Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
尺寸:60x90mm 90° 300° 155mm 72mm 17mm 3 in 1 Magnetic Wireless Charger User Manual Product ParameterHow to UseAttention Do not disassemble the device. Please make sure your device is Qi-compatible or has a Qi receiver kit (not included). Your phone should be MagSafe compatible or equipped with a magnetic plate or phone case in order to achive the magnetic charging effect. (such as a magnetic protective case). A Quick Charger adapter and cable are required for the fast wireless charging features. (Power adapter is sold separately) Do not use or store the magnetic wireless charger in a hot or humid environment as it may damage the circuit. A magnet may interfere with the magnetic charging of the product or cause malfunctions; To avoid interference between. other devices and products, please keep magnetic chip cards (such as ID cards, credit cards) or medical devices (such as pacemakers,defibrillators, hearing aids, etc.) away from the product.Keep a distance of at least 20 cm from the product, and more than 30 cm during wireless charging. LED Indicator Status · Power on -- Both indicators flash 3 times quickly and then go out. · Standby mode -- Both indicators go out. · Charging 1 device -- Both indicators are on simultaneously . · Charging 2 devices -- Both indicators are on simultaneously. · Charging 1 devices but paused due to a foreign object detected -- Both indicators flash. · One device charging,the other paused due to a foreign object detected.(Please remove the object to continue charging.) -- One light is on, the other light flashes. 1. Connect to a power adapter. 2. Attach your iPhone 12/13/14 to the top magnetic pad, and place your Charge your phone, Apple Watch, AirPods. Type-C interface Mobile Phone 15W Magnetic fast Charging Airpods iWatch 说明书 三合一磁性无线充电座 90° 300° 155mm 72mm 17mm 产品参数:使用方法:注意: 请勿私自拆卸设备。 确保您的设备支持Qi无线充电协议或安装符合Qi标准的无线接 收器(不包含在内)。 要实现手机吸附充电,请确保手机设备带有磁吸功能,或配有 磁吸配件(如:磁吸保护壳)。 要达到快充,需要使用支持快充的适配器和充电线。 请勿在高温或者潮湿的环境下使用或存放该磁吸无线充。 磁铁可能会干扰产品的磁吸充电或导致故障;为避免其他设备 和产品互相干扰,请将磁性芯片卡(例如D卡,信用卡)或医疗 设备(例如心脏起搏器,除颤器,助听器等)与产品保持至少 20cm的距离,无线充电时30cm以上。 指示灯状态 ·通电- 两个指示灯整体快闪3次后熄灭。 ·待机状态- 两个指示灯全部熄灭。 ·单独充一个设备- 只有对应的灯亮,另外一个是灭灯状态。 ·同时充两台设备- 两个指示灯整体全亮。 ·充一台设备且有异物,FOD保护-两个指示灯整体快闪。 ·一台设备正常充电,另一台设备FOD保护-一个灯常亮,另 一个灯快闪。 FOD-异物检测 ·充一台设备且有异物,FOD保护一两个指示灯整体快闪。 ·一台设备正常充电,另一台设备FOD保护一一个灯常亮,另 一个灯快闪。 1.连接电源。 2.给手机、Apple watch、AirPods充电。 Type-C充电接口 手机充电位 15W快充 带磁吸 耳机充电位 手表充电位 FCC Statement This device complies with part 15 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could void the user's authority to operate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and candidate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected.
DONGGUAN CHUANGLONG ELECTRONICS LIMITED Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 8/16/2023 U.S. Agent Designation DON GGUAN CHUANGLONG ELECTRONICS LIMITED acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2APCQ-A01): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of DONGGUAN CHUANGLONG ELECTRONICS LIMITED. DONGGUAN CHUANGLONG ELECTRONICS LIMITED with the FRN 0027380930 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Since rely, Signature AnZhang Liao President DONGGUAN CHUANGLONG ELECTRONICS LIMITED Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05
Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address: King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Phone: +86-769-82098608 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-08-07 Signature Date Printed Name of Signee: Anzhang Liao Company: DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address: King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Phone: +86-769-82098608 Fax: +86-769-82995889 Email: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2APCQ-A01 A01 We, applicant Company Name: DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address: King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Phone: +86-769-82098608 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-08-07 Signature Date Printed Name of Signee: Anzhang Liao Company: DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address: King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Phone: +86-769-82098608 Fax: +86-769-82995889 Email: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2APCQ-A01 A01 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Parts Lists • the Tune Up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-08-07 Signature Date Printed Name of Signee: Anzhang Liao Company: DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address: King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Phone: +86-769-82098608 Fax: +86-769-82995889 Email: [email protected]
DONGGUAN CHUANGLONG ELECTRONICS LIMITED King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Date: August 07, 2023 FCC ID: 2APCQ-A01 Model Number: A01 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, DONGGUAN CHUANGLONG ELECTRONICS LIMITED hereby declare that our product (3 in 1 wireless charging station) Model Number: A01 meet item 5.2 of KDB 680106v03r01 as follow; Requirements of KDB 680106 D01 Yes / No Description Power transfer frequency is less than 1 MHz Yes The device operate in the frequency range is 110.3 KHz – 205 KHz Output power from each primary coil is less than or equal to 15 watts. Yes The device supports 3 primary coils, the maximum output power of the primary coil is 15W The system may consist of more than one source primary coils, charging one or more clients. If more than one primary coil is present, the coil pairs may be powered on at the same time. Yes Charging systems supports 3 primary coils and clients that are able to detect and allow coupling only between individual pairs of coils and the coils pairs power on at the same time. Client device is placed directly in contact with the transmitter. Yes Client device is placed directly in contact with the transmitter Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Yes Mobile exposure condition only The aggregate H-field strengths anywhere at or beyond 15 cm surrounding the device, and 20 cm away from the surface from all coils that by design can simultaneously transmit, and while those coils are simultaneously energized, are demonstrated to be less than 50% of the applicable MPE limit. Yes The EUT H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Please contact me if you have any question. DONGGUAN CHUANGLONG ELECTRONICS LIMITED King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Sincerely, (Signed) Name/Title: Anzhang Liao / President Company: DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address: King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Tel: +86-769-82098608 Fax: +86-769-82995889 E-Mail: [email protected]
Page 1 of 6 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 6 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 6 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 6 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 6 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 6 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12
Page 1 of 1 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 4.0cm x W: 2.5cm) Label Location 3 in 1 Magnetic Wireless Charger Model: A01 FCC ID: 2APCQ-A01
Page 1 of 2 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Phone Coil Antenna Airpods Coil Antenna iWatch Coil Antenna Page 2 of 2 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4
Page 1 of 11 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report 1. Product Information FCC ID: 2APCQ-A01 Number of tested samples 2 Sample number A061923098-1(Engineer sample), A061923098-2(Normal sample) Product Name 3 in 1 Magnetic Wireless Charger Model Number A01 Power Supply Input:5V-9V2.2A(Max) For AC Adapter Model: Q5003-US Input: 100-240V~, 50/60Hz, 0.5A Max Output: 3.6-6V3A, 6-9V2A, 9-12V1.5A Wireless charge output: Phone:15W, apple watch: 5W, airpods:3W Modulation Type Continuous Wave Frequency Range 110.3~205.0KHz Antenna Type Coil Antenna Hardware version V01 Software version V02 Accessories / Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 15 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. Page 2 of 11 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices Page 3 of 11 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field St…
Text truncated - open the document above for the full version.
Dongguan Chuangjie Electronics Co. Ltd Supplier company name:Dongguan Chuangjie Electronics Co. Ltd supplier name: Coil Antenna Modle: A01 supplier address:No.8 Jinxing Road, Jinfenghuang,Fenggang Town,Dongguan city, Guangdong, China Gain: 0dBi(Max.) Phone Coil Antenna Airpods Coil Antenna All measurements were performed radiated and therefore additional antenna gain documentation is not required. Dongguan Chuangjie Electronics Co. Ltd Phone Coil Antenna& Airpods Coil Antenna: iWatch Coil Antenna Dongguan Chuangjie Electronics Co. Ltd iWatch Coil Antenna:
Page 1 of 25 FCC ID: 2APCQ-A01 Report No.: LCSA061923098EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For DONGGUAN CHUANGLONG ELECTRONICS LIMITED 3 in 1 Magnetic Wireless Charger Test Model: A01 Prepared for : DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address : King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 20, 2023 Number of tested samples : 2 Serial number : A061923098-1(Engineer sample), A061923098-2(Normal sample) Date of Test : June 20, 2023 ~ July 08, 2023 Date of Report : July 08, 2023 Page 2 of 25 FCC ID: 2APCQ-A01 Report No.: LCSA061923098EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15C Report Reference No. ................. : LCSA061923098EA Date Of Issue ................................. : July 08, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address .......................................... : King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Test Specification Standard ......................................... : FCC CFR 47 PART 15C Test Report Form No...................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : 3 in 1 Magnetic Wireless Charger Trade Mark ..................................... : N/A Test Model ...................................... : A01 Power Supply ................................. : Input:5V-9V2.2A(Max) For AC Adapter Model: Q5003-US Input: 100-240V~, 50/60Hz, 0.5A Max Output: 3.6-6V3A, 6-9V2A, 9-12V1.5A Wireless charge output: Phone:15W, apple watch: 5W, airpods:3W Result ........................................... : Positive Compiled by: Supervised by: Approved by: Kay Hu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 25 FCC ID: 2APCQ-A01 Report No.: LCSA061923098EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA061923098EA July 08, 2023 Date of issue Test Model.............................. : A01 EUT......................................... : 3 in 1 Magnetic Wireless Charger Applicant............................... : DONGGUAN CHUANGLONG ELECTRONICS LIMITED Address.................................. : King Long industrial district, xiekeng village, qingxi town, Dongguan city, Guangdong, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Dongguan Chuangjie Electronics Co. Ltd Address................................... : No.8 Jinxing Road, Jinfenghuang,Fenggang Town,Dongguan city, Guangdong, China Telephone............................... : / Fax.......................................... : / Factory................................... : Dongguan Chuangjie Electronics Co. Ltd Address................................... : No.8 Jinxing Road, Jinfenghuang,Fenggang Town,Dongguan city, Guangdong, China Telephone............................... : / Fax.......................................... : / Page 4 of 25 FCC ID: 2APCQ-A01 Report No.: LCSA061923098EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 July 08, 2023 Initial Issue -- Page 5 of 25 FCC ID: 2APCQ-A01 Report No.: LCSA061923098EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, Chi…
Text truncated - open the document above for the full version.
Page 1 of 2 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Photographs of Test Setup Conducted Emission-AC adapter charge mode Radiated Emission below 30MHz-AC adapter charge mode Page 2 of 2 FCC ID: 2APCQ-A01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Radiated Emission below 1GHz-AC adapter charge mode
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1103 MHz - 0.205 MHz | - |

3 in 1 wireless charging station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Fast Wireless Charging Holder
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Car Fast Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz