Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter
Date of Grant
Jul 05, 2026
Application Purpose
Original Equipment
Equipment Note
TOW WAY RADIO
Frequency Range
462.56250000 - 462.57500000
Company
Shenzhen Todakj Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen Todakj Co., Ltd. Address:2nd Floor, Xinshidai Stationery Factory Building,Tiegang Community Xixiang Subdistrict,Bao'an District, Shenzhen, Guangdong Province,China Date: 2026-04-02 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(7) Filing SUBJECT: FCC Application for FCC ID: 2AQQS-E02 FRN: 0027727668 Shenzhen Todakj Co., Ltd. certifies that, as of the date of the filing of the application, Opuor INC is our designated U.S. agent for service of process for the above referenced FCC ID.Shenzhen Todakj Co., Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. Opuor INC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Opuor INC Address: 6510 S Academy Blvd Ste A 642 Colorado Springs, CO 80906 United States FRN:0036496966 Contact Person:Shuiqing Yang Tel.: (650) 315-6698 Email: [email protected] Sincerely, Signed on behalf of Shenzhen Todakj Co., Ltd. Signed on behalf of Opuor INC Name: Li Huang Name: Shuiqing Yang Title: Manager Title: Manager Date: 2026-04-02 Date: 2026-04-02

Attestation Statements

Rev1/26/2023 ShenzhenTodakjCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-04-20 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AQQS-E02 ShenzhenTodakjCo.,Ltd.certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. ShenzhenTodakjCo.,Ltd.certifiesthattheequipmentforwhichauthorizationissoughtdoesnotinclude cybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessors andassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446D01Covered EquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature) LiHuang Rev1/26/2023 ShenzhenTodakjCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-04-20 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AQQS-E02 ShenzhenTodakjCo.,Ltd.certifiesthat,asofthedateofthefilingoftheapplication,theapplicantisnot identifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesoraffiliates)asan entityproducing“covered”equipment. Sincerely, (Applicantsignature) LiHuang

Cover Letter(s)

ShenzhenTodakjCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:April9,2026 Subject;RequestforConfidentiality FCCID:2AQQS-E02 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. ☑SchematicDiagram ☑BlockDiagram ☑PartsList ☑OperationalDescription ☑Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos ☑UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR ☑For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:HuangLi Title:Manager

Cover Letter(s)

ShenzhenTodakjCo.,Ltd. Date:2026.4.14 ProductModelNumber:E02 FCCID:2AQQS-E02 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C.CanadaV5J5K5to actonourbehalfonallmattersconcerningtheabovenamedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformationrelatedtothe approvalprojecttotheappliedcertificationbodyandtothenotificationentitiesandtodiscuss anyissuesconcerningtheapprovalapplication.AnyandallactscarriedoutbyQAI LaboratoriesLtd.onourbehalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+0755-26588927 Onbehalfof:ShenzhenTodakjCo.,Ltd.

External Photos

FCCID:2AQQS-E02 ExternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2AQQS-E02 Fig.3 Fig.4 FCCID:2AQQS-E02 Fig.5 Fig.6 FCCID:2AQQS-E02 Fig.7

ID Label/Location Info

FCCID:2AQQS-E02 LabelandLocation Size:L:29.5mm*W:19.5mm LabelandLocation FCCID:2AQQS-E02

Internal Photos

FCCID:2AQQS-E02 InternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2AQQS-E02 Fig.3 Fig.4 Antenna FCCID:2AQQS-E02 Fig.5

RF Exposure Info

Page 3 of 67 Report No.: AiTSZ-260208051FW1 ※ ※ Revision History ※ ※ REV.DESCRIPTIONISSUED DATEREMARK Rev.1.0Initial Test Report ReleaseMar. 15, 2026Jack Li Page 4 of 67 Report No.: AiTSZ-260208051FW1 TABLE OF CONTENTS 1.General Information............................................................................................6 1.1.RF exposure limits....................................................................................6 1.2.Statement of Compliance........................................................................7 1.3.EUT Description.......................................................................................8 1.4.Test specification(s)..................................................................................8 1.5.Ambient Condition...................................................................................8 1.6.Test Facility...............................................................................................9 2.SAR Measurement System.................................................................................10 2.1.SATIMO SAR Measurement Set-up Diagram.........................................10 2.2.Robot.....................................................................................................11 2.3.Probe......................................................................................................12 2.3.1.E-Field Probe Calibration.................................................................12 2.4.Phantoms...............................................................................................13 2.5.Technical Data........................................................................................14 2.6.Device Holder.........................................................................................15 2.7.Test Equipment List................................................................................17 3.SAR Measurement Procedures..........................................................................20 3.1.Power Reference....................................................................................20 3.2.Area scan & Zoom scan..........................................................................20 3.3.Description of interpolation/extrapolation scheme..............................21 3.4.Volumetric Scan.....................................................................................22 3.5.Power Drift.............................................................................................22 4.System Verification Procedure...........................................................................23 4.1.Tissue Verification..................................................................................23 4.1.1.Tissue Dielectric Parameter Check Results......................................24 4.2.System Verification Procedure..............................................................25 4.2.1.System Verification Results.............................................................26 5.SAR measurement variabilit...............................................................................27 6.SAR Measurement Uncertainty.........................................................................28 7.RF Exposure Positions........................................................................................31 7.1.Generic device.......................................................................................31 8.RF Output Power................................................................................................32 8.1.Walkie Talkie Output Power..................................................................32 9.Antenna Location...............................................................................................33 10.Duty Cycle.......................................................................................................34 11.SAR Measurement Results..............................................................................35 Appendix A. Photo documentation..........................................................................36 Appendix B. System Check Plots..............................................................................37 Appendix C. SAR Test Plots.......................................................................................40 Page 5 of 67 Report No.: AiTSZ-260208051FW1 Appendix D. Calibration Certificate..........................................................................45 Page 6 of 67 Report No.: AiTSZ-260208051FW1 1.General Information 1.1.RF exposure limits (A).Limits for Occupational/Controlled Exposure (W/kg) Whole-BodyPartial-BodyHands, Wrists, Feet and Ankles 0.48.020.0 (B).Limits for General Population/Uncontrolled Exposure (W/kg) Whole-BodyPartial-BodyHands, Wrists, Feet and Ankles 0.081.64.0 NOTE: Whole-Body SAR is averaged over the entire body, partial-body SAR is averaged over any 1 gram of tissue defined as a tissue volume in the shape of a cube. SAR for hands, wrists, feet and ankles is averaged over any 10 grams of tissue defined as a tissue volume in the shape of a cube. Occupational/Controlled Environments: Are defined as locations where there is exposure that may be incurred by people who are aware of the potential for exposure, (i.e. as a result of employment or occupation). General Population/Uncontrolled Environments: Are defined as locations where there is the exposure of individuals who have no knowledge or control of their exposure. NOTE TRUNK LIMIT 1.6 W/kg APPLIED TO THIS EUT Page 7 of 67 Report No.: AiTSZ-260208051FW1 1.2.Statement of Compliance The maximum results of Specific Absorption Rate (SAR) found during testing as follows. Max SAR Value Reported(W/kg) Band 1-g Front of face (Separation distance of 25mm) 1-g Body worn (Separation distance of 0mm) Walkie Talkie0.6460.852 NOTE:This device is compliance with Specific Absorption Rate (SAR) for General Population/Uncontrolled Expos


Text truncated - open the document above for the full version.

RF Exposure Info

Page 45 of 67 Report No.: AiTSZ-260208051FW1 Appendix D. Calibration Certificate Table of contents E Field Probe - SN 31/17 EPGO324 450 MHz Dipole - SN 38/18 DIP 0G450-465 Page 46 of 67 Report No.: AiTSZ-260208051FW1 Page 47 of 67 Report No.: AiTSZ-260208051FW1 Page 48 of 67 Report No.: AiTSZ-260208051FW1 Page 49 of 67 Report No.: AiTSZ-260208051FW1 Page 50 of 67 Report No.: AiTSZ-260208051FW1 Page 51 of 67 Report No.: AiTSZ-260208051FW1 Page 52 of 67 Report No.: AiTSZ-260208051FW1 Page 53 of 67 Report No.: AiTSZ-260208051FW1 Page 54 of 67 Report No.: AiTSZ-260208051FW1 Page 55 of 67 Report No.: AiTSZ-260208051FW1 Page 56 of 67 Report No.: AiTSZ-260208051FW1 Page 57 of 67 Report No.: AiTSZ-260208051FW1 Page 58 of 67 Report No.: AiTSZ-260208051FW1 Page 59 of 67 Report No.: AiTSZ-260208051FW1 Page 60 of 67 Report No.: AiTSZ-260208051FW1 Page 61 of 67 Report No.: AiTSZ-260208051FW1 Page 62 of 67 Report No.: AiTSZ-260208051FW1 Page 63 of 67 Report No.: AiTSZ-260208051FW1 Page 64 of 67 Report No.: AiTSZ-260208051FW1 Page 65 of 67 Report No.: AiTSZ-260208051FW1 Page 66 of 67 Report No.: AiTSZ-260208051FW1 Page 67 of 67 Report No.: AiTSZ-260208051FW1 Appendix E. Justification of the extended calibration Referring to KDB 865664 D01, if dipoles are verified in retum loss(< -20dB, within 20% of prior calibration), and inimpedance(within S ohm of prior calibration), the annual calibration is not necessary and the calibration interval canbe extended. <Head 450MHz> Return Loss (dB) Delta (%)ImpedanceDelta(ohm) Date of Measurement -25.95-45.0-Feb. 21, 2025 -26.25-1.1645.870.87Feb. 20, 2026 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. ※※END OF THE REPORT※※ ※※END OF THE REPORT※※

Test Report

ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China TESTREPORT FCCPart95 ReportReferenceNo. ....................... : FCCID. ................................................. : GRCTR260102045-01 2AQQS-E02 Compiledby (position+printedname+signature).: TestingEngineerJimmyWang Supervisedby (position+printedname+signature) . : ProjectEngineerKelleyZhang Approvedby (position+printedname+signature) . : ManagerZhiHuiDeng Dateofissue ......................................... :May.28,2026 TestingLaboratoryName................:ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address.................................................: 101#,BuildingK&BuildingT,TheSecondIndustrialZone,Jiazitang Community,FenghuangStreet,GuangmingDistrict,Shenzhen,China Applicant’sname ............................... : ShenzhenTodakjCo.Ltd. Address.................................................: 2ndFloor,XinshidaiStationeryFactoryBuilding,Tiegang Community,XixiangSubdistrict,Bao'anDistrict,Shenzhen,Guangdong Province,China Testspecification ............................... : Standard................................................: FCCCFRTitle47Part95B ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerand sourceofthematerial.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesno responsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthe reproducedmaterialduetoitsplacementandcontext. Testitemdescription........................: TOWWAYRADIO TradeMark ............................................ : / Manufacturer.......................................: ShenzhenTodakjCo.Ltd. Model/Typereference ......................... : E02 ListedModels ...................................... : TD-E02 Modulation ........................................... : FM Hardwareversion.................................:V1.0 Softwareversion ................................. :V1.0 Frequency.............................................. FRS:462.5625MHz~462.7125MHz FRS:462.5500MHz~462.5750MHz FRS:467.5625MHz~467.7125MHz Rating ............................................... : DC5VPoweredbyadapter DC3.7VByLi-ionrechargeablebattery Result.....................................................: PASS ReportNo.:GRCTR260102045-01Page2of32 TESTREPORT EquipmentunderTest: TOWWAYRADIO Model/Type: E02 ListedModels: TD-E02 Applicant: ShenzhenTodakjCo.Ltd. Address: 2ndFloor,XinshidaiStationeryFactoryBuilding,Tiegang Community,XixiangSubdistrict,Bao'anDistrict,Shenzhen, GuangdongProvince,China Manufacturer: ShenzhenTodakjCo.Ltd. Address: 2ndFloor,XinshidaiStationeryFactoryBuilding,Tiegang Community,XixiangSubdistrict,Bao'anDistrict,Shenzhen, GuangdongProvince,China TestresultPass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR260102045-01Page3of32 Contents 1SUMMARY....................................................................................................................................................................4 1.1TESTSTANDARDS..........................................................................................................................................................4 1.2TESTDESCRIPTION............................................................................................................................................................4 2GENERALINFORMATION...............................................................................................................................................5 2.1GENERALREMARKS...........................................................................................................................................................5 2.2PRODUCTDESCRIPTION......................................................................................................................................................5 2.3DESCRIPTIONOFTESTMODESANDTESTFREQUENCY.............................................................................................................5 2.4EQUIPMENTUNDERTEST...................................................................................................................................................6 2.5SHORTDESCRIPTIONOFTHEEQUIPMENTUNDERTEST(EUT)...................................................................................................6 2.6BLOCKDIAGRAMOFTESTSETUP.........................................................................................................................................6 2.7RELATEDSUBMITTAL(S)/GRANT(S)....................................................................................................................................6 2.8MODIFICATIONS................................................................................................................................................................6 3TESTENVIRONMENT.....................................................................................................................................................7 3.1ADDRESSOFTHETESTLABORATORY......................................................................................................................................7 3.2TESTFACILITY...................................................................................................................................................................7 3.3ENVIRONMENTALCONDITIONS.............................................................................................................................................7 3.4STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................


Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2AQQS-E02 TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCCID:2AQQS-E02 TestSetupPhoto(s)ofRFMeasurement Fig.3

Test Setup Photos

IC:26512-E02 Page 1 of 1 FCC ID:2AQQS-E02 Front of face (Separation distance of 25mm) Body worn (Separation distance of 0mm)

Contact Information

Applicant

Li Huang(Manager)
[email protected]Fax: 0755-23725789

Technical Contact

Opuor INCShuiqing Yang
[email protected]

6510 S Academy Blvd Ste A 642 · United States

Test Firm

Shenzhen GUOREN Certification Technology Service CSam Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
195B462.5625 MHz - 462.7125 MHz1.8239 W10K1F3E2.5ppm
295B462.5625 MHz - 462.575 MHz1.845 W10K1F3E2.5ppm
395B467.5625 MHz - 467.7125 MHz444.00 mW10K1F3E2.5ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP. This device is authorized to operate in FRS (Part 95B) radio service. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessorytransmission exposure conditions are 0.65 W/kg and 0.85 W/kg, respectively when operating at 50% duty cycle.

Other Applications from Shenzhen Todakj Co., Ltd.

Toy walkie-talkie - FCC ID 2AQQS-W208 - Shenzhen Todakj Co., Ltd.
2AQQS-W208

Toy walkie-talkie

Jun 23, 2026

Equipment Class

FRF - Part 95 Family Radio Face Held Transmitter
2AQQS-T1920

Wireless Intercom Doorbell

Jan 19, 2026

Equipment Class

FRF - Part 95 Family Radio Face Held Transmitter
2AQQS-T1880

Wireless Intercom Doorbell

Jan 16, 2026

Equipment Class

FRF - Part 95 Family Radio Face Held Transmitter
Holding a walkie-talkie - FCC ID 2AQQS-G2PROPLUS - Shenzhen Todakj Co., Ltd.
2AQQS-G2PROPLUS

Holding a walkie-talkie

Sep 27, 2025

Equipment Class

FRF - Part 95 Family Radio Face Held Transmitter
Intercom Doorbell - FCC ID 2AQQS-S3 - Shenzhen Todakj Co., Ltd.
2AQQS-S3

Intercom Doorbell

Jul 16, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter