  2. Eggtronic Engineering Spa/
  3. 2ANP7MPWH2X

2ANP7MPWH2XDual Marble - wireless charging stone

Eggtronic Engineering Spa
Dual Marble - wireless charging stone - FCC ID 2ANP7MPWH2X - Eggtronic Engineering Spa
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 20, 2020
Application Purpose
Original Equipment
Date of Application
May 20, 2020
Equipment Note
Dual Marble - wireless charging stone
Frequency Range
0.12500000 - 0.12500000
Company
Eggtronic Engineering Spa
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1RWVXSSRUWLQJFKDUJHWZRGHYLFHVDWWKHVDPHWLPH

Cover Letter(s)

Eggtronic Engineering Srl Agent Authorization Company: Eggtronic Engineering Srl Address: Via Giorgio Campagna 8 Modena, 41126 Italy Product Name: Dual Marble - wireless charging stone Model Number(s): MPWH2X, SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X Product Description: Dual Marble - wireless charging stone We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: May. 12, 2020 Name: Igor Spinella Title: CEO Company: Eggtronic Engineering Srl

Cover Letter(s)

Eggtronic Engineering Srl Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: May. 12, 2020 Subject; Request for Confidentiality FCC ID: 2ANP7MPWH2X To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Igor Spinella Title: CEO

Cover Letter(s)

Model Difference Declaration To Whom It May Concern, We, Eggtronic Engineering Srl(Dual Marble - wireless charging stone) Trademark:EGGTRONIC; Model Number: MPWH2X, SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X ;All model’s the function, software and electric circuit are the same, only with a product color and model named different for commercial purpose. Test sample model: MPWH2X. Please contact me if you have any question. Name: Igor Spinella Date: May. 12, 2020 Title: CEO Signature of applicant:

External Photos

Annex A External Photos Report No.: HK2003270519-1E/2E/3E Page 1 of 4 Report No.: HK2003270519-1E/2E/3E Page 2 of 4 Report No.: HK2003270519-1E/2E/3E Page 3 of 4 Report No.: HK2003270519-1E/2E/3E Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location Width: 2cm Long: 4cm FCC ID: 2ANP7MPWH2X Product name: Dual Marble - wireless charging stone Model No.: MPWH2X This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Annex B Internal Photo Report No.: HK2003270519-1E/2E/3E Page 1 of 5 Report No.: HK2003270519-1E/2E/3E Page 2 of 5 Antenna 1 Antenna 2 Report No.: HK2003270519-1E/2E/3E Page 3 of 5 Report No.: HK2003270519-1E/2E/3E Page 4 of 5 Report No.: HK2003270519-1E/2E/3E Page 5 of 5

RF Exposure Info

Page 1 of 8 Report No.: HK2003270519-3E FCC TEST REPORT Test report On Behalf of Eggtronic Engineering Srl For Dual Marble - wireless charging stone Model No.: MPWH2X, SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X FCC ID: 2ANP7MPWH2X Prepared for : Eggtronic Engineering Srl Via Giorgio Campagna 8 Modena, 41126 Italy Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Mar. 26, 2020 ~April. 02, 2020 Date of Report: April. 02, 2020 Report Number: HK2003270519-3E Page 2 of 8 Report No.: HK2003270519-3E Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 125 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. SUMMARY OF TEST RESULTS 2.1 Test procedures according to the technical standards: FCC KDB680106 D01 RF Exposure Wireless Charging Apps v03 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB680106 D01v03 (3)(3) Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 All emissions,radiated(<30M)(9KHz-30MHz) ±2.45dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 3 of 8 Report No.: HK2003270519-3E 2.3 Test Instruments Description Brand Model No. Frequency Range Calibrated Date Calibrated Until Broadband Field Meter NARDA NBM-550 - Dec. 26, 2019 Dec. 25, 2020 Magnetic Field Meter NARDA ELT-400 1 – 400kHz Dec. 26, 2019 Dec. 25, 2020 Magnetic Probe NARDA HF-3061 300kHz – 30MHz Dec. 26, 2019 Dec. 25, 2020 Magnetic Probe NARDA HF-0191 27 – 1000MHz Dec. 26, 2019 Dec. 25, 2020 Broadband Field Meter NARDA NBM-550 - Dec. 26, 2019 Dec. 25, 2020 Electric Field Meter COMBINOVA EFM 2005Hz – 400kHz Dec. 26, 2019 Dec. 25, 2020 E-Field Probe NARDA EF-0391 100kHz – 3GHz Dec. 26, 2019 Dec. 25, 2020 E-Field Probe NARDA EF-6091 100MHz – 60GHz Dec. 26, 2019 Dec. 25, 2020 NOTE: 1. The calibration interval of the above test instruments is 12 months . Page 4 of 8 Report No.: HK2003270519-3E 3. MAXIMUM PERMISSIBLE EXPOSURE 3.1 MAXIMUM PERMISSIBLE EXPOSURE Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz ; *Plane-wave equivalent power density Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03 Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 5 of 8 Report No.: HK2003270519-3E 4. TEST PROCEDURE a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of (H-field & E- field strengths for all sides is 15cm, H-field strengths of top side is 20cm). E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. 4.1 TEST SETUP 4.2 RESULT OF MAXIMUM PERMISSIBLE EXPOSURE All the test modes completed for test. only the worst result was reported as below: Page 6 of 8 Report No.: HK2003270519-3E For Full load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.23 1.35 1.56 1.48 1.42 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.35 0.39 0.43 0.48 0.31 1.63 For Half Load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.45 1.41 1.32 1.39 1.38 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.33 0.44 0.47 0.14 0.35 1.63 Page 7 of 8 Report No.: HK2003270519-3E For No load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.42 1.34 1.35 1.15 1.33 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.19 0.37 0.39 0.24 0.32 1.63 Remark: According KDB 680106 D01 RF Exposure Wireless Charging App v03, section 5, b). The aggregate H-field strengths at 15 cm surrounding the device an…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 21 Report No.: HK2003270519-1E FCC TEST REPORT Test report On Behalf of Eggtronic Engineering Srl For Dual Marble - wireless charging stone Model No.: MPWH2X, SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X FCC ID: 2ANP7MPWH2X Prepared for : Eggtronic Engineering Srl Via Giorgio Campagna 8 Modena, 41126 Italy Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Mar. 26, 2020 ~Apr. 02, 2020 Date of Report: Apr. 02, 2020 Report Number: HK2003270519-1E Page 2 of 21 Report No.: HK2003270519-1E TEST RESULT CERTIFICATION Applicant’s name ................. : Eggtronic Engineering Srl Address ................................. : Via Giorgio Campagna 8 Modena, 41126 Italy Manufacture's Name ............ : Eggtronic Engineering Srl Address ................................. : Via Giorgio Campagna 8 Modena, 41126 Italy Product description Trade Mark: EGGTRONIC Product name ........................... : Dual Marble - wireless charging stone Model and/or type reference : MPWH2X, SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X Standards ............................. : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : Mar. 26, 2020 ~Apr. 02, 2020 Date of Issue ........................................... : Apr. 02, 2020 Test Result ............................................... : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 21 Report No.: HK2003270519-1E Table of Contents Page 1 . TEST SUMMARY 5 1.1 TEST PROCEDURES AND RESULTS 5 1.2 TEST FACILITY 5 1.3 MEASUREMENT UNCERTAINTY 5 2. GENERAL INFORMATION 6 2.1 General Description of EUT 6 2.2. Carrier Frequency of Channels 6 2.2. Carrier Frequency of Channels 7 2.3 Operation of EUT during testing 7 2.4 Description of Test Setup 7 2.5 Measurement Instruments List 8 3. CONDUCTED EMISSION TEST 9 3.1 Block Diagram of Test Setup 9 3.2 Conducted Power Line Emission Limit 9 3.3 Test Procedure 9 4. Occupied Bandwidth 12 4.1 Block Diagram of Test Setup 12 4.2 Rules and specifications 12 4.3 Test Procedure 12 4.4 Test Result 12 5. RADIA TED EMISSIONS 14 5.1 Block Diagram of Test Setup 14 5.2 Rules and specifications 15 5.3 Test Procedure 16 5.4 Test Result 16 6 ANTENNA REQUIREMENT 19 7. PHOTOGRAPH OF TEST 20 7.1 Radiated Emission 20 8 PHOTOS OF THE EUT 21 Page 4 of 21 Report No.: HK2003270519-1E ** Modifited History ** Revison Description Issued Data Remark Revsion 1.0 Initial Test Report Release Apr. 02, 2020 Jason Zhou Page 5 of 21 Report No.: HK2003270519-1E 1. TEST SUMMARY 1.1 TEST PROCEDURES AND RESULTS DESCRIPTION OF TEST section number RESULT CONDUCTED EMISSIONS TEST 15.207 COMPLIANT RADIATED EMISSION TEST 15.209 COMPLIANT OCCUPIED BANDWIDTH MEASUREMENT 15.215 COMPLIANT ANTENNA REQUIREMENT 15.203 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2 TEST FACILITY Test Firm : Shenzhen HUAK Testing Technology Co., Ltd. Address 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China 1.3 MEASUREMENT UNCERTAINTY Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.23dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.08dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 4.42dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.06dB, k=2 Page 6 of 21 Report No.: HK2003270519-1E 2. GENERAL INFORMATION 2.1 General Description of EUT Equipment Dual Marble - wireless charging stone Model Name MPWH2X Serial No. SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X Model Difference All model’s the function, software and electric circuit are the same, only with a product color and model named different. Test sample model: MPWH2X Trade Mark EGGTRONIC FCC ID 2ANP7MPWH2X Antenna Type Coil Antenna Antenna Gain 0dBi BT Operation frequency 125KHz Number of Channels 1 Modulation Type ASK Power Source DC 12V, 2A from AC Adapter with AC100-240V~50-60Hz, 0.8A Power Rating DC 12V, 2A from AC Adapter with AC100-240V~50-60Hz, 0.8A Output Power: 5W/7.5W/10W NOTE: This report is test result for ANT1, ANT2 test result see report: HK2003270519-2E. Page 7 of 21 Report No.: HK2003270519-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency 1 125KHz 2.3 Operation of EUT during testing Operating Mode The mode is used: Transmitting mode 2.4 Description of Test Setup Operation of EUT during conducted testing and Radiation testing: AC Plug ● Adapter information Model: SAW30A-120-2000U Input: 100-240V~50-60Hz, 0.8A Output:12V, 2A Mobile phone information Model: Samsung S6 The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pa…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 21 Report No.: HK2003270519-2E FCC TEST REPORT Test report On Behalf of Eggtronic Engineering Srl For Dual Marble - wireless charging stone Model No.: MPWH2X, SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X FCC ID: 2ANP7MPWH2X Prepared for : Eggtronic Engineering Srl Via Giorgio Campagna 8 Modena, 41126 Italy Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Mar. 26, 2020 ~Apr. 02, 2020 Date of Report: Apr. 02, 2020 Report Number: HK2003270519-2E Page 2 of 21 Report No.: HK2003270519-2E TEST RESULT CERTIFICATION Applicant’s name ................. : Eggtronic Engineering Srl Address ................................. : Via Giorgio Campagna 8 Modena, 41126 Italy Manufacture's Name ............ : Eggtronic Engineering Srl Address ................................. : Via Giorgio Campagna 8 Modena, 41126 Italy Product description Trade Mark: EGGTRONIC Product name ........................... : Dual Marble - wireless charging stone Model and/or type reference : MPWH2X, SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X Standards ............................. : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : Mar. 26, 2020 ~Apr. 02, 2020 Date of Issue ........................................... : Apr. 02, 2020 Test Result ............................................... : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 21 Report No.: HK2003270519-2E Table of Contents Page 1 . TEST SUMMARY 5 1.1 TEST PROCEDURES AND RESULTS 5 1.2 TEST FACILITY 5 1.3 MEASUREMENT UNCERTAINTY 5 2. GENERAL INFORMATION 6 2.1 General Description of EUT 6 2.2. Carrier Frequency of Channels 7 2.3 Operation of EUT during testing 7 2.4 Description of Test Setup 7 2.5 Measurement Instruments List 8 3. CONDUCTED EMISSION TEST 9 3.1 Block Diagram of Test Setup 9 3.2 Conducted Power Line Emission Limit 9 3.3 Test Procedure 9 4. Occupied Bandwidth 12 4.1 Block Diagram of Test Setup 12 4.2 Rules and specifications 12 4.3 Test Procedure 12 4.4 Test Result 12 5. RADIA TED EMISSIONS 14 5.1 Block Diagram of Test Setup 14 5.2 Rules and specifications 15 5.3 Test Procedure 16 5.4 Test Result 16 6 ANTENNA REQUIREMENT 19 7. PHOTOGRAPH OF TEST 20 7.1 Radiated Emission 20 8 PHOTOS OF THE EUT 21 Page 4 of 21 Report No.: HK2003270519-2E ** Modifited History ** Revison Description Issued Data Remark Revsion 1.0 Initial Test Report Release Apr. 02, 2020 Jason Zhou Page 5 of 21 Report No.: HK2003270519-2E 1. TEST SUMMARY 1.1 TEST PROCEDURES AND RESULTS DESCRIPTION OF TEST section number RESULT CONDUCTED EMISSIONS TEST 15.207 COMPLIANT RADIATED EMISSION TEST 15.209 COMPLIANT OCCUPIED BANDWIDTH MEASUREMENT 15.215 COMPLIANT ANTENNA REQUIREMENT 15.203 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2 TEST FACILITY Test Firm : Shenzhen HUAK Testing Technology Co., Ltd. Address 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China 1.3 MEASUREMENT UNCERTAINTY Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.23dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.08dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 4.42dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.06dB, k=2 Page 6 of 21 Report No.: HK2003270519-2E 2. GENERAL INFORMATION 2.1 General Description of EUT Equipment Dual Marble - wireless charging stone Model Name MPWH2X Serial No. SSP2X, LP2X, MPBK2X, TP2X, WMP2X, CMP2X Model Difference All model’s the function, software and electric circuit are the same, only with a product color and model named different. Test sample model: MPWH2X Trade Mark EGGTRONIC FCC ID 2ANP7MPWH2X Antenna Type Coil Antenna Antenna Gain 0dBi BT Operation frequency 125KHz Number of Channels 1 Modulation Type ASK Power Source DC 12V, 2A from AC Adapter with AC100-240V~50-60Hz, 0.8A Power Rating DC 12V, 2A from AC Adapter with AC100-240V~50-60Hz, 0.8A Output Power: 5W/7.5W/10W Page 7 of 21 Report No.: HK2003270519-2E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency 1 125KHz 2.3 Operation of EUT during testing Operating Mode The mode is used: Transmitting mode 2.4 Description of Test Setup Operation of EUT during conducted testing and Radiation testing: AC Plug ● Adapter information Model: SAW30A-120-2000U Input: 100-240V~50-60Hz, 0.8A Output:12V, 2A Mobile phone information Model: Samsung S6 The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. The worst case is X position AC Adapter EUT Mobile phone Page 8 of 21 Report No.: HK2003270519-2E 2.5 Measurement Instrum…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Radiated Emissions

Test Setup Photos

Conducted Emission Radiated Emissions

Contact Information

Applicant

Igor Spinella(CEO)
[email protected]00390597878110Fax: 00390599786751

Technical Contact

Eggtronic Engineering Srl
[email protected]

Italy

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]+86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Eggtronic Engineering Spa

Wireless Charging stone - FCC ID 2ANP7-EG10 - Eggtronic Engineering Spa
2ANP7-EG10

Wireless Charging stone

Apr 24, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
MUNDUS PRO - FCC ID 2ANP7WP0403020 - Eggtronic Engineering Spa
2ANP7WP0403020

MUNDUS PRO

Nov 09, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Triple coil embedded wireless charging system - FCC ID 2ANP7EGG190098 - Eggtronic Engineering Spa
2ANP7EGG190098

Triple coil embedded wireless charging system

Aug 03, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz