FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangdong Welland Technology Co., Ltd./
  3. 2AP3Q-FG2109LB

2AP3Q-FG2109LBSmart Body Fat Scale

Guangdong Welland Technology Co., Ltd.
Smart Body Fat Scale - FCC ID 2AP3Q-FG2109LB - Guangdong Welland Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 16, 2023
Application Purpose
Original Equipment
Date of Application
Jan 16, 2023
Equipment Note
Smart Body Fat Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Guangdong Welland Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

VA Body Composition Scale Model No.: FG2019LB Instruction Manual EN DE FR IT ES Read this manual before using and save for future reference 1 1. Download the "Fitdays" App from Apple Store or Google Play. 2. Remove the plastic isolation sheet from the battery cover. 3. Place the scale on the hard flat surface. 4. Measure with bare feet and fully contact with the electrodes. 5. Turn on the smart App and get the scale connected before measuring. 6. Follow below operations and make sure the posture is correct for measuring. Quick Start Guide VA Body Composition Scale WARNING Product Specification Product size:278x278x27.5mm LCD screen display:107x60mm Weight unit:Kg/lb/st Weight limit:5kg-180kg Weight division:0.1kg/0.2Ib Power Supply:4 x 1.5V AAA batteries Operating temperature:10-40 Operation humidity:40%-80% RH Thanks for choosing VA Body Composition Scale . This scale uses bio-electrical impedance analysis (BIA) technology to help you conveniently measure Body weight, Body balance, BMI, Body fat rate, Visceral fat, Body water, Skeletal muscle rate, Muscle mass, Bone mass, Protein, BMR, Body age and etc. ! DO NOT use with medical implants such as pacemakers. DO NOT stand on the edge of the scale or jump on it; DO NOT overload the scale (Max.180kg/396lb/28st) DO NOT drop scale or drop the objects on it as this may damage the sensors. DO NOT immerse the scale in water or use chemical cleaning agents. Clean the scale with a slightly damp cloth. Not recommended for pregnant women. Not recommended for infants, toddlers, and children who are under 10 years of age. Any measurement obtained using this device is for reference only and should not be consid ered as a medical opinion. DO NOT be used to diagnose or treat any medical condition. You should consult your primary care doctor or physician before making changes to your diet, exercise plan or physical activities. Always place the scale on a hard, dry and flat surface before measurement. Make sure your feet are dry before stepping on the scale. Connect the batteries in accordance with the correct polarities indicated. Remove batteries if the scale is not be used for a prolonged period of time DO NOT use the device if damaged. The continuous use of a damaged unit may cause injury or improper results. Please check the device before each use. First check the batteries power and replace it if needed, if the scale malfunction. Be careful when using on the wet and slippery surface. 2 Indication Symbols Product Overview The batteries in the scales are too weak. Insert new batteries (see the"Replacing the Batteries" chapter). More than 180kg are on the scales. The scales are overloaded. An error has occurred during measurement. Step off the scales for 5 seconds and step onto them again to repeat the measuring process. Electrode sensorsElectrode sensors Sensor feet Battery cover 3 iOS: 8.0 or higher Android: 5.0 or higher Indication Symbols 1.Scan the below QR Code to download APP, or search “Fitdays” from Apple Store and Google Play. 2.Download and install the App “Fitdays” on your device. 3.The App icon will appear on your phone or tablet after the installation is completed. 1.Open the App “Fitdays” on your device. 2.Register your own account by email or login with social media account. 3.Add personal data and confirm. Install Fitdays App How to use the scale with Fitdays App for the first time? 4 4.iOS: Make sure Bluetooth is on and Bluetooth Authorization is allowed. Android: Make sure Bluetooth is on and GPS and Location is allowed. 5.In the back of scale, pull out the insulation sheet, then place the scale on a hard, flat surface, step onto the scale with single foot to activate the scale. Wait until the display shows “0.0kg”. 6.Pair the scale through Bluetooth. Make sure the scale is on when pairing. Leaving the APP on its main screen, it will automatically connect to the scale. Or you could also click “Account“ ----> “Device”---> “+” ----> “Bluetooth” find the scale Bluetooth ID: EEBBL-VA. 7.The app will show your data within a few seconds. iOSAndroid 5 Troubleshooting Bluetooth Connection 1) Regular Connection See the "How to use the scale with Fitdays App for the first time?" chapter 2 ) If the regular connection to Bluetooth failed, please try the below steps: 1. Reset the scale by taking out one battery for 5 seconds and putting it back in. 2. Reset the Bluetooth connection. Ensure Bluetooth and GPS (Android only) are enabled on your device. 1. Bluetooth failed to connection. Make sure the scale and the Bluetooth and GPS (Android only) on your phone are on; Check the system version of your smart phone, it must be iOS 8.0 or higher/Android 6.0 higher; For successfully connection, there is a Bluetooth icon on the display and the word “Connected” will show on the circle of the homepage on phone; If fail to connect via Bluetooth, please click Account--->Device to find the scale ID: EEBBL-P1. 2.No body fat data after weighting. Must step onto the scale with bare feet. Make sure your feet and the scale are both dry. Step off the scale when measurement does not finish (Please keep standing on the scale around 10 second until the number on the display stops flashing). Bluetooth is not turned on. Bluetooth is paired with a difference scale. 3.Incorrect weight data occurs. Check whether the scale is on a hard, flat surface. Check each sensor foot on the back to make sure nothing is stuck to the bottom of it. 4.Incorrect fat-muscle ratio shows on App. The body parameter settings are incorrect, check to make sure you entered the correct gender, height, and age. Check if you activate the Athlete Mode. 5.How do I re-calibrate the scale after removing? Step on the scale to turn it on. Let it automatically drop to 0.0kg to calibrate. 6 6.The scale does not turn on. Check if the insulation sheet has been pulled out. Check if battery has run out of power and change new batteries if needed. Place the scale far away from the children in case of falling down o…

Text truncated - open the document above for the full version.

Cover Letter(s)

Guangdong Welland Technology Co., Ltd Jan.13, 2023 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Explanation of differences between product types FCC ID : 2AP3Q-FG2109LB Model Number: FG2109LB, FI2109LB, FG2109LB-A, FI2109LB-A, FG2209LB, FI2209LB To Whom It May Concern: We, The Guangdong Welland Technology Co., Ltd. hereby declare that the models are identical except the model name and appearance color . Except for the different above, no other modification is performed. Sincerely, Signature: Guangdong Welland Technology Co., Ltd. Contact person: Hillary Chan

Cover Letter(s)

Guangdong Welland Technology Co., Ltd. Agent Authorization Company: Guangdong Welland Technology Co., Ltd Address: No.85 MinKe East Road, MinYing Science and Technology Park, ShiQi District, Zhongshan, China Product Name: Smart Body Fat Scale Model Number(s): FG2109LB, FI2109LB, FG2109LB-A, FI2109LB-A, FG2209LB, FI2209LB Product Description: Smart Body Fat Scale We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023-01-13 Name: Hillary Chan Company: Guangdong Welland Technology Co., Ltd.

Cover Letter(s)

GuangdongWellandTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2023-01-13 Subject;RequestforConfidentiality FCCID:2AP3Q-FG2109LB ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely GuangdongWellandTechnologyCo.,Ltd. Contactperson: HillaryChan

External Photos

Report No.: AGC06164221202AP03 Page 1 of 3 EXTERNAL PHOTOS TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC06164221202AP03 Page 2 of 3 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC06164221202AP03 Page 3 of 3 LEFT VIEW OF EUT RIGHT VIEW OF EUT ****************************************End of Report****************************************

ID Label/Location Info

FCC ID Label Location 100mm&40mm FCC ID: 2AP3Q-FG2109LB

Internal Photos

Report No.: AGC06164221202AP03 Page 1 of 3 INTERNAL PHOTOS OPEN VIEW OF EUT-1 OPEN VIEW OF EUT-2 Report No.: AGC06164221202AP03 Page 2 of 3 INTERNAL VIEW OF EUT-1 INTERNAL VIEW OF EUT-2 Report No.: AGC06164221202AP03 Page 3 of 3 INTERNAL VIEW OF EUT-3 ****************************************End of Report**************************************** BT Antenna

RF Exposure Info

RF EXPOSURE EVALUATION 1. PRODUCT INFORMATION Product Description Smart Body Fat Scale Model Name FG2109LB Series Model FI2109LB, FG2109LB-A, FI2109LB-A, FG2209LB, FI2209LB FCC ID 2AP3Q-FG2109LB 2. EVALUATION METHOD According to 447498 D01 General RF Exposure Guidance v06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. Where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation 3. CALCULATION BR&EDR: P t =-0.096dBm=0.98mW The value of the Maximum output power P t is referred to the test report of the CFR47 §15.247. The result for RF exposure evaluation SAR=(0.98mW / 5mm).[√2.402GHz)]=0.304<3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. 4. CONCLUSION The SAR evaluation is not required.

Test Report

FG2109LB Antenna Gain 1、Line loss:0.49dBi 2、Max Antenna Gain 0.8 dBi 3、Antenna shape and size:serpentine inverted F antenna,Length 12.8mm,width 8mm 4、Frequencyofthe antenna Antenna frequency at 2.445GHz return loss is -30dB,impedance is about 50,bandwidth 80m。 5、Test antenna efficiency

Test Report

Page 1 of 39 FCC Test Report Report No.: AGC06164221202FE02 FCC ID : 2AP3Q-FG2109LB APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Smart Body Fat Scale BRAND NAME : N/A MODEL NAME : FG2109LB, FI2109LB, FG2109LB-A, FI2109LB-A, FG2209LB, FI2209LB APPLICANT : Guangdong Welland Technology Co., Ltd. DATE OF ISSUE : Dec. 29, 2022 STANDARD(S) : FCC Part 15.247 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC06164221202FE02 Page 2 of 39 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Dec. 29, 2022 Valid Initial Release Report No.: AGC06164221202FE02 Page 3 of 39 TABLE OF CONTENTS 1. VERIFICATION OF COMPLIANCE .................................................................................................................. 4 2. GENERAL INFORMATION .............................................................................................................................. 5 2.1. PRODUCT DESCRIPTION ........................................................................................................................ 5 2.2. TABLE OF CARRIER FREQUENCYS ....................................................................................................... 5 2.3. RELATED SUBMITTAL(S)/GRANT(S) ....................................................................................................... 6 2.4. TEST METHODOLOGY ............................................................................................................................. 6 2.5. SPECIAL ACCESSORIES .......................................................................................................................... 6 2.6. EQUIPMENT MODIFICATIONS ................................................................................................................. 6 2.7. ANTENNA REQUIREMENT ....................................................................................................................... 6 3. MEASUREMENT UNCERTAINTY ................................................................................................................... 7 4. DESCRIPTION OF TEST MODES ................................................................................................................... 8 5. SYSTEM TEST CONFIGURATION .................................................................................................................. 9 5.1. CONFIGURATION OF TESTED SYSTEM ................................................................................................. 9 5.2. EQUIPMENT USED IN TESTED SYSTEM ................................................................................................ 9 5.3. SUMMARY OF TEST RESULTS ................................................................................................................ 9 6. TEST FACILITY .............................................................................................................................................. 10 7. PEAK OUTPUT POWER ................................................................................................................................ 11 7.1. MEASUREMENT PROCEDURE .............................................................................................................. 11 7.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 11 7.3. LIMITS AND MEASUREMENT RESULT .................................................................................................. 12 8. BANDWIDTH .................................................................................................................................................. 14 8.1. MEASUREMENT PROCEDURE .............................................................................................................. 14 8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 14 8.3. LIMITS AND MEASUREMENT RESULTS ............................................................................................... 14 9. CONDUCTED SPURIOUS EMISSION........................................................................................................... 18 9.1. MEASUREMENT PROCEDURE .............................................................................................................. 18 9.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 18 9.3. MEASUREMENT EQUIPMENT USED .................................................................................................... 18 9.4. LIMITS AND MEASUREMENT RESULT .................................................................................................. 18 10. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY ........................................................ 25 10.1. MEASUREMENT PROCEDURE ............................................................................................................ 25 10.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................. 25 10.3. MEASUREMENT EQUIPMENT USED .................................................................................................. 25 10.4. LIMITS AND MEASUREMENT RESULT................................................................................................ 25 11. RADIATED EMISSION ................................................................................................................................. 27 11.1. MEASUREMENT PROCEDURE ............................................................................................................ 27 11.2. TEST SETUP .......................................................................................................................................... 28 11.3. LIMITS AND MEASUREMENT RESULT.................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: AGC06164221202AP02 Page 1 of 2 TEST SETUP PHOTOS RADIATED EMISSION TEST SETUP BELOW 1GHz RADIATED EMISSION TEST SETUP ABOVE 1GHz Report No.: AGC06164221202AP02 Page 2 of 2 RF CONDUCTED TEST SETUP ****************************************End of Report*************************************

Contact Information

Applicant

Hillary Chan(Sales Manager)
[email protected]86-760-2816 0369Fax: 0760-28160370

Technical Contact

Guangdong Welland Technology Co., Ltd.
[email protected]

China

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from Guangdong Welland Technology Co., Ltd.

2AP3Q-FG2415WB

Smart Scale

Jul 24, 2026

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2AP3Q-FG2504WB-A - Guangdong Welland Technology Co., Ltd.
2AP3Q-FG2504WB-A

Smart Body Fat Scale

Apr 29, 2026

Equipment Class

DTS - Digital Transmission System
Kitchen scale - FCC ID 2AP3Q-KG2458ULB - Guangdong Welland Technology Co., Ltd.
2AP3Q-KG2458ULB

Kitchen scale

Apr 21, 2026

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2AP3Q-FG450WB-A - Guangdong Welland Technology Co., Ltd.
2AP3Q-FG450WB-A

Smart Body Fat Scale

Apr 21, 2026

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2AP3Q-FI2502ULB - Guangdong Welland Technology Co., Ltd.
2AP3Q-FI2502ULB

Smart Body Fat Scale

Mar 09, 2026

Equipment Class

DTS - Digital Transmission System