Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 19, 2025
Application Purpose
Original Equipment
Equipment Note
Kitchen scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Guangdong Welland Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Kitchen Scale 1 Product Overview The smart kitchen scale combines precise weighing capabilities with smart nutrition tracking.Designed for modern kitchens,this digital scale integrates with a mobile app to monitor macronutrients like fats,carbs , and proteins. Product Specifications Max Capacity: 5kg/11lb Min Weight: 2g Division: 1g/0.1oz Units: g,ml(water),ml(milk),oz,lb:oz Power: 4×AAA batteries Weighing Platform: Stainless steel Display: LED 48×38mm TFT 2.0-inch Bluetooth connectivity Product Diagram Stainless steel platform LED display TFT display On&off button /Tare button Unit button/Confirm button Quick select button 2 Getting Started POWER ON : Insert 4×AAA batteries into the battery compartment. Short press TARE to power on TURN OFF: Long press TARE. Auto-off:Scale powers down after 120s . Weighing & Unit Conversion Default unit : g Press UNIT to toggle between : g ml(water) ml(milk) oz lb:oz • • • • • • • • • Started Battery cover Scale feet 3 How to Operate 1.Download Fitdays+ APP 2.Pairing Instructions (1)Turn on the kitchen scale (2)Open the app and enable Bluetooth (3)Select device “MY_SCALE”. 3.Choose food type Option1: Select the corresponding food intake time and type on the app 4 Option2: The scale can store 50 different foods, and you can quickly select the corresponding food by using the up/down selection buttons on the scale. 4.Customize frequently used foods The app supports customizing and resorting 50 frequently used foods. 5 5.Check Nutrient Analysis and Trend Click Nutrient Analysis to view more detailed nutrient intake analysis and trends. Daily Calorie Goal Tracking Set calorie targets and monitor progress directly for weight management support. Low Modest High Too high 6 Troubleshooting Safety & Maintenance Do not immerse in water. Clean with damp cloth. Store in dry, cool place. Keep away from strong electromagnetic sources. ISSUE "Lo" on display "Err" on display No Bluetooth Inaccurate weight CAUSE Low battery Overweight (>5020g) Not paired/ app closed Not on flat surface SOLUTION Replace all 4x AAA batteries Remove excess weight Reconnect in app settings Use on flat, stable platform • • • • 1 Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica- tions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from th at to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Attestation Statements

Guangdong Welland Technology Co., Ltd. Code 00018768 Ed. 1 Item 1. The device is able to install software/program installation? ☐Yes, go to Item 2. ☒No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky cybersecurity or anti-virus software. Item 2. Technical Requirements for Kaspersky Cybersecurity Software: # General Requirements (For all Devices) Yes / No or N/A Comments 1 Internet connection for activation and updates (For all Operating Systems) N/A Device Kitchen scale Company name Guangdong Welland Technology Co., Ltd. Grantee code 2AP3Q FCC ID 2AP3Q-KN2432LB FRN 0027591197 Contact name Hillary Chan Address No. 7 Minke East Road, Shiqi Sub-district, Zhongshan City, China Telephone number 86-760-2816 0369 [email protected] Chipset/module information OM6626B Operating System (if applicable) N/A Storage Capacity (hard drive or other permanent memory storage, if applicable) N/A 2 # General Requirements (For Windows Devices) Yes / No or N/A Comments 1 Storage: 1500 MB free space on the hard drive N/A 2 Operating System: Microsoft Windows 8, 8.1, 10 & 11 Home / Pro / Enterprise Microsoft Windows 7 Starter / Home Basic & Premium / Professional / Ultimate SP1 or higher N/A 3 Processor: 1 GHz or higher (x86 or x64) N/A 4 Memory (RAM)1 GB (32-bit) or 2 GB (64-bit) N/A 5 Screen Resolution: Minimum resolution of 1024 x 768 N/A # General Requirements (For macOS devices) Yes / No or N/A Comments 1 Operating System macOS® 13 – 14 N/A 2 Memory (RAM)4 GB N/A 3 Storage: 3455 MB free space on the hard drive N/A # General Requirements (For Android Devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: Android™ 10 – 14 N/A 3 Screen Resolution: Minimum resolution of 320 x 480 N/A # General Requirements (for iOS devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: iOS® 17 N/A # General Requirements (For Linux system) Yes / No or N/A Comments 3 1 Hard drive: 1 GB of free space N/A 2 CPU: Intel Pentium 1 GHz or higher N/A 3 RAM: 1 GB N/A 4 Minimum software requirements: AlmaLinux OS 8 or later; AlterOS 7.5 or later; Astra Linux Common Edition 2.12 or later; CentOS 6.7 or later; Debian GNU/Linux 10.0 or later; EulerOS 2.0 or later; Oracle Linux 7.3 or later ; Red Hat Enterprise Linux 6.7 or later ; Rocky Linux 8.5 or later ; SUSE Linux Enterprise Server 12.5 or later; Ubuntu 12.04 or later ; Uncom OS Home / Business / Education / Enterprise 2.2 or later; ALT Linux Workstaton / Workstation K / Server / Education 8 or later; ROSA Linux Workstation / Server 12 or later ; RED OS 7.3 and later ; N/A After reviewed the technical requirements, is the device capable of supporting the installation of Kaspersky software? ☐ Yes, go to Item 3. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky software 4 Item 3. Connectivity Capabilities: # Physical Interface Purpose Justification 1 1 # Wireless Interface Purpose Justification 1 1 After the review of this items, the device: ☒ Cannot support installation of any cybersecurity or anti-virus software on the covered list. ☐ Potentially can operate with any cybersecurity or anti-virus software on the covered list – additional third- party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – “Proof of Compliance with Covered List Software Requirements” of this document applies Signature: Name: Hillary Chan Date: Sep. 22, 2025 1 The justification field is used to justify why the software cannot be received through that interface. Check the annex for more indications.

Attestation Statements

Guangdong Welland Technology Co., Ltd. No. 7 Minke East Road, Shiqi Sub-district, Zhongshan City, China Sep. 22, 2025 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Explanation of differences between product types FCC ID: 2AP3Q-KN2432LB Models: KN2432LB, KN2432LB-A, KN2432 To Whom It May Concern: We, The Guangdong Welland Technology Co., Ltd. hereby declare that the model : KN2432LB-A, KN2432 is identical with the model : KN2432LB, except the model name and appearance colors. All the models are the same circuit and RF module, except for the model name and appearance colors. Sincerely, Guangdong Welland Technology Co., Ltd. Signature: [Hillary Chan, Sales Manager]

Attestation Statements

TCB CALL página 1 File FCC ID: 2AP3Q-KN2432LB Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : https://opencorporates.com/companies/us_il/LLC_12842678 In google: TCB CALL página 2 Bank information TCB CALL página 3 TCB CALL página 4 TCB CALL página 5 TCB CALL página 6 TCB CALL página 7 TCB CALL página 8 TCB CALL página 9 ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit " US Agent Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit " US Agent Letter" >

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Guangdong Welland Technology Co., Ltd. Address: No. 7 Minke East Road, Shiqi Sub-district, Zhongshan City, China Product Name: Kitchen scale Model Number: KN2432LB, KN2432LB-A, KN2432 FCC Identifier: 2AP3Q-KN2432LB We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Hillary Chan Date: Sep. 22, 2025 Title: Sales Manager Signature of applicant:

External Photos

Report No.: AGC06164250901AP03 Page 1 of 3 EXTERNAL PHOTOS TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC06164250901AP03 Page 2 of 3 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC06164250901AP03 Page 3 of 3 LEFT VIEW OF EUT RIGHT VIEW OF EUT ****************************************End of Report*************************************

ID Label/Location Info

FCC ID Label Location 48mm*38.3mm FCC ID: 2AP3Q-KN2432LB This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Report No.: AGC06164250901AP03 Page 1 of 5 INTERNAL PHOTOS OPEN VIEW OF EUT (FIGURE 1) OPEN VIEW OF EUT (FIGURE 2) Report No.: AGC06164250901AP03 Page 2 of 5 OPEN VIEW OF EUT (FIGURE 3) INTERNAL VIEW OF EUT (FIGURE 1) Report No.: AGC06164250901AP03 Page 3 of 5 INTERNAL VIEW OF EUT (FIGURE 2) INTERNAL VIEW OF EUT (FIGURE 3) BT Antenna Report No.: AGC06164250901AP03 Page 4 of 5 INTERNAL VIEW OF EUT (FIGURE 4) INTERNAL VIEW OF EUT (FIGURE 5) Report No.: AGC06164250901AP03 Page 5 of 5 INTERNAL VIEW OF EUT (FIGURE 6) INTERNAL VIEW OF EUT (FIGURE 7) ****************************************End of Report*************************************

RF Exposure Info

Page 1 of 10 RF Exposure Report Report No.: AGC06164250901FH01 FCC ID : 2AP3Q-KN2432LB APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Kitchen scale BRAND NAME : N/A MODEL NAME : KN2432LB, KN2432LB-A, KN2432 APPLICANT : Guangdong Welland Technology Co., Ltd. DATE OF ISSUE : Sep. 22, 2025 STANDARD(S) : FCC Part 2 Subpart J §2.1093 FCC KDB 447498 D01 V06 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC06164250901FH01 Page 2 of 10 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Sep. 22, 2025 Valid Initial Release Report No.: AGC06164250901FH01 Page 3 of 10 Table of Contents 1. General Information ........................................................................................................................................ 4 2. Product Information ........................................................................................................................................ 5 2.1 Product Technical Description ................................................................................................................... 5 3. Test Environment ............................................................................................................................................ 6 3.1 Address Of The Test Laboratory ............................................................................................................... 6 3.2 Test Facility ................................................................................................................................................ 6 3.3 Environmental Conditions ......................................................................................................................... 7 4. Portable Device Evaluation Method and Limit ............................................................................................. 8 5. Measurement Results ..................................................................................................................................... 9 6. Measurement Evaluation ................................................................................................................................ 9 Report No.: AGC06164250901FH01 Page 4 of 10 1. General Information Applicant Guangdong Welland Technology Co., Ltd. Address No. 7 Minke East Road, Shiqi Sub-district, Zhongshan City, China Manufacturer Guangdong Welland Technology Co., Ltd. Address No. 7 Minke East Road, Shiqi Sub-district, Zhongshan City, China Factory Guangdong Welland Technology Co., Ltd. Address No. 7 Minke East Road, Shiqi Sub-district, Zhongshan City, China Product Designation Kitchen scale Brand Name N/A Test Model KN2432LB Series Model(s) KN2432LB-A, KN2432 Difference Description All the same except for the model name and appearance colors. Date of receipt of test item Sep. 09, 2025 Date of Test Sep. 09, 2025 to Sep. 22, 2025 Deviation from Standard No any deviation from the test method Condition of Test Sample Normal Test Result Pass Test Report Form No AGCER-FCC-RF Exposure-V1 Note: The test results of this report relate only to the tested sample identified in this report. Prepared By Thea Huang (Project Engineer) Sep. 22, 2025 Reviewed By Bibo Zhang (Reviewer) Sep. 22, 2025 Approved By Angela Li (Authorized Officer) Sep. 22, 2025 Report No.: AGC06164250901FH01 Page 5 of 10 2. Product Information 2.1 Product Technical Description Frequency Band (Operating) Bluetooth: 2.402GHz ~ 2.480GHz Other: Hardware Version V1.2 Software Version A1.0.1 Modulation Type BLE GFSK 1Mbps GFSK 2Mbps Maximum Transmitter Power -0.501dBm Device Category Portable (<20cm separation) Mobile (>20cm separation) Others: Antenna Diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna Designation PCB Antenna Antenna Gain 0.88dBi Minimum Assessment Distance 5mm Evaluation Applied MPE Evaluation SAR Evaluation Report No.: AGC06164250901FH01 Page 6 of 10 3. Test Environment 3.1 Address Of The Test Laboratory Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 Test Facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to follow CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories.) A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to follow ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. FCC-Registration No.: 975832 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files with Registration 975832. IC-Registration No.: 24842(CAB identifier: CN0063) Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the Certification and Engineering Bureau of Industry Canada. The acceptance letter from the IC is maintained in our files with Registration 24842. Report No.: AGC06164250901FH01 Page 7 of 10 3.3 Environmental Conditions NORMAL CONDITIONS Temperature range (°C) 15 - 35 Relative humidity range 20 % - 75 % Pressure range (kPa) 86 - 106 Power supply DC 6.0V by battery Note: The Extreme Temperature and Extreme Voltages declared by the manufacturer. Report No.:…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 49 FCC Test Report Report No.: AGC06164250901FR01 FCC ID : 2AP3Q-KN2432LB APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Kitchen scale BRAND NAME : N/A MODEL NAME : KN2432LB, KN2432LB-A, KN2432 APPLICANT : Guangdong Welland Technology Co., Ltd. DATE OF ISSUE : Sep. 22, 2025 STANDARD(S) : FCC Part 15 Subpart C §15.247 REPORT VERSION : V1.0 Attestation Of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC06164250901FR01 Page 2 of 49 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Sep. 22, 2025 Valid Initial Release Report No.: AGC06164250901FR01 Page 3 of 49 Table of Contents 1. General Information ........................................................................................................................................ 5 2. Product Information ........................................................................................................................................ 6 2.1 Product Technical Description ................................................................................................................... 6 2.2 Test Frequency List ................................................................................................................................... 6 2.3 Related Submittal(S) / Grant (S) ............................................................................................................... 7 2.4 Test Methodology ...................................................................................................................................... 7 2.5 Special Accessories .................................................................................................................................. 7 2.6 Equipment Modifications ........................................................................................................................... 7 2.7 Antenna Requirement................................................................................................................................ 7 3. Test Environment ............................................................................................................................................ 8 3.1 Address of the Test Laboratory ................................................................................................................. 8 3.2 Test Facility ................................................................................................................................................ 8 3.3 Environmental Conditions ......................................................................................................................... 9 3.4 Measurement Uncertainty ......................................................................................................................... 9 3.5 List of Equipment Use ............................................................................................................................. 10 4.System Test Configuration ............................................................................................................................ 12 4.1 EUT Configuration ................................................................................................................................... 12 4.2 EUT Exercise ........................................................................................................................................... 12 4.3 Configuration of Tested System .............................................................................................................. 12 4.4 Equipment Used In Tested System ........................................................................................................ 13 4.5 Summary of Test Results ........................................................................................................................ 14 5. Description of Test Modes ........................................................................................................................... 15 6. Duty Cycle Measurement ............................................................................................................................. 16 7. RF Output Power Measurement .................................................................................................................. 17 7.1 Provisions Applicable .............................................................................................................................. 17 7.2 Measurement Procedure ......................................................................................................................... 17 7.3 Measurement Setup (Block Diagram of Configuration) .......................................................................... 17 7.4 Measurement Result ............................................................................................................................... 18 8. 6dB Bandwidth Measurement ...................................................................................................................... 21 8.1 Provisions Applicable .............................................................................................................................. 21 8.2 Measurement Procedure ......................................................................................................................... 21 8.3 Measurement Setup (Block Diagram of Configuration) .......................................................................... 21 8.4 Measurement Results ............................................................................................................................. 22 9. Power Spectral Density Measurement ........................................................................................................ 26 9.1 Provisions Applicable ....................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 RF:王志锋 TEL: 13823540870 TIME: 2019/11/09 Client: Guangdong Welland Technology Co., Ltd. Project: KN2432LB Antenna standard: BT Manufacturer Address:Building 8, Nanshan Yungu, Taoyuan Street, Nanshan District, Shenzhen, China Shenzhen DBT Telecommunication Technology CO.,LTD Antenna Testing Report Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 OTA-800 Brand:ETS Frequency range:370MHz-8.5GHz Features:passive、active test;G net、C net、 2G/3G/4G,WIFI and BT, TRP、TIS test. 1. Test Equipment 5071C Brand:Agilent Frequency range:9KHz-8.5GHz Features:2G/3G/4G/BT/WIFI antenna comprehensive passive test。 8960 Brand:Agilent Frequency range:292MHz-2700GHz Features:2G/3G avtive test。 CMW500 Brand:Rohde & Schwarz Frequency range:70KHz-6GHz Features:2G/3G/4G/BT/WIFI/NB-Lot antenna comprehensive passive test。 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 2. Matching circuit Antenna RF Module E1 E2 E3 E4 Element MAIN GPS/WIFI /BT AUX E1(0201) N/A E2(0201) 3.3nF E3(0201) 1.5pF E4(0201) 0Ω Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 3.Antenna assembly position antenna position antenna position Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 Electrical Parameter Frequency Range (MHz) 2400~2500 VSWR ≤7.0 Input Impedance(Ω) 50 Gain(dBi) 0.88 Polarization(°) vertical Max power(W) 10 Antenna Type PCB Antenna Working Temperature(°C) -40~+80 4.Electrical Parameter Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 5.Antenna Passive Data Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 6.Antenna Gain/Efficiency/3D Apple Chart Freq Effi Gain (MHz) (%) (dBi) 2400 1.6 0.88 2410 1.36 0.87 2420 1.77 0.86 2430 1.45 0.85 2440 1.42 0.79 2450 1.18 0.76 2460 1.63 0.77 2470 1.01 0.76 2480 1 0.69 2490 0.73 0.61 2500 1.42 0.66 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 7.Antenna Direction Map

Test Setup Photos

Report No.: AGC06164250901AP02 Page 1 of 2 TEST SETUP PHOTOS RADIATED EMISSION TEST SETUP BELOW 1GHz RADIATED EMISSION TEST SETUP ABOVE 1GHz Report No.: AGC06164250901AP02 Page 2 of 2 RF CONDUCTED TEST SETUP ****************************************End of Report*************************************

Contact Information

Applicant

Hillary Chan(Sales Manager)
[email protected]Fax: 0760-28160370

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz900.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Guangdong Welland Technology Co., Ltd.

2AP3Q-FG2415WB

Smart Scale

Jul 24, 2026

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2AP3Q-FG2504WB-A - Guangdong Welland Technology Co., Ltd.
2AP3Q-FG2504WB-A

Smart Body Fat Scale

Apr 29, 2026

Equipment Class

DTS - Digital Transmission System
Kitchen scale - FCC ID 2AP3Q-KG2458ULB - Guangdong Welland Technology Co., Ltd.
2AP3Q-KG2458ULB

Kitchen scale

Apr 21, 2026

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2AP3Q-FG450WB-A - Guangdong Welland Technology Co., Ltd.
2AP3Q-FG450WB-A

Smart Body Fat Scale

Apr 21, 2026

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID 2AP3Q-FI2502ULB - Guangdong Welland Technology Co., Ltd.
2AP3Q-FI2502ULB

Smart Body Fat Scale

Mar 09, 2026

Equipment Class

DTS - Digital Transmission System