FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dongguan SmartAction Technology Co.,Ltd/
  3. 2AOBQ-HIBYRS82

2AOBQ-HIBYRS82High Resolution Music Player

Dongguan SmartAction Technology Co.,Ltd

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 20, 2026
Application Purpose
Original Equipment
Equipment Note
High Resolution Music Player
Frequency Range
2412.00000000 - 2472.00000000
Company
Dongguan SmartAction Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 101 of 181 REPORT No.:SZ25090265W02 -6dB Bandwidth NVNT n40 2462MHz Ant1 MIMO -6dB Bandwidth NVNT n40 2462MHz Ant2 MIMO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 102 of 181 REPORT No.:SZ25090265W02 A.5. Conducted Spurious Emissions Condition Mode Frequency (MHz)AntennaMax Value (dBc)Limit (dBc) Verdict NVNT b SISO 2412 Ant1 -36.4 -20 Pass NVNT b SISO 2442 Ant1 -34.68 -20 Pass NVNT b SISO 2472 Ant1 -35.71 -20 Pass NVNT b SISO 2412 Ant2 -34.96 -20 Pass NVNT b SISO 2442 Ant2 -34.7 -20 Pass NVNT b SISO 2472 Ant2 -34.76 -20 Pass NVNT g SISO 2412 Ant1 -31.72 -20 Pass NVNT g SISO 2442 Ant1 -32.03 -20 Pass NVNT g SISO 2472 Ant1 -31.91 -20 Pass NVNT g SISO 2412 Ant2 -32.45 -20 Pass NVNT g SISO 2442 Ant2 -32.87 -20 Pass NVNT g SISO 2472 Ant2 -32.41 -20 Pass NVNT n20 SISO2412 Ant1 -31.28 -20 Pass NVNT n20 SISO2442 Ant1 -31.74 -20 Pass NVNT n20 SISO2472 Ant1 -32.24 -20 Pass NVNT n20 SISO2412 Ant2 -31.97 -20 Pass NVNT n20 SISO2442 Ant2 -31.49 -20 Pass NVNT n20 SISO2472 Ant2 -32.86 -20 Pass NVNT n40 SISO2422 Ant1 -28.12 -20 Pass NVNT n40 SISO2442 Ant1 -29.75 -20 Pass NVNT n40 SISO2462 Ant1 -28.93 -20 Pass NVNT n40 SISO2422 Ant2 -30.13 -20 Pass NVNT n40 SISO2442 Ant2 -30.34 -20 Pass NVNT n40 SISO2462 Ant2 -30.13 -20 Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 103 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT b 2412MHz Ant1 Ref SISO Tx. Spurious NVNT b 2412MHz Ant1 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 104 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT b 2442MHz Ant1 Ref SISO Tx. Spurious NVNT b 2442MHz Ant1 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 105 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT b 2472MHz Ant1 Ref SISO Tx. Spurious NVNT b 2472MHz Ant1 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 106 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT b 2412MHz Ant2 Ref SISO Tx. Spurious NVNT b 2412MHz Ant2 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 107 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT b 2442MHz Ant2 Ref SISO Tx. Spurious NVNT b 2442MHz Ant2 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 108 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT b 2472MHz Ant2 Ref SISO Tx. Spurious NVNT b 2472MHz Ant2 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 109 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT g 2412MHz Ant1 Ref SISO Tx. Spurious NVNT g 2412MHz Ant1 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 110 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT g 2442MHz Ant1 Ref SISO Tx. Spurious NVNT g 2442MHz Ant1 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 111 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT g 2472MHz Ant1 Ref SISO Tx. Spurious NVNT g 2472MHz Ant1 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 112 of 181 REPORT No.:SZ25090265W02 Tx. Spurious NVNT g 2412MHz Ant2 Ref SISO Tx. Spurious NVNT g 2412MHz Ant2 Emission SISO MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , …

Text truncated - open the document above for the full version.

Test Report

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 181 REPORT No.:SZ25090265W02 TEST REPORT APPLICANT : Dongguan SmartAction Technology Co.,Ltd. PRODUCT NAME : High Resolution Music Player MODEL NAME : HiBy RS8II BRAND NAME : HiBy FCC ID : 2AOBQ-HIBYRS82 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2025-09-18 TEST DATE : 2025-10-15 to 2025-12-09 ISSUE DATE : 2026-04-09 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 181 REPORT No.:SZ25090265W02 DIRECTORY 1. Summary of Test Result ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4 1.1. Testing Applied Standards ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5 1.2. Test Equipment List ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6 1.3. Measurement Uncertainty ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8 1.4. Testing Laboratory ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8 2. General Description ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 9 2.1. Information of Applicant and Manufacturer ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 9 2.2. Information of EUT ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 9 2.3. Channel List of EUT ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 11 2.4. Test Configuration of EUT ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 12 2.5. Test Conditions ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 12 2.6. Test Setup Layout Diagram ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 13 3. Test Results ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 16 3.1. Antenna Requirement ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 16 3.2. Duty Cycle of Test Signal ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 17 3.3. Maximum Peak and Average Conducted Output Power ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 18 3.4. 6 dB Bandwidth ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 19 3.5. Conducted Spurious Emissions and Band Edge ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 20 3.6. Power Spectral Density ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 21 3.7. Conducted Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 22 3.8. Restricted Frequency Bands ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 23 3.9. Radiated Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 24 Annex A Test Data and Result ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 26 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 181 REPORT No.:SZ25090265W02 Change History Version Date Reason for change 1.0 2026-04-09 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 181 REPORT No.:SZ25090265W02 1. Summary of Test Result No. Section Description Test Date Test EngineerResult Remark 1 15.203 Antenna Requirement N/A N/A PASS / 2 N/A Duty Cycle of Test Signal Oct. 17, 2025 Lin Haoyang PASS / 3 15.247(b) Maximum Peak Conducted Output Power Oct. 17, 2025 Lin Haoyang PASS / 4 15.247(b) Maximum Average Conducted Output Power Oct. 17, 2025 Lin Haoyang PASS / 5 15.247(a) Bandwidth Oct. 17, 2025 Lin Haoyang PASS / 6 15.247(d) Conducted Spurious Emission and Band Edge Oct. 17, 2025 Lin Haoyang PASS / 7 15.247(e) Power Spectral Density Oct. 17, 2025 Lin Haoyang PASS / 8 15.207 Conducted Emission N/A N/A Note1 N/A / 9 15.247(d) Restricted Frequency Bands Oct. 25, 2025 Gao Jianrou PASS / 10 15.209, 15.247(d) Radiated Emission Oct. 25, 2025 Gao Jianrou PASS / Note 1: Measurements to demonstrate compliance with the conducted limits are not required for devices which only employ battery power for operation and which do not operate from the AC power lines or contain provisions for operation while connected to the AC power lines. Note 2: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2020 and KDB558074 D01 v05r02. Note 3: Any additions, deviation, or exclusions from the method shall be noted in the “Remark”. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-…

Text truncated - open the document above for the full version.

Test Report

add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 东莞市松汇实业有限公司 99 规 格 承 认 书 SPECIFICATION FOR APPROVAL 编 号: 2025072901 File No. 版 本: 1.0 Revision 客 戶 CUSTOMER: ______________________________________ 客 戶 料 号 品 名 PART NAME: ______________________________________ 供 方 料 号 SUPPLIER NO: _____________________________________ 送样日期Date: 送样数量Q’TY: PCS 客户确认 CUSTOMER APPROVED BY APPROVAL CHIEF SUPERVISOR 供方确认 SUPPLIER SIGNATURE APPROVAL CHECK DESIGN sunny ZouJie LuoYi SH-RD-F04-A SL233P.300017.P01 CUSTOMER NO: ______________________________________ add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 承认书项目表 NO. 内 容 (Contents) 页 数 (Number of Page) 页 码 (Page Code) 1 承认书封面 (Spec Cover) 1 1 2 承认书项目表(Spec Item ) 1 2 3 工程成品图 (Drawing) 1 3 4 电性测试报告(Test Reports ) 1 4 5 S参数测试 (S Parameter ) 1 5 6 增益测试 (Gain Test ) 1 6 7 测试报告 1 7 8 9 10 - - - 11 - - - 12 - - - 3 add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 Electrical Properties Frequency 2.4~2.5GHz/5.15~5.85GHz Impedance 50 0hm Nominal V.S.W.R 1.92 : 1 Max Return Loss -10 dB Max Radiation Omni-directional Gain (Peak) 3.73dBi Cable Loss 2dB / m Max @ 2450 MHz Polarization Linear, Vertical Admitted Power 1 W Connector MHF3 代 Physical Properties Antenna Material MET Cable Type O.D. 0.81// L= 60mm Operating Temp. -10 ~ +80 ̊C Storage Temp. -10 ~ +80 ̊C Cable Colorblack 电 性 测 试 报 告 Test Reports add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 S 参 数 测 试 S Parameter Test Agilent E5071C add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 增 益 测 试 Gain Test

Test Report

add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 东莞市松汇实业有限公司 99 规 格 承 认 书 SPECIFICATION FOR APPROVAL 编 号: 2025 0 72902 File No. 版 本: 1.0 Revision 客 戶 CUSTOMER: ______________________________________ 客 戶 料 号 品 名 PART NAME: ______________________________________ 供 方 料 号 SUPPLIER NO: _____________________________________ 送样日期 Date: 送样数量Q’TY : PCS 客户确认 CUSTOMER APPROVED BY APPROVAL CHIEF SUPERVISOR 供方确认 SUPPLIER SIGNATURE APPROVAL CHECK DESIGN sunny ZouJie LuoYi SH-RD-F04-A SL233P.3000 18 .P01 CUSTOMER NO: ______________________________________ add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 承认书项目表 NO. 内 容 (Contents) 页 数 (Number of Page) 页 码 (Page Code) 1 承认书封面 (Spec Cover) 1 1 2 承认书项目表(Spec Item ) 1 2 3 工程成品图 (Drawing) 1 3 4 电性测试报告(Test Reports ) 1 4 5 S参数测试 (S Parameter ) 1 5 6 增益测试 (Gain Test ) 1 6 7 测试报告 1 7 8 9 10 - - - 11 - - - 12 - - - 3 add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 Electrical Properties Frequency 2.4~2.5GHz/5.15~5.85GHz Impedance 50 0hm Nominal V.S.W.R 1.92 : 1 Max Return Loss -10 dB Max Radiation Omni-directional Gain (Peak) 4.23dBi Cable Loss 2dB / m Max @ 2450 MHz Polarization Linear, Vertical Admitted Power 1 W Connector MHF3 代 Physical Properties Antenna MaterialFPC Cable Type O.D. 0.81// L= 40mm Operating Temp. -10 ~ +80 ̊C Storage Temp. -10 ~ +80 ̊C Cable Colorblack 电 性 测 试 报 告 Test Reports add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 S 参 数 测 试 S Parameter Test Agilent E5071C add:东莞市大朗镇佛新聚祥二路26号 电话:0769-82226176 传真:0769-82226175 增 益 测 试 Gain Test

RF Exposure Info

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ25090265S01 Page 1 of 48 TEST REPORT APPLICANT : Dongguan SmartAction Technology Co.,Ltd. PRODUCT NAME : High Resolution Music Player MODEL NAME : HiBy RS8II BRAND NAME : HiBy FCC ID : 2AOBQ-HIBYRS82 STANDARD(S) : FCC 47 CFR Part 2 (2.1093) IEEE 1528-2013 RECEIPT DATE : 2025-09-18 TEST DATE : 2025-10-22 to 2025-10-24 ISSUE DATE : 2026-04-08 Edited by: Pang Siyu (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ25090265S01 Page 2 of 48 DIRECTORY 1. Statement of Compliance·································································································· 5 2. Technical Information ········································································································ 6 2.1. Applicant and Manufacturer Information ····································································· 6 2.2. Equipment under Test (EUT) Description ···································································· 6 2.3. Environment of Test Site/Conditions ··········································································· 7 3. Specific Absorption Rate (SAR) ······················································································· 8 3.1. Introduction······················································································································ 8 3.2. SAR Definition ················································································································· 8 4. RF Exposure Limits ··········································································································· 9 4.1. Uncontrolled Environment ····························································································· 9 4.2. Controlled Environment ································································································· 9 5. Applied Reference Documents ······················································································ 10 6. SAR Measurement System ····························································································· 11 6.1. E-Field Probe ················································································································· 12 6.2. Data Acquisition Electronics (DAE) ············································································ 13 6.3. Robot ······························································································································ 13 6.4. Measurement Server ····································································································· 14 6.5. Light Beam Unit ············································································································· 14 6.6. Phantom ························································································································· 14 6.7. Device Holder ················································································································ 15 6.8. Data Storage and Evaluation ······················································································· 16 6.9. Test Equipment List ······································································································ 18 7. Tissue Simulating Liquids ······························································································ 19 8. SAR System Verification ································································································· 21 8.1. Purpose of System Performance Check ···································································· 21 8.2. System Setup ················································································································· 21 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ25090265S01 Page 3 of 48 8.3. Validation Results ········································································································· 22 9. EUT Testing Position ······································································································· 25 9.1. Body-worn Configurations ·························································································· 25 9.2. Hotspot Mode Exposure Position Conditions ·························································· 25 10. Measurement Procedures ······························································································· 27 10.1. Spatial Peak SAR Evaluation ······················································································· 28 10.2. Power Reference Measurement ·················································································· 28 10.3. Area Scan Procedures ····················································…

Text truncated - open the document above for the full version.

RF Exposure Info

Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2025.09.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D5250V2-SN: 1176 Antenna Parameters with Head TSL Impedance, transformed to feed point 51.07Ω+2.05jΩ Return Loss -32.818dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power,only a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm, because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2025.09.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D5600V2-SN: 1176 Antenna Parameters with Head TSL Impedance, transformed to feed point 50.89Ω-2.58jΩ Return Loss -31.355dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power,only a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm, because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2025.09.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D5750V2-SN: 1176 Antenna Parameters with Head TSL Impedance, transformed to feed point 50.962Ω+0.196jΩ Return Loss -40.247dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power,only a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm, because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL

RF Exposure Info

Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2025.09.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D2450V2-SN: 805 Antenna Parameters with Head TSL Impedance, transformed to feed point 48.132Ω-0.197jΩ Return Loss -34.362dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power,only a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm, because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL

Attestation Statements

Dongguan SmartAction Technology Co.,Ltd PHOENIX TESTLAB GmbH Date: 2026-01-29 Product Certification Department Koenigswinkel 10 32825 Blomberg Germany Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Dongguan SmartAction Technology Co.,Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Dongguan SmartAction Technology Co.,Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Type of Equipment subject to FCC Certification: High Resolution Music Player FCC ID: 2AOBQ-HIBYRS82 If you have any questions, please feel free to contact me Contact Person: Libin Zeng Position in the Company: Manager Date of Signature: 2026-01-29 ___________________________ Signatory (signature of the applicant)

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ25090265S01 Annex F DASY Calibration Certificate

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.:SZ25090265S01 Annex E Conducted Power Note: Conducted power unit: dBm The target power was recorded in the manufacturer's document. 2.4GHz WLAN ANT 12.4GHz WLAN ANT 22.4GHz WLAN ANT 1+2 CH 1241215.5416.5016.0098.30CH 1241215.4116.0016.0098.57CH 12412N/AN/AN/AN/A CH 7244215.6116.5016.0098.29CH 7244215.5316.5016.0098.29CH 72442N/AN/AN/AN/A CH 13247215.6916.5016.0098.29CH 13247215.7116.5016.0098.57CH 132472N/AN/AN/AN/A CH 1241215.4916.0016.0099.24CH 1241215.5816.5016.0099.15CH 12412N/AN/AN/AN/A CH 7244215.5116.5016.0099.24CH 7244215.4916.0016.0099.15CH 72442N/AN/AN/AN/A CH 13247215.4316.0016.0099.15CH 13247215.6016.5016.0099.15CH 132472N/AN/AN/AN/A CH 1241215.6016.5016.0099.67CH 1241215.7116.5016.0099.70CH 1241215.7516.5013.0099.70 CH 7244215.7516.5016.0099.67CH 7244215.5916.5016.0099.67CH 7244215.7616.5013.0099.70 CH 13247215.6316.5016.0099.67CH 13247215.6816.5016.0099.67CH 13247215.5616.5013.0099.67 CH 3242215.7816.5016.0099.70CH 3242216.0817.0016.0099.70CH 3242215.8516.5013.0099.67 CH 7244215.8116.5016.0099.67CH 7244215.8316.5016.0099.70CH 7244215.8216.5013.0099.70 CH 11246216.0517.0016.0099.70CH 11246216.4717.0016.0099.70CH 11246216.1317.0013.0099.67 5.2GHz WLAN ANT 15.2GHz WLAN ANT 25.2GHz WLAN ANT 1+2 CH 36518015.6316.5016.00100.00CH 36518014.4615.0016.00100.00CH 365180N/AN/AN/AN/A CH 44522016.1417.0016.00100.00CH 44522014.9615.5016.00100.00CH 445220N/AN/AN/AN/A CH 48524015.8916.5016.00100.00CH 48524015.3616.0016.00100.00CH 485240N/AN/AN/AN/A CH 36518015.6816.5016.00100.00CH 36518014.4215.0016.00100.00CH 36518015.0816.0013.00100.00 CH 44522016.0917.0016.00100.00CH 44522014.9515.5016.00100.00CH 44522015.5016.5013.00100.00 CH 48524015.8816.5016.00100.00CH 48524015.2716.0016.00100.00CH 48524015.4016.0013.00100.00 CH 38519016.4017.0016.00100.00CH 38519015.2816.0016.00100.00CH 38519015.6216.5013.00100.00 CH 46523016.5117.5016.00100.00CH 46523015.6316.5016.00100.00CH 46523015.9516.5013.00100.00 5.8GHz WLAN ANT 15.8 WLAN ANT 25.8 WLAN ANT 1+2 CH 149574515.5216.5016.00100.00CH 149574515.2416.0016.00100.00CH 1495745N/AN/AN/AN/A CH 157578515.2316.0016.00100.00CH 157578515.5216.5016.00100.00CH 1575785N…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Libin Zeng(Manager)
[email protected]Fax: +86 0769 23182216

Technical Contact

MusicTeckAndrew Huang
[email protected]

15 Jefferson Ave, Tenafly, NJ 07670 · Tenafly, New Jersey, 7670 · United States

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.47 GHz264.24 mW
Confidentiality
Long Term
Grant Notes
Output power is maximum peak conducted. <br> This device supports IEEE 802.11 b/g/n 20 and 40 MHz channel bandwidths. <br> This device has integrated DSS, DTS and NII transmitters certified under the same FCC ID. <br> SAR compliance for body-worn operating configurations is limited to the belt- clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 0.79 W/kg and 1.50 W/kg, respectively.

Other Applications from Dongguan SmartAction Technology Co.,Ltd

2AOBQ-HIBYM500

High Resolution Music Player

Aug 21, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2AOBQ-HIBYW4

BLUETOOTH AMPLIFIER

Apr 10, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
High resolution music player with WIFI and Bluetooth - FCC ID 2AOBQ-HIBYR8G2 - Dongguan SmartAction Technology Co.,Ltd
2AOBQ-HIBYR8G2

High resolution music player with WIFI and Bluetooth

Feb 20, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
High Resolution Music Player with BT, WIFI - FCC ID 2AOBQ-HIBYR3G2 - Dongguan SmartAction Technology Co.,Ltd
2AOBQ-HIBYR3G2

High Resolution Music Player with BT, WIFI

May 17, 2023

Equipment Class

DTS - Digital Transmission System