Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Professional car surface inspection The MS3012 multi-angle spectrophotometer uses an industrial- grade MCU and supports 12 measurement angles, providing accurate and consistent color measurement for gold, pearlescent and other complex special-effect color products. The smooth operating system and superior optical measurement system allow the MS3012 multi-degree spectrophotometer to provide repeatable and reproducible scintillation, color scintillation, and particle size measurements. color changing paint Color flash Graininess flicker Multi-Angle Spectrophotometer 、Multi-angle measurement Using 7 light sources and 2 receivers, it can measure 12 angles at the same time 、Display is more intuitive The touch screen can display the measurement results of all angles, and view the comprehensive data more intuitively. 、Effect measurement discrimination function Quickly identify the scintillation, color scintillation and particle size of the sample, and implement quality inspection simply and effectively. 、256-element dual-array CMOS image sensor Higher optical resolution ensures the measurement speed, accuracy, stability and consistency of the instrument, mastering the core technology, and achieving complete compatibility with the same platform as international standards. 、 Full spectrum LED light source with blue light enhancement The blue light-enhanced full-spectrum LED light source ensures a sufficient spectral distribution in the visible light range, avoiding the spectral missing of LEDs in specific wavelength bands. 、Concave grating spectroscopic technology Using concave grating spectroscopic technology, it has higher resolution and makes color measurement more accurate. 、Professional grade whiteboard A lifetime promise that will never change. 、higher quality Adopt industrial-grade real-time processing MCU, support Bluetooth 5.0 transmission more stable and reliable. 、Novel and fashionable design based on ergonomics The shape of the instrument is designed for easy operation and can meet different holding habits. The smooth and fine surface is derived from the high-precision appearance processing technology. 、Color camera preview for clear observation of the measured area The built-in color camera for framing and positioning can accurately determine the measured part of the object, which improves the measurement efficiency and accuracy. 、Multiple color measurement spaces, multiple observation light sources Provides 6 color spaces and a variety of observation light sources, which can meet the special measurement needs under different measurement conditions. 、Easily analyze data The screen can intuitively display spectrum graph/data, sample color value, color difference value/graph, pass/fail result, color simulation, color bias, sample effect value Features Polychromatic spectrophotometers are widely used in plastics, electronics, paint and ink, textile and garment printing and dyeing, printed paper, automobile, medical, cosmetics and food industries. The instrument is equipped with high-end color management software, which can be connected to a computer to achieve more functional expansion. MS3012Product parameters Measuring geometry Color measurement role Standards compliant characteristic Lighting source Lighting source life Spectroscopic method detector wavelength range wavelength spacing Measuring range half width Measuring diameter color space Color difference formula Other indicators Observer's point of view Observation light source show measure time color repeatability color reproducibility Differ instruments Effect parameters Effect measurement effect repeatability effect reproducibility Trigger method measurement method Targeting size weight battery power display interface Storing data language calibration Calibration interval Standard accessories Optional accessories 12 measuring angles (7 light sources, 2 receivers) 45° receiver: 45as-15°, 45as15°, 45as25°, 45as45°, 45as75°, 45as110° 15° receiver: 15as-45°, 15as-15°, 15as15°, 15as- 30°,15as45°,15as80° ASTMD2244,E308,E1164,E2194,E2539,DIN5033,5036,6174,6175-1,6175-2;ISO7724,11664-4,SAEJ1545 Accurate and consistent color measurement for metallic, pearlescent, and other complex special-effect color products Blue light-enhanced full-spectrum LEDs 5 years 3 million measurements Concave grating 256-element dual-array CMOS image sensor 400nm-700nm 10nm 0~600% 10nm Φ12mm CIELAB,XYZ,Yxy,LCh,βxy,DINLab99 ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,DINΔE99,ΔEDIN6175 FlopIndex,Radiation intensity value 2°/10° D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) Spectrum graph/data, sample color value, color difference value/graph, pass/fail result, color simulation, sample effect value, effect difference value The measurement time of a single angle is about 1s, and the measurement of all the angles takes about 12s Spectral reflectance: standard deviation within 0.08%, chromaticity value: 0.02 ΔE*ab (after the instrument is warmed up and calibrated, the average value of 30 times) △E*<0.10, average on grey BCRA panels, △E*<0.25, the average value on the color BCRA plate 0.18 E*0.0 BCRA series II 12 pieces of color plate measurement average Flicker, Color Flicker, Granularity 6 degrees of flicker, color flicker data: 15as-45°, 15as-30°, 15as-15°, 15as15°, 15as45°, 15as80°, 15d diffuse particle size Short-term repeatability of flicker: 0.12% (standard deviation of 10 times), (after the instrument is warmed up and calibrated, the average value of 10 times of color plate measurement),Short-term repeatability of particle size: 0.09% (standard deviation of 10 times) (measurement of color plate 10 times the average) Scintillation reproducibility: 1.9% particle size reproducibility: 1.4% Pressure sensitive trigger, button trigger, software trigger Single measurement, average measurement (1~99 times), continuous measurement (1~99 times) Color camera preview Length x width x height =195X8…
Text truncated - open the document above for the full version.
Shenzhen ThreeNH Technology Co.,Ltd Agent Authorization Company: Shenzhen ThreeNH Technology Co.,Ltd Address: Floor 6, Building 5B, Skyworth Innovation Valley, Tangtou No.1 Road, Shiyan Street, Bao an District, Shenzhen, Guangdong, China Product Name: Multi-Angle Spectrophotometer Model Number(s): MS3012, MS3003, MS3004, MS3005, MS3006, MS3008, MS3012, MS3016, MS3003+, MS3004+, MS3005+, MS3006+, MS3008+, MS3012+, MS3016+ We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Date: Feb. 22, 2022Signature: Name: Ivy xu Title: manager Company: Shenzhen ThreeNH Technology Co.,Ltd
Shenzhen ThreeNH Technology Co.,Ltd Date: Feb. 22, 2022 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2AMRM-MS30NX To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Ivy xu Title: manager Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure
Shenzhen ThreeNH Technology Co.,Ltd Model Confirmation Letter We, Shenzhen ThreeNH Technology Co.,Ltd certify the product: Multi- Angle Spectrophotometer, Model No.: MS3012,TMS3003, MS3004, MS3005, MS3006, MS3008, MS3012, MS3016, MS3003+, MS3004+, MS3005+, MS3006+, MS3008+, MS3012+, MS3016+ Their electrical circuit design, layout, components used and internal wiring were identical for the above models, with difference being model name. Signiture: Grantee Contact: Ivy xu Company Name: Shenzhen ThreeNH Technology Co.,Ltd Date: 2022-2-22
Label place Label Size : 30*55mm Multi-Angle Spectrophotometer S/N:82000100 MODEL: MS3012 FCC ID: 2AMRM-MS30NX INPUT: 5V 2A BATTERY:Li-ion 3.7V 5000mAh This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
BATTERY BT ANT
Project No.: ZKT-211228L73242 Page 1 of 31 FCC TEST REPORT FCC ID:2AMRM-MS30NX Report Number. ................................ : ZKT-211228L73242 Date of Test .................................................: Dec. 14, 2021 -- Dec. 30, 2021 Date of issue .................................... : Dec. 30, 2021 Total number of pages ...................... 31 Test Result ..................................... : PASS Testing Laboratory. ........................... : Shenzhen ZKT Technology Co., Ltd. Address .......................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ............................ : Shenzhen ThreeNH Technology Co.,Ltd Address .......................................... : Floor 6, Building 5B, Skyworth Innovation Valley, Tangtou No.1 Road, Shiyan Street, Bao an District, Shenzhen, Guangdong, China Manufacturer's name ..................... : Shenzhen ThreeNH Technology Co.,Ltd Address .......................................... : Floor 6, Building 5B, Skyworth Innovation Valley, Tangtou No.1 Road, Shiyan Street, Bao an District, Shenzhen, Guangdong, China Test specification: Standard ........................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.249 ANSI C63.10:2013 Test procedure ................................. : / Non-standard test method ............. : N/A Test Report Form No. .................... : TRF-EL-111_V0 Test Report Form(s) Originator .... : ZKT Testing Master TRF .................................... : Dated: 2020-01-06 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................... : Multi-Angle Spectrophotometer Trademark ...................................... : 3nh Model/Type reference ...................... : MS3012, MS3003, MS3004, MS3005, MS3006, MS3008, MS3012, MS3016, MS3003+, MS3004+, MS3005+, MS3006+, MS3008+, MS3012+, MS3016+ Ratings ............................................. : DC 3.7V from battery / DC5.0V from adapter Project No.: ZKT-211228L73242 Page 2 of 31 Testing procedure and testing location: Testing Laboratory ................................... : Shenzhen ZKT Technology Co., Ltd. Address ...................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Alen He Tested by (name + signature) .....................: Joe Liu Reviewer (name + signature) .....................: Lake Xie Approved (name + signature) .....................: Project No.: ZKT-211228L73242 Page 3 of 31 Table of Contents Page 1.VERSION 5 2.1SUMMARY OF TEST RESULTS 6 2.1TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3. GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 9 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 9 3.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 9 3.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 11 4. EMC EMISSION TEST 12 4.1 CONDUCTED EMISSION MEASUREMENT 12 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 12 4.1.2 TEST PROCEDURE 12 4.1.3 DEVIATION FROM TEST STANDARD 12 4.1.4 TEST SETUP 13 4.1.5 EUT OPERATING CONDITIONS 13 4.1.6 TEST RESULTS 14 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 TEST PROCEDURE 17 4.2.3 DEVIATION FROM TEST STANDARD 17 4.2.4 TEST SETUP 17 4.2.5 EUT OPERATING CONDITIONS 18 5. BANDWIDTH OF FREQUENCY BAND EDGE 24 5.1 TEST REQUIREMENT: 24 5.2 TEST PROCEDURE 24 5.3 DEVIATION FROM TEST STANDARD 25 5.4 TEST SETUP 25 5.5 EUT OPERATING CONDITIONS 25 5.6 TEST RESULT 26 6. CHANNEL BANDWIDTH 27 6.1 APPLIED PROCEDURES / LIMIT 27 6.2 TEST PROCEDURE 27 6.3 DEVIATION FROM STANDARD 27 6.4 TEST SETUP 27 Project No.: ZKT-211228L73242 Page 4 of 31 Table of Contents Page 6.5 EUT OPERATION CONDITIONS 27 6.6 TEST RESULTS 28 7.ANTENNA REQUIREMENT30 8.TEST SETUP PHOTO31 9.EUT CONSTRUCTIONAL DETAILS31 Project No.: ZKT-211228L73242 Page 5 of 31 1.VERSION Report No. Version Description Approved ZKT-211228L73242 Rev.01 Initial issue of report Dec. 30, 2021 Project No.: ZKT-211228L73242 Page 6 of 31 2.1SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.249) , Subpart C Standard Section Test Item Judgment Remark FCC part 15.203 Antenna requirement PASS FCC part 15.207 AC Power Line Conducted Emi sion PASS FCC part 15.249 Fundamental &Radiated Spurious Emission Measurement PASS FCC part 15.215(c) 20dB Channel Bandwidth PASS FCC part 15.205 Band Edge PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Project No.: ZKT-211228L73242 Page 7 of 31 2.1TEST FACILITY Shenzhen ZKT Technology Co., Ltd. Add. : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China FCC Test Firm Registration Number: 692225 Designation Number: CN1299 IC Registered No.: 27033 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power conducted ±0.16dB 3 Spurious emissions conducted ±0.21dB 4 All emissions radiated(<1G) ±4.68dB 5 All emissions radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Project No.: ZKT-211228L73242 Page 8 of 31 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Product Name: Multi-Angle Spectrophotometer Model No.: MS3012 Model Different.: Name maybe differ Serial No.: MS3003, MS300…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Portable Spectrophotometer
Equipment Class
DTS - Digital Transmission System
Portable Spectrophotometer
Equipment Class
DTS - Digital Transmission System
ColorReader
Equipment Class
DTS - Digital Transmission System
Color Haze meter
Equipment Class
DTS - Digital Transmission System
GRATING SPECTROPHOTOMETER
Equipment Class
DTS - Digital Transmission System