FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PerimeterSafe Home Monitoring Limited/
  3. 2APVD-R100

2APVD-R100KODAK CHERISH Range Extender

PerimeterSafe Home Monitoring Limited
KODAK CHERISH Range Extender - FCC ID 2APVD-R100 - PerimeterSafe Home Monitoring Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 02, 2020
Application Purpose
Original Equipment
Date of Application
Apr 02, 2020
Equipment Note
KODAK CHERISH Range Extender
Frequency Range
2422.00000000 - 2452.00000000
Company
PerimeterSafe Home Monitoring Limited
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Industry Canada This device complies with Industry Canada license exempt RSS standard(s): Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. The term “IC:” before the certiication/registration number only signiies that the Industry Canada technical speciications were met. This product meets the applicable Industry Canada technical speciications. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. FCC Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Any changes or modiications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation. RF Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an un-controlled environment. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Cet émetteur doit être installé pour fournir une distance de séparation d’au moins 20cm de toute personne KODAK RANGE EXTENDER Quick Start Guide Guide de démarrage rapide minimum 16ft (5m) CHERISHCHERISHCHERISHCHERISHCHERISHCHERISHCHERISH KODAK Smart Home App or 1 2 Baby Series 3 4 5 6 Range Extender C220 C225 C525 C520 F670 F680 F685 The Kodak trademark, logo and trade dress are used under license from Kodak. Distributed and sold by © eBuyNow eCommerce Ltd. All other trademarks are the property of their respective owners.© 2020 eBuyNow eCommerce Ltd. All rights reserved. La marque, le logo et l'appellation commerciale Kodak sont utilisés sous licence de Kodak. Distribué et vendu par © eBuyNow eCommerce Ltd. Toutes les autres marques sont les propriété de leurs propriétaires respectifs. © 2020 eBuyNow eCommerce Ltd. Tous droits réservé. User Manuals and Support Guide d’utilisation et support

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Chain 0 Chain 1

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG200119008-00 Page 11 of 62 FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart 15.247(i)and subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4R² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: Frequency (MHz) Antenna Gain Conducted output power including Tune- up Tolerance Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric) (dBm)(mW) 2412-2462 42.51 27501.19 20.00 0.25 1.0 Result: The device meet FCC MPE at 20 cm distance

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View

Contact Information

Applicant

Alvin Wong
[email protected]85225869000Fax: 85226082840

Test Firm

Bay Area Compliance Laboratories Corp.(Dongguan)David Zhang
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.42 GHz - 2.45 GHz419.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

Other Applications from PerimeterSafe Home Monitoring Limited

Smart Baby Monitor - FCC ID 2APVD-C525PPU - PerimeterSafe Home Monitoring Limited
2APVD-C525PPU

Smart Baby Monitor

Jul 31, 2021

Equipment Class

DTS - Digital Transmission System
Smart Baby Monitor - FCC ID 2APVD-C525PBU - PerimeterSafe Home Monitoring Limited
2APVD-C525PBU

Smart Baby Monitor

Jul 31, 2021

Equipment Class

DTS - Digital Transmission System