FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ONANOFF LTD/
  3. 2AN2MONFPWC

2AN2MONFPWCOnanoff Wireless Charger

ONANOFF LTD
Onanoff Wireless Charger - FCC ID 2AN2MONFPWC - ONANOFF LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 26, 2023
Application Purpose
Original Equipment
Date of Application
Sep 26, 2023
Equipment Note
Onanoff Wireless Charger
Frequency Range
0.11000000 - 0.20500000
Company
ONANOFF LTD
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1s 3s Power on/o Power On Marche Ein Encendido Acceso Ligar Aan-knop Virta Päälle Ström På Tænd For Av Питание Вкл Zasilanie Włączone Güç açık Zapněte Bekapcsolás Ενεργοποίηση เปิดเครื่อง הלעפה  Power O Arrêt Aus Apagado Spento Desligar Uit-knop Virta Pois Ström Av Sluk For På Питание выкл Zasilanie Wyłączone Güç kapalı Vypněte Kikapcsolás Απενεργοποίηση ปิดเครื่อง הקספה ف اإ shifts to Auto-Reconnecting Mode after Power On Reconnect Previous Device AUTO AUTO Auto-Reconnecting Mode Mode de reconnexion automatique Automatischer Wiederverbindungsmodus Auto-Reconnecting-Modus Modo de reconexión automática Modo de reconexão automática Automatische herverbindingsmodus Auto-Reconnecting Mode Auto-återanslutningsläge Automatisk genforbindelsestilstand Automatisk tilkoblingsmodus Tryb automatycznego ponownego łączenia Режим автоматического повторного подключения ا ال إ دة و אוטומטי חיבור מצב Otomatik Yeniden Bağlanma Modu Režim automatického opětovného připojení Automatikus újracsatlakozási mód Λειτουργία αυτόματης επανασύνδεσης โหมดเชื่อมตอใหมอัตโนมัติ Pair with 2nd smart device Appariement avec un deuxième appareil intelligent Kopplung mit einem zweiten intelligenten Gerät Emparejar con el segundo dispositivo inteligente Accoppiarsi con un secondo dispositivo intelligente Emparelhar com um segundo dispositivo inteligente Koppelen met een tweede smart device Yhdistä toiseen älylaitteeseen Para ihop med en andra smart enhet Parring med en anden smart enhed Paret med den andre smarte enheten Połączenie z drugim inteligentnym urządzeniem İkinci akıllı bir aygıtla eşlik edin. Spárovat s druhým chytrým zařízením Párosítás egy második intelligens eszközzel Ζευγάρι με μια δεύτερη έξυπνη συσκευή спаривание со вторым интеллектуальным устройством ตรงกับอุปกรณ์สมาร์ทที่สอง ا ا از  اان שני חכם מכשיר עם זוג + 3 Multi-Point Pairing 1 2 Change Volume Mode Change Volume Mode Lautstärkemodus ändern Cambiar Modo de Volumen Modalità Modiœca Volume Alterar o modo de volume Wijzig volumemodus Vaihda äänenvoimakkuutta Ändring av volymläget Skift lydstyrketilstand Modus for volumkontroll Изменить режим громкости Mode Modiœcation du volume Zmień tryb głośności Ses Değiştirme Modu Změňte režim hlasitosti Hangerőváltó mód Αλλαγή λειτουργίας έντασης เปลี่ยนโหมดระดับเสียง تى ا­ و€ הקול עוצמת מצב את שנה SafeAudio® Mode (0-85dB) Default Mode (0-100dB) 2s + 2s Volume Up/Down Volume Up Augmenter le volume Lautstärke erhöhen Subir Volumen Volume Up Aumentar volume Volume verhogen Äänenvoimakkuus ylös Volym upp Lydstyrke op Høyere volum Усилить громкость Zwiększ głośność Ses yükselt Zesílení hlasitosti Hangerő fel Αύξηση έντασης เพิ่มระดับเสียง עוצמה הגבר تى ا­ ‚ر Volume Down Réduire le volume Lautstärke verringern Bajar Volumen Volume Down Diminuir volume Volume verlagen Äänenvoimakkuus alas Volym ner Lydstyrke ned Lavere volume Уменьшить громкость Zmniejsz głośność Ses azalt Zeslabení hlasitosti Hangerő le Μείωση έντασης ลดระดับเสียง עוצמה הנמך ت ا„…† 1x 1x Track Control Play/Pause Lecture/Pause Wiedergabe/Pause Reproducir/Pausar Avvio/Pausa Reproduzir/Pausar Afspelen/Pauzeren Toista/Keskeytä Spela/Pausa Afspil/pause Avspilling/pause Odtwarzanie/Pauza Oynat/Duraklat Přehrát / Pozastavit Lejátszás/szünet Αναπαραγωγή/Παύση เล่น/หยุดชั่วคราว השהה/הפעל Track Back Piste précédente Vorheriger Titel Pista Anterior Brano Precedente Faixa Anterior Vorige track Siirry taaksepäin Låt bakåt Forrige spor Forrige spor Перемотка трека назад Poprzedni utwór Geri Sar Předchozí skladba Egy zeneszámmal vissza Προηγούμενο κομμάτι เล่นย้อนกลับ אחורה העברה ر­‡ ا ˆ‰ Воспроизведение/Пауза / Š‹ف  / إ 1x 1s1s Track Forward Piste suivante Nächster Titel Pista Siguiente Brano Successivo Faixa Seguinte Volgende track Siirry eteenpäin Låt framåt Næste spor Neste spor Перемотка трека вперёд Następny utwór İleri Sar Následující skladba Egy zeneszámmal előre Επόμενο κομμάτι เล่นไปข้างหน้า קדימה העברה ر­‡ اŒŽ Answer/Reject Calls Incoming Call Appel entrant Eingehender Anruf Llamada Entrante Chiamata in Arrivo Chamada recebida Binnenkomende oproep Saapuva puhelu Inkommande samtal Indgående opkald Innkommende anrop Входящий звонок Answer Call Appel en cours Bei Anruf Llamada Activa Chiamata in Corso Em chamada In gesprek Puhelu kesken I samtal Opkald Samtale Текущий звонок Reject Call Rejeter l'appel Anruf ablehnen Rechazar llamada Riœuta la chiamata Rejeitar chamada Oproep weigeren Hylkää puhelu Avvisa samtal Afvis opkald Avvis anrop Отклонить звонок 1x Połączenie przychodzące W trakcie rozmowyOdrzuć połączenie Gelen çağrı TelefondaÇağrıyı reddet Příchozí hovor Volání (hovor)Odmítnutí hovoru Bejövő hívás Hívás alattHívás elutasítása Εισερχόμενη κλήση Σε κλήσηΑπόρριψη κλήσης สายเรียกเข้า กําลังใช้สายโทรอยู่ ปฏิเสธการรับสาย נכנסת שיחה ’‡‘ واردة בשיחה ‘‡’‡ ا“ שיחה דחה ‘‡’‡ ا„‚ر 1s Quick Flash Low Power Charging Recharge Laden Cargando Ricarica in Corso Recarga Opladen Lataa Laddar Genoplader Lader Перезарядка Low Power Batterie faible Batterie schwach Batería Baja Batteria Scarica Bateria Fraca Batterij-bijna-leeg Akun virta vähäinen Låg batterinivå Lavt strømniveau Lite batteri Низкий уровень зарядки Fully charged Entièrement chargé Vollständig laden Carga Completa Ricarica Completata Bateria Totalmente Carregada Volledig opladen Akku täysin ladattu Full laddad Fuld opladning Fullt ladet Полная зарядка Niski poziom bateriiŁadowanieW pełni naładowany Düşük güçŞarj oluyorTamamen şarj edildi Nízký stav baterieNabíjí seBaterie plně nabitá Akkufeszültség alacsonyTöltésTeljesen feltöltve Χαμηλή μπαταρίαΕπαναφόρτισηΠλήρως φορτισμένο แบตเตอรี่ต่ํากําลังชาร์จชาร์จเต็มแล้ว נמוכה קיבולת ‘”…•– ‘— טוען إ دة š™˜ במלואו טעון › ˜™š Slow Flash *Please unplug when fully charged USB Type-C Fokus+ will automatically reconnect to your device when removed from the Charging Stand. หลังจากถอดออกจากแทนชารจ FOKUS+ จะเชื่อมตอกับอุปกรณของคุณอีกครั้งโดยอัตโนมัติ После снятия с подставки для зарядки …

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 ONANOFF LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 5, 2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: (2AN2MONFPWC) [ONANOFF LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, AGNES YEUNG Rev 1/26/2023 ONANOFF LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 5, 2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: (2AN2MONFPWC) [ONANOFF LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, AGNES YEUNG

Attestation Statements

Rev 1/26/2023 ONANOFF LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 5, 2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID or Grantee Code: [2AN2MONFPWC] Applicant FRN: [0026926931] [ONANOFF LTD] (“the applicant”) certifies that, as of the date of the filing of the application, [ONANOFF LLC] is our designated U.S. agent for service of process for the above referenced FCC ID. [ONANOFF LTD] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. [ONANOFF LLC] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: [ONANOFF LLC] U.S. Agent FRN: 0033411646 Address: 202 Canal Street, Suite 303, New York, New York, 10013, United States Contact Person: Agnes Yeung Tel.: 646 850 5888 Email: [email protected] Sincerely, ONANOFF LTD ONANOFF LLC AGNES YEUNG Agnes Yeung [Insert Applicant signature] [U.S. Agent signature]

Attestation Statements

ONANOFF LTD RM 424 SINO IND PLAZA, 9 KAI CHEUNG ROAD, KOWLOON BAY, HONG KONG Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: September 15, 2023 SUBJECT: To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class B computer peripheral portion of this composite device. I understand the following FCC requirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain the name, address, and phone number of the responsible party, which must be located within the United States. According to 2.909(b), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, ONANOFF LTD ------------------------------- AGNES YEUNG

Cover Letter(s)

Rev 11/20/07 ONANOFF LTD Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AN2MONFPWC Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (Block Diagram, Schematics, Operational Description) (Block Diagram, SCH, Technical Description) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below within xx days from the date of submitting the FCC: Exhibit Type File Name Sincerely, (signature) (printed name) AGNES YEUNG

Cover Letter(s)

ONANOFF LIMITED Declaration Letter Dear BUREAU VERITAS For our business issue and marketing requirement, we would like to list 4 model numbers on the CE, FCC, IC, UKCA, CB & MIC certificates and reports, as following: Model No.: We declare that the difference of these is listed as below: Main Model No Serial Model No Difference ON-FOKUSP-WC ON-SPP-WC, ON-FW-WC Color Thank you! Signature: Printed name/title: Tel: Fax: Address: RM 424, Sino Ind. Plaza, 9 Kai Cheung Road, Kowloon Bay, Kowloon, Hong Kong ON-WC FCC ID: 2AN2MONFPWC AGNES YEUNG (852) 23930306

Cover Letter(s)

ONANOFF LTD Federal Communications Commission Authorization and Evaluation Division 7 435 Oakland Mills Road Columbia, MD 21046 Date: 2023.9.5 SUBJECT: FCC Application for FCC ID: 2AN2MONFPWC To Whom It May Concern: We, the undersigned, hereby authorize _Glyn He by_Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch at No. 96, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Glyn He Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, (Signature): (Printed Name): AGNES YEUNG

External Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 5 Report Version A Reference No.: 2206WDG0262-3 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 5 Report Version A Reference No.: 2206WDG0262-3 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 5 Report Version A Reference No.: 2206WDG0262-3 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 5 Report Version A Reference No.: 2206WDG0262-3 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 5 Report Version A Reference No.: 2206WDG0262-3

ID Label/Location Info

Model: ON-FOKUSP-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA Model: ON-FOKUSP-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA label 34x58mm Product Spec Lable Bottom of stand Model: ON-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA Model: ON-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA label 34x58mm Product Spec Lable Bottom of stand Model: ON-SPP-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA Model: ON-SPP-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA label 34x58mm Product Spec Lable Bottom of stand Model: ON-FW-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA Model: ON-FW-WC Input: 5V1A Output: 5V0.5A FCC ID: 2AN2MONFPWC IC: 27546-FKPWC MADE IN CHINA label 34x58mm Product Spec Lable Bottom of stand

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version A Reference No.: 2206WDG0262-3 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version A Reference No.: 2206WDG0262-3 Wireless charger ANT. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version A Reference No.: 2206WDG0262-3 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version A Reference No.: 2206WDG0262-3

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 9 Report Version 1 Test Report No.: FM2206WDG0262-2 RF EXPOSURE TEST REPORT Applicant ONANOFF LIMITED Address RM 424, Sino Ind. Plaza, 9 Kai Cheung Road, Kowloon Bay, Kowloon, Hong Kong Manufacturer or Supplier ONANOFF LIMITED Address RM 424, Sino Ind. Plaza, 9 Kai Cheung Road, Kowloon Bay, Kowloon, Hong Kong Product Onanoff Wireless Charger Brand Name Model ON-FOKUSP-WC Additional Model & Model Difference ON-WC, ON-SPP-WC, ON-FW-WC, See section 1.1 Date of tests Sep. 18, 2023 The submitted sample of the above equipment has been tested according to the requirements of the following standard: 47 CFR PART 1, Subpart I, Section 1.1310 KDB 680106 D01 V03r01 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Eric Fang Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Sep. 19, 2023 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 9 Report Version 1 Test Report No.: FM2206WDG0262-2 TABLE OF CONTENTS RF EXPOSURE TEST REPORT ................................................................................................................1 RELEASE CONTROL RECORD ..................................................................................................................3 1. GENERAL INFORMATION ..................................................................................................................4 1.1. GENERAL DESCRIPTION OF EUT ............................................................................................4 2. RF EXPOSURE MEASUREMENT ......................................................................................................5 2.1 LIMITS .........................................................................................................................................5 2.2 DESCRIPTION OF SUPPORT UNITS ........................................................................................5 2.3 CONFIGURATION OF SYSTEM UNDER TEST .........................................................................6 2.4 TEST SETUP FOR WPT .............................................................................................................6 2.5 EQUIPMENTS USED DURING TEST.........................................................................................7 2.6 TEST POINT DESCRIPTION ......................................................................................................7 2.7 TEST RESULTS ..........................................................................................................................8 3. PHOTOGRAPHS OF THE TEST CONFIGURATION..........................................................................9 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 9 Report Version 1 Test Report No.: FM2206WDG0262-2 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2206WDG0262-2 Original release Sep. 19, 2023 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 9 Report Version 1 Test Report No.: FM2206WDG0262-2 1. GENERAL INFORMATION 1.1. GENERAL DESCRIPTION OF EUT FCC ID 2AN2MONFPWC PRODUCT Onanoff Wireless Charger MODEL NO. ON-FOKUSP-WC ADDITIONAL MODEL ON-WC, ON-SPP-WC, ON-FW-WC POWER SUPPLY Input:5V/1A Output:5V/0.5A MAX. OUTPUT POWER FROM THE PRIMARY COIL 2.5W MODULATION TECHNOLOGY FSK OPERATING FREQUENCY RANGE 110KHz ~ 205KHz ANTENNA TYPE Coil Antenna I/O PORTS Refer to user’s manual CABLE SUPPLIED AUX cable: Unshielded, detachable, 1.3m…

Text truncated - open the document above for the full version.

Test Report

Product Specifications sheet Specification No.202309016001 Effective date2023/9/16 Customer Name:极加创新 Product Model DZ Part No. TX-DZ4005.3010-12T-K6.3-L40(Billing slot) Customer item No 【 □ New issue , □ version revision】 【 This specification includes contents and 7 pages in total 】 【 RoHS Compliant Parts 】 organizeCheckApproval 钟建立 / 马湘平 Dongguan Top Wiser Electronic Technology Co., Ltd Factory address: 7th floor, east of building , xinbosheng Industrial Park, No. 5, Xinyuan South Road, Tangxia Town, Dongguan City Tel: 13147097490 【Within 30 days after the customer receives this acknowledgement, please return it with your signature and seal. If it is overdue, it will be deemed that the production will be carried out according to the standards of this acknowledgement】. 【customer approval】 Date: Recognition status: □ full recognition □ conditional recognition □ refusal Approval Review Recheck Check remark: √ √ Product Specifications sheet Customer Name:极加创新 Customer item No DZ Part No. TX-DZ4005.3010-12T-K6.3-L40(Billing slot) Specification No. 202309016001 Issue/Revision History VersionEffective dateChange content / reasonApproval 012023/9/16 New specification release马湘平 organizecheckapproval 钟建立 / 马湘平 Product Specifications sheet Customer Name:极加创新 Customer item No DZ Part No TX-DZ4005.3010-12T-K6.3-L40(Billing slot)Specification No.202309016001 Version 01 ♦、Overall dimensions (unit: mm) A40.0 ±1.5 B5.3 ±1.5 C39.0 ±1.5 D13.8 ±1.5 E40.0 ±2.0 F3.0 ±2.0 G2.4 ±0.3 (1)Wire diameter: 0.08 * 105p Silk covered wire (2)Number of windings: 12TS (3)Whether the starting and ending lines cross: Yes (4)Coil wrap 6mm wide high temperature tape (5)The coil and magnetic sheet shall be pasted in the center (6)White glue on the diskette ♦、Electrical characteristics:: parameterspecificationTest conditionsTest instrument L06.3±10%μH100KHz/1V■TH1816B Q>30 min100KHz/1V■TH1816B DCR<95mΩ@ 25 °C ■CH-502BC ♦、Temperature class: Operating temperature -40°C~ 125°C peak Gain:0dbi ♦、list of materials: Item Product Name Material specification SupplierRemark 1Magnetic sheet40*5.3*1.0T Billing slot PC40 mengzinc 2 Copper wire0.08*105PPropane copper covered wire 3 High temperature adhesive tape 6MMRosh tape 4 glue White glue Rosh tape 5 tin107HROSH tin 6 glue黄胶yellow glueROSH glue organizecheckapproval 钟建立 / 马湘平

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 27 Report Version 1 Test Report No.: RF2206WDG0262-2 TEST REPORT Applicant ONANOFF LIMITED Address RM 424, Sino Ind. Plaza, 9 Kai Cheung Road, Kowloon Bay, Kowloon, Hong Kong Manufacturer or Supplier ONANOFF LIMITED Address RM 424, Sino Ind. Plaza, 9 Kai Cheung Road, Kowloon Bay, Kowloon, Hong Kong Product Onanoff Wireless Charger Brand Name Model ON-FOKUSP-WC Additional Model & Model Difference ON-WC, ON-SPP-WC, ON-FW-WC, See section 3.1 Date of tests Aug. 06, 2023 ~ Aug. 21, 2023 The submitted sample of the above equipment has been tested for according to the requirements of the following standards: FCC Part 15, Subpart C CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Eric Fang Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Sep. 06, 2023 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 27 Report Version 1 Test Report No.: RF2206WDG0262-2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 3 1 SUMMARY OF TEST RESULTS ..................................................................................................... 4 2 MEASUREMENT UNCERTAINTY .................................................................................................. 4 3 GENERAL INFORMATION .............................................................................................................. 5 3.1 GENERAL DESCRIPTION OF EUT ......................................................................................... 5 3.2 DESCRIPTION OF TEST MODES ........................................................................................... 6 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 6 3.4 DESCRIPTION OF SUPPORT UNITS ..................................................................................... 6 4 EMISSION TEST .............................................................................................................................. 7 4.1 CONDUCTED EMISSION MEASUREMENT ........................................................................... 7 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................................. 7 4.1.2 TEST INSTRUMENTS ....................................................................................................... 7 4.1.3 TEST PROCEDURE .......................................................................................................... 8 4.1.4 DEVIATION FROM TEST STANDARD ............................................................................. 8 4.1.5 TEST SETUP ..................................................................................................................... 9 4.1.6 EUT OPERATING CONDITIONS ...........…

Text truncated - open the document above for the full version.

Contact Information

Applicant

AGNES YEUNG(OPERATION MANAGER)
[email protected]23930306Fax: N/A

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from ONANOFF LTD

FOKUS+, BuddyPhones CosmosFun, StudyPhones+, FireWork - FCC ID 2AN2MONFOKUSP - ONANOFF LTD
2AN2MONFOKUSP

FOKUS+, BuddyPhones CosmosFun, StudyPhones+, FireWork

Sep 26, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter