FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Remote Tech LLC/
  3. 2AOKM-HD440

2AOKM-HD440Keyless Transmitter

Remote Tech LLC
Keyless Transmitter - FCC ID 2AOKM-HD440 - Remote Tech LLC
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 18, 2023
Application Purpose
Original Equipment
Date of Application
May 18, 2023
Equipment Note
Keyless Transmitter
Frequency Range
308.00000000 - 308.00000000
Company
Remote Tech LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PANIC When pre ss the PANIC but ton, the veh icle will star t sounding the horn and flushing the hazdard lamp until press any buttons on transmitter. FCC COMPLIANCE STATEMENT: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. IC WARNING: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1)This device may not cause interference. (2)This device must accept any interference, including interference that may cause undesired operation of the device. ADVERTENCIA IC Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS)d'Innovation,Sciences et Développement économique Canada. Le fonctionnement est soumis auxdeux conditions suivantes : (1)Cet appareil ne doit pas causer d'interférences. (2)Cet appareil doit accepter toutes les interférences, y compris celles susceptibles deprovoquer unfonctionnement indésirable de l'appareil. User’s Manual Keyless Transmitter FCC ID: 2AOKM-HD440 IC: 24223-HD440 MODEL: RT-SOXA01 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. This remote has lock,unlock,start ,panic,trunk buttons,you can open or close the vehicle with the remote transmitter. LOCK When you press the LOCK button, the vehicle doors will lock. If the door is not close, can not lock the door, also key in the ignition switch also can not lock the doors. UNLOCK When you press the UNLOCK button, you can open the all doors.if the key is in the ignition switch, can not unlock the doors. START When you press 2 times start button, you can start the car. Trunk When press the TRUNK buttons,open the trunk. It can not close the trunk using this transmitter.

Attestation Statements

Remote Tech LLC Covered Equipment Certification Attestation Letter DATE Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AOKM-HD440 Rem ote Tech LLC (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Remote Tech LLC (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Si gned: Printed name: John Strong Title: Manager Company Name: Remote Tech LLC Date: 5/8/2023

Attestation Statements

Remote Tech LLC * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter DATE TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2AOKM-HD440 FRN of applicant: 0027073436 Per section 2.911(d)(7) of the FCC rules, [Remote Tech LLC] (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Remote Tech LLC FCC Registration Number (FRN): 0027073436 Physical U.S. Company Address: 310 ALDER RD, DOVER DE 19904 USA Contact Person: John Strong Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: John Strong Title: Manager Company Name: Remote Tech LLC Date: 5/8/2023 Agent Signed (if different from Applicant): Signed: Printed name: Click here to enter text. Title: Click here to enter text. Company Name: Click here to enter text. Date: Click here to enter a date.

Cover Letter(s)

Remote Tech LLC DATE:2023-5-12 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act asAgent On our behalf, I appoint Jia nyan Testing Group Shenzhen Co., Ltd.; No.101, Building 8, Innovation Wisdom Port, N o.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China., to act as our agent in the preparation of this application for equipment certification. I certify t hat submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or ma rketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with t his application. For instances where our authorized agent signs the application for certification on our behalf, I a cknowledge that all responsibility for complying with the terms and conditions for certification, st ill resides with Remote Tech LLC /310 ALDER RD, DOVER DE 19904 USA Dated this 2023-5-12 By : John Strong Signature Printed Title: On behalf of : Remote Tech LLC Telephone: 302-336-8136

Cover Letter(s)

Remote Tech LLC DATE :2023-5-12 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AOKM-HD440 Product Name: Keyless Transmitter Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: •Schematics •Block diagram •Operation description •BOM Thes e materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 2023-5-12 By: John Strong Signature Printed Title: On behalf of : Remote Tech LLC Telephone: 302-336-8136

External Photos

JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 1 of 3 EUT External Photos JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 3 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 3 ------End------

ID Label/Location Info

FCC ID:2AOKM-HD440 IC:24223-HD440 MODEL:RT-SOXA01 PN:RT-440HA

Internal Photos

JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 1 of 3 EUT Internal Photos JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 3 JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 3 ------End------

RF Exposure Info

JianYan Testing Group Shenzhen Co., Ltd. Report No.: JYTSZ-R12-2300567 This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in above the application standard version. Test results reported herein relate only to the item(s) tested. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. Cover Page RF Exposure Evaluation Report Applicant: Remote Tech LLC Address of Applicant: 310 ALDER RD, DOVER DE 19904 USA Equipment Under Test (EUT) Product Name: Keyless Transmitter Model No.: RT-SOXA01 FCC ID: 2AOKM-HD440 Applicable standards: KDB 447498 D04 Interim General RF Exposure Guidance v01 Date of sample receipt: 24 Apr., 2023 Date of Test: 25 Apr., to 28 Apr., 2023 Date of report issue: 19 May, 2023 Test Result: PASS Tested by: Date: 19 May, 2023 Test Engineer Reviewed by: Date: 19 May, 2023 Project Engineer Approved by: Date: 19 May, 2023 Manager Report No.: JYTSZ-R12-2300567 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-187-C Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 6 Version 1 Version No. Date Description 00 04 May, 2023 Original 01 19 May, 2023 Update page 6 Report No.: JYTSZ-R12-2300567 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-187-C Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 6 Contents 2 Page Cover Page ............................................................................................................................................................. 1 Version ........................................................................................................................................................... 2 1 Contents ......................................................................................................................................................... 3 2 General Information ...................................................................................................................................... 4 3 Client Information ................................................................................................................................... 4 3.1 General Description of E.U.T. ................................................................................................................ 4 3.2 Operating Modes .................................................................................................................................... 5 3.3 Additions to, Deviations, or Exclusions from the Method ....................................................................... 5 3.4 Laboratory Facility .................................................................................................................................. 5 3.5 Laboratory Location ................................................................................................................................ 5 3.6 Technical Requirements Specification ....................................................................................................... 6 4 Limits ...................................................................................................................................................... 6 4.1 Result ..................................................................................................................................................... 6 4.2 Conclusion .............................................................................................................................................. 6 4.3 Report No.: JYTSZ-R12-2300567 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-187-C Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 4 of 6 General Information 3 Client Information 3.1 Applicant: Remote Tech LLC Address: 310 ALDER RD, DOVER DE 19904 USA Manufacturer: Remote Tech LLC Address: 310 ALDER RD, DOVER DE 19904 USA General Description of E.U.T. 3.2 Product Name: Keyless Transmitter Model No.: RT-SOXA01 Operation Frequency: 308 MHz Modulation technology: FSK Antenna Type: PCB Antenna Antenna gain: -5 dBi Power Supply: DC 3V (CR2032 battery) Test Sample Condition: The test samples were provided in good working order with no visible defects. Report No.: JYTSZ-R12-2300567 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-187-C Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 5 of 6 Operating Modes 3.3 Operating mode Detail description Tx mode Keep the EUT in continuously transmitting mode Additions to, Deviations, or Exclusions from the Method 3.4 No Laboratory Facility 3.5 The test facility is recognized, certified, or accredited by the following organizations:  FCC - Designation No.: CN1211 JianYan Testing Group Shenzhen Co., Ltd. has bee…

Text truncated - open the document above for the full version.

Test Report

JianYan Testing Group Shenzhen Co., Ltd. Report No.: JYTSZ-R12-2300566 This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in above the application standard version. Test results reported herein relate only to the item(s) tested. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. Cover Page FCC RF Test Report Applicant: Remote Tech LLC Address of Applicant: 310 ALDER RD, DOVER DE 19904 USA Equipment Under Test (EUT) Product Name: Keyless Transmitter Model No.: RT-SOXA01 FCC ID: 2AOKM-HD440 Applicable Standards: FCC CFR Title 47 Part 15C (§15.231) Date of Sample Receipt: 24 Apr., 2023 Date of Test: 25 Apr., to 28 Apr., 2023 Date of Report Issue: 04 May, 2023 Test Result: PASS Tested by: Date: 04 May, 2023 Test Engineer Reviewed by: Date: 04 May, 2023 Project Engineer Approved by: Date: 04 May, 2023 Manager Report No.: JYTSZ-R12-2300566 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-155-C Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 18 Version 1 Version No. Date Description 00 04 May, 2023 Original Report No.: JYTSZ-R12-2300566 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-155-C Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 18 Contents 2 Page Cover Page ............................................................................................................................................................. 1 Version ........................................................................................................................................................... 2 1 Contents ......................................................................................................................................................... 3 2 General Information ...................................................................................................................................... 4 3 Client Information ................................................................................................................................... 4 3.1 General Description of E.U.T. ................................................................................................................ 4 3.2 Test Mode and Environment .................................................................................................................. 5 3.3 Description of Test Auxiliary Equipment ................................................................................................ 5 3.4 Measurement Uncertainty ...................................................................................................................... 5 3.5 Additions to, Deviations, or Exclusions From the Method ...................................................................... 5 3.6 Laboratory Facility .................................................................................................................................. 5 3.7 Laboratory Location ................................................................................................................................ 5 3.8 Test Instruments List .............................................................................................................................. 6 3.9 Measurement Setup and Procedure ........................................................................................................... 7 4 Test Setup .............................................................................................................................................. 7 4.1 Test Procedure ....................................................................................................................................... 8 4.2 Test Results ................................................................................................................................................... 9 5 Summary ................................................................................................................................................ 9 5.1 Clause and Data Summary ................................................................................................................ 9 5.1.1 Test Limit .......................................................................................................................................... 10 5.1.2 Antenna Requirement .......................................................................................................................... 11 5.2 20dB Bandwidth ................................................................................................................................... 12 5.3 Field Strength of Fundamental ............................................................................................................. 13 5.4 Field Strength of Spurious Emissions .................................................................................................. 14 5.5 Duration Time ....................................................................................................................................... 18 5.6 Report No…

Text truncated - open the document above for the full version.

Test Report

Model Nam e HorizontalVertical 307.02 MHz 308.00MHz 308.08MHz307.02MHz 308.00MHz308.08MHz -15.20- 10.25-16.23-15.32-11.02-16.01 MAX Gain Polarization Azimuth Beam Pattern Impedance Antenna Length Manufacture Manufacture Address -5 ANTENNA SPECIFICATION SUMMAR Y Cente r Frequency 308MHz 440HA Ho rizontal and Vertical Omni-directional 50 Ohm 118.34mm ke y innovation Antenna Photo 633 Hickory Hill Dr Vernon Hills, IL 60061 640-224-0031 [email protected] 310 ALDER RD, DOVER DE 19904 USA Address: Company:Remote Tech LLC FrequencyGain(dB) (MHz)MaxMinAvg 307.02-13.35-18.66- 15.59 308.00-11.24-16.07- 13.54 308.08-12.97-19.32- 17.85 Max: -11.26 Min:-16.05 Scale: 5/div Horizontal: 307.02 MHz 308.00 MHz 308.08MHz Po wer (dBm) Max: -11.26Min: -16.05Scale: 5/div Vertical: 307.02 MHz 308.00 MHz 308.08MHz Po wer (dBm) FrequencyGain(dB) (MHz)MaxMinAvg 307.02-13.28-18.66-15.58 308.00-11.24-16.05-13.52 308. 08-12.95-19.20-17.84

Test Setup Photos

JianYan Testing Group Shenzhen Co., Ltd. JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2304052 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, People's Republic of China. Tel: +86-755-23118282, Fax: +86-755-23116366 Page 1 of 1 Setup Photos Radiated Spurious Emission Below 1GHz Above 1GHz ------End------

Contact Information

Applicant

John Strong
[email protected]302-336-8136Fax: 302-336-8136

Test Firm

JianYan Testing Group Shenzhen Co., Ltd.Bruce Zhang
[email protected]+86 (0) 755 23118282

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231308 MHz - 308 MHz-
Confidentiality
Long Term

Other Applications from Remote Tech LLC

2AOKM-MZ16

Smart Key

Jul 13, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Smart Key - FCC ID 2AOKM-BW12 - Remote Tech LLC
2AOKM-BW12

Smart Key

Jun 03, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Smart Key - FCC ID 2AOKM-SB6 - Remote Tech LLC
2AOKM-SB6

Smart Key

Jun 02, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Smart Key - FCC ID 2AOKM-BW12MS - Remote Tech LLC
2AOKM-BW12MS

Smart Key

Jun 02, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
REMOTE KEY - FCC ID 2AOKM-MZ162 - Remote Tech LLC
2AOKM-MZ162

REMOTE KEY

May 19, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter