2AQRM-IQ50Redcap Module

FOXX Development Inc.

Application Details

Equipment Class
CBE - Citizens Band End User Devices
Date of Grant
Jan 30, 2026
Application Purpose
Original Equipment
Equipment Note
Redcap Module
Frequency Range
3560.00000000 - 3590.00000000
Company
FOXX Development Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 FOXX Development Inc. 3480 Preston Ridge Road, Suite500, Alpharetta, Georgia, 30005, United States Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: January 23, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AQRM-IQ50 FOXX Development Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. FOXX Development Inc. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, Contact Person: James Liao FOXX Development Inc. Tel: 858-925-4348 Fax: 8555153699 E-mail: [email protected] Rev 1/26/2023 FOXX Development Inc. 3480 Preston Ridge Road, Suite500, Alpharetta, Georgia, 30005, United States Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: January 23, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AQRM-IQ50 FOXX Development Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Contact Person: James Liao FOXX Development Inc. Tel: 858-925-4348 Fax: 8555153699 E-mail: [email protected]

Attestation Statements

Rev 1/26/2023 FOXX Development Inc. 3480 Preston Ridge Road, Suite500, Alpharetta, Georgia, 30005, United States Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: January 23, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AQRM-IQ50 Applicant FRN: 0027735299 FOXX Development Inc. (“the applicant”) certifies that, as of the date of the filing of the application, FOXX Development Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. FOXX Development Inc. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. FOXX Development Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: FOXX Development Inc. U.S. Agent FRN: 0027735299 Address: 3480 Preston Ridge Rd, STE 500, Alpharetta, GA 30005, United States Contact Person: James Liao Tel.: (855) 585-3699 Email: [email protected] Sincerely, FOXX Development Inc. FOXX Development Inc. James Liao James Liao ·

Attestation Statements

FOXX Development Inc. 3480 Preston Ridge Road, Suite500, Alpharetta, Georgia, 30005, United States Date: January 23, 2026 Modular Approval Request FCC (KDB 996369 D01 & Part 15.212) FCC ID: 2AQRM-IQ50 Items to be covered by Single modular transmitters. Answer from applicant 1. The modular transmitter must have its own RF shielding. The radio portion of this module is shielded. 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with Part 15 requirements under conditions of excessive data rates or over-modulation. The module has buffer modulation/data inputs. 3. The modular transmitter must have its own power supply regulation. The module has its own power supply regulation. 4. The modular transmitter must comply with the antenna requirements of Section 15.203 and 15.204(b)(c). The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). The requirements of antenna connector and spurious emission have been fulfilled. 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing. This is intended to demonstrate that the module is capable of complying with Part 15 emission limits regardless of the device into which it is eventually installed. The required rule has been fulfilled. 6. The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number in accordance with 15.212 (a)(1)(vi)(A) / (B). The Module will be labeled with its own FCC ID, and the instruction on the labeling rule of the end product has been stated in the User Manual of this module. 7. The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. For example, there are very strict operational and timing requirements that must be met before a transmitter is authorized for operation under Section 15.231. For instance, data transmission is prohibited, except for operation under Section 15.231(e), in which case there are separate field strength level and timing requirements. Compliance with these requirements must be assured. The required rule has been fulfilled and all the instructions for maintaining compliance have been clearly stated in the User Manual. 8. The modular transmitter must comply with any applicable RF exposure requirements. For example, FCC Rules in Sections 1.1310, 2.1091, 2.1093, and specific Sections of Part 15, including 15.319(i), 15.407(f), 15.253(f) and 15.255(g), require that Unlicensed PCS, UNII and millimeter wave devices perform routine environmental evaluation for RF Exposure to demonstrate compliance. In addition, spread spectrum transmitters operating under Section 15.247 are required to address RF Exposure compliance. Modular transmitters approved under other Sections of Part 15, when necessary, may also need to address certain RF Exposure concerns, typically by providing specific installation and operating instructions for users, installers and other interested parties to ensure compliance. The required rule has been fulfilled and all the instructions for maintaining compliance have been clearly stated in the User Manual. If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you! Contact Person: James Liao FOXX Development Inc. Tel: 858-925-4348 Fax: 8555153699 E-mail: [email protected]

Cover Letter(s)

FOXX Development Inc. 3480 Preston Ridge Road, Suite500, Alpharetta, Georgia, 30005, United States Date: January 23, 2026 Federal Communications Commission 7435 Oakland Mills Road - Gate A Columbia, Maryland 21046 Subject: Request for Confidentiality FCC ID: 2AQRM-IQ50 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely.  Schematic Diagram  Block Diagram  Operational Description  Part List  Tune up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days after the Grant Date of Equipment Authorizations.  External Photos  Internal Photos  Test Setup Photos  Users Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, Contact Person: James Liao FOXX Development Inc. Tel: 858-925-4348 Fax: 8555153699 E-mail: [email protected]

Cover Letter(s)

FOXX Development Inc. 3480 Preston Ridge Road, Suite500, Alpharetta, Georgia, 30005, United States Date: January 23, 2026 Power of Attorney To whom it may concern, Please be notified that I, FOXX Development Inc., have designated Yuchen Zhao of Huarui 7layers High Technology (Suzhou) Co., Ltd. as the person being responsible for this project and to sign the form 731 and other documentation. Any and all acts carried out by Yuchen Zhao of Huarui 7layers High Technology (Suzhou) Co., Ltd. on the matters relating to all processes required in the FCC approval and any communication needed with the national authority, shall have the same legal authority as acts on our own behalf. As defined in 47 CFR Ch. 1.U.S .C . 862, we further certify that neither the applicant nor any party to this application is subject to a denial to Federal benefits, including FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act. This authorization is limited to the product of as following: FCC ID: 2AQRM-IQ50 If you have any acknowledgement and response, please send it to Yuchen Zhao of Huarui 7layers High Technology (Suzhou) Co., Ltd. directly. Should you have any question or comment regarding this matter, please have my best attention. Sincerely yours, _______________ Contact Person: James Liao FOXX Development Inc. Tel: 858-925-4348 Fax: 8555153699 E-mail: [email protected]

ID Label/Location Info

A B C D E F A B C D E F 12345678 12345678 IMEI: XXXXXXXXXXXXXXX SN: XXXXXXXXXXXXXXXXXXX IQ50 The QR code information includes SN and IMEI. After scanning with a barcode gun, both pieces of information will be displayed simultaneously. The format of the QR code information is as follows: a. The SN laser-engraved QR code uses the QR Code format, with an appearance size of 10*10mm. b. The content of the QR code is SN + space + IMEI. MiSans Bold 6.5pt MiSans 5pt SN+ blank+IMEI 5.29mm*4.19mm Line spacing:2mm FOXX DEVELOPMENT INC FCC ID2AQRM-IQ50

RF Exposure Info

FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Dec. 31, 2025 Report No. : PSU-QBJ2512030110SA01 Page 1 of 8 FCC RF Exposure Test Report Report No. : PSU-QBJ2512030110SA01 Applicant : FOXX Development Inc Address : 3480 Preston Ridge Road Suite 500, Alpharetta, GA 30005 Product : REDCAP MODULE FCC ID : 2AQRM-IQ50 Brand : FOXX Model No. : IQ50 Standards : FCC Part 2 (Section 2.1091) KDB 447498 D01 General RF Exposure Guidance v06 Sample Received Date : Dec. 05, 2025 Date of Testing : Dec. 05, 2025 ~Dec. 31, 2025 Test Lab : The FCC Site Registration No. is 434559; The Designation No. is CN1325. Issued By : Huarui 7layers High Technology (Suzhou) Co., Ltd. Address : Tower N, Innovation Center, 88 Zuyi Road, High-tech District, Suzhou City, Anhui Province, China CERTIFICATION: The above equipment have been tested by Huarui 7Layers High Technology (Suzhou) Co., Ltd., and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s SAR characteristics under the conditions specified in this report. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by A2LA or any government agencies. Prepared By : Approved By : (Chang Gao / Engineer) (Luke Lu /Manager) This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Dec. 31, 2025 Report No. : PSU-QBJ2512030110SA01 Page 2 of 8 TABLE OF CONTENTS RELEASE CONTROL RECORD .................................................................................................................................................... 3 1. DESCRIPTION OF EQUIPMENT UNDER TEST .................................................................................................................... 4 2. MPE(MAXIMUM PERMISSIBLE EXPOSURE) ASSESSMENT ............................................................................................. 5 2.1 INTRODUCTION .......................................................................................................................................................... 5 2.2 RF RADIATION EXPOSURE LIMITS ........................................................................................................................... 5 2.3 MPE ASSESSMENT METHOD .................................................................................................................................... 6 2.4 MPE CALCULATION FOR STANDALONE OPERATIONS .......................................................................................... 6 3. INFORMATION ON THE TESTING LABORATORIES ........................................................................................................... 8 FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Dec. 31, 2025 Report No. : PSU-QBJ2512030110SA01 Page 3 of 8 Release Control Record Report No. Reason for Change Date Issued PSU-QBJ2512030110SA01 Original release Dec. 31, 2025 FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Dec. 31, 2025 Report No. : PSU-QBJ2512030110SA01 Page 4 of 8 1. Description of Equipment Under Test EUT Type* Redcap Module Brand Name* FOXX Model Name* IQ50 Tx Frequency Bands (Unit: MHz) 1850.7MHz ~ 1909.3MHz (FOR LTE Band2) 1710.7MHz ~ 1754.3MHz (FOR LTE Band4) 824.7MHz ~ 848.3MHz (FOR LTE Band5) 2502.5MHz ~ 2567.5MHz (FOR LTE Band7) 699.7MHz ~ 715.3MHz (FOR LTE Band12) 779.5MHz ~ 784.5MHz (FOR LTE Band13) 790.5MHz ~ 795.5MHz (FOR LTE Band14) 706.5MHz ~ 713.5MHz (FOR LTE Band17) 1850.7MHz ~ 1914.3MHz (FOR LTE Band25) 814.7MHz ~ 848.3MHz (FOR LTE Band26) 2307.5 MHz ~ 2312.5 MHz (FOR LTE Band30) 2572.5MHz ~ 2617.5MHz (FOR LTE Band38) 2498.5MHz ~2687.5MHz (FOR LTE Band41) 3452.5MHz ~3597.5MHz (FOR LTE Band42) 3602.5MHz ~3697.5MHz (FOR LTE Band43) 3552.5MHz ~3697.5MHz (FOR LTE Band48) 1710.7MHz ~ 1779.3MHz (FOR LTE Band66) 665.5MHz ~ 695.5MHz (FOR LTE Band71) SA/NSA: n2 (1852.5MHz ~1907.5MHz) n5(826.5MHz ~ 846.5MHz) n7(2502.5MHz ~ 2567.5MHz) n12(701.5MHz ~ 713.5MHz) n13(779.5MHz ~ 784.5MHz) n14(790.5MHz ~ 795.5MHz) n25(1852.5MHz ~ 1912.5MHz) n26(816.6MHz ~ 846.5MHz) n30(2307.5MHz ~ 2312.5MHz) n38(2575MHz ~ 2615MHz) n41(2501.01MHz ~ 2685MHz) n48(3555MHz ~ 3694.98MHz) n66…

Text truncated - open the document above for the full version.

Test Report

PERFECT STATUS, ALLWAYS SEEKS FOR THE BETTER. www.auden.com.tw Electrical Specifications Frequency 600MHz‐6GHz Polarization Linear Vertical Nominal Impedance 50Ω VSWR <3 Max input power 2W Mechanical Planner Dimention 221*26.95mm Casing PC+ABS Connector SMA(M/F) Appearance Color Black Weight 28.3g Environmental Temperature Range ‐40°C to 85°C Humidity Non‐condensing 65°C 95% RH 5G Multiband Antenna with 90° Hinged SMA connector Auden Part Number: AUK02005‐5G This 5G Antenna is designed for use with 5G modules and devices that require high efficiency and peak gain to deliver best in class throughput on all major cellular (5G/4G/3G/2G) bands worldwide for access points, terminals and routers. The antenna has an SMA connector and swivel mechanism that allows the antenna to be rotated. It exhibits 50~80% efficiency across the wideband Sub 6G and is backwards compatible with 5G/4G/3G/2G cellular applications such as 5G, LTE, GSM, UMTS, Wi‐Fi. With high efficiency on every cellular band globally it is an ideal solution for any device requiring high, reliable performance but in a slim form factor. It is also guaranteed to meet any type of approval or carrier certification requirements from an RF standpoint. Applications: 5G CPE / Camera 5G Devices PERFECT STATUS, ALLWAYS SEEKS FOR THE BETTER. www.auden.com.tw Antenna Charateristics VSWR Return Loss 2D & 3D Radiation Patterns 600MHz PERFECT STATUS, ALLWAYS SEEKS FOR THE BETTER. www.auden.com.tw 705MHZ 825MHz PERFECT STATUS, ALLWAYS SEEKS FOR THE BETTER. www.auden.com.tw 960MHz 1710MHz PERFECT STATUS, ALLWAYS SEEKS FOR THE BETTER. www.auden.com.tw 2690MHz 3400MHz PERFECT STATUS, ALLWAYS SEEKS FOR THE BETTER. www.auden.com.tw 4800MHz 5800MHz PERFECT STATUS, ALLWAYS SEEKS FOR THE BETTER. www.auden.com.tw Product Drawing Auden is the world’s leading antenna provider of wireless technology communication, established in 1981, more than 300 staffs in worldwide, and headquartered in Taoyuan Taiwan. We have R&D centers in Taiwan, Kunshan, Shenzhen and Xi’an to provide customers with faster and more direct services. Over the years, we have been devoting to antenna technology development in mobile communication, Networking, Internet of Things, Internet of Vehicles, smart homes, industrial applications, etc. And now, we already have developed Sub‐6G antenna solutions and mmWave antenna module for various 5G applications. Auden believes “Perfect status, always seek for better”, keep providing novel antenna technology, high‐quality products and fast service to become your best partner.

Test Report

Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 1 of 124 FCC TEST REPORT (PART 96) Applicant: FOXX Development Inc Address: 3480 Preston Ridge Road Suite 500, Alpharetta, GA 30005 Manufacturer or Supplier: FOXX Development Inc Address: 3480 Preston Ridge Road Suite 500, Alpharetta, GA 30005 Product: Redcap Module Brand Name: FOXX Model Name: IQ50 FCC ID: 2AQRM-IQ50 Date of tests: Dec. 05, 2025 ~Dec. 31, 2025 The tests have been carried out according to the requirements of the following standard: 47 CFR FCC Part 96 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Carl Xie Engineer / Mobile Department Approved by Luke Lu Manager / Mobile Department Date:Jan. 12, 2026 Date: Jan. 12, 2026 BOOMWAVE TEST (SHENZHEN) CO., LTD. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. The results documented in this report apply only the tested sample, under the conditions and modes of operation as described herein. It is the manufacturer's responsibility assure that additional production units of the model are manufactured with identical electrical and mechanical components. All sample tested were in good operating condition throughout the entire test program. Measurement Uncertainties are published for informational purposes only and were not taken into account unless noted otherwise. without written approval of BOOMWAVE TEST (SHENZHEN) CO., LTD., the test report shall not be reproduced except in full. Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 2 of 124 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS ................................................................................................. 5 1.1 MEASUREMENT UNCERTAINTY ............................................................................................ 6 1.2 TEST SITE AND INSTRUMENTS ............................................................................................ 7 2 GENERAL INFORMATION .......................................................................................................... 9 2.1 GENERAL DESCRIPTION OF EUT ......................................................................................... 9 2.2 CONFIGURATION OF SYSTEM UNDER TEST .................................................................... 12 2.3 DESCRIPTION OF SUPPORT UNITS ................................................................................... 13 2.4 TEST ITEM AND TEST CONFIGURATION ............................................................................ 13 2.5 GENERAL DESCRIPTION OF APPLIED STANDARDS ........................................................ 18 3 TEST TYPES AND RESULTS ................................................................................................... 19 3.1 MAXIMUM EIRP MEASUREMENT ........................................................................................ 19 3.1.1 LIMITS OF MAXIMUM EIRP MEASUREMENT ...................................................................... 19 3.1.2 TEST SETUP .......................................................................................................................... 19 3.1.3 TEST PROCEDURES ............................................................................................................. 20 3.1.4 DEVIATION FROM TEST STANDARD ................................................................................... 20 3.1.5 TEST RESULTS ...................................................................................................................... 21 3.2 CONDUCTED BAND EDGE ........................................................................................................ 44 3.2.1 LIMITS OF CONDUCTED BAND EDGE MEASUREMENT ..................................................... 44 3.2.2 TEST SETUP ............................................................................................................................ 44 3.2.3 TEST INSTRUMENTS .............................................................................................................. 44 3.2.4 TEST PROCEDURE ................................................................................................................. 45 3.2.5 DEVIATION FROM TEST STANDARD .................................................................................... 45 3.2.6 TEST RESULTS ........................................................................................................................ 46 3.3 FREQUENCY STABILITY MEASUREMENT............................................................................... 47 3.3.1 LIMITS OF FREQUENCY STABILITY MEASUREMENT ......................................................... 47 3.3.2 TEST PROCEDURE ................................................................................................................. 47 3.3.3 TEST SETUP ............................................................................................................................ 47 3.3.4 TEST RESULTS ........................................................................................................................ 48 3.4 OCCUPIED BANDWIDTH MEASUREMENT .............................................................................. 49 3.4.1 OCCUPIED BANDWIDTH MEASUREMENT .…

Text truncated - open the document above for the full version.

Test Report

Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 86 of 124 Band48-15MHz-16QAM-55990-1RB#0-PASS Band48-15MHz-16QAM-55990-75RB#0-PASS Band48-15MHz-16QAM-56665-1RB#0-PASS Band48-15MHz-16QAM-56665-75RB#0-PASS Band48-20MHz-QPSK-55340-1RB#0-PASS Band48-20MHz-QPSK-55340-100RB#0-PASS Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 87 of 124 Band48-20MHz-QPSK-55990-1RB#0-PASS Band48-20MHz-QPSK-55990-100RB#0-PASS Band48-20MHz-QPSK-56640-1RB#0-PASS Band48-20MHz-QPSK-56640-100RB#0-PASS Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 88 of 124 Band48-20MHz-64QAM-55340-1RB#0-PASS Band48-20MHz-64QAM-55340-100RB#0-PASS Band48-20MHz-64QAM-55990-1RB#0-PASS Band48-20MHz-64QAM-55990-100RB#0-PASS Band48-20MHz-64QAM-56640-1RB#0-PASS Band48-20MHz-64QAM-56640-100RB#0-PASS Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 89 of 124 Band48-20MHz-16QAM-55340-1RB#0-PASS Band48-20MHz-16QAM-55340-100RB#0-PASS Band48-20MHz-16QAM-55990-1RB#0-PASS Band48-20MHz-16QAM-55990-100RB#0-PASS Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 90 of 124 Band48-20MHz-16QAM-56640-1RB#0-PASS Band48-20MHz-16QAM-56640-100RB#0-PASS Test Report No.: PSU-QBJ2512030110RF06 Boomwave Test (Shenzhen) co., Ltd. Rm B38, Warehouse A5(Chiwan #1), #3 Chiwan 4th Rd, Chiwan Comm, Zhaoshang St, Nanshan Dist, Shenzhen, Guangdong, Shenzhen, China Mobile: +86 15118052731 Email:[email protected] Page 91 of 124 26dB Bandwidth and Occupied Bandwidth Test Result Band Bandwidth Modulation Channel RB Configuration Occupied Bandwidth (MHz) 26dB Bandwidth (MHz) Verdict Band48 5MHz QPSK 55265 25RB#0 4.5253 5.235 PASS Band48 5MHz QPSK 55990 25RB#0 4.5257 5.376 PASS Band48 5MHz QPSK 56715 25RB#0 4.5124 5.227 PASS Band48 5MHz 64QAM 55265 25RB#0 4.5183 5.621 PASS Band48 5MHz 64QAM 55990 25RB#0 4.5337 5.233 PASS Band48 5MHz 64QAM 56715 25RB#0 4.5163 5.327 PASS Band48 5MHz 16QAM 55265 25RB#0 4.5209 5.156 PASS Band48 5MHz 16QAM 55990 25RB#0 4.5151 5.652 PASS Band48 5MHz 16QAM 56715 25RB#0 4.5166 5.343 PASS Band48 10MHz QPSK 55290 50RB#0 9.0258 11.29 PASS Band48 10MHz QPSK 55990 50RB#0 9.0278 10.59 PASS Band48 10MHz QPSK 56690 50RB#0 9.0415 10.86 PASS Band48 10MHz 64QAM 55290 50RB#0 9.0206 10.97 PASS Band48 10MHz 64QAM 55990 50RB#0 9.0148 10.74 PASS Band48 10MHz 64QAM 56690 50RB#0 9.0224 10.90 PASS Band48 10MHz 16QAM 55290 50RB#0 9.0224 11.09 PASS Band48 10MHz 16QAM 55990 50RB#0 9.0173 9.981 PASS Band48 10MHz 16QAM 56690 50RB#0 9.0262 10.39 PASS Band48 15MHz QPSK 55315 75RB#0 13.583 16.11 PASS Band48 15MHz QPSK 55990 75RB#0 13.531 15.62 PASS Band48 15MHz QPSK 56665 75RB#0 13.507 15.27 PASS Band48 15MHz 64QAM 55315 75RB#0 13.599 15.86 PASS Band48 15MHz 64QAM 55990 75RB#0 13.508 15.46 PASS Band48 15MHz 64QAM 56665 75RB#0 13.510 15.36 PASS Band48 15MHz 16QAM 55315 75RB#0 13.532 16.24 PASS Band48 15MHz 16QAM 55990 75RB#0 13.582 15.89 PASS Band48 15MHz 16QAM 56665 75RB#0 13.477 14.97 PASS Band48 20MHz QPSK 55340 100RB#0 17.984 20.96 PASS Band48 20MHz QPSK 55990 100RB#0 17.998 20.60 PASS Band48 20MHz QPSK 56640 100RB#0 17.998 20.85 PASS Band48 20MHz 64QAM 55340 100RB#0 18.081 21.63 PASS Band48 20MHz 64QAM 55990 100RB#0 17.946 19.57 PASS Band48 20MHz 64QAM 56640 100RB#0 18.028 22.01 PASS Band48 20MHz 16QAM 55340 100RB#0 18.031 20.06 PASS Band48 20MHz 16QAM 55990 100RB#0 18.034 20.70 PASS Band48 20MHz 16QAM 56640 100RB#0 17.981 20.04 …

Text truncated - open the document above for the full version.

Contact Information

Applicant

James Liao(CTO)
[email protected]Fax: 8555153699

Technical Contact

FOXX Development Inc.James Liao
[email protected]

3480 Preston Ridge Rd, STE 500 · Alpharetta, Georgia, 30005 · United States

Test Firm

Boomwave Test (Shenzhen) Co., Ltd.Peibo Sun
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1963.56 GHz - 3.59 GHz185.00 mW18M0G7D0.07ppm
2963.56 GHz - 3.59 GHz148.00 mW18M1W7D0.07ppm
3963.61 GHz - 3.69 GHz190.00 mW18M0G7D0.07ppm
4963.61 GHz - 3.69 GHz156.00 mW18M1W7D0.07ppm
5963.56 GHz - 3.69 GHz197.00 mW18M0G7D0.07ppm
6963.56 GHz - 3.69 GHz163.00 mW18M1W7D0.07ppm
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Output power listed is EIRP. Single Modular Approval for mobile RF Exposure conditions. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm from all persons and any additional testing and authorization process as required. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports LTE of 5, 10, 15, and 20 MHz bandwidth modes for TDD LTE Bands 42, 43 and 48.

Other Applications from FOXX Development Inc.

Feature Phone - FCC ID 2AQRM-F117 - FOXX Development Inc.
2AQRM-F117

Feature Phone

Sep 10, 2026

Equipment Class

DTS - Digital Transmission System
2AQRM-VI02

4G Smart Dash Camera Full HD

Jan 09, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
2AQRM-Q3

5G Mobile Hotspot

Jan 06, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2AQRM-W3

Kids Smartwatch

Dec 08, 2025

Equipment Class

PCT - PCS Licensed Transmitter worn on body
2AQRM-C69M

Smart Phone

Nov 21, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX