FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CJ Global Inc./
  3. 2AND8-CHG3N1

2AND8-CHG3N13-In-1 Fast Wireless Charging Station

CJ Global Inc.
3-In-1 Fast Wireless Charging Station - FCC ID 2AND8-CHG3N1 - CJ Global Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Aug 07, 2023
Application Purpose
Original Equipment
Date of Application
Aug 07, 2023
Equipment Note
3-In-1 Fast Wireless Charging Station
Frequency Range
0.11000000 - 0.20500000
Company
CJ Global Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Déclaration de la FCC Cet appareil est conforme à la partie 15 des règles de la FCC. Le fonctionnement est soumis aux deux conditions suivantes: (1) ce dispositif ne peut pas causer dinterférences nuisibles, et (2) ce dispositif doit accepter toute interférence reçue, y compris linterférence qui peut causer un fonctionnement indésirable. Attention: modifications ou modifications non expressément approuvées par le responsable de La conformité pourrait annuler lautorisation de lutilisateur de faire fonctionner léquipement. Remarque: cet équipement a été testé et jugé conforme aux limites pour un appareil numérique de classe B, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère des utilisations et peut émettre de lénergie de radiofréquence et, sil nest pas installé et utilisé conformément aux instructions, peut causer des interférences nuisibles aux communications radio. Cependant, rien ne garantit que des interférences ne se produiront pas dans une installation particulière. Si cet équipement provoque des interférences nuisibles à la réception de la radio ou de la télévision, qui peuvent être déterminées en éteignant et en allumant léquipement, lutilisateur est encouragé à essayer de corriger linterférence par une ou plusieurs des mesures suivantes: réorienter ou déplacer lantenne de réception. - augmentez la séparation entre léquipement et le récepteur. branchez léquipement sur une prise sur un circuit différent de celui auquel le récepteur est connecté. consultez le concessionnaire ou un technicien radio/TV expérimenté pour obtenir de laide annonce importante Déclaration dexposition aux rayonnements Cet appareil est conforme aux limites dexposition aux rayonnements RF de la FCC établies pour un environnement non contrôlé. Cet émetteur ne doit pas être localisé ou fonctionner en conjonction avec FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help important announcement Radiation Exposure Statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. une autre antenne ou un autre émetteur. Pendant le fonctionnement du dispositif, une distance de 15 cm autour du dispositif et de 20 cm au-dessus de la surface supérieure du dispositif doit être respectée.

External Photos

Test Report Number: BTF230628R01201 Appendix EUT Photos for BTF230628R01201 Test Report Number: BTF230628R01201 External Test Report Number: BTF230628R01201 Test Report Number: BTF230628R01201 Test Report Number: BTF230628R01201

ID Label/Location Info

Test Report Number: BTF230628R01202 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 1 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China LABEL AND LOCATION Label location

Internal Photos

Test Report Number: BTF230628R01201 Appendix EUT Photos for BTF230628R01201 Test Report Number: BTF230628R01201 Internal Antenna Test Report Number: BTF230628R01201 Antenna Test Report Number: BTF230628R01201 Antenna Test Report Number: BTF230628R01201 Test Report Number: BTF230628R01201 Test Report Number: BTF230628R01201

RF Exposure Info

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 13 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Exposure Report For Applicant Name: Cj Global Inc. Address: 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States EUT Name: 3-In-1 Fast Wireless Charging Station Brand Name: N/A Model Number: 71561-DI Series Model Number: Refer to section 2 Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF230628R01202 Test Standards: 47 CFR Part 1 Subpart I Section 1.1310 FCC ID: 2AND8-CHG3N1 Test Conclusion: Pass Test Date: 2023-06-20 to 2023-06-27 Date of Issue: 2023-07-11 Prepared By: Elma. Yang / Project Engineer Date: 2023-07-11 Approved By: Ryan CJ / EMC Manager Date: 2023-07-11 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF230628R01202 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 13 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 Jul. 11 th 2023 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF230628R01202 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 13 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1. Introduction ............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 2.5 Technical Information........................................................................................................................................................... 5 3. Test Requirement ................................................................................................................................................................................. 6 3.1 Assessment Result ............................................................................................................................................................... 8 3.2 Test Set-up Photo .................................................................................................................................................................. 9 Test Report Number: BTF230628R01202 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 4 of 13 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China 1. Introduction 1.1 Identification of Testing Laboratory Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Phone Number: +86-0755-23146130 Fax Number: +86-0755-23146130 1.2 Identification of the Responsible Testing Location Test Location: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Description: All measurement facilities used to collect the measurement data are located at F101,201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China FCC Registration Number: 518915 Designation Number: CN1330 1.3 Labor…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Mingyuxing Technology Co., Ltd 1. Antenna1 Description: Antenna type: loop coil Antenna Manufacturer: Shenzhen Mingyuxing Technology Co., Ltd Model:CHG3N1-BL antenna Antenna Gain(Peak): 0 dBi Frequency range:110kHz -205kHz 2. Antenna1 Photo: Shenzhen Mingyuxing Technology Co., Ltd 3. Antenna2 Description: Antenna type: loop coil Antenna Manufacturer: Shenzhen Mingyuxing Technology Co., Ltd Model:CHG3N1-BL antenna Antenna Gain(Peak): 0 dBi Frequency range:110kHz -205kHz 4. Antenna2 Photo: Antennaφ=25mm Zero Pole (Dongguan) Intelligent Technology Co., Ltd 5. Antenna3 Description: Antenna type: loop coil Antenna Manufacturer: Shenzhen Mingyuxing Technology Co., Ltd Model:CHG3N1-BL antenna Antenna Gain(Peak): 0 dBi Frequency range:300kHz -350kHz 6. Antenna3 Photo: Antennaφ=12mm

Test Report

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 30 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Test Report For Applicant Name: Cj Global Inc. Address: 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States EUT Name: 3-In-1 Fast Wireless Charging Station Brand Name: N/A Model Number: 71561-DI Series Model Number: Refer to section 2 Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF230628R01201 Test Standards: 47 CFR Part 15 Subpart C FCC ID: 2AND8-CHG3N1 Test Conclusion: Pass Test Date: 2023-06-20 to 2023-06-27 Date of Issue: 2023-07-11 Prepared By: Elma. Yang / Project Engineer Date: 2023-07-11 Approved By: Ryan CJ / EMC Manager Date: 2023-07-11 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF230628R01201 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 30 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2023-07-11 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF230628R01201 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 30 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1. Introduction ............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 2.5 Technical Information........................................................................................................................................................... 5 3. Summary of Test Results .................................................................................................................................................................... 6 3.1 Test Standards ....................................................................................................................................................................... 6 3.2 Summary of Test Result ...................................................................................................................................................... 6 3.3 Uncertainty of Test ................................................................................................................................................................ 6 4. Test Configuration ................................................................................................................................................................................ 8 4.1 Environment Condition ........................................................................................................................................................ 8 4.2 Test Equipment List .............................................................................................................................................................. 8 4.3 Test Auxiliary Equipment .................................................................................................................................................... 9 4.4 Test Setup ............................................................................................................................................................................. 10 5. Test Items ...........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Report Number: BTF230628R01201 Appendix Setup Photos for BTF230628R01201 Test Report Number: BTF230628R01201 Radiated Emissions Test Report Number: BTF230628R01201 Power Line Conducted Emissions

Contact Information

Applicant

Coby Chen(Manager)
[email protected]646 415 9056Fax: 201 509 8181

Test Firm

BTF Testing Lab (Shenzhen) Co., Ltd.Ryan CJ
[email protected]8675523146130

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from CJ Global Inc.

2AND8-71485-BO

Bobcat Neckband Headphones

Jul 31, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TWS EARBUDS - FCC ID 2AND8-TWS2304 - CJ Global Inc.
2AND8-TWS2304

TWS EARBUDS

May 22, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AND8-CH2207

4-in-1 Fast Wireless Charging Station With Lamp

Jul 25, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Karaoke Wireless Microphone - FCC ID 2AND8-BT2205 - CJ Global Inc.
2AND8-BT2205

Karaoke Wireless Microphone

Jul 19, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Flex Neck Lamp Wireless Charger - FCC ID 2AND8-24724 - CJ Global Inc.
2AND8-24724

Flex Neck Lamp Wireless Charger

Aug 09, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz