZ 2500MHZ Matching instructionsMatching instructions Matching structure MhiM atc hi ng instructions Wifi E1 NC E2 0Ξ© E3 NC Mobile terminal antenna manufacturing and technical service provider ThanksοΌ Add: No. 34 Shilong Avenue, Shiyan Street, Bao'an District, She nzhen TEL:0755 - 27588360 /27572127 FAX:0755 - 27588320 TEL:0755 27588360 /27572127 FAX:0755 27588320 Website:www.chinaztx.com
TEST REPORT Applicant: Fujian Newland Payment Technology Co.,Ltd. Address: No. B602, Building #1, Haixia Jingmao Plaza, Fuzhou Bonded Area 350015, Fujian, China Product Name: DH10 FCC ID: 2AM6U-DH10W Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Report Number: XMDN240229-09997E-RF-00A Report Date: 2024/4/13 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked β² is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with β .This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN240229-09997E-RF-00A Report Template Version: FCC-Wi-Fi-V1.2 Page 2 of 62 CONTENTS DOCUMENT REVISION HISTORY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 4 1. GENERAL INFORMATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.2 ACCESSORY INFORMATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.3 ANTENNA INFORMATION DETAILβ² κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.4 EQUIPMENT MODIFICATIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 2. SUMMARY OF TEST RESULTS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 3. DESCRIPTION OF TEST CONFIGURATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.1 OPERATION FREQUENCY DETAIL κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.2 EUT OPERATION CONDITION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.3 SUPPORT EQUIPMENT LIST AND DETAILS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.4 SUPPORT CABLE LIST AND DETAILS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.5 BLOCK DIAGRAM OF TEST SETUP κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 3.6 TEST FACILITY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 3.7 MEASUREMENT UNCERTAINTY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 4. REQUIREMENTS AND TEST PROCEDURES κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 4.1 AC LINE CONDUCTED EMISSIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 4.1.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 4.1.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 4.1.3 EMI Test Receiver Setup κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 4.1.4 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 4.1.5 Corrected Amplitude & Margin Calculation κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 4.1.6 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 4.2 RADIATION SPURIOUS EMISSIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.2.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.2.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 4.2.4 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 4.2.5 Corrected Result & Margin Calculation κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 4.2.6 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 4.3 MINIMUM 6 DB EMISSION BANDWIDTH κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.3.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.3.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.3.3 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.3.4 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.4 99% OCCUPIED BANDWIDTH κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 4.4.1 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 4.4.2 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκβ¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 64.00 mW |
POS Terminal
Equipment Class
PCB - PCS Licensed TransmitterPOS Terminal
Equipment Class
NII - Unlicensed National Information Infrastructure TXDS90
Equipment Class
DTS - Digital Transmission SystemUnattended Terminal
Equipment Class
DTS - Digital Transmission SystemUnattended Terminal
Equipment Class
NII - Unlicensed National Information Infrastructure TX