FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD./
  3. 2AQJK-AST-WR070-1

2AQJK-AST-WR070-1Wireless Power Bank

NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD.
Wireless Power Bank - FCC ID 2AQJK-AST-WR070-1 - NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 12, 2020
Application Purpose
Original Equipment
Date of Application
Jan 12, 2020
Equipment Note
Wireless Power Bank
Frequency Range
0.11150000 - 0.20500000
Company
NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1.2.3.  ** MADE IN CHINA INSTRUCTIONS: Charging the Powerbank:Charge the powerbank fully before usage.Connect the provided charging cable to a power source and to the micro USB port on the powerbank(6). Or your own Type C cable to the Type Input Port (4). Once connected the LED Indicator will HITE when charging, once fully charged LED will turn WHITE.Charging mobile phones and other electronic devices:Connect the charging cable to your mobile phone/device using the appropriate connector. Connect the USB part of the cable into either USB Output(3 or 5). LED Indicator will illuminate when charging.Remove the USB cable from your mobile device when it is fully charged.Wireless Charging Function:Press the Powerbank ON/OFF button(7) to turn on the wireless charging function, LED indicator near power button will flash greenfor one time and turn on. Place wireless charging supported mobile device on the charging surface/suction pad, the green LED will be blinking flash when device is charging. Phone will begin to charge automatically. Note: When wireless charging, if the LED NOT a wireless charging device or there is an object between the device and charging surface interfering with the charging. Mare 8000 mAh Suction Wireless Power Bank Instruction Manual AST-WR070 1 x 8000 mAh Wireless Powerbank1 x USB to Micro-USB Cable1 x Instruction Manual Battery: 8000mAh/3.7V/29.6WhUSB Output 1/2: 5V/2A Max Wireless Output: 5W Type-C input: 5V/2A Micro-USB Input: 5V/2A ON/OFF Button: Press once to view the remaining power capacity. 1.2.3.4.5.6.7. 8.   Wireless Charging SurfaceSuction PadUSB Output 1Type-C Input PortUSB Output 2 Micro-USB Input PortON/OFF ButtonLED Indicators What’s included:Features: LED Indicators This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:This device may not cause harmful interference, andThis device must accept any interference received, including interference that may cause undesired operation.Warning: approved by the party responsible for compliance could void the user’s authority to operate the equipment. (1)(2)* F C C S t a t e m e n t : wireless charger, and lead to overheating. Please remove attachments from the phone before charging on this device. WARNING-When using this product, basic precautions should always be followed:Read all the instructions before use.Never store or use this product in temperatures below 32°F (0°C) or above 115°F (45°C). Do not overcharge your phone. The unit may become hot under excessive use. Remove your phone once it is fully charged. Never charge your phone for more than 7 hours at a time.The unit will only achieve full performance after 2 or 3 completed charge and discharge cycles. To reduce the risk of injury, close supervision is required when the product is used near children. Do not expose the device to moisture.Do not use the device in excess of its output rating. Overload outputs above the Do not use the device if damaged or explosion or risk of injury. Do not disassemble the device. For professional. Incorrect reassembly may or temperatures above 104°F (40°C) may result in explosion.To ensure product safety, ensure that identical replacement parts.Attachments on the back of your phone 1.2.3.4.5.6.7.8.9.10.11.12.13. SAFETY PRECAUTIONS: The distance between user and product should be no less than 20cm.

Cover Letter(s)

January 03, 2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AQJK- AST-WR070-1 Product Name: Wireless Power Bank Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential:  Schematics  Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Teresa Zhong Title:Sale Company:NINGBO ALLSTAR O&E TECHNOLOGY CO., LTD.

Cover Letter(s)

January 03, 2020 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China. (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD./ NO.19 HUIJIN ROAD,LUOTUO STREET,ZHENHAI, NINGBO, CHINA <Signature>: Name:Teresa Zhong Title:Sale Company:NINGBO ALLSTAR O&E TECHNOLOGY CO., LTD.

ID Label/Location Info

Label Location

ID Label/Location Info

43.5x61mm FCC ID: 2AQJK-AST-WR070-1 Item No.: AST-WR070 Input: DC5V-2A Output: DC5V-2A Wireless Output: DC5V-1A Capacity: 8000mAh 29.6Wh Made In China This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2AQJK-AST-WR070-1 Item No.: AST-WR070 Input: DC5V-2A Output: DC5V-2A Wireless Output: DC5V-1A Capacity: 8000mAh 29.6Wh Made In China This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Info

FCC ID: 2AQJK-AST-WR070-1 RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging App v03 And KDB Tracking Number 671578 ; TCB Workshop, October 2018, 5.2 RF Exposure Procedures 2 Requirements According to the item 5 of KDB 680106 D01 RF Exposure Wireless Charging App v03: (1)Power transfer frequency is less than 1 MHz. Yes,0.1115-0.205MHz (2)Output power from each primary coil is less than or equal to 15 watts. Yes, Max power 5W (3)The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes . (4) Client device is placed directly in contact with the transmitter. Yes (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). No (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Report No.: FCC1912231‐H Page 2 of 5 Date: 2019‐12‐30 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 3 Test Setup A: B: Report No.: FCC1912231‐H Page 3 of 5 Date: 2019‐12‐30 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 4 Test Procedure 1) The RF exposure test was performed in an echoic chamber; 2) The measurement probe was placed at test distance(15 cm from edges, 20 cm from top) Which is between the edge of the charger and the geometric center of probe, for test setup A; 3) In addition to what is described in KDB 680106 D01, please measure and provide magnetic and electrical field strength at a distance 10cm to 1cm at 1cm iteration, i.e. at a distance of 10cm, 9cm, 8cm, ....... 1cm. Which is between the edge of the charger and the edge of probe, for test setup B; 4) The highest emission level was recorded and compared with limit as soon as measurement of each points (A,B, C,D, E)were completed; 5) The EUT was measured according to the dictates of KDB680106D01v03; And KDB Tracking Number 671578 ; TCB Workshop, October 2018, 5.2 RF Exposure Procedures Remark:The EUT’ s test position A, B,C, D and E is valid for the E and H field measurements. 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) EMF Meter NARDA ELT-400 N-0356 Oct 11, 2019 Oct 10, 2020 EMF probe NARDA B-Field Probe M-0812 Oct 11, 2019 Oct 10, 2020 6 Test Result Test Result for Test setup A: Note: Frequency Range 0.1115-0.205 (MHz); <5%, 50 %,> 90% load all have been tested, Only worse case Max load (>90%) is reported. E-Filed Strength at (15 cm from edges A, B, C, D, 20 cm from top E) surrounding the EUT (V/m) Charging Load Worse case Test Position A(V/m) Test Position B(V/m) Test Position C(V/m) Test Position D(V/m) Test Position E(V/m) Limits (V/m) Max load 1.48 1.37 1.30 1.25 1.33 614 H-Filed Strength at (15 cm from edges A, B, C, D, 20 cm from top E) surrounding the EUT (A/m) Charging Load Worse case Test Position A(A/m) Test Position B(A/m) Test Position C(A/m) Test Position D(A/m) Test Position E(A/m) Limits (A/m) Max load 0.45 0.50 0.39 0.37 0.36 1.63 Report No.: FCC1912231‐H Page 4 of 5 Date: 2019‐12‐30 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves th…

Text truncated - open the document above for the full version.

Test Report

Report No.: FCC1912231 File Reference No.: 2019-12-30 Applicant: NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD Product: WIRELESS POWER BANK Model No.: AST-WR070 Trademark: N/A Test Standards: FCC Part 15 Subpart C Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 Subpart C, for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: December 30, 2019 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No: FCC1912231 Page 2 of 32 Date: 2019-12-30 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meets with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No: FCC1912231 Page 3 of 32 Date: 2019-12-30 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 5 1.5 Test Duration.................................................................................................... 5 1.6 Test Uncertainty................................................................................................. 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test...................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.................................................................................... 8 5.4 EUT Operating Condition..…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Te s t Setup: Radiated Emission Te s t Setup:

Contact Information

Applicant

Teresa Zhong
[email protected]0574-86307008Fax: 0574-86307001

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD.

Wireless Power Bank - FCC ID 2AQJK-AST-WR070-2 - NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD.
2AQJK-AST-WR070-2

Wireless Power Bank

Mar 26, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank - FCC ID 2AQJK-AST-WR115 - NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD.
2AQJK-AST-WR115

Wireless Power Bank

Mar 26, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank - FCC ID 2AQJK-AST-WR068-1 - NINGBO ALLSTAR O&E TECHNOLOGY CO.,LTD.
2AQJK-AST-WR068-1

Wireless Power Bank

Mar 26, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz