Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
-IC Caution: -Radio Standards Specification RSS-Gen, issue 5 -- English: -This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: -This device may not cause interference. -This device must accept any interference, including interference that may cause undesired operation of the device. -RF exposure statement: -The equipment complies with IC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. -- French: -Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS) d'Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes: -Cet appareil ne doit pas causer d'interférences. -Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un fonctionnement indésirable de l'appareil. -Déclaration d'exposition RF: -L'équipement est conforme à la limite d'exposition aux radiations de la IC établie pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. - FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC RF exposure statement: The equipment complies with FCC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Warning: Changes or modifications to this unit not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment
C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Republic Wireless, Inc. Address: 940 Main Campus Drive, Ste 300, Raleigh, NC, 27606 USA Product Name: Multi-unit Wireless Charger Model Number: RW1702 FCC Identifier: 2AMBHRW1702 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Michael DiVerde Date: 12/30/2020 Title: VP Product Management Signature of applicant:
C5266091_X10_Ed.1 1/1 Republic Wireless, Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 12/30/2020 Subject: Request for Confidentiality FCC ID: 2AMBHRW1702 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Michael DiVerde Date: 12/30/2020 Title: VP Product Management
1 - Page 1 of 3 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model RW1702) Photo 2 1 - Page 2 of 3 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 3 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 ----END OF REPORT----
30mm*20mm
1 - Page 1 of 6 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model RW1702) Photo 2 1 - Page 2 of 6 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 6 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 1 - Page 4 of 6 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 7 Photo 8 1 - Page 5 of 6 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 9 Photo 10 1 - Page 6 of 6 - Report No.: MTi20042810-3E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 11 Photo 12 ----END OF REPORT---- Coil antenna
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. EXPOSURE REPORT FCC ID: 2AMBHRW1702 Date of issue: Dec. 14, 2020 Report Number: MTi20042810-3E2 Sample Description: Multi-unit Wireless Charger Mo d e l( s ) : RW1702 Applicant: Republic Wireless, Inc. Address: 940 Main Campus Drive, Ste 300, Raleigh, NC, 27606 USA Date of Test: Nov. 25, 2020 - Dec. 08, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 12 - Report No.: MTi20042810-3E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Result Certification Applicant’s name: Republic Wireless, Inc. Address: 940 Main Campus Drive, Ste 300, Raleigh, NC, 27606 USA Manufacture's name: Shenzhen Aodehong Electronic Technology Co., Ltd Address: 5/F Elegant Industrial Park, No. 8, Liuhe Rd. , Henggang St., Longgang Dist., Shenzhen, R.P.C. Product name: Multi-unit Wireless Charger Trademark: Relay Model name: RW1702 Standard: FCC CFR 47 PART 1 , 1.1310 RF Exposure Procedures: KDB 680106 D01 RF Exposure Wireless Charging App v03 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Demi Mu Dec. 08, 2020 Reviewed by: Leo Su Dec. 14, 2020 Approved by: Tom Xue Dec. 14, 2020 - Page 3 of 12 - Report No.: MTi20042810-3E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 1 General Information 1.1 Description of EUT Product name: Multi-unit Wireless Charger Brand name: Relay Model name: RW1702 Series model: N/A Deference in serial model: N/A Operation frequency: 115–205 kHz Maximum output power: 15W Operational mode: Wireless charging Modulation type: ASK Antenna type: Coil Antenna Power source: DC 15V from adapter AC 120V/60Hz Battery: N/A Adapter information: N/A 1.2 Ancillary equipment list Equipment Model S/N Manufacturer Adapter BS-E915 / Shenzhen Times Innovation Technology Co., Ltd Load AP / / 1.3 Measurement uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) Radiated emission(150kHz~30MHz) ± 2.5 dB Radiated emission(30MHz~1GHz) ± 4.2 dB Radiated emission (above 1GHz) ± 4.3 dB Temperature ±1 degree Humidity ± 5 % - Page 4 of 12 - Report No.: MTi20042810-3E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 2 Testing site Test Site Shenzhen Microtest Co., Ltd Test Site Location 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. FCC Registration No.: 448573 - Page 5 of 12 - Report No.: MTi20042810-3E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 3 List of test equipment Equipment No. Equipment Name Manufacturer Model Serial No. Calibration date Due date MTI-E115 Electric and Magnetic Field Probe - Analyzer Narda Safety Test Solutions GmbH EHP- 200A / 2020/11/12 2021/11/11 - Page 6 of 12 - Report No.: MTi20042810-3E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 4 Test Results 4.4 Maximum permissible exposure 4.4.1 Limit Frequency range(MHz) Electric field strength(V/m) Magnetic field strength(A/m) Power density(mW/cm2) Averaging time(minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 6 300-1500 f/300 6 1500-100000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1500 f/1500 30 1500-100000 1 30 f = frequency in MHz * = Plane-wave equivalent power density 4.4.2 Test Procedures E and H-field measurements should be made with the center of the probe at a distance of 15 cm surrounding the device and 20 cm above the top surface of the primary/client pair. These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%. Record the test results. KDB 680106 D01 RF Exposure Wireless Charging App v03: (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. - Page 7 of 12 - Report …
Text truncated - open the document above for the full version.
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Report FCC ID: 2AMBHRW1702 Date of issue: Dec. 14, 2020 Report number: MTi20042810-3E1 Sample description: Multi-unit Wireless Charger Mo d e l( s ) : RW1702 Applicant: Republic Wireless, Inc. Address: 940 Main Campus Drive, Ste 300, Raleigh, NC, 27606 USA Date of test: Nov. 25, 2020 – Dec. 08, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 25 - Report No.: MTi20042810-3E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Table of Contents 1 GENERAL INFORMATION ................................................................................................................................... 4 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ................................................................................................................... 4 1.2 TEST MODE .............................................................................................................................................................. 4 1.3 EUT TEST SETUP........................................................................................................................................................ 4 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 4 2 SUMMARY OF TEST RESULT ............................................................................................................................... 5 2.1 OPERATION CHANNEL LIST ........................................................................................................................................... 5 2.2 TEST CHANNEL .......................................................................................................................................................... 5 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 6 3.1 TEST LABORATORY ..................................................................................................................................................... 6 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 6 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 6 4 LIST OF TEST EQUIPMENT .................................................................................................................................. 7 5 TEST RESULTS ..................................................................................................................................................... 8 5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 8 5.1.1 Standard requirement ................................................................................................................................. 8 5.1.2 EUT Antenna ............................................................................................................................................... 8 5.2 CONDUCTED EMISSION ............................................................................................................................................... 9 5.2.1 Limits ........................................................................................................................................................... 9 5.2.2 Test Procedures ........................................................................................................................................... 9 5.2.3 Test Setup .................................................................................................................................................... 9 5.2.4 Test Result ................................................................................................................................................... 9 5.3 RADIATED EMISSION ................................................................................................................................................. 14 5.3.1 Limits ......................................................................................................................................................... 14 5.3.2 Test Procedures ......................................................................................................................................... 15 5.3.3 Test Setup .................................................................................................................................................. 16 5.3.4 Test Result ................................................................................................................................................. 16 5.4 OCCUPIED BANDWIDTH............................................................................................................................................. 20 5.4.1 Test method ............................................................................................................................................... 20 5.4.2 Test result .......................................................................................................................…
Text truncated - open the document above for the full version.
Model: RW1702 Radiated emission Conducted emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |
WIRED HEADSET
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterRelay
Equipment Class
UWB - Ultra Wideband Transmitter
Relay+
Equipment Class
JAB - Part 15 Class B Digital Device