Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
120x80mm CE Maintenance 1. Use careful with the earphone maybe excessive sound pressure from earphones and headphones can cause hearing loss. 2. Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries ac- cording to the instructions. 3. The product shall only be connected to a USB interface of version USB2.0. 4.Adapter shall be installed near the equipment and shall be easily accessible. 5.EUT Operating temperature range: 0∞ C to 40∞ C . 6. Adapter: The plug considered as disconnect device of adapter Power supply and ADP(rating): Input: 100~240V, 50~60Hz, 0.25A Output: 5.0V, 1000mA Maximum utput power: 28.11dBm 7. The device complies with RF specifications when the device used at 25mm your body. 8. To prevent possible hearing damage. Do not listen at high volume levels for long periods. Declaration of Conformity Shenzhen Todakj Co.,Ltd. hereby declares that this Holding a walkie-talkie is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. In accordance with Article 10(2) and Article 10(10),This product is allowed to be used in all EU member states. Federal Communication Commission Interference Statement FCC ID: 2AQQS-G2PROPLUS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Radiation Exposure Statement: This device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard for wireless device employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg. Tests for SAR are conducted using standard operating positions (25mm) accepted by the FCC with the device transmitting at its highest certified power level in all tested frequency bands.
Attestation Statements 2025-09-17 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID:2AQQS-G2PROPLUS) Shenzhen Todakj Co.,Ltd., the undersigned, hereby authorize HOPEK CORPORATION INC to act as our designated U.S. agent for service of process, Shenzhen Todakj Co.,Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. HOPEK CORPORATION INC accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: Shenzhen Todakj Co.,Ltd. Contact Name: Li Huang Address: 2nd Floor, Xinshidai Stationery Factory Building, Tiegang Community, Xixiang Subdistrict, Bao’an District, Shenzhen, Guangdong Province, China FRN: 0027727668 Telephone No: 0755-26588927 Email: [email protected] Signature: Li Huang U.S. Agent Information: Company Name: HOPEK CORPORATION INC Address: 16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN: 0034562900 Contact Name: Peter Davis Telephone No: 561-235-6113 Email: [email protected] Signature: Peter Davis
Shenzhen Todakj Co.,Ltd. Date:9/17/2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2AQQS-G2PROPLUS) Shenzhen Todakj Co.,Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Li Huang Shenzhen Todakj Co.,Ltd. Date:9/17/2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2AQQS-G2PROPLUS) Shenzhen Todakj Co.,Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Li Huang
Shenzhen Todakj Co.,Ltd. 2025-09-17 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen LGT Test Service Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Date: 2025-09-17 Name: Li Huang Title: Manager Company: Shenzhen Todakj Co.,Ltd.
Shenzhen Todakj Co.,Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Shenzhen Todakj Co.,Ltd. Subject; Request for Confidentiality FCC ID: 2AQQS-G2PROPLUS To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Tune-up Procedure Part List PCB Layout SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Li Huang/Shenzhen Todakj Co.,Ltd. Title: Manager
Page 1 of 7 Report No.: LGT25H193 Appendix - External Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 7 Report No.: LGT25H193 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 7 Report No.: LGT25H193 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 7 Report No.: LGT25H193 Appendix - External Photographs of EUT Constructional Details Photo 7 Photo 8 Page 5 of 7 Report No.: LGT25H193 Appendix - External Photographs of EUT Constructional Details Photo 9 Photo 10 Page 6 of 7 Report No.: LGT25H193 Appendix - External Photographs of EUT Constructional Details Photo 11 Photo 12 Page 7 of 7 Report No.: LGT25H193 Appendix - External Photographs of EUT Constructional Details Photo 13 Photo 14
Holding a walkie-talkie Model: G2PROPLUS FCC ID: 2AQQS-G2PROPLUS
Page 1 of 4 Report No.: LGT25H193 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 4 Report No.: LGT25H193 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 4 Report No.: LGT25H193 Appendix - Internal Photographs of EUT Constructional Details Photo 5 Photo 6 ANT Page 4 of 4 Report No.: LGT25H193 Appendix - Internal Photographs of EUT Constructional Details Photo 7
Page: 1/11 Ref : ACR.163.3.25.BES.B Cancel and replace the report ACR.163.3.25.BES.A SHENZHEN LGT TEST SERVICE CO., LTD. ROOM 205, BUILDING 13, ZONE B, ZHENXIONG INDUSTRIAL PARK, NO.177, RENMIN WEST ROAD, JINSHA, KENGZI STREET, PINGSHAN DISTRICT, SHENZHEN, GUANGDONG, CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: 2225-EPGO-450 Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise – 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: 06/06/2025 Accreditations #2-6789 Scope available on www.cofrac.fr The use of the Cofrac brand and the accreditation references is prohibited from any reproduction. Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed at MVG, using the CALIPROBE test bench, for use with a MVG COMOSAR system only. The test results covered by accreditation are traceable to the International System of Units (SI). COMOSAR E-Field Probe Calibration Report Docusign Envelope ID: D3677F92-510E-48FC-B182-CD820765136E COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.163.3.25.BES.B Page: 2/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Pedro Ruiz Technical Manager 6/12/2025 Checked & approved by: Pedro Ruiz Technical Manager 6/12/2025 Authorized by: Kim Rutkowski Quality Manager Customer Name Distribution : SHENZHEN LGT TEST SERVICE CO., LTD. Issue Name Date Modifications A Pedro Ruiz 6/12/2025 Initial release B Pedro Ruiz 6/20/2025 Customer name & address Docusign Envelope ID: D3677F92-510E-48FC-B182-CD820765136E 6/23/2025 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.163.3.25.BES.B Page: 3/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Sensitivity _______________________________________________________________ 4 3.2 Linearity ________________________________________________________________ 5 3.3 Isotropy _________________________________________________________________ 5 3.4 Boundary Effect __________________________________________________________ 5 3.5 Probe Modulation Response _________________________________________________ 6 4 Measurement Uncertainty .......................................................................................... 6 5 Calibration Results ..................................................................................................... 6 5.1 Calibration in air __________________________________________________________ 6 5.2 Calibration in liquid _______________________________________________________ 7 6 Verification Results ................................................................................................... 8 7 List of Equipment .................................................................................................... 10 Docusign Envelope ID: D3677F92-510E-48FC-B182-CD820765136E COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.163.3.25.BES.B Page: 4/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number 2225-EPGO-450 Product Condition (new / used) New Frequency Range of Probe 0.15 GHz-7.5GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.226 M Dipole 2: R2=0.224 M Dipole 3: R3=0.229 M 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. Figure 1 – MVG COMOSAR Dosimetric E field Probe Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their effect. All calibrations / measurements performed meet the fore-mentioned standards. 3.1 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards for frequency range 600- 7500MHz and using the calorimeter cell method (transfer method) as outlined in the standards for frequency 150-450 MHz. Docusign Envelope ID: D3677F92-510E-48FC-B182-CD820765136E COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.163.3.25.BES.B Page: 5/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vM This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it …
Text truncated - open the document above for the full version.
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 31 SAR TEST REPORT Product Name: Holding a walkie-talkie Model Name: G2PROPLUS FCC ID: 2AQQS-G2PROPLUS Issued For : Shenzhen Todakj Co.,Ltd. 2nd Floor, Xinshidai Stationery Factory Building, Tiegang Community, Xixiang Subdistrict, Bao'an District, Shenzhen, Guangdong Province, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25H193HA02 Sample Received Date: Aug. 25, 2025 Date of Test Aug. 27, 2025 Date of Issue Sept. 09, 2025 Max. SAR (1g) Body: 1.546 W/kg Reprot No.: LGT25H193HA02 Page 2 of 31 Table of Contents 1. General Information 5 1.1 EUT Description 5 1.2 Test Environment 6 1.3 Test Factory 6 2. Test Standards and Limits 7 3. SAR Measurement System 8 3.1 Definition of Specific Absorption Rate (SAR) 8 3.2 SAR System 8 4. Tissue Simulating Liquids 11 4.1 Simulating Liquids Parameter Check 11 5. SAR System Validation 13 5.1 Validation System 13 5.2 Validation Result 13 6. SAR Evaluation Procedures 14 7. EUT Antenna Location Sketch 15 8. EUT Test Position 16 8.1 Body-worn Position Conditions 16 9. Uncertainty 17 9.1 Measurement Uncertainty 17 9.2 System validation Uncertainty 18 10. Conducted Power Measurement 19 10.1 Test Result 19 10.2 Tune up Power 19 11. EUT and Test Setup Photo 20 11.1 EUT Photos 20 11.2 Setup Photos 23 12. SAR Result Summary 25 12.1 Body-worn SAR 25 12.2 Repeated SAR 25 12.3 Repeated SAR measurement 25 13. Equipment List 26 Appendix A. System Validation Plots 27 Appendix B. SAR Test Plots 29 Appendix C. Probe Calibration and Dipole Calibration Report 31 Reprot No.: LGT25H193HA02 Page 3 of 31 Revision History Rev. Issue Date Contents 00 Sept. 09, 2025 Initial Issue Reprot No.: LGT25H193HA02 Page 4 of 31 TEST REPORT CERTIFICATION Applicant Shenzhen Todakj Co.,Ltd. Address 2nd Floor, Xinshidai Stationery Factory Building, Tiegang Community, Xixiang Subdistrict, Bao'an District, Shenzhen, Guangdong Province, China Manufacture Shenzhen Todakj Co.,Ltd. Address 2nd Floor, Xinshidai Stationery Factory Building, Tiegang Community, Xixiang Subdistrict, Bao'an District, Shenzhen, Guangdong Province, China Product Name Holding a walkie-talkie Trademark N/A Model Name G2PROPLUS Sample number LGT2508292 APPLICABLE STANDARDS STANDARD TEST RESULTS ANSI/IEEE Std. C95.1-2019 FCC 47 CFR Part 2 (2.1093) IEEE 1528: 2013 PASS Prepared by: Approved by: Deng Deng Engineer Vita Li Manager Reprot No.: LGT25H193HA02 Page 5 of 31 1. General Information Environmental evaluation measurements of specific absorption rate (SAR) distributions in emulated human head and body tissues exposed to radio frequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 1.1 EUT Description Product Name Holding a walkie-talkie Trademark N/A Test Model Name G2PROPLUS Series Model N/A Model Difference N/A Device Category Portable Product stage Production unit RF Exposure Environment General Population / Uncontrolled Hardware Version 01V01A Software Version 01V01 Frequency Range 462.5625-462.7125MHz 467.5625-467.7125MHz 462.5500-462.7250MHz Modulation Type: FM Max. Reported SAR(1g): Test distance: Face up:25mm Back Touch:0mm Mode Face up (with 25mm separation) Back Touch (with 0mm separation) Analog 1.168 1.546 Limit 1.6 W/kg Battery Capacity: 1800mAh Rated Voltage: 3.7V Operating Mode Maximum continuous output Antenna Specification Spring Antenna Reprot No.: LGT25H193HA02 Page 6 of 31 1.2 Test Environment Ambient conditions in the SAR laboratory: Items Required Temperature (°C) 18-25 Humidity (%RH) 30-70 1.3 Test Factory Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate FCC Registration No.: 746540 A2LA Certificate No.: 6727.01 IC Registration No.: CN0136 Reprot No.: LGT25H193HA02 Page 7 of 31 2. Test Standards and Limits No. Identity Document Title 1 47 CFR Part 2 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations 2 ANSI/IEEE Std. C95.1-2019 IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz 3 IEEE Std. 1528-2013 Recommended Practice for Determining the Peak Spatial- Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques 4 FCC KDB 447498 D01 v06 Mobile and Portable Device RF Exposure Procedures and Equipment Authorization Policies 5 FCC KDB 865664 D01 v01r04 SAR Measurement 100 MHz to 6 GHz 6 FCC KDB 865664 D02 v01r02 RF Exposure Reporting 7 FCC KDB 648474 D04 v01r03 SAR Evaluation Considerations for Wireless Handsets (A). Limits for Occupational/Controlled Exposure (W/kg) Whole-Body Partial-Body Hands, Wrists, Feet and Ankles 0.4 8.0 20.0 (B). Limits for General Population/Uncontrolled Exposure (W/kg) Whole-Body Partial-Body Hands, Wrists, Feet and Ankles 0.08 1.6 4.0 NOTE: Whole-Body SAR is averaged over the entire body, partial-body SAR is averaged over any 1 gram of tissue defined as a tissue volume in the shape of a cube. SAR for hands, wrists, feet and ankles is averaged over any 10 grams of tissue defined as a tissue volume in the shape of a cube. Population/Uncontrolled Environments: Are defined …
Text truncated - open the document above for the full version.
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Chen Hsong Industrial Park, No.177 Renmin West Road, Jinsha Community, Kengzi Street, Pingshan New District, Shenzhen, China RF TEST REPORT Product Name: Holding a walkie-talkie Model Name: G2PROPLUS FCC ID: 2AQQS-G2PROPLUS Issued For : Shenzhen Todakj Co.,Ltd. 2nd Floor, Xinshidai Stationery Factory Building, Tiegang Community, Xixiang Subdistrict, Bao'an District, Shenzhen, Guangdong Province, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Chen Hsong Industrial Park, No.177 Renmin West Road, Jinsha Community, Kengzi Street, Pingshan New District, Shenzhen, China Report Number: LGT25H193RF02 Sample Received Date: Aug. 22, 2025 Date of Test: Aug. 22, 2025 – Sep. 08, 2025 Date of Issue: Sep. 08, 2025 Report No.: LGT25H193RF02 Page 2 of 34 TEST REPORT CERTIFICATION Applicant: Shenzhen Todakj Co.,Ltd. Address: 2nd Floor, Xinshidai Stationery Factory Building, Tiegang Community, Xixiang Subdistrict, Bao'an District, Shenzhen, Guangdong Province, China Manufacturer: Shenzhen Todakj Co.,Ltd. Address: 2nd Floor, Xinshidai Stationery Factory Building, Tiegang Community, Xixiang Subdistrict, Bao'an District, Shenzhen, Guangdong Province, China Product Name: Holding a walkie-talkie Trademark: N/A Model Name: G2PROPLUS Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 95 TIA 603-E-2016 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT25H193RF02 Page 3 of 34 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.4 EQUIPMENTS LIST 12 3. FIELD STRENGTHS AND RADIATED SPURIOUS EMISSION 13 3.1 RADIATED EMISSION LIMITS 13 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULT 15 4. SPURIOUS EMISSION ON ANTENNA PORT 16 4.1 LIMIT 16 4.2 TEST PROCEDURE 16 4.3 TEST SETUP 16 4.4 EUT OPERATION CONDITIONS 16 4.5 TEST RESULT 16 5. BANDWIDTH TEST 17 5.1 LIMIT 17 5.2 TEST PROCEDURE 17 5.3 TEST SETUP 17 5.4 EUT OPERATION CONDITIONS 17 5.5 TEST RESULTS 18 6. EFFECTIVE RADIATED POWER (E.R.P) 20 6.1 LIMIT 20 6.2 TEST PROCEDURE 20 6.3 TEST SETUP 20 6.4 TEST RESULTS 21 7. EMISSION MASK 22 7.1 LIMIT 22 Report No.: LGT25H193RF02 Page 4 of 34 Table of Contents Page 7.2 TEST PROCEDURE 22 7.3 TEST SETUP 22 7.4 EUT OPERATION CONDITIONS 22 7.5 TEST RESULT 23 8. FREQUENCY STABILITY 25 8.1 LIMIT 25 8.2 TEST PROCEDURE 25 8.3 TEST SETUP 25 8.4 EUT OPERATION CONDITIONS 25 8.5 TEST RESULT 26 9. MODULATION LIMIT 28 9.1 LIMIT 28 9.2 TEST PROCEDURE 28 9.3 TEST SETUP 28 9.4 TEST RESULT 29 Report No.: LGT25H193RF02 Page 5 of 34 Revision History Rev. Issue Date Contents 00 Sep. 08, 2025 Initial Issue Report No.: LGT25H193RF02 Page 6 of 34 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part 95 Standard Section Test Item Judgment Remark FCC Part 95.567 Effective Radiated Power (e.r.p) PASS -- FCC Part 95.573 Authorized Bandwidth PASS -- FCC Part 95.579 Emission Mask PASS -- FCC Part 95.579 Transmitter Radiated Spurious Emission PASS -- FCC Part 95.579 Spurious Emission On Antenna Port PASS -- FCC Part 95.565 FCC Part 2.1055 Frequency Stability PASS -- FCC Part 95.575 FCC Part 2.1047 Modulation Limit PASS -- FCC Part 95.575 FCC Part 2.1047 Audio Frequency Response PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. Report No.: LGT25H193RF02 Page 7 of 34 1.1 TEST FACTORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Chen Hsong Industrial Park, No.177 Renmin West Road, Jinsha Community, Kengzi Street, Pingshan New District, Shenzhen, China Accreditation Certificate A2LA Certificate No.: 6727.01 FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.68dB 2 Unwanted Emissions, conducted ±2.988dB 3 All emissions, radiated 9K-30MHz ±2.84dB 4 All emissions, radiated 30M-1GHz ±4.39dB 5 All emissions, radiated 1G-6GHz ±5.10dB 6 All emissions, radiated>6G ±5.48dB 7 Conducted Emission (9KHz-150KHz) ±2.79dB 8 Conducted Emission (150KHz-30MHz) ±2.80dB Report No.: LGT25H193RF02 Page 8 of 34 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Holding a walkie-talkie Trademark: N/A Model Name: G2PROPLUS Series Model: N/A Model Difference: N/A Operation Frequency: 462.5625-462.7125MHz 467.5625-467.7125MHz 462.5500-462.7250MHz Modulation Type: FM Emission Type: 9K92F3E Antenna Type: Spring Antenna Antenna Gain (dBi): 2.82 Channel List: Please refer to the Note 3. Adapter: Input: 100~240V, 50~60Hz, 0.25A Output: 5.0V, 1000mA Charging Base: Input: DC5V Output: DC 5V 1A Battery: Capacity: 1800mAh Rated Voltage: 3.7V Hardware Version: 01V01A Software Version: 01V01 Connecting I/O Port(s): Please refer to the Note 1. Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User Manual. 2. The antenna information refers to the manufacturer provide report, applicable only to the tested sample identified in the report. Due to the incorrect antenna information, a series of problems such as the accuracy of the test results will be borne by the customer. Report No.: LGT25H193RF02 Page 9 of 34 3. Channel List Channel Frequency…
Text truncated - open the document above for the full version.
FCC ID_SAR Setup photos Body Face up (separation distance is 25mm) Body Back Touch (separation distance 0mm)
Page 1 of 1 Report No.: LGT25H193 Appendix - Test Setup photos Set-up for Radiated Spurious Emission, Below 1GHz Set-up for Radiated Spurious Emission, Above 1GHz
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95B | 462.5625 MHz - 462.7125 MHz | 1.84 W | 9K92F3E | 1.2969ppm |
| 2 | 95B | 467.5625 MHz - 467.7125 MHz | 450.00 mW | 9K92F3E | 1.283ppm |
| 3 | 95B | 462.55 MHz - 462.725 MHz | 1.92 W | 9K92F3E | 1.2969ppm |

TOW WAY RADIO
Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter
Toy walkie-talkie
Equipment Class
FRF - Part 95 Family Radio Face Held TransmitterWireless Intercom Doorbell
Equipment Class
FRF - Part 95 Family Radio Face Held TransmitterWireless Intercom Doorbell
Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter
Intercom Doorbell
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter