FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhongshan Transtek Electronics Co., Ltd/
  3. 2AOJNGBF-2008

2AOJNGBF-2008Body Fat Analyzer

Zhongshan Transtek Electronics Co., Ltd
Body Fat Analyzer - FCC ID 2AOJNGBF-2008 - Zhongshan Transtek Electronics Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 24, 2020
Application Purpose
Original Equipment
Date of Application
Nov 24, 2020
Equipment Note
Body Fat Analyzer
Frequency Range
2412.00000000 - 2462.00000000
Company
Zhongshan Transtek Electronics Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

version:1.0 User Manual Body Fat Analyzer GBF-2008-BF Please do read the user manual carefully and thoroughly so as t o ensure the safe usage of this product, and keep the manual well for fu rther reference in case you have problems.Thank you very much for selecting the Transtek Body Fat Analyze r GBF-2008-BF. TEL:86-760-88282982 www.transtek.cn ZHONGSHAN TRANSTEK ELECTRONICS CO., LTD No.23,Jin'anRoad,Minzhong, Zhongshan, 528441, Guangdong,China  Table of Contents Table of Contents Safety Information Safety and Usage InformationYour Scale and Its EnvironmentEfficient Use of Your Scale Overview Device ComponentsListLED Display Initial Start-Up General InstructionsInsert the BatteriesInstall APP and Pair-Up Start Measuring Select Measurement UnitDaily MeasurementHeart Rate MeasurementSmall Items Measurement Manage Your Health Data Transmission Troubleshooting Error PromptWhen Measuring ...When Data Transmitting... SpecificationsMaintenanceWarrantyFCC RegulationsAppendix WarningEMC Guidance 233445 66789910 11 121214151616171818 ............................................................... ................................ ............................................................... ................................... ............................................................... .................................................. ............................................................... ............................................................... ............ ............................................................... .................................................. ............................................................... ........................................ ............................................................... ................................................... ............................................................... .................................................... ............................................................... .............................................................. ............................................................... .................................................. ............................................................... ............................................................... ... ............................................................... ............................................................ ............................................................... ......................................... ............................................................... ............................................................... ........ ............................................................... ......................................................... ............................................................... ............................................ ............................................................... ............................................................... ............................................................... .................................................... ............................................................... ......................................... ............................................................... ........................................ ............................................................... ......................................... ............................................................... .......................................................... ............................................................... ............................................................... ...   Safety Information Safety Information The Transtek Body Fat Analyzer measures weight and uses bio-ele ctrical impedance analysis(BIA) technology to estimate body fat and heart rate in generally healthy children 10-17 years old and healthy adults. It is intended for use in the domestic setting only. The warning signs and symbols are essential to ensure your corr ect and safe use of this product and protect you and others from injury. Please kin dly find the meanings of the warning signs and symbols, which you may encounter in the label and user manual, as follows: Safety and Usage Information CAUTION Symbol for “THE OPERATION GUIDE MUST BE READ” Symbol for “MANUFACTURER” Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice” Symbol for “TYPE BF APPLIED PARTS” The Bluetooth Combination MarkSymbol for “SERIAL NUMBER” Symbol for “DIRECT CURRENT” The Body Fat Analyzer GBF-2008-BF offers you a seamless way to manage your health. Please be aware that this device is designed for adults’ self-m easuring and self-monitoring body fat level. Any information provided by this device is in no way meant to treat, cure or prevent any disease or illness from happening. This device should not be u sed by anyone who is acutely or chronically ill, suffering from a disease or taking medications that affect your water levels. The accuracy of readings for these patients has not been verified. Specific medical advice should be obtained from a physician. Before diet and exercise, you must first find a professional me dical guide. The body fat analyzer is equipped with data transmission functi on. It may emit electromagnetic energy so as to perform its intended function. Nearby portable and mobile RF communications equipment can affect the performance of the device . Portable and mobile RF communications equipment can affect the measuring accuracy of the body fat analyzer. Kindly note that the use of accessories, transducers or cables other than those specified, with the exception of transducers and cables sold by the manufacture r as replacement parts for internal components, may result


Text truncated - open the document above for the full version.

Cover Letter(s)

ZhongshanTranstekElectronicsCo.,Ltd Date:11/05/2020 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:FCCID:2AOJNGBF-2008 Towhomitmayconcern: We,theundersigned,herebyauthorizeSGS-CSTCStandardsTechnicalServicesCo.,Ltd.(SGS) GuangzhoubranchandKobeJianinSGS-CSTCStandardsTechnicalServicesCo.,Ltd.(SGS) Guangzhoubranchtoactonourbehalfinallmannersrelatingtoapplicationforequipmentauthorization withrespecttotheFCCIDabove,includingsigningofalldocumentsrelatingtothesematters.Anyandall actscarriedoutbytheagentonourbehalfshallhavethesameeffectasactsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits,thatincludes FCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Whereouragentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatallresponsibility forcomplyingwiththetermsandconditionsforCertification,asspecifiedbySGSNorthAmerica,Inc.,still resideswithZhongshanTranstekElectronicsCo.,Ltd. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. Name (Printed) :TeaDuTitle:Healthresearchanddevelopment departmentdirector Signature: OnbehalfofCompany:ZhongshanTranstekElectronicsCo.,Ltd

Cover Letter(s)

SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates ApplicantDeclaration ApplicantLegalBusinessName ZhongshanTranstekElectronicsCo.,Ltd Address No.23,Jin'anRoad,MinzhongZhongshan,-,Guangdong,,China GranteeCode 2AOJN FCCID 2AOJNGBF-2008 AuthorizedContactName TeaDu ContactEmail [email protected] ContactPhone 13823906030 I,theundersigned,certifythatIamanauthorizedsignatoryfortheApplicantandthereforedeclare; a)inaccordancewith47CFR2.911(d),allofthestatementshereinandtheexhibitsattachedheretoaretrueandcorrecttothebestofmy knowledgeandbelief. b)inacceptingaGrantofEquipmentAuthorizationissuedbyaTCB,undertheauthorityoftheFCC,asaresultoftherepresentationsmadein thisapplication,theApplicantisresponsiblefor: (1)labelingtheequipmentwiththeexactFCCIDasspecifiedinthisapplication, (2)compliancestatementlabelingpursuanttotheapplicablerules, (3)complianceoftheequipmentwiththeapplicabletechnicalrules, c)iftheApplicantisnottheactualmanufactureroftheequipment,appropriatearrangementshavebeenmadewiththemanufacturertoensure thatproductionunitsofthisequipmentwillcontinuetocomplywiththeFCC’stechnicalrequirements. d)inaccordancewith47CFR2.909andKDB394321,theApplicanthasread,understoodandagreestoacceptthattheyaretheresponsible partyandagreetoabidebytheirresponsibilitiesasspecifiedunder47CFR2.909andKDB394321. e)inaccordancewithISO17065,FCCKDB641163,FCCKDB610077,KDB394321andRSP-100,theApplicanthasread,understood,accepts andagreestoabidebythepostmarketsurveillancerequirements. (1)theApplicantunderstands,acceptsandagreesthatasamplemayberequestedforsurveillancetesting. (2)theApplicantshallmakeprovisionstoalwayshaveaproductionsampleavailableuponrequestbySGS,FCCand/orISED. (3)theApplicantshall,uponrequestbySGS,attheApplicant’sexpense,provideaproductionsampleoftherequestedproducttoSGS, FCCand/orISEDasinstructed.Thesampleshallincludeallsupportdevices,cables,software,accessoriesorotherhardwareor softwarerequiredforevaluation,review,certificationandauditsurveillanceofproductscertifiedbySGS. f)neithertheApplicantnoranypartytotheapplicationissubjecttoadenialofFederalbenefits,thatincludesFCCbenefits,pursuanttoSection 5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862becauseofaconvictionforpossessionordistributionofacontrolledsubstance.See 47CFR1.2002(b)forthedefinitionofa“party”forthesepurposes. g)theApplicanthasread,understood,acceptsandagreestoabidebytheSGSNorthAmerica,Inc.(TCB)termsandconditions. LinktoCFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 LinktoKDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm LinktoRSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html ApplicantSignature:Date:11/05/2020 PrintName:TeaDu Title:Healthresearchanddevelopmentdepartmentdirector *NOTE:ThisdeclarationcannotbesignedbyanAgent,itshallbesignedbyanauthorizedpersonlistedintheFCCdatabase ApplicantDeclaration Rev:0.0

Cover Letter(s)

ZhongshanTranstekElectronicsCo.,Ltd To:SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia UnitedStates From:ZhongshanTranstekElectronicsCo.,Ltd No.23,Jin'anRoad,Minzhong Zhongshan,,Guangdong,,-,China Regarding:ConfidentialityRequestregardingapplicationforFCCID:2AOJNGBF-2008 LONGTERMCONFIDENTIALITY Pursuantto47CFRSection0.459and0.457ofthecommission’srules,theapplicantherebyrequest confidentialtreatmentofthedocumentslistedbelow,associatedwiththecertificationapplication referencedabove. Schematic(s) BlockDiagrams OperationalDescriptions Thedocumentsabovecontainproprietaryinformationnotreleasedtothepublic.Publicdisclosureofthis informationmayproveharmfultothebusinessoftheapplicant. Sincerely, Name(Printed):TeaDuTitle:Healthresearchanddevelopment departmentdirector Signature: OnbehalfofCompany:ZhongshanTranstekElectronicsCo.,Ltd

External Photos

External photo model: GBF-2008-BF model: GBF-2008-BF1

ID Label/Location Info

SN: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Body Fat Analyzer Model: GBF-2008-BF1 Capacity: 180Kg Devision: 0.05Kg Power Supply: 4XAAA 6V IP Classsificaiton: IP21 FCC ID:2AOJNGBF-2008 ZHONGSHAN TRANSTEK ELECTRONICS CO.,LTD 23, Jin'an Road, Minzhong, Zhongshan, 528441, Guangdong, China 2020-xx SN: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Body Fat Analyzer Model: GBF-2008-BF1 Capacity: 180Kg Devision: 0.05Kg Power Supply: 4XAAA 6V IP Classsificaiton: IP21 FCC ID:2AOJNGBF-2008 ZHONGSHAN TRANSTEK ELECTRONICS CO.,LTD 23, Jin'an Road, Minzhong, Zhongshan, 528441, Guangdong, China 2020-xx

Internal Photos

Internal photo RF ANT

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511503 Page: 1 of 9 FCC ID: 2AOJNGBF-2008 Kobe Jian EMC Laboratory Manager RF EXPOSURE EVALUATION REPORT Application No.: GZEM2009015115CR Applicant: Zhongshan Transtek Electronics Co., Ltd Address of Applicant: No.23, Jin'an Road, Minzhong, Zhongshan, Guangdong, China Manufacturer: Zhongshan Transtek Electronics Co., Ltd Address of Manufacturer: No.23, Jin'an Road, Minzhong, Zhongshan, Guangdong, China Factory: Zhongshan Transtek Electronics Co., Ltd Address of Factory: No.23, Jin'an Road, Minzhong, Zhongshan, Guangdong, China Equipment Under Test (EUT): FCC ID: 2AOJNGBF-2008 EUT Name: Body Fat Analyzer Model No.: GBF-2008-BF, GBF-2008-BF1 € € €€ € Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Standard(s): 47 CFR Part 1.1307, Part 2.1093, KDB 447498 Date of Receipt: 2020-09-15 Date of Test: 2020-09-23 to 2020-11-23 Date of Issue: 2020-11-24 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511503 Page: 2 of 9 Revision Record Version Chapter Date Modifier Remark 01 2020-11-24 Original Authorized for issue by: Tested By 2020-09-23 to 2020-11-23 Lily_Kuang /Project Engineer Date Checked By 2020-11-24 Ricky_Liu /Reviewer Date SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511503 Page: 3 of 9 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result RF Exposure 47 CFR Part 1.1307, Part 2.1093, KDB 447498 CFR 47 Part 2.1093 CFR 47 Part 2.1093 Pass € Declaration of EUT Family Grouping: Model No.: GBF-2008-BF, GBF-2008-BF1 According to the declaration from the applicant, the electrical circuit design, layout, components used and internal wiring were identical for all models, with only difference on the appearance. Therefore only one model GBF-2008-BF was tested in this report. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511503 Page: 4 of 9 3 Contents Page 1 Cover Page .............................................................................................................................................. 1 2 Test Summary ........................................................................................................................................ 3 3 Contents ................................................................................................................................................. 4 4 General Information ............................................................................................................................... 5 4.1 Details of E.U.T................................................................................................................................ 5 4.2 Description of Support Units............................................................................................................. 5 4.3 Test Location ................................................................................................................................... 5 4.4 Test Facility ..................................................................................................................................... 6 4.5 Deviation from Standards ................................................................................................................. 7 4.6 Abnormalities from Standard Conditions .......................................................................................... 7 5 Radio Spectrum Technical Requirement .............................................................................................. 8 5.1 RF Exposure.................................................................................................................................... 8 5.1.1 Test Requirement: ....................................................................................................................... 8 5.1.2 Conclusion .................................................................................................................................. 8 6 Photographs ........................................................................................................................................... 9 6.1 EUT Constructional Details .............................................................................................................. 9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511503 Page: 5 of 9 4 General Information 4.1 Details of E.U.T. Power Supply: DC 6.0V =4 x DC 1.5V size of "AAA" batteries Antenna Gain: -1 dBi declared by applicant Antenna Type: PCB antenna for antenna 1 Hardware Version: LS1200_V1.2 Firmware Version: V1.00 S/N: 20200826 Test Software Version: QCOM_V1.6 Power setting level -10 dBm can not be changed by user For Wi-Fi Channel Spacing: 5MHz Modulation Type: 802.11b: DSSS (CCK, DQPSK, DBPSK) Number of Channels: 802.11b(HT20):11 Operation Frequency: 802.11b(HT20): 2412MHz to 2462MHz For BT Channel Spacing: 2MHz Modulation Type: GFSK Number of Channels: 40 Operation Frequency: 2402MHz to 2480MHz BT Version V 5.0 for BLE_1M only 4.2 Description of Support Units The EUT has been tested as an independent unit. 4.3 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555 Fax: +86 20 82075059 No tests were sub-contracted. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511503 Page: 6 of 9 4.4 Test Facility The test facility is recognized, certified, or accredited by the following organizations: ïŹ NVLAP (Lab Code: 200611-0) S


Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511502 Page: 1 of 72 FCC ID: 2AOJNGBF-2008 Kobe Jian EMC Laboratory Manager TEST REPORT Application No.: GZEM2009015115CR Applicant: Zhongshan Transtek Electronics Co., Ltd Address of Applicant: No.23, Jin'an Road, Minzhong, Zhongshan, Guangdong, China Manufacturer: Zhongshan Transtek Electronics Co., Ltd Address of Manufacturer: No.23, Jin'an Road, Minzhong, Zhongshan, Guangdong, China Factory: Zhongshan Transtek Electronics Co., Ltd Address of Factory: No.23, Jin'an Road, Minzhong, Zhongshan, Guangdong, China Equipment Under Test (EUT): FCC ID: 2AOJNGBF-2008 EUT Name: Body Fat Analyzer Model No.: GBF-2008-BF, GBF-2008-BF1 € € Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Standard(s): 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2020-09-15 Date of Test: 2020-09-23 to 2020-11-23 Date of Issue: 2020-11-24 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511502 Page: 2 of 72 Revision Record Version Chapter Date Modifier Remark 01 2020-11-24 Original Authorized for issue by: Tested By 2020-09-23 to 2020-11-23 Lily_Kuang /Project Engineer Date Checked By 2020-11-24 Ricky_Liu /Reviewer Date SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511502 Page: 3 of 72 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(c) Pass N/A: Not applicable Radio Spectrum Matter Part Item Standard Method Requirement Result Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass € Declaration of EUT Family Grouping: Model No.: GBF-2008-BF, GBF-2008-BF1 According to the declaration from the applicant, the electrical circuit design, layout, components used and internal wiring were identical for all models, with only difference on the appearance. Therefore only one model GBF-2008-BF was tested in this report. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZEM200901511502 Page: 4 of 72 3 Contents Page 1 Cover Page .............................................................................................................................................. 1 2 Test Summary ........................................................................................................................................ 3 3 Contents ................................................................................................................................................. 4 4 General Information ............................................................................................................................... 6 4.1 Details of E.U.T................................................................................................................................ 6 4.2 Description of Support Units............................................................................................................. 6 4.3 Measurement Uncertainty ................................................................................................................ 7 4.4 Test Location ................................................................................................................................... 7 4.5 Test Facility ..................................................................................................................................... 8 4.6 Deviation from Standards ................................................................................................................. 9 4.7 Abnormalities from Standard Conditions .......................................................................................... 9 5 Equipment List ..................................................................................................................................... 10 6 Radio Spectrum Technical Requirement ............................................................................................ 13 6.1 Antenna Requirement .................................................................................................................... 13 6.1.1 Test Requirement: ..................................................................................................................... 13 6.1.2 Conclusion ................................................................................................................................ 13 7 Radio Spectrum Matter Test Results................................................................................................... 14 7.1 Minimum 6dB Bandwidth ............................................................................................................... 14 7.1.1 E.U.T. Operation........................................................


Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup Photo 1.1 RF test Setup 1.2 Radiated Emissions which fall in the restricted bands & Radiated Spurious Emissions Test Setup

Contact Information

Applicant

Tea Du
[email protected]13823906030Fax: 076085339231

Technical Contact

SGS-CSTC Standards Technical Services Co., LtdKobe Jian
[email protected]86-20-82155314

198 KEZHU Road, Scientech Park, Guangzhou Economic · Guangzhou · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., LtdKobe Jian
[email protected]86-20-82155314

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd.Bonnie Liao
[email protected]020-8215-5379

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz150.00 ”W
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. Device is an 802.11b device and enabled for 2.4GHz band as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of less than 5 mm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz bandwidth modes.

Other Applications from Zhongshan Transtek Electronics Co., Ltd

Body Scale - FCC ID 2AOJNGBS-2109 - Zhongshan Transtek Electronics Co., Ltd
2AOJNGBS-2109

Body Scale

Sep 22, 2022

Equipment Class

DTS - Digital Transmission System
Kitchen Scale - FCC ID 2AOJNGKS-2156-B - Zhongshan Transtek Electronics Co., Ltd
2AOJNGKS-2156-B

Kitchen Scale

Aug 14, 2022

Equipment Class

DTS - Digital Transmission System