FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
ShenZhen CuCo Smart Technology Co., Ltd. 2F, No.14, XinWuYuan Industrial Area, DiFu Road, GuShu, Xixiang Town, Bao’an District, Shenzhen, China ProductSimilarityDeclaration Date: January 4, 2020 FCC ID:2APUZ-P2 Model Number: P2,PM03, PM02, PM01, WB2, WB4, LB1, LB2, P3, WO1, WO2 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, ShenZhen CuCo Smart Technology Co., Ltd. hereby declare that our product (smart multi plug outlet) Model Number:P2,PM03, PM02, PM01, WB2, WB4, LB1, LB2, P3, WO1, WO2 board, Schematic, Hardware version, Software version, structure and internal photos are same, named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name/Title:Lizs Dai / manager Company: ShenZhenCuCo Smart Technology Co., Ltd. Address: 2F, No.14, XinWuYuan Industrial Area, DiFu Road, GuShu, Xixiang Town, Bao’an District, Shenzhen, China Tel: 0755-86165826 Fax: 0755-86165825 E-Mail: [email protected]
C5266091_X8_Ed.1 1/1 Letter of Authorization ShenZhen CuCo Smart Technology Co., Ltd. Company: ShenZhen CuCo Smart Technology Co., Ltd. Address:2F, No.14, XinWuYuan Industrial Area, DiFu Road, GuShu, Xixiang Town, Bao’an District, Shenzhen, China Product Name:smart multi plug outlet Model Number:P2 FCC Identifier:2APUZ-P2 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name:Date: 2020-1-4 Title: manager Signature of applicant: ShenZhen CuCo Smart Technology Co., Ltd.
C5266091_X10_Ed.1 1/1 ShenZhen CuCo Smart Technology Co., Ltd. Date: 2020-1-4 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Confidentiality FCC ID:2APUZ-P2 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality ID Label/LocationNoNo Attestation StatementNoNo External PhotosNo Block Diagram Schematics Test ReportNoNo Test Setup PhotosNo User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s)NoNo SDR Software / Security InfoNo Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name:Lizs Dai Title: manager
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of3 ExternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of3 Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of3 Fig.5 Fig.6
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of1 LABELANDLOCATION Size:L2.0cm*W1.5cm LabelLocation smartmultiplugoutlet ModelNo.:P2 FCCID:2APUZ-P2
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of2 InternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of2 Fig.3 Fig.4 Antennna
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 3 MaximumPermissibleExposureReport 1.ProductInformation FCCID 2APUZ-P2 Productnamesmartmultiplugoutlet TestModelP2 AdditionalModelNo.PM03,PM02,PM01,WB2,WB4,LB1,LB2,P3,WO1,WO2 PowersupplyAC85~240V ModulationType IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaTypeInternalAntenna AntennaGain1dBi(Max.) HardwareversionV1.1 Softwareversion1.0.1 WLANFCCOperationFrequency IEEE802.11b:2412–2462MHz IEEE802.11g:2412–2462MHz IEEE802.11nHT20:2412–2462MHz ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensuresthatthe publicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobiledevicewhereby adistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelowRFPermissibleExposure limitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesumoftheMPE ratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthecalculated/estimated, numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPEratioofeachantennais determinedattheminimumtestseparationdistancerequiredbytheoperatingconfigurationsandexposureconditions ofthehostdevice,accordingtotheratiooffieldstrengthsorpowerdensitytoMPElimit,atthetestfrequency.Either themaximumpeakorspatiallyaveragedresultsfrommeasurementsornumericalsimulationsmaybeusedto determinetheMPEratios.SpatialaveragingdoesnotapplywhenMPEisestimatedusingsimplecalculationsbasedon far-fieldplane-waveequivalentconditions.Theantennainstallationandoperatingrequirementsforthehostdevice mustmeettheminimumtestseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneous transmissionoperations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequencyElectromagnetic Fields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRFExposure ProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 3 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation ZJ-MWIR-RGBcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Note AntennaInternalAntenna2.4G1dBiWLANAntenna 6.ConductedPower [2.4GWLAN] ModeChannelFrequency(MHz)PeakConductedOutputPower(dBm) IEEE802.11b 1241212.39 6243711.21 11246210.84 IEEE802.11g 1241216.15 6243715.59 11246215.19 IEEE802.11nHT20 1241216.07 6243715.28 11246214.96 7.ManufacturingTolerance SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 3 of 3 [2.4GWLAN] IEEE802.11b(Peak) ChannelChannel1Channel6Channel11 Target(dBm)12.0011.0011.00 Tolerance±(dB)1.01.01.0 IEEE802.11g(Peak) ChannelChannel1Channel6Channel11 Target(dBm)16.0016.0015.00 Tolerance±(dB)1.01.01.0 IEEE802.11nHT20(Peak) ChannelChannel1Channel6Channel11 Target(dBm)16.0015.0015.00 Tolerance±(dB)1.01.01.0 8.MeasurementResults 8.1StandaloneMPE AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromanybodypartof theuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparationdistance,r=20cm,as wellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensitycanbeobtained. [ Antenna] ModulationType OutputpowerAntenna Gain (dBi) Antenna Gain (linear) Duty Cycle MPE (mW/cm 2 ) MPE Limits (mW/cm 2 ) dBmmW IEEE802.11b13.0019.95261.00 1.2600 100% 0.0050 1.0000 IEEE802.11g17.0050.11871.001.2600100% 0.0126 1.0000 IEEE802.11nHT2017.0050.11871.001.2600100% 0.0126 1.0000 Remark: 1.Outputpowerincludingtune-uptolerance; 2.MPEevaluatedistanceis20cmfromusermanualprovidebymanufacturer; 8.2SimultaneousTransmissionMPE ThesamplesupportoneWLANmodularandoneantenna,noneedconsidersimultaneoustransmission; 9.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1091fortheuncontrolledRFExposureofmobile device. ----------------THEENDOFREPORT---------------
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of35 FCCTESTREPORT For ShenZhenCuCoSmartTechnologyCo.,Ltd. smartmultiplugoutlet ModelNo.:P2 AdditionalModelNo.:Pleaserefertopage6 Preparedfor:ShenZhenCuCoSmartTechnologyCo.,Ltd. Address: 2F,No.14,XinWuYuanIndustrialArea,DiFuRoad,GuShu,Xixiang Town,Bao’anDistrict,Shenzhen,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,601,XingyuanIndustrialPark,GushuCommunity,Xixiang Street,Bao’anDistrict,Shenzhen,Guangdong,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample: December02,2019 Numberoftestedsamples: 1 Serialnumber: Prototype DateofTest: December02,2019~December18,2019 DateofReport: December19,2019 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of35 FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCS191130001AEA DateofIssue.......................................:December19,2019 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,601,XingyuanIndustrialPark,GushuCommunity,Xixiang Street,Bao’anDistrict,Shenzhen,Guangdong,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ShenZhenCuCoSmartTechnologyCo.,Ltd. Address................................................: 2F,No.14,XinWuYuanIndustrialArea,DiFuRoad,GuShu,Xixiang Town,Bao’anDistrict,Shenzhen,China TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................: smartmultiplugoutlet TradeMark..........................................: Gosund Model/Typereference......................: P2 Ratings.................................................:Pleaserefertothepage6 Result...................................................:Positive Compiledby:Supervisedby:Approvedby: JerryZeng/Administrators JinWang/TechniqueprincipalGavinLiang/Manager SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of35 FCC--TESTREPORT EUT.........................................:smartmultiplugoutlet Type/Model...........................:P2 Applicant...............................:ShenZhenCuCoSmartTechnologyCo.,Ltd. Address..................................: 2F,No.14,XinWuYuanIndustrialArea,DiFuRoad,GuShu,Xixiang Town,Bao’anDistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenCucoSmartTechnologyCo.,Ltd Address...................................: Floor2to4,building6,fuzhongindustrialpark,huidecommunity,f uyongstreet,baoandistrict,shenzhen,China Telephone...............................: Fax..........................................: Factory...................................: / Address...................................: / Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCS191130001AEA December19,2019 Dateofissue SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of35 RevisionHistory RevisionIssueDateRevisionsRevisedBy 000December19,2019InitialIssueGavinLiang SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of35 TABLEOFCONTENTS 1.GENERALINFORMATION .................................................................................................................................................... 6 1.1.DESCRIPTIONOFDEVICE(EUT) ........................................................................................................................................ 6 1.2.HOSTSYSTEMCONFIGURATIONLISTANDDETAILS .......................................................................................................... 6 1.3.EXTERNALI/OCABLE .......................................................................................................................................................... 6 1.4.DESCRIPTIONOFTESTFACILITY ........................................................................................................................................ 7 1.5.STATEMENTOFTHEMEASUREMENTUNCERTAINTY .......................................................................................................... 7 1.6.MEASUREMENTUNCERTAINTY ........................................................................................................................................…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 1 of 40 Appendix C RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: smart multi plug outlet Trade Mark: Gosund Test Model: P2 Environmental Conditions Temperature: 22.6C Relative Humidity:52.8% ATM Pressure:100.0 kPa Test Engineer:Zhuo Zhuo Supervised by:Li Huan C.1 Duty Cycle Test ModeTest ChannelAntDuty Cycle[%]Verdict 11B2437Ant1100PASS 11G2437Ant1100PASS 11N20SISO2437Ant1100PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 2 of 40 Duty Cycle_11B_2437_Ant1 Duty Cycle_11G_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 3 of 40 Duty Cycle_11N20SISO_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 4 of 40 C.2 Maximum Conducted Output Power ModeChannelMeas.Level [dBm]Limit [dBm]Verdict 11B LCH12.3930PASS MCH11.2130PASS HCH10.8430PASS 11G LCH16.1530PASS MCH15.5930PASS HCH15.1930PASS 11N20SISO LCH16.0730PASS MCH15.2830PASS HCH14.9630PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 5 of 40 Test Graphs 11B/LCH 11B/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 6 of 40 11B/HCH 11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 7 of 40 11G/MCH 11G/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 8 of 40 11N20SISO/LCH 11N20SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 9 of 40 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 10 of 40 C.3 Maximum Power Spectral Density ModeChannelMeas.Level [dBm/30KHz]Limit [dBm/3KHz]Verdict 11B LCH-3.0498PASS MCH-3.9368PASS HCH-4.6308PASS 11G LCH-7.6168PASS MCH-8.1648PASS HCH-8.7728PASS 11N20SISO LCH-6.9728PASS MCH-7.7738PASS HCH-8.1878PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 11 of 40 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 12 of 40 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 13 of 40 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 14 of 40 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 15 of 40 C.4 6dB Bandwidth ModeChannel6dB Bandwidth [MHz]Limit [MHz]Verdict 11B LCH9.076 ≥0.5 PASS MCH8.102 ≥0.5 PASS HCH8.576 ≥0.5 PASS 11G LCH16.34 ≥0.5 PASS MCH16.35 ≥0.5 PASS HCH16.35 ≥0.5 PASS 11N20SISO LCH16.70 ≥0.5 PASS MCH16.68 ≥0.5 PASS HCH16.95 ≥0.5 PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 16 of 40 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 17 of 40 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 18 of 40 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 19 of 40 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 20 of 40 C.5 RF Conducted Spurious Emissions ModeChannelPref [dBm]Max. Level [dBm]Limit [dBm] Verdic t 11B LCH1.366-38.009-18.634PASS MCH0.117-37.510-19.883PASS HCH-0.319-37.772-20.319PASS 11G LCH-2.445-37.515-22.445PASS MCH-3.271-37.320-23.271PASS HCH-3.459-37.710-23.459PASS 11N20 SISO LCH-2.705-37.750-22.705PASS MCH-3.282-37.199-23.282PASS HCH-3.57-37.845-23.570PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 21 of 40 11B_LCH_Graphs Pref/11B/LCH Puw/11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 22 of 40 11B_MCH_Graphs Pref/11B/MCH Puw/11B/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 23 of 40 11B_HCH_Graphs Pref/11B/HCH Puw/11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 24 of 40 11G_LCH_Graphs Pref/11G/LCH Puw/11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 25 of 40 11G_MCH_Graphs Pref/11G/MCH Puw/11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 26 of 40 11G_HCH_Graphs Pref/11G/HCH Puw/11G/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 27 of 40 11N20SISO_LCH_Graphs Pref/11N20SIS O/LCH Puw/11N20 SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 28 of 40 11N20SISO_MCH_Graphs Pref/11N20 SISO/MCH Puw/11N20 SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 29 of 40 11N20SISO_HCH_Graphs Pref/11N20 SISO/HCH Puw/11N20 SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 30 of 40 C.6 Band-edge for RF Conducted Emissions ModeChannelCarrier Power[dBm] Max.Spurious Level [dBm] Limit [dBm]Verdict 11B LCH1.379-43.610-18.62PASS HCH-0.349-49.045-20.35PASS 11G LCH-2.549-43.608-22.55PASS HCH-3.345-44.124-23.35PASS 11N20SISO LCH-2.420-42.364-22.42PASS HCH-3.459-44.669-23.46PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 31 of 40 11B/HCH 11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2APUZ-P2Report No.: LCS191130001AEA Page 32 of 40 11G/HCH 11N20SISO/LC…
Text truncated - open the document above for the full version.
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of35 FCCTESTREPORT For ShenZhenCuCoSmartTechnologyCo.,Ltd. smartmultiplugoutlet ModelNo.:P2 AdditionalModelNo.:Pleaserefertopage6 Preparedfor:ShenZhenCuCoSmartTechnologyCo.,Ltd. Address: 2F,No.14,XinWuYuanIndustrialArea,DiFuRoad,GuShu,Xixiang Town,Bao’anDistrict,Shenzhen,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,601,XingyuanIndustrialPark,GushuCommunity,Xixiang Street,Bao’anDistrict,Shenzhen,Guangdong,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample: December02,2019 Numberoftestedsamples: 1 Serialnumber: Prototype DateofTest: December02,2019~December18,2019 DateofReport: December19,2019 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of35 FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCS191130001AEA DateofIssue.......................................:December19,2019 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,601,XingyuanIndustrialPark,GushuCommunity,Xixiang Street,Bao’anDistrict,Shenzhen,Guangdong,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ShenZhenCuCoSmartTechnologyCo.,Ltd. Address................................................: 2F,No.14,XinWuYuanIndustrialArea,DiFuRoad,GuShu,Xixiang Town,Bao’anDistrict,Shenzhen,China TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................: smartmultiplugoutlet TradeMark..........................................: Gosund Model/Typereference......................: P2 Ratings.................................................:Pleaserefertothepage6 Result...................................................:Positive Compiledby:Supervisedby:Approvedby: JerryZeng/Administrators JinWang/TechniqueprincipalGavinLiang/Manager SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of35 FCC--TESTREPORT EUT.........................................:smartmultiplugoutlet Type/Model...........................:P2 Applicant...............................:ShenZhenCuCoSmartTechnologyCo.,Ltd. Address..................................: 2F,No.14,XinWuYuanIndustrialArea,DiFuRoad,GuShu,Xixiang Town,Bao’anDistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenCucoSmartTechnologyCo.,Ltd Address...................................: Floor2to4,building6,fuzhongindustrialpark,huidecommunity,f uyongstreet,baoandistrict,shenzhen,China Telephone...............................: Fax..........................................: Factory...................................: / Address...................................: / Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCS191130001AEA December19,2019 Dateofissue SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of35 RevisionHistory RevisionIssueDateRevisionsRevisedBy 000December19,2019InitialIssueGavinLiang SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2APUZ-P2LCS191130001AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of35 TABLEOFCONTENTS 1.GENERALINFORMATION .................................................................................................................................................... 6 1.1.DESCRIPTIONOFDEVICE(EUT) ........................................................................................................................................ 6 1.2.HOSTSYSTEMCONFIGURATIONLISTANDDETAILS .......................................................................................................... 6 1.3.EXTERNALI/OCABLE ..............................…
Text truncated - open the document above for the full version.
Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 41.20 mW |

Z1-N module
Equipment Class
DTS - Digital Transmission System
Smart Switch
Equipment Class
DTS - Digital Transmission System
Smart Socket
Equipment Class
DTS - Digital Transmission System