Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Smart Body Fat Scale 1 Thank you for using smart body scales It utilizes a large body weight measurement with differential data display.Provide you with the data you need to keep track of your health .Provide you with the data you need to track . (Body Mass Index, BMI) We sincerely hope you enjoy using the new product. Intelligent Body Scale User Manual 2 Follow these safety precautions when using a smart body scale. be low: Thesmart body sc ale should notbeused to diagnoseor treat any medical condition.Youshould consult a doctorwhen undertaking any dietorexerc iseprogram. If youare pregnantorha vea pa cemaker orother internal de vice, you should notfully re ly ontheda ta provided by thisproduct. Allda ta is forre fe renc e andis nota substit uteforadvice froma li censed health careprofessional. If thesc ale malfuncti ons,fir st checkthebatt eries andre place themif needed. Checkthede vice be fo reeachuse. Do notusethede viceif da maged. Thecontinuoususeofa da maged unitmay cause injur y orimproper re sults. Scaleis a high-precisi onmeasuring de vice.Do not jump or stamponthesc ale. Do notdisassemble thesc ale. Pleaseha ndle thesc ale carefully to avoidbreaka ge . Place thesc ale ona ha rd,flat surface during use. Usingthesc ale ona softsurface li kecarpe t orli noleummay aff ect theaccuracy ofthesc ale re adings. Toensuremeasurementaccuracy, pleasegently steponthesc ale to wakeit upandWait until thesc ale shows“0.00”be fore measuring onthesc ale. Youneedalsowakeupthesc ale if it ha s beenmoved.Take yourmeasurementsat thesame timeeachday to ensurethemostaccurate re sults. Caution 3 Whe n thesc ale is notforusefora long te rm,please re movethe ba tt eries andplace thedevicein a dr y roomandprotect it aga inst extrememoisture, heat,li nt,dustanddirect sunlight. Neve r place any heavy objects onthede vice. Befo reusingthesc ale,makesureyouha veent ere d all your pe rsonal da ta through th e App. Usethescalewithba re feet. Thescalecanonly measurebody weig htif you'r e wearing shoes orsocks. Thissc ale is notwaterproof. Neve r immersethescalein water. Toclean thesurfa ce,usea da mpcloth orglasscle ane r. Do not usesoap orotherche micals. 33.0x 30.0x 2.6CM 2.00kg/ 4.40lb 3*1.5V AAA 11-550lb / 5- 250kg 0.2lb / 0.1kg lb / kg/ st Specifications 4 Precautions: 1. Pressure-sensitive switching machine, after placing on a hard and flat floor, after sensing the weight over 5kg.The screen will light up and turn on. 2. If batteries are included in the package, please load the batteries according to the positive and negative instructions. 3. If the scale is equipped with a built-in No. 7 battery, please remove the insulating sheet. 3 Product front Screens Buzzers Rubber foot BatteryUnit Product Back Overview 5 BMI Bluetooth Weight Difference Weight Display Electric Quanta KG LB ST 1. Before use:please load 3 No. 7 batteries or draw off the insulating sheet, The screen displays 8888 after the pressure is turned on After turning to display “ 0.0 ” can be on the scale measurement.Note:(Bluetooth symbol “ ” does not appear when the scale and Fitdays App are not connected) 2. Get on the scale to weigh: The weight value flashes 3 times and then display the weight value such as 71.8kg, after the buzzer rings one timeAfter the buzzer sounds, the BMI measurement will be carried out again and the BMI value will be displayed after waiting for 5 seconds, then the difference will be calculated, and all the measurements will be completed.After all the measurements are completed, the data will be transferred to Fitdays App for display, The process is shown in the figure below: 3. Comparison of weight difference:only the last measured weight value of an individual for comparison, weight gain is displayed as a "+" symbol on the screen, and weight loss is displayed as a "-" symbol on the screen, as shown in the following figure.The screen displays a "+" symbol for weight gain and a "-" symbol for weight loss, as shown in the figure below: Display Screen 4. Unit conversion:if you need to convert other units, please press the UNIT button at the bottom of the product or switch units on the Fitdays App to convert. button on the bottom of the product or switch units on the Fitdays App. 6. If the product is not weighed within 10 seconds after the measurement is completed without operation or after the product screen is zeroed, the product will automatically shut down. The product will shut down automatically. 1. Under the state of insufficient power, there is a battery symbol always on L0 display, and automatically shut down after 3 seconds, The product can not be used, please replace the new 7 AAA battery. 2. The maximum weighing weight of this machine is 250kg, if the weight exceeds 253kg, the product will display the overload Err If the weight exceeds 253kg, the product will display the overload Err symbol, and the product will shut down automatically after 3 seconds, as shown in the picture: 5. How to turn off the buzzer:Press and hold the UNIT button on the back for more than 2 seconds to switch the switch state, 1 sound means turn off the buzzer, 2 sounds means turn on the buzzer.The buzzer will sound 1 time to turn off the buzzer and 2 times to turn on the buzzer. Press and hold the back UNIT button for 2 seconds to turn the or turn on the buzzer. Power Level And Fault Indication 3. When the state of unstable weighing shows the following symbols, the product will automatically shut down after 3 seconds, as Figure: APP Tutorial Equipment Use 1.Please click the upper right corner of the scanned page and select "Open in Browser". Apps downloaded through other channels may not work. Before connecting the [Fitdays] App to the Smart Scale, please make sure your device meets the following Requirements: Running IOS 8.0 and above iPhone/ipod touch devices. Mobile devices running Android 5.0 and above and equipped with Bluetooth 4.0 and above Open the Fitdays App and turn on your phone's Bluetooth. IOS Bluetooth on: Sw…
Text truncated - open the document above for the full version.
Guangdong Welland Technology Co., Ltd. Agent Authorization Company: Guangdong Welland Technology Co., Ltd. Address: No.85 MinKe East Road, MinYing Science and Technology Park, ShiQi District, Zhongshan, China Product Name: Smart Body Fat Scale Model Number(s): BG1911LB, BG1911LB-A, BG1911B Product Description: Smart Body Fat Scale We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023-08-21 Name: Hillary Chan Company: Guangdong Welland Technology Co., Ltd.
Guangdong Welland Technology Co., Ltd Aug.21, 2023 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Explanation of differences between product types FCC ID : 2AP3Q-BG1911LB Model Number: BG1911LB, BG1911LB-A, BG1911B To Whom It May Concern: We, The Guangdong Welland Technology Co., Ltd. hereby declare that the models are identical except the model name and color . Except for the different above, no other modification is performed. Sincerely, Signature: Contact person: Hillary Chan
Report No.: AGC06164230803AP02 Page 1 of 3 EXTERNAL PHOTOS TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC06164230803AP02 Page 2 of 3 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC06164230803AP02 Page 3 of 3 LEFT VIEW OF EUT RIGHT VIEW OF EUT ****************************************End of Report*************************************
FCC ID Label Location 100mm&40mm FCC ID: 2AP3Q-BG1911LB
Report No.: AGC06164230803AP02 Page 1 of 3 INTERNAL PHOTOS OPEN VIEW OF EUT (FIGURE 1) OPEN VIEW OF EUT (FIGURE 2) Report No.: AGC06164230803AP02 Page 2 of 3 INTERNAL VIEW OF EUT (FIGURE 1) INTERNAL VIEW OF EUT (FIGURE 2) BT Antenna Report No.: AGC06164230803AP02 Page 3 of 3 INTERNAL VIEW OF EUT (FIGURE 3) ****************************************End of Report*************************************
RF EXPOSURE EVALUATION 1. PRODUCT INFORMATION FCC ID 2AP3Q-BG1911LB Product Description Smart Body Fat Scale Model Name BG1911LB, BG1911LB-A, BG1911B Frequency Band (Operating) WLAN: 2.412GHz ~ 2.462GHz WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz WLAN: 5.745GHz ~ 5825GHz Bluetooth: 2.402GHz ~ 2.480GHz Others (NFC:13.56MHz) Device Category Portable (<20cm separation) Mobile (>20cm separation) Others: Antenna Diversity Single antenna Multiple antennas Max. Output Power -0.507dBm (Max) Antenna Gain 0.89dBi Minimum Assessment Distance 5mm Evaluation Applied MPE Evaluation SAR Evaluation Evaluation Result Pass 2. PORTABLE DEVICE EVALUATION METHOD AND LIMIT Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [if(GHz)] s 3.0 for 1-g SAR and ñ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz. Power and distance are rounded to the nearest mW and mm before calculation. The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm) ( f(MHz)/150)] mW, at 100MHz to 1500 MHz; b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)-10] mW at > 1500 MHz and ≤6 GHz; 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by 1/2 for test separation distances ñ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. 3. MOBILE DEVICE EVALUATION METHOD AND LIMIT Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate, since exposures are assumed to occur at distances of 20 cm or more from persons. LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE Frequency Range (MHz) E-field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (Minutes) 0.3 -- 1.34 614 1.63 (100)* 30 1.34 -- 30 824/f 2.19/f (180/f 2 )* 30 30 -- 300 27.5 0.073 0.2 30 300 -- 1500 -- -- f/1500 30 1500 -- 100,000 -- -- 1.0 30 *Note: 1. f= Frequency in MHz * Plane-wave Equivalent Power Density 2. The averaging time for General Population/Uncontrolled exposure to fixed transmitters is not applicable for mobile and portable transmitters. See 47 CFR §§2.1091 and 2.1093 on source-based time-averaging requirement for mobile and portable transmitters. S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. MEASUREMENT RESULT Test Mode Channel Frequency (MHz) Max Output power (dBm) Max Output power (mW) Calculati on Value (Note 1) Threshold Value GFSK BT_BLE 2402 -0.507 0.89 0.28 3.0 Note 1: Calculation Value =[(max. power of channel, mW)/(min. test separation distance, mm)] ·[√f(GHz)]. Fox example: 0.89/5*√2.402=0.28 ≤ 3.0 According to KDB447498 D01 V06, threshold at which no SAR required is ≤3.0 for 1-g SAR, separation distance is 5mm, and no simultaneous SAR measurement is required. 5. CONCLUSION Since Source-base time average power is below SAR test exclusion power thresholds, the SAR evaluation is not required.
Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 RF:王志锋 TEL: 13823540870 Client: Guangdong Welland Technology Co., Ltd. Project: BG1911LB Antenna standard: BT Shenzhen DBT Telecommunication Technology CO.,LTD Antenna Testing Report Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 OTA-800 Brand:ETS Frequency range:370MHz-8.5GHz Features:passive、active test;G net、C net、 2G/3G/4G,WIFI and BT, TRP、TIS test. 测试设备 5071C Brand:Agilent Frequency range:9KHz-8.5GHz Features:2G/3G/4G/BT/WIFI antenna comprehensive passive test。 8960 Brand:Agilent Frequency range:292MHz-2700GHz Features:2G/3G avtive test。 CMW500 Brand:Rohde & Schwarz Frequency range:70KHz-6GHz Features:2G/3G/4G/BT/WIFI/NB-Lot antenna comprehensive passive test。 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 3.Antenna assembly position Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 Electrical Parameter Frequency Range (MHz) 2400~2500 VSWR ≤7.0 Input Impedance(Ω) 50 Gain(dBi) 0.89 Polarization(°) vertical Max power(W) 10 Antenna Type PCB antenna Working Temperature(°C) -40~+80 4.Electrical Parameter Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 5.Antenna Passive Data Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 Freq Effi Gain (MHz) (%) (dBi) 2400 1.6 0.89 2410 1.36 0.87 2420 1.77 0.86 2430 1.45 0.85 2440 1.42 0.79 2450 1.18 0.78 2460 1.63 0.77 2470 1.01 0.76 2480 1 0.69 2490 0.73 0.61 2500 1.42 0.67 6.Antenna Gain/Efficiency/3D Apple Chart Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 7.Antenna Direction Map
Page 1 of 39 FCC Test Report Report No.: AGC06164230803FE02 FCC ID : 2AP3Q-BG1911LB APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Smart Body Fat Scale BRAND NAME : N/A MODEL NAME : BG1911LB, BG1911LB-A, BG1911B APPLICANT : Guangdong Welland Technology Co., Ltd. DATE OF ISSUE : Aug. 09, 2023 STANDARD(S) : FCC Part 15.247 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC06164230803FE02 Page 2 of 39 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 09, 2023 Valid Initial Release Report No.: AGC06164230803FE02 Page 3 of 39 TABLE OF CONTENTS 1. VERIFICATION OF COMPLIANCE .................................................................................................................. 4 2. GENERAL INFORMATION .............................................................................................................................. 5 2.1. PRODUCT DESCRIPTION ........................................................................................................................ 5 2.2. TABLE OF CARRIER FREQUENCYS ....................................................................................................... 5 2.3. RELATED SUBMITTAL(S)/GRANT(S) ....................................................................................................... 6 2.4. TEST METHODOLOGY ............................................................................................................................. 6 2.5. SPECIAL ACCESSORIES .......................................................................................................................... 6 2.6. EQUIPMENT MODIFICATIONS ................................................................................................................. 6 2.7. ANTENNA REQUIREMENT ....................................................................................................................... 6 3. MEASUREMENT UNCERTAINTY ................................................................................................................... 7 4. DESCRIPTION OF TEST MODES ................................................................................................................... 8 5. SYSTEM TEST CONFIGURATION .................................................................................................................. 9 5.1. CONFIGURATION OF TESTED SYSTEM ................................................................................................. 9 5.2. EQUIPMENT USED IN TESTED SYSTEM ................................................................................................ 9 5.3. SUMMARY OF TEST RESULTS ................................................................................................................ 9 6. TEST FACILITY .............................................................................................................................................. 10 7. PEAK OUTPUT POWER ................................................................................................................................ 11 7.1. MEASUREMENT PROCEDURE .............................................................................................................. 11 7.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 11 7.3. LIMITS AND MEASUREMENT RESULT .................................................................................................. 12 8. BANDWIDTH .................................................................................................................................................. 14 8.1. MEASUREMENT PROCEDURE .............................................................................................................. 14 8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 14 8.3. LIMITS AND MEASUREMENT RESULTS ............................................................................................... 14 9. CONDUCTED SPURIOUS EMISSION........................................................................................................... 18 9.1. MEASUREMENT PROCEDURE .............................................................................................................. 18 9.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 18 9.3. MEASUREMENT EQUIPMENT USED .................................................................................................... 18 9.4. LIMITS AND MEASUREMENT RESULT .................................................................................................. 18 10. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY ........................................................ 25 10.1. MEASUREMENT PROCEDURE ............................................................................................................ 25 10.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................. 25 10.3. MEASUREMENT EQUIPMENT USED .................................................................................................. 25 10.4. LIMITS AND MEASUREMENT RESULT................................................................................................ 25 11. RADIATED EMISSION ................................................................................................................................. 27 11.1. MEASUREMENT PROCEDURE ............................................................................................................ 27 11.2. TEST SETUP .......................................................................................................................................... 28 11.3. LIMITS AND MEASUREMENT RESULT................................................................................................ 2…
Text truncated - open the document above for the full version.
Report No.: AGC06164230803AP01 Page 1 of 2 TEST SETUP PHOTOS RADIATED EMISSION TEST SETUP BELOW 1GHz RADIATED EMISSION TEST SETUP ABOVE 1GHz Report No.: AGC06164230803AP01 Page 2 of 2 RF CONDUCTED TEST SETUP ****************************************End of Report*************************************
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 900.00 µW |
Smart Scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Kitchen scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System