FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Annex Products Pty Ltd/
  3. 2AOU9-QLA

2AOU9-QLAMotorcycle Wireless Charging Head

Annex Products Pty Ltd
Motorcycle Wireless Charging Head - FCC ID 2AOU9-QLA - Annex Products Pty Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 16, 2020
Application Purpose
Original Equipment
Date of Application
Mar 15, 2020
Equipment Note
Motorcycle Wireless Charging Head
Frequency Range
0.11000000 - 0.20500000
Company
Annex Products Pty Ltd
Country
Australia

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization <AnnexProductsPtyLtd> Company:AnnexProductsPtyLtd Address:Suite201,168GrevilleSt,Prahran,VICAustralia ProductName:MotorcycleWirelessChargingHead ModelNumber:QLA-MOT-WCH FCCIdentifier:2AOU9-QLA WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:CraigStevensDate:2020-03-12 Title:SeniorEngineer Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 <AnnexProductsPtyLtd> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2020-03-12 Subject:RequestforConfidentiality FCCID:2AOU9-QLA ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:CraigStevens Title: SeniorEngineer

External Photos

EUTPHOTO(ExternalPhotos)

ID Label/Location Info

Labelandlabellocation

Internal Photos

EUTPHOTO(InternalPhotos) ANT ※※※※※ENDOFREPORT※※※※※

RF Exposure Info

Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 4 FCC ID:2AOU9-QLA RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging Apps v03 2 Requirements According to the item 5 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Remark: Meet all the above requirements. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 4 3 Test Setup 4 Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The measurement probe was placed at test distance (15 cm from all sides and 20 cm from the top) which is between the edge of the charger and the geometric center of probe. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01v03. Remark:The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 4 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) Exposure Level Tester Narda ELT-400 N-0231 June. 26 2019 June. 25 2020 Magnetic field probe 100cm 2 Narda ELT probe 100cm 2 M0675 June. 26 2019 June. 25 2020 6 Test Result E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 0.110-0.205 0.77 0.67 0.65 0.64 614 E-Filed Strength at 20 cm from the top of the EUT (V/m) Frequency Range (MHz) Test Position E Limits (V/m) 0.110-0.205 0.62 614 H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.110-0.205 0.25 0.28 0.27 0.18 1.63 H-Filed Strength at 20 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.110-0.205 0.17 1.63 Test Engineer: Reviewer: Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 4 7 Test Set-up Photo

Test Report

GlobalUnitedTechnologyServicesCo.,Ltd. ReportNo.:GTS201912000087F01 AuthorizedSignature: RobinsonLo LaboratoryManager Thisresultsshowninthistestreportreferonlytothesample(s)tested,thistestreportcannotbereproduced,exceptin full,withoutpriorwrittenpermissionofthecompany.Thereportwouldbeinvalidwithoutspecificstampoftestinstitute andthesignaturesofcompilerandapprover. Page 1 of 19 TESTREPORT Applicant: AnnexProductsPtyLtd AddressofApplicant: Suite201,168GrevilleSt,Prahran,VICAustralia Manufacturer/Factory: TopwellSpringDevelopmentLtd Addressof Manufacturer/Factory: Room518-520,YousongBuilding,1stroadDonghuan, Longhua,Shenzhen EquipmentUnderTest(EUT) ProductName:MotorcycleWirelessChargingHead ModelNo.:QLA-MOT-WCH FCCID: 2AOU9-QLA Applicablestandards:FCCCFRTitle47Part15SubpartC Dateofsamplereceipt:Dec.11,2019 DateofTest:Dec.11,2019toDec.12,2019 Dateofreportissued:Dec.13,2019 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. ReportNo.:GTS201912000087F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 2 of 19 2Version VersionNo.DateDescription 00Dec.13,2019Original PreparedBy:Date:Dec.13,2019 ProjectEngineer CheckBy:Date:Dec.13,2019 Reviewer ReportNo.:GTS201912000087F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 3 of 19 3Contents Page 1COVERPAGE ........................................................................................................................................................... 1 2VERSION .................................................................................................................................................................. 2 3CONTENTS .............................................................................................................................................................. 3 4TESTSUMMARY .................................................................................................................................................... 4 4.1MEASUREMENTUNCERTAINTY ........................................................................................................................ 4 5GENERALINFORMATION ................................................................................................................................... 5 5.1GENERALDESCRIPTIONOFEUT .................................................................................................................... 5 5.2TESTMODE ....................................................................................................................................................... 6 5.3DESCRIPTIONOFSUPPORTUNITS .................................................................................................................. 6 5.4TESTFACILITY .................................................................................................................................................. 6 5.5TESTLOCATION ................................................................................................................................................ 6 5.6OTHERINFORMATIONREQUESTEDBYTHECUSTOMER ................................................................................ 6 6TESTINSTRUMENTSLIST .................................................................................................................................. 7 7TESTRESULTSANDMEASUREMENTDATA ................................................................................................ 9 7.1ANTENNAREQUIREMENT: ................................................................................................................................ 9 7.2CONDUCTEDEMISSIONS ................................................................................................................................ 10 7.3SPURIOUSEMISSION ...................................................................................................................................... 13 7.420DBOCCUPYBANDWIDTH .......................................................................................................................... 18 8TESTSETUPPHOTO .......................................................................................................................................... 19 9EUTCONSTRUCTIONALDETAILS ................................................................................................................. 19 ReportNo.:GTS201912000087F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 4 of 19 4TestSummary TestItemSectioninCFR47Result Antennarequirement15.203Pass ACPowerLineConductedEmission15.207Pass SpuriousEmission15.209(a)(f)Pass 20dBBandwidth15.215Pass Pass:TheEUTcomplieswiththeessentialrequirementsinthestandard. 4.1MeasurementUncertainty TestItemFrequencyRangeMeasurementUncertaintyNotes RadiatedEmission30MHz-200MHz3.8039dB(1) RadiatedEmission200MHz-1GHz3.9679dB(1) RadiatedEmission1GHz-18GHz4.29dB(1) RadiatedEmission18GHz-40GHz3.30dB(1) ACPowerLineConducted Emission 0.15MHz~30MHz3.44dB(1) Note(1):Themeasurementuncertaintyisforcoveragefactorofk=2andalevelofconfidenceof95%. ReportNo.:GTS201912000087F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 5 of 19 5GeneralInformation 5.1GeneralDescriptionofEUT ProductName:MotorcycleWirelessChargingHead ModelNo.:QLA-MOT-WCH SerialNo.:N/A Hardwareversion:N/A Softwareversion:N/A Tes…

Text truncated - open the document above for the full version.

Test Setup Photos

EUTTESTPHOTO

Contact Information

Applicant

Chris Peters(Co-founder & CIO)
[email protected]90699698Fax: 90699698

Technical Contact

Shenzhen ZKT Technology Co., Ltd.Lake xie
[email protected]0086-400 000 9970

Shenzhen · China

Non-Technical Contact

Shenzhen ZKT Technology Co., Ltd.Lake xie
[email protected]0086-400 000 9970

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Annex Products Pty Ltd

Bike Alarm & Finder - FCC ID 2AOU9-BAF - Annex Products Pty Ltd
2AOU9-BAF

Bike Alarm & Finder

Jun 11, 2026

Equipment Class

DTS - Digital Transmission System
12V-24V Waterproof Wireless Charger - FCC ID 2AOU9-HWCH - Annex Products Pty Ltd
2AOU9-HWCH

12V-24V Waterproof Wireless Charger

Jul 29, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Quad Lock 2-in-1 Magnetic Desktop Wireless Charger - FCC ID 2AOU9-2DWC - Annex Products Pty Ltd
2AOU9-2DWC

Quad Lock 2-in-1 Magnetic Desktop Wireless Charger

Jul 04, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz