Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PHOENIX 500 Portable Power Station Version A0 - 01 - APPLICABILITY The User Manual applies to the following product: • PHOENIX 500 Portable Power Station (RPS5080AA-PCS) DISCLAIMER • User Manual because continuous product improvements are going to be made. • Renogy assumes no responsibility or liability for losses or damages, whether direct, indirect, consequential, or incidental, which might arise out of the use of information in the User Manu- al. • Renogy is not responsible or liable for the failures, damages, or injuries resulting from repair • The illustrations in the User Manual are for demonstration purposes only. Details may appear • Renogy reserves the right to change the information in the User Manual without notice. COPYRIGHT PHOENIX 500 Portable Power Station User Manual © 2022 Renogy. All rights reserved. All information in the User Manual is subject to copyright and other intellectual property rights whole or in part, without the prior written permissions of Renogy and its licensors. TRADEMARKS The following are trademarks or registered trademarks of Renogy in the United States and other countries: RENOGY All other trademarks in the User Manual are the property of their respective owners and their use herein does not imply sponsorship or endorsement of their products or services. The unau- thorized use of any trademark displayed in the User Manual or on the product is strictly prohibit- ed. - 02 - Import ant Safety Instructions Please save these instructions. The User Manual provides important operation and maintenance instructions for PHOENIX 500 Portable Power Station. Please read the User Manual carefully before operation and save it for future reference. Failure to observe the instructions or precautions in the User Manual can result in electrical shock, serious injury, or death, or can damage PHOENIX, potentially rendering it inoperable. Symbols Used The following symbols are used throughout the User Manual to highlight important information. Indicates a potentially dangerous condition which could result in injury or death. Indicates a critical procedure for safe and proper installation and operation. Indicates an important step or tip for optimal performance. General Safety Information • DO NOT immerse PHOENIX in water or leave it out in the rain. • DO NOT puncture, drop, crush, penetrate, shake, strike, or step on PHOENIX. • DO NOT open, dismantle, repair, tamper with, or modify PHOENIX. • DO NO insert foreign objects into the casing or outlets of PHOENIX. • • • • Please keep PHOENIX away from heating equipment. • DO NOT touch the exposed electrolyte or powder if PHOENIX is damaged. • DO NOT use PHOENIX with life support equipment or other medical equipment. • Please keep PHOENIX out of the reach of young children. • DO NOT dispose of PHOENIX as household waste. Please recycle PHOENIX in accordance with local, state, and federal regulations. • Please inspect PHOENIX before each use. Stop using PHOENIX if any visible damages in- cluding cracks, dents, and deformation or abnormalities including unusual smells and heating are observed. - 03 - • • • • Please ensure that no water sources including downspouts, sprinklers, or faucets are above or near PHOENIX. • Please ensure that snow does not accumulate around PHOENIX. • DO NOT lean on, stack anything on top of, or hang anything from PHOENIX or from cables leading to PHOENIX. • Please ensure that PHOENIX is securely fastened during transportation. - 04 - Table of Contents Product Overview -----------------------------------------------------05 ------------------------------------------------05 Package Content----------------------------------------------------07 LCD Display----------------------------------------------------------08 Operation -----------------------------------------------------------10 ----------------------------------------------------10 DC Home Connection -----------------------------------------------10 Charging ---------------------------------------------------------13 Powering Devices - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 Standby Power Supply (SPS) ------------------------------------------17 Parallel Connection--------------------------------------------------18 Strip Lights Operation ------------------------------------------------19 Timeout Settings----------------------------------------------------19 Maintenance ---------------------------------------------------------21 Cleaning ---------------------------------------------------------21 Storage ---------------------------------------------------------21 Troubleshooting ------------------------------------------------------22 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 27 - 05 - Product Overview United St ates /Canada/Ja pan Euro pe/ South Kore aChina United Ki ngdom Aust ra lia - 06 - LCD Display LED Strip Lights AC Outlets CIG Port Overload Protector AC Inlet DC Input Port Parallel Outlet - 07 - Package Content PHOENIX 500 Portable Power S tatio n AC P ower Cable Car C harge Cable User M anualSola r C harge Cable - 08 - LCD Display IconNameDescription Indicates the current battery level. As the PHOE- NIX charges, the ring will light up clockwise with the increasing percentage, and the endmost ring segment will fast flash. Once PHOENIX is fully charged, all the ring segments will light up and re- main solid. As the PHOENIX discharges, the ring will go out counterclockwise. When the battery lev- el drops below 10%, the last ring segment will slow Input Power Indicates the amount of power going int o PHOE- NIX. Output Power Indicates the amount of power going out of PHOE- NIX. Remaining Time Indicates the amount of time before PHOENIX is completely charged or discharged. When PHOE- NIX idles, the remaining time will show 99 hours. AC Outlet Status the AC Outlet(s). - 09 - IconNameDescription CIG Port Status SP…
Text truncated - open the document above for the full version.
Report No.: BL-SZ2280702-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China TEST REPORT Applicant: Guangzhou ZHIYUAN Electronics Co., Ltd. Address: ZLG Zhiyuan Electronics Building, No. 43 Sicheng Road, Tianhe District, Guangzhou, Guangdong Province Equipment Type: Wi-Fi Module Model Name: ZM602P2S31P Brand Name: ZLG Test Standard: GB/T 9410-2008 (refer section 3.1) Test Date: Jun. 10, 2022 Date of Issue: Aug. 18, 2022 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Mai Jintian Checked by: Tolan Tu Approved by: Wei Yanquan (Chief Engineer) _______________ _______________ _______________ Report No.: BL-SZ2280702-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Revision History Version Issue Date Revisions Rev. 01 Aug. 18, 2022 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................... 4 1.1 Test Laboratory ..................................................................................................................... 4 1.2 Test Location ......................................................................................................................... 4 2 PRODUCT INFORMATION ......................................................................................................... 5 2.1 Applicant Information ............................................................................................................ 5 2.2 Manufacturer Information ...................................................................................................... 5 2.3 Factory Information ............................................................................................................... 5 2.4 General Description for Equipment under Test (EUT) .......................................................... 5 2.5 Ancillary Equipment .............................................................................................................. 5 2.6 Technical Information ............................................................................................................ 5 3 SUMMARY OF TEST RESULTS ................................................................................................. 6 3.1 Test Standards ...................................................................................................................... 6 3.2 Test Verdict ........................................................................................................................... 6 3.3 Test Uncertainty .................................................................................................................... 6 4 GENERAL TEST CONFIGURATIONS ........................................................................................ 7 4.1 Test Condition ....................................................................................................................... 7 4.2 Test Equipment List .............................................................................................................. 7 4.3 Test Setup ............................................................................................................................. 8 ANNEX A TEST RESULTS ........................................................................................................... 10 A.1 Gain and Efficiency ............................................................................................................. 10 A.2 VSWR ................................................................................................................................. 11 A.3 Return Loss ......................................................................................................................... 12 A.4 Input Impedance ................................................................................................................. 13 ANNEX B RADIATION PATTERN ................................................................................................ 14 Report No.: BL-SZ2280702-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China ANNEX C TEST SETUP PHOTO ................................................................................................. 17 ANNEX D EUT PHOTO ................................................................................................................ 19 Report No.: BL-SZ2280702-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 4 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1 GENERAL INFORMATION 1.1 Test Laboratory Name Shenzhen BALUN Technology Co., Ltd. Address Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Phone Number +86 755 6685 0100 1.2 Test Location Name Shenzhen BALUN Technology Co., Ltd. Location Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 5 / 20…
Text truncated - open the document above for the full version.
RNGInternationalInc. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2022-08-23 Subject;RequestforConfidentiality FCCID:2ANPB-RPS5080AA ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription SWSECURITYDESCRIPTION PartsList Tuneup Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:jasonjiang Title:CTO
RNGInternationalInc. LetterofAuthorization Company:RNGInternationalInc. Address:5050SArchibaldAve,Ontario,California,91762,UnitedStates ProductName:Phoenix500PortablePowerStation ModelNumber(s):RPS5080AA-PCS ProductDescription:Phoenix500PortablePowerStation WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2022-08-23 Name:jasonjiang Title:CTO Company:RNGInternationalInc.
Code:AB-RF-05-b ExternalPhotograph Code:AB-RF-05-b Code:AB-RF-05-b Code:AB-RF-05-b
RG800 IC ID资料审核清单:产品序列号& Label label在样机上的具体位置: Label具体内容: SN码规则及格式
Code:AB-RF-05-b InternalPhotograph Code:AB-RF-05-b Code:AB-RF-05-b Code:AB-RF-05-b Code:AB-RF-05-b Code:AB-RF-05-b Code:AB-RF-05-b ANT Code:AB-RF-05-b
RFEXPOSUREEVALUATION FCCID:2ANPB-RPS5080AA AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnot required,portabletransmitterswithoutputpowergreaterthantheapplicable lowthresholdrequireSARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power (dBm) Distance (mm) Calculation results Limit Operating Mode 24022.012.01±13.0150.6203 BLE24401.691.69 ±1 2.6950.5803 24800.940.94±11.9450.4923 Result:NoStandaloneSARtestisrequired.
ReportNo.:18220WC20170501FCCID:2ANPB-RPS5080AAPage1of30 Code:AB-RF-05-b FCCTestReport ClientName:RNGInternationalInc. ClientAddress: 5050SArchibaldAve,Ontario,California, 91762,UnitedStates ProductName:Phoenix500PortablePowerStation ReportDate:Aug.23,2022 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC20170501FCCID:2ANPB-RPS5080AAPage2of30 Code:AB-RF-05-b Contents 1.GeneralInformation............................................................................................................................................6 1.1.ClientInformation....................................................................................................................................6 1.2.DescriptionofDevice(EUT)..................................................................................................................6 1.3.AuxiliaryEquipmentUsedDuringTest.................................................................................................7 1.4.DescriptionofTestConfiguration..........................................................................................................7 1.5.DescriptionOfTestSetup......................................................................................................................8 1.6.TestEquipmentList.................................................................................................................................9 1.7.MeasurementUncertainty....................................................................................................................10 1.8.DescriptionofTestFacility...................................................................................................................10 2.SummaryofTestResults.................................................................................................................................11 3.ConductedEmissionTest................................................................................................................................12 3.1.TestStandardandLimit........................................................................................................................12 3.2.TestSetup...............................................................................................................................................12 3.3.TestProcedure.......................................................................................................................................12 3.4.TestData.................................................................................................................................................12 4.RadiationSpuriousEmissionandBandEdge.............................................................................................15 4.1.TestStandardandLimit........................................................................................................................15 4.2.TestSetup...............................................................................................................................................15 4.3.TestProcedure.......................................................................................................................................16 4.4.TestData.................................................................................................................................................17 5.MaximumPeakOutputPowerTest...............................................................................................................25 5.1.TestStandardandLimit........................................................................................................................25 5.2.TestSetup...............................................................................................................................................25 5.3.TestProcedure.......................................................................................................................................25 5.4.TestData.................................................................................................................................................25 6.6DBOccupyBandwidthTest..........................................................................................................................26 6.1.TestStandardandLimit........................................................................................................................26 6.2.TestSetup...............................................................................................................................................26 6.3.TestProcedure.......................................................................................................................................26 6.4.TestData.................................................................................................................................................26 7.PowerSpectralDensityTest...........................................................................................................................27 7.1.TestStandardandLimit........................................................................................................................27 7.2.TestSetup...............................................................................................................................................27 7.3.TestProcedure.......................................................................................................................................27 7.4.TestData.................................................................................................................................................27 8.100kHzBandwidthofFrequencyBandEdgeRequirement......................................................................28 8.1.TestStandardandLimit........................................................................................................................28 ReportNo.:18220WC20170501FCCID:2ANP…
Text truncated - open the document above for the full version.
Page1of18 AppendixTestData ReportNo.:18220WC20170501TestSampleNo.:1-2-2 StartTestDate:2022.8.1FinishTestDate:2022.8.9 TestEngineer:Auditor: Temperature:26.3 °C RelativeHumidity:46% Pressure:1012hPa AppendixA:DTSBandwidth TestResult TestModeAntennaFrequency[MHz]DTSBW[MHz]FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.6842401.6562402.3400.5PASS 24400.6722439.6642440.3360.5PASS 24800.6762479.6442480.3200.5PASS Page2of18 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page3of18 Page4of18 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaFrequency[MHz]OCB[MHz]FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.03492401.49602402.5309------ 24401.03092439.49562440.5265------ 24801.03102479.49752480.5285------ Page5of18 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page6of18 Page7of18 AppendixC:Maximumconductedoutputpower TestResultPeak Test Mode AntennaFrequency[MHz] Conducted Peak Powert[dBm] Conducted Limit[dBm] EIRP[dBm] EIRP Limit[dBm] Verdict BLE_1MAnt1 24022.01≤302.01≤36PASS 24401.69≤301.69≤36PASS 24800.94≤300.94≤36PASS Page8of18 TestGraphsPeak BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page9of18 Page10of18 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz]Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-13.24≤8.00PASS 2440-13.5≤8.00PASS 2480-14.22≤8.00PASS Page11of18 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page12of18 Page13of18 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChNameFrequency[MHz]RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 Low24021.24-56.18≤-18.76PASS High24800.24-57.64≤-19.76PASS Page14of18 TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Page15of18 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict TestModeAntennaChannelFreqRangeRefLevelResultLimitVerdict Page16of18 AppendixG:DutyCycle TestResult TestModeAntennaFrequency[MHz] ONTime [ms] Period [ms] DutyCycle [%] DutyCycle Factor[dB] BLE_1MAnt1 24020.380.6360.322.20 24400.380.6360.322.20 24800.380.6360.322.20 Page17of18 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page18of18 ---End---
Code:AB-RF-05-b TestSetupPhotograph PhotoofConductedEmissionMeasurement PhotoofRadiationEmissionTest Code:AB-RF-05-b
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.30 mW |

BT-2 Bluetooth Module
Equipment Class
DTS - Digital Transmission System
Smart Shunt 300
Equipment Class
DTS - Digital Transmission System
SMART LITHIUM IRON PHOSPHATE BATTERY
Equipment Class
DTS - Digital Transmission System
Bluetooth Communication Module
Equipment Class
DTS - Digital Transmission System
Renogy ONE Core
Equipment Class
DTS - Digital Transmission System