2 A O E A - E L S 1 0 0 Replacing/Installing Battery: Counter Clockwise with a small twist open the EZW1204 to expose circuit board, LED, and battery holder. Install the 1 x 23A battery. Replace the cover with a small clockwise twist to snap it into place. Pairing the ELS100 Leak Sensor with the Bulldog-JW Control Module: Including or Pairing the ELS100 to the Bulldog-JW Controller: Multiple Leak Sensors can be paired/included into the 433MHz wireless network, one at a time, in a simple 3 step process: 1.Put the Bulldog-JW Controller into pairing mode (single button click, see Bulldog-JW Quick Start Guide) 2.Activate the Leak Sensor by getting it wet for 2 seconds (wet paper towel or cloth) 3.Test in location by getting leak sensor wet and confirming Control Module Relay Activation/Valve Close Leak Sensors can not be excluded (un-paired) individually. All leak sensors will be excluded from the Control Module when exclusion process is initiated. (see Bulldog-JW Control Module Leak Sensor Exclusion Process – hold pairing button for 5+ seconds)
C5266091_X8_Ed.1 1/1 LetterofAuthorization EcoNetControlsInc. Company:EcoNetControlsInc. Address:1100SuttonDr.,Unit3Burlington,OntarioCanada ProductName:433MHzwaterleaksensor ModelNumber:ELS100 FCCIdentifier:2AOEA-ELS100 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:BlakeAllenDate:2020-05-26 Title:CEO Signatureofapplicant:
C5266091_X10_Ed.1 1/1 EcoNetControlsInc. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2020-05-26 Subject:RequestforConfidentiality FCCID:2AOEA-ELS100 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:BlakeAllen Title:CEO
FCC ID: 2AOEA-ELS100
Antenna FCC ID: 2AOEA-ELS100 TX-118S-4 V2 TX-118S-4 V2
Page1of35 FCCTESTREPORT FCCID:2AOEA-ELS100 Product:433MHzwaterleaksensor ModelName:ELS100 Brand:EcoNetControls ReportNo.:PTC20050901301E-FC01 Preparedfor EcoNetControlsInc. 1100SuttonDr.,Unit3Burlington,OntarioCanada Preparedby PreciseTesting&CertificationCo.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC20050901301E-FC01 Page2of35 1TESTRESULTCERTIFICATION Applicant’sname:EcoNetControlsInc. Address:1100SuttonDr.,Unit3Burlington,OntarioCanada Manufacture'sname:NIE-TECHCO.,LTD. Address: Room101No.2FourRoad,LudipuIndustrial,HumenTown,Dongguancity, China Productname:433MHzwaterleaksensor Modelname:ELS100 Standards:FCCCFR47Part15Section15.231 Testprocedure:ANSIC63.10:2013 TestDate:May15,2020toJune05,2020 DateofIssue:June05,2020 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,thisdocumentmaybe alteredorrevisedbyPTC,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: LeoYang/Engineer TechnicalManager: ChrisDu/Manager ReportNo.:PTC20050901301E-FC01 Page3of35 Contents Page 1TESTRESULTCERTIFICATION................................................................................................................................2 2TESTSUMMARY...........................................................................................................................................................5 3GENERALINFORMATION..........................................................................................................................................6 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................6 3.2TESTMETHODOLOGY..........................................................................................................................................7 3.3TESTSITE.............................................................................................................................................................8 4EQUIPMENTDURINGTEST.......................................................................................................................................9 4.1EQUIPMENTSLIST................................................................................................................................................9 4.2MEASUREMENTUNCERTAINTY..........................................................................................................................10 4.3DESCRIPTIONOFSUPPORTUNITS....................................................................................................................11 5CONDUCTEDEMISSION...........................................................................................................................................12 5.1E.U.T.OPERATION............................................................................................................................................12 5.2EUTSETUP........................................................................................................................................................12 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION)..................................................................................13 5.4MEASUREMENTPROCEDURE............................................................................................................................13 5.5CONDUCTEDEMISSIONLIMIT............................................................................................................................13 5.6MEASUREMENTDESCRIPTION...........................................................................................................................13 5.7CONDUCTEDEMISSIONTESTRESULT..............................................................................................................13 6RADIATEDSPURIOUSEMISSIONS.......................................................................................................................14 6.1EUTOPERATION...............................................................................................................................................16 6.2TESTSETUP.......................................................................................................................................................17 6.3SPECTRUMANALYZERSETUP...........................................................................................................................18 6.4TESTPROCEDURE.............................................................................................................................................19 6.5SUMMARYOFTESTRESULTS...........................................................................................................................20 7OCCUPIEDBANDWIDTH..........................................................................................................................................24 7.1APPLICABLESTANDARD.....................................................................................................................................24 7.2CONFORMANCELIMIT........................................................................................................................................24 7.3TESTPROCEDURE.............................................................................................................................................24 7.4TESTRESULT.....................................................................................................................................................25 8TRANSMISSIONREQUIREMENT............................................................................................................................26 ReportNo.:PTC20050901301E-FC01 Page4of35 8.1APPLICABLESTAND…
Text truncated - open the document above for the full version.
Radiated Spurious Emissions From 30MHz-1000MHz Test frequency from 1GHz-5GHz FCC ID: 2AOEA-ELS100
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Control Module
Equipment Class