Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 22, 2020
Application Purpose
Original Equipment
Date of Application
Nov 22, 2020
Equipment Note
SMART WATER VALVE
Frequency Range
2412.00000000 - 2462.00000000
Company
HANGZHOU FRANKEVER ELECTRONIC CO.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 4 Use waterproof Aviation socket, safe and secure 5 6 word Press the button for 5 seconds,move your finger and wait a few seconds till the LED light turn to blue flicker. Then ”CONFIRM ” to next step. 8 9 Ensure the water valve blue light in quickly flash, then press”More device reset methods” 12 14 5 15 16 Countdown Function 17 APP Cloud Timing Function (Schedule function) Set Start or End Time Set Valve Position according to your needs 18 Model No.: FK-V02 Support Ambient Temperature:-30°C~60°C Input Voltage: DC5V Max pressure: 1.0Mpa Materials: SS304 & Engineering Plastics Valve Size: DN15,DN20,DN25,DN32 Screw Thread: NPT BSP Frequency of Timing: Unlimited times per day, the interval between the maximum period is once a week. App manual control, Field manual operation, APP cloud timing, Countdown Controller Operation: 3 24 25 26 Smart lifeSmart life 2 Power Failure Protection Function: If the power is cut off suddenly, the water valve will automatically close within 2 seconds 19 Automation Funcation How to use automation funcation with smart water leak sensor: (Kindly notice: make sure your water sensor in same protocol as water valve. Zigbee water valve request Tuya zigbee water sensor, and our wifi water valve request Tuya wifi water sensor! ) 21 23 Choose “Others(Zig- bee)” from “Other” area Enter the App and press “+” at upper right corner to add gateway 10 for Zigbee version water valve (Ensure you have zigbee gateway together, which requested to use together with our water valve) 20 Step 1: Make sure you already paired the water sensor and water valve in same app successfully. Step 2: Press “ smart” then in “Automation” page. Then press “+” at upper right corner to create a task Step 3:Set a condition on water leak sensor Step 4: Set up task for water valve, then you can see the task details, and water valve will do action automatically. 22 Press” Add Manually” –“Gateway and others” –“Connector(- Wi-Fi) ” to add a new item. 7 For WiFi type water valve After gateway paring done, enter into the main page of Gateway, continue to add the water valve from “Add Subdevice” Paring with gateway when the red led light in quickly flash 11 4 Press “Others” and start to pair, until you see the water valve on your reparing page, then its done. 13 6 FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the follow ing two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, inc luding interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residentia l installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televis ion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technic ian for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be insta lled and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.

Cover Letter(s)

Rev11/20/07 (HANGZHOUFRANKEVERELECTRONICCO.,LTD.) FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID: 2AMMG-FKV02 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName BlockDiagram, Schematics, OperationalDescription BlockDiagram Schematics OperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. Sincerely, (YonghuaXia)

Cover Letter(s)

HANGZHOUFRANKEVERELECTRONICCO.,LTD. ModelDifference 2020-11-11 EUTNAME:SMARTWATERVALVE FCCID:2AMMG-FKV02 MODEL:FK-V02 FK-V02-WIFI,FK-V02-ZIG,FK-V03-WIFI,FK-V03-ZIG,FK-V04,FK-V05,FK-V06, FK-V07,FK-V08,FK-V09,FK-WM01,FK-WM-02 AllthemodelarethesamecircuitandRFmodule,exceptmodelnames. Regards Sincerely Client’ssignature Client’sname/title:YonghuaXia(Manager) Contactinformation/address:2F,HuaYinIndustrialBuilding,No.166WenYuan NorthRoad,XiashaHEDAHangzhou310018,China

Cover Letter(s)

(HANGZHOUFRANKEVERELECTRONICCO.,LTD.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Date:2020/11/11 SUBJECT:FCCApplicationforFCCID:2AMMG-FKV02 ToWhomItMayConcern: We,theundersigned,herebyauthorizeAlanMeiatShenzhenBCTCTestingCo.,Ltd.on ourbehalf,toapplytotheFederalCommunicationsCommissiononourequipment.Any andallactscarriedoutbyAlanMeiofShenzhenBCTCTestingCo.,Ltd.onourbehalf shallhavethesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, (YonghuaXia)

External Photos

External Photos

Internal Photos

Internal Photos Antenna

RF Exposure Info

FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2AMMG-FKV02 Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna, R=0.2m TEST RESULTS Tune up Produce power Maximu m peak output power (dBm) Output power to antenn a (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW / cm2 ) Result 802.11b (2.4G Hz WIFI) 9±1 10 10 1.995 (3dBi) 0.00397 1 Pass Zigbee 5±1 6 3.98 1.995 (3dBi) 0.00158 1 Pass

Test Report

No.:BCTC/RF-EMC-005Page 1 of 44 Edition:A.1 TESTREPORT ReportNo.:BCTC2009002061-1E Applicant:HANGZHOUFRANKEVERELECTRONICCO.,LTD. ProductName:SMARTWATERVALVE Model/TypeRef.:FK-V02 TestedDate:Sep.25,2020toOct.19,2020 IssuedDate:Oct.19,2020 ShenzhenBCTCTestingCo.,Ltd. ReportNo.:BCTC2009002061-1E No.:BCTC/RF-EMC-005Page 2 of 44 Edition:A.1 FCCID:2AMMG-FKV02 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp.Thisresult(s)showninthisreport referonlytothesample(s)tested.WithoutwrittenapprovalofShenzhenBCTCTestingCo.,Ltd,thisreport can’tbereproducedexceptinfull.Thetestedsample(s)andthesampleinformationareprovidedbytheclient. ProductName: SMARTWATERVALVE Trademark:FRANKEVER Model/TypeRef.: FK-V02 FK-V02-WIFI,FK-V02-ZIG,FK-V03-WIFI,FK-V03-ZIG, FK-V04,FK-V05,FK-V06,FK-V07,FK-V08,FK-V09, FK-WM01,FK-WM-02 PreparedFor: HANGZHOUFRANKEVERELECTRONICCO.,LTD. Address: 2F,HuaYinIndustrialBuilding,No.166WenYuanNorth Road,XiashaHEDAHangzhou310018,China Manufacturer: HANGZHOUFRANKEVERELECTRONICCO.,LTD. Address: 2F,HuaYinIndustrialBuilding,No.166WenYuanNorth Road,XiashaHEDAHangzhou310018,China PreparedBy: ShenzhenBCTCTestingCo.,Ltd. Address: 1-2F,EastofBBuilding,PengzhouIndustrial,Fuyuan1st Road,QiaotouCommunity,FuyongStreet,Bao’anDistrict, Shenzhen,China SampleReceivedDate:Sep.25,2020 SampletestedDate:Sep.25,2020toOct.19,2020 IssueDate:Oct.19,2020 ReportNo.:BCTC2009002061-1E TestStandards FCCPart15.247 ANSIC63.10-2013 TestResultsPASS Testedby:Approvedby: KelseyTan/ProjectHandlerZeroZhou/Reviewer ReportNo.:BCTC2009002061-1E No.:BCTC/RF-EMC-005Page 3 of 44 Edition:A.1 TABLEOFCONTENT TestReportDeclarationPage 1.VERSION ............................................................................................................................... 5 2.TESTSUMMARY ................................................................................................................. 6 3.MEASUREMENTUNCERTAINTY .................................................................................... 7 4.PRODUCTINFORMATIONANDTESTSETUP ............................................................ 8 4.1ProductInformation ......................................................................................................... 8 4.2TestSetupConfiguration ............................................................................................... 8 4.3SupportEquipment ......................................................................................................... 9 4.4ChannelList ..................................................................................................................... 9 4.5TestMode ......................................................................................................................... 9 4.6Tableofparametersoftextsoftwaresetting ............................................................. 10 5.TESTFACILITYANDTESTINSTRUMENTUSED ..................................................... 11 5.1TestFacility .................................................................................................................... 11 5.2TestInstrumentUsed ................................................................................................... 12 6.CONDUCTEDEMISSIONS .............................................................................................. 14 6.1BlockDiagramOfTestSetup ...................................................................................... 14 6.2Limit ................................................................................................................................. 14 6.3Testprocedure ............................................................................................................... 14 6.4EUToperatingConditions ............................................................................................ 14 6.5TestResult ..................................................................................................................... 15 7.RADIATEDEMISSIONS ................................................................................................... 17 7.1BlockDiagramOfTestSetup ...................................................................................... 17 7.2Limit ................................................................................................................................. 18 7.3Testprocedure ............................................................................................................... 19 7.4EUToperatingConditions ............................................................................................ 20 7.5TestResult ..................................................................................................................... 21 8.RADIATEDBANDEMISSIONMEASUREMENTANDRESTRICTEDBANDSOF OPERATION ........................................................................................................................... 25 8.1BlockDiagramOfTestSetup ...................................................................................... 25 8.2Limit ................................................................................................................................. 25 8.3Testprocedure ............................................................................................................... 26 8.4EUToperatingConditions ............................................................................................ 26 8.5TestResult ..................................................................................................................... 27 9.POWERSPECTRALDENSITYTEST ........................................................................... 28 9.1BlockDiagramOfTestSetup ...................................................................................... 28 9.2Limit ................................................................................................................................. 28 9.3Testprocedure ........................…

Text truncated - open the document above for the full version.

Test Report

No.:BCTC/RF-EMC-005Page: 1 of 67 Edition:A.1 TESTREPORT ReportNo.:BCTC2009002061-2E Applicant:HANGZHOUFRANKEVERELECTRONICCO.,LTD. ProductName:SMARTWATERVALVE Model/TypeRef.:FK-V02 TestedDate:Sep.25,2020toOct.19,2020 IssuedDate:Oct.19,2020 ShenzhenBCTCTestingCo.,Ltd. ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 2 of 67 Edition:A.1 FCCID:2AMMG-FKV02 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp.Thisresult(s)showninthisreport referonlytothesample(s)tested.WithoutwrittenapprovalofShenzhenBCTCTestingCo.,Ltd,thisreport can’tbereproducedexceptinfull.Thetestedsample(s)andthesampleinformationareprovidedbytheclient. ProductName: SMARTWATERVALVE Trademark: FRANKEVER Model/TypeRef.: FK-V02 FK-V02-WIFI,FK-V02-ZIG,FK-V03-WIFI,FK-V03-ZIG, FK-V04,FK-V05,FK-V06,FK-V07,FK-V08,FK-V09, FK-WM01,FK-WM-02 PreparedFor: HANGZHOUFRANKEVERELECTRONICCO.,LTD. Address: 2F,HuaYinIndustrialBuilding,No.166WenYuanNorthRoad, XiashaHEDAHangzhou310018,China Manufacturer: HANGZHOUFRANKEVERELECTRONICCO.,LTD. Address: 2F,HuaYinIndustrialBuilding,No.166WenYuanNorthRoad, XiashaHEDAHangzhou310018,China PreparedBy: ShenzhenBCTCTestingCo.,Ltd. Address: 1-2F,EastofBBuilding,PengzhouIndustrial,Fuyuan1st Road,QiaotouCommunity,FuyongStreet,Bao’anDistrict, Shenzhen,China SampleReceivedDate: Sep.25,2020 SampletestedDate: Sep.25,2020toOct.19,2020 IssueDate: Oct.19,2020 ReportNo.: BCTC2009002061-2E TestStandards FCCPart15.247 ANSIC63.10-2013 TestResultsPASS Remark:ThisisWIFI-2.4GHzbandradiotestreport. Testedby:Approvedby: KelseyTan/ProjectHandlerZeroZhou/Reviewer ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 3 of 67 Edition:A.1 TABLEOFCONTENT TestReportDeclarationPage 1.VERSION ............................................................................................................................... 5 2.TESTSUMMARY ................................................................................................................. 6 3.MEASUREMENTUNCERTAINTY .................................................................................... 7 4.PRODUCTINFORMATIONANDTESTSETUP ............................................................ 8 4.1ProductInformation ......................................................................................................... 8 4.2TestSetupConfiguration ............................................................................................... 8 4.3SupportEquipment ......................................................................................................... 9 4.4ChannelList ..................................................................................................................... 9 4.5TestMode ....................................................................................................................... 10 4.6tableofparametersoftextsoftwaresetting .............................................................. 10 5.TESTFACILITYANDTESTINSTRUMENTUSED ..................................................... 11 5.1TestFacility .................................................................................................................... 11 5.2TestInstrumentUsed ................................................................................................... 11 6.CONDUCTEDEMISSIONS .............................................................................................. 13 6.1BlockDiagramOfTestSetup ...................................................................................... 13 6.2Limit ................................................................................................................................. 13 6.3Testprocedure ............................................................................................................... 13 6.4EUToperatingConditions ............................................................................................ 13 6.5TestResult ..................................................................................................................... 14 7.RADIATEDEMISSIONS ................................................................................................... 16 7.1BlockDiagramOfTestSetup ...................................................................................... 16 7.2Limit ................................................................................................................................. 17 7.3Testprocedure ............................................................................................................... 18 7.4EUToperatingConditions ............................................................................................ 19 7.5TestResult ..................................................................................................................... 20 8.RADIATEDBANDEMISSIONMEASUREMENTANDRESTRICTEDBANDSOF OPERATION ........................................................................................................................... 27 8.1BlockDiagramOfTestSetup ...................................................................................... 27 8.2Limit ................................................................................................................................. 27 8.3Testprocedure ............................................................................................................... 28 8.4EUToperatingConditions ............................................................................................ 28 8.5TestResult ..................................................................................................................... 29 9.POWERSPECTRALDENSITYTEST ........................................................................... 31 9.1BlockDiagramOfTestSetup ...................................................................................... 31 9.2Limit .........................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 50 of 67 Edition:A.1 11.5TestResult Temperature: 26°C Relative Humidity: 54% Pressure: 101kPa TestVoltage: DC5V Frequency MaximumConducted OutputPower(PK) LIMIT (MHz)(dBm)dBm 802.11b 2412 7.3830 2437 8.0330 2462 8.0630 802.11g 2412 6.5530 2437 6.6630 2462 6.8430 802.11n20 2412 5.1930 2437 5.2630 2462 5.6930 802.11n40 2422 4.0130 2437 4.3930 2452 4.0530 ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 51 of 67 Edition:A.1 12.100KHZBANDWIDTHOFFREQUENCYBANDEDGE 12.1BlockDiagramOfTestSetup 12.2Limit Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrum intentionalradiatorisoperating,theradiofrequencypowerthatisproducedbytheintentional radiatorshallbeatleast20dBbelowthatinthe100kHzbandwidthwithinthebandthat containsthehighestlevelofthedesiredpower,basedoneitheranRFconductedora radiatedmeasurement. 12.3Testprocedure Usingthefollowingspectrumanalyzersetting: a)SettheRBW=100KHz. b)SettheVBW=300KHz. c)Sweeptime=autocouple. d)Detectorfunction=peak. e)Tracemode=maxhold. f)Allowtracetofullystabilize.. 12.4EUToperatingConditions TheEUTtestedsystemwasconfiguredasthestatementsof4.6Unlessotherwiseaspecial operatingconditionisspecifiedinthefollowsduringthetesting. Note:PowerSpectralDensity(dBm)=Reading+CableLoss ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 52 of 67 Edition:A.1 12.5TestResult Temperature: 26°C Relative Humidity: 54% Pressure: 101kPa TestVoltage: DC5V 802.11b:BandEdge,LeftSide 802.11b:BandEdge,RightSide ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 53 of 67 Edition:A.1 802.11g:BandEdge,LeftSide 802.11g:BandEdge,RightSide ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 54 of 67 Edition:A.1 802.11n-HT20:BandEdge,LeftSide 802.11n-HT20:BandEdge,RightSide ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 55 of 67 Edition:A.1 802.11n-HT40:BandEdge,LeftSide 802.11n-HT40:BandEdge,RightSide ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 56 of 67 Edition:A.1 CONDUCTEDEMISSIONMEASUREMENT 802.11b LowChannel2412MHz MiddleChannel2437MHz HighChannel2462MHz ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 57 of 67 Edition:A.1 802.11g LowChannel2412MHz MiddleChannel2437MHz HighChannel2462MHz ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 58 of 67 Edition:A.1 802.11n20 LowChannel2412MHz MiddleChannel2437MHz HighChannel2462MHz ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 59 of 67 Edition:A.1 802.11n40 LowChannel2422MHz MiddleChannel2437MHz HighChannel2452MHz ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 60 of 67 Edition:A.1 13.DUTYCYCLEOFTESTSIGNAL 13.1Standardrequirement Pre-analysisCheck:Whileconductingaveragepowermeasurement,dutycycleofeach modeshallbecheckedtoensureitsdutycycleinordertocompensateforthelossdueto insufficientratioofdutycycle. Alldutycycleispre-scanned,andresultasobtainedbelowshowsonlythemost representativeoneswheredutycycleisconductedasthegiventransmissionwithgiven virtualoperationthatexpressesthepercentage. 13.2Formula DutyCycle=Ton/(Ton+Toff) 13.3Testprocedure 1.Setspan=Zero 2.RBW=8MHz 3.VBW=8MHz, 4.Detector=Peak 13.4TestResult DutyCycleDutyFator (dB) 802.11b10 802.11g10 802.11n(HT20)10 802.11n(HT40)10 ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 61 of 67 Edition:A.1 802.11b 802.11g ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 62 of 67 Edition:A.1 802.11n(HT20) 802.11n(HT40) ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 63 of 67 Edition:A.1 14.ANTENNAREQUIREMENT 14.1Limit 15.203requirement:Forintentionaldevice,accordingto15.203:anintentionalradiatorshall bedesignedtoensurethatnoantennaotherthanthatfurnishedbytheresponsibleparty shallbeusedwiththedevice. 14.2TestResult TheEUTantennaisPCBantenna,fulfilltherequirementofthissection. ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 64 of 67 Edition:A.1 15.EUTPHOTOGRAPHS EUTPhoto1 EUTPhoto2 ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 65 of 67 Edition:A.1 16.EUTTESTSETUPPHOTOGRAPHS Conductedemissions ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 66 of 67 Edition:A.1 RadiatedMeasurementPhotos ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 67 of 67 Edition:A.1 STATEMENT 1.Theequipmentlistsaretraceabletothenationalreferencestandards. 2.Thetestreportcannotbepartiallycopiedunlesspriorwrittenapprovalisissuedfromourlab. 3.Thetestreportisinvalidwithoutstampoflaboratory. 4.Thetestreportisinvalidwithoutsignatureofperson(s)testingandauthorizing. 5.ThetestprocessandtestresultisonlyrelatedtotheUnitUnderTest. 6.ThequalitysystemofourlaboratoryisinaccordancewithISO/IEC17025. 7.Ifthereisanyobjectiontoreport,theclientshouldinformissuinglaboratorywithin15days fromthedateofreceivingtestreport. Address: 1-2F,EastofBBuilding,PengzhouIndustrialPark,Fuyuan1stRoad,Qiaotou,FuyongStreet,Ba o'anDistrict,Shenzhen,Guangdong,China TEL:400-788-9558 P.C.:518103 FAX:0755-33229357 Website:http://www.bctc-lab.com E-Mail:[email protected] ※※※※※END※※※※※

Test Setup Photos

ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 65 of 67 Edition:A.1 16.EUTTESTSETUPPHOTOGRAPHS Conductedemissions ReportNo.:BCTC2009002061-2E No.:BCTC/RF-EMC-005Page: 66 of 67 Edition:A.1 RadiatedMeasurementPhotos

Contact Information

Applicant

Yonghua Xia
[email protected]0571-85829475Fax: 0571-85829470

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz6.40 mW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power. Device must be operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes.