Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
NUBOMED X Series Intelligent Mobile Cart User Manual NuboMed ShenZhen · HeFei · California, USA NuboMed 19F,Block B, Building 12,Shenzhen Bay Science and Technology Eco-Park. NO.18,South Science and Technology Road, Nanshan, Shenzhen 2 Table of Content 1. Introduction of X Series Products ....................................................... 5 2. Product Specification ........................................................................... 6 2.1 Physical Structure .............................................................................. 6 2.2 Back End of the Desktop ................................................................... 8 2.3 Detail Specification ............................................................................ 9 3. Operating Instructions ...................................................................... 10 3.1 Power On/Off Instruction ............................................................... 10 3.2 Charging Instruction ....................................................................... 11 3.3 Power Display Panel ........................................................................ 13 3.4 Display Arm Angle Adjustment ...................................................... 14 3.5 Expandable Surface Instruction ..................................................... 16 3.6 Hidden Keyboard Tray Description ................................................ 16 3.7 Intelligent Medicine Module/Bins ................................................. 17 3.8 Caster Brake Instruction .................................................................. 18 3.9 Battery Release Instruction ............................................................. 19 4. Safety Precautions ............................................................................. 19 4.1 Service and Repair Instruction ....................................................... 19 4.2 Do NOT Disassemble Equipment ................................................... 20 4.3 Do not Dismantle Battery ............................................................... 20 NuboMed 19F,Block B, Building 12,Shenzhen Bay Science and Technology Eco-Park. NO.18,South Science and Technology Road, Nanshan, Shenzhen 3 4.4 Prevent Water Damage ................................................................... 20 4.5 Attention in Battery Maintenance .................................................. 20 4.6 Attention in Battery Use ................................................................. 20 4.7 Not in Use for Extensive Period ..................................................... 21 5. Initial Installation Instructions ......................................................... 21 6. Troubleshooting ................................................................................. 22 7. Cleaning Instructions ......................................................................... 24 NuboMed 19F,Block B, Building 12,Shenzhen Bay Science and Technology Eco-Park. NO.18,South Science and Technology Road, Nanshan, Shenzhen 4 Statement Thank you for purchasing the X Series Intelligent Mobile Cart by NuboMed. Before operating this product,please read this manual carefully. Special attention should be paid to for your safety. This general manual is suitable for all models of the X Series Intelligent Mobile Cart . Please use and maintain the equipment according to the instruction in this manual. Equipment repair can only be carried out by NuboMed personnel or its authorized service personnel. As the products are constantly updated, NuboMed retains the right to change the technical specifications without notice. If you feel that our equipment has room for improvement, or you have any comments or suggestions on our products, please feel free to share them with us at any time. We will answer your questions with the up most sincerity and resolve your problems as soon as possible. NuboMed October,2019 NuboMed 19F,Block B, Building 12,Shenzhen Bay Science and Technology Eco-Park. NO.18,South Science and Technology Road, Nanshan, Shenzhen 5 1. Introduction of X Series Products NuboMed's new X Series Intelligent Mobile Cart continues the tradition of S Series, and provides visible improvement for medical staff and clinical environment while focusing on different scenarios of clinical use. X Series is an era crossing product of Nursing 2.0 in the true sense. An all around nursing cart that achieves full closed-loop medication management, so that medical staff can embrace technology and return to the bedside. X Series is categorized into X1000, X2000, X3000, X4000, X5000, a total of five different models. NuboMed 19F,Block B, Building 12,Shenzhen Bay Science and Technology Eco-Park. NO.18,South Science and Technology Road, Nanshan, Shenzhen 6 2. Product Specification 2.1 Physical Structure X1000 Mobile Cart: X2000 Mobile Lite Cart : Rear Handle Front Handle 1U Drawer with Lock Table Top Sharp Object Box Bracket Hand Sterilizer Bracket Large Basket Step Pedal Trash Can Noise Free Casters with Lock Brake Tablet Computer Tablet Computer Arm Sharp Object Box Bracket Rear Handle 1U Drawer with Lock Front Handle Hand Sterilizer Bracket Large Basket Noise Free Casters with Lock Brake Step Pedal Trash Can NuboMed 19F,Block B, Building 12,Shenzhen Bay Science and Technology Eco-Park. NO.18,South Science and Technology Road, Nanshan, Shenzhen 7 X3000 Mobile Lite Cart: X4000 Advanced Mobile Cart: 21.5 inch HD LED Display Display Arm with Patent Certificate Double Columns Main Battery Side Drawers Front Glove Box Front Handle Rear Handle Noise Free Casters with Lock Brake Maximum Six 1U Drawers with Various Combinations Display Arm with Patent Certificate Table Top Sharp Object Box Bracket Noise Free Casters with Lock Brake 21.5 inch HD LED Display Rear Handle Front Handle Hand Sterilizer Bracket Step Pedal Trash Can Step Pedal Trash Can NuboMed 19F,Block B, Building 12,Shenzhen Bay Science and Technology Eco-Park. NO.18,South Science and …
Text truncated - open the document above for the full version.
FCC ID Label Information 1. Label location: 2. FCC ID Label: FCC ID:2AQK4X5000 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCCID Label Location
WIFI Antenna 1 WIFI Antenna 2
version01 Shenzhen NuboMed Technology co., Ltd. Tangtou 1st Rd., Skyworth Innovation Valley #5, Building C, 6F, Shiyan, Baoan, Shenzhen, China Tel: (86) 13826514464 Fax: 400-6251818 ext. 797 Declaration concerning Antenna Specification It is hereby declared that the product Model No.: X5000, Xxxxx (“x”=0~9) FCC ID: 2AQK4X5000 fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for internal antenna type(s) described below: Model No. of antenna: X5000 Type of antenna: PIFA antenna (2*2 MIMO) Gain of the antenna: 1dBi Frequency range: 2412~2462 MHz The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: Shenzhen NuboMed Technology co., Ltd. Address: Tangtou 1st Rd., Skyworth Innovation Valley #5, Building C, 6F, Shiyan, Baoan, Shenzhen, China City: Shenzhen ZIP / Postal code: Country: China Place: Shenzhen Date: 2019-01-09 Signature:
RF Exposure evaluation FCC ID:2AQK4X5000 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna is 1dBi, the RF power density can be obtained. WIFI Mode Max. Output Power (dBm) Max. Output Power (mW) Antenna Gain (Numeric) Power Density At 20 cm (mW/cm 2 ) Power Density Limit FCC (mW/cm 2 ) Test Results 802.11n40(MIMO) 20.66 116.4126 1.2589 0.0292 1 PASS 5. Conclusion The SAR evaluation is not required.
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC PART 15 SUBPART C 15.247 Report Reference No. ................. : CTL1910283021-WF Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Nice Nong (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name .............................. : Intelligent Mobile Cart Model/Type reference ................. : X5000 List Model(s) ................................ : Xxxxx (“x”=0~9) Brand Name ................................. : NuboMed FCC ID .......................................... : 2AQK4X5000 Applicant’s name ........................ : Shenzhen NuboMed Technology co., Ltd. Address of applicant .................. : Tangtou 1st Rd., Skyworth Innovation Valley #5, Building C, 6F, Shiyan, Baoan, Shenzhen, China Test Firm ...................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm .................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ........................ : Standard ........................................ : 47 CFR FCC Part 15 Subpart C 15.247 TRF Originator .............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF ................................... : Dated 2011-01 Date of receipt of test item ......... : Nov. 01, 2019 Date of sampling ......................... : Nov. 01, 2019 Date of Test Date ......................... : Nov. 01, 2019–Dec. 25, 2019 Data of Issue ................................ : Dec. 26, 2019 Result ........................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 48 Report No.: CTL1910283021-WF TEST REPORT Test Report No. : CTL1910283021-WF Dec. 26, 2019 Date of issue Equipment under Test : Intelligent Mobile Cart Model /Type : X5000 Listed Models : Xxxxx (“x”=0~9) Applicant : Shenzhen NuboMed Technology co., Ltd. Address : Tangtou 1st Rd., Skyworth Innovation Valley #5, Building C, 6F, Shiyan, Baoan, Shenzhen, China Manufacturer : Shenzhen NuboMed Technology co., Ltd. Address : Tangtou 1st Rd., Skyworth Innovation Valley #5, Building C, 6F, Shiyan, Baoan, Shenzhen, China Test result Pass * * In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 48 Report No.: CTL1910283021-WF ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release2019-12-26 CTL1910283021-WF Tracy Qi V1.0 Page 4 of 48 Report No.: CTL1910283021-WF Table of Contents Page 1. SUMMARY............................................................................................................................................................ 5 1.1. TEST STANDARDS ..................................................................................................................................................... 5 1.2. TEST DESCRIPTION ........................................................................................................................................................ 5 1.3. TEST FACILITY .............................................................................................................................................................. 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6 1.5. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 8 1.6. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 8 2. DESCRIPTION OF TEST MODES AND TEST FREQUENCY ........................................................................................... 8 2.1. EQUIPMENTS USED DURING THE TEST ............................................................................................................................ 10 2.2. RELATED SUBMITTAL(S) / GRANT (S) .............................................................................................................................. 10 2.3. MODIFICATIONS ......................................................................................................................................................... 10 3. TEST CONDITIONS AND RESULTS ......................................................................................................................... 11 3.1. CONDUCTED EMISSIONS TEST ....................................................................................................................................... 11 3.2. RADIATED EMISSIONS AND BAND EDGE .......................................................................................................................... 14 3.3. MAXIMUM CONDUCTED OUTPUT POWER ....................................................................................................................... 21 3.4. POWER SPECTRAL DENSITY .......................................................................................................................................... 22…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 116.42 mW |

Intelligent Management System
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter