Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Contents Safety Notice ............................................................... 02 Unit Illustration ......................................................... 06 Important Testing Guidelines ..................................... 08 Quick Start ................................................................. 09 Unit Operation ........................................................... 10 Blood Pressure Information ........................................ 23 Blood Pressure Q&A ................................................... 26 Maintenance ............................................................... 27 Specifications ............................................................. 29 Warranty .................................................................... 31 Electromagnetic Compatibility Information .............. 32 Battery Installation .................................................. 10 System Settings ........................................................ 11 Applying the Arm Cuff ............................................. 13 Testing ..................................................................... 14 Power Off ................................................................ 17 Memory Check ........................... 18 Memory Deletion ..................................................... 19 Low Battery Indicator ............................................. 19 Bluetooth requirement and connection .............. 20 Troubleshooting ................................................... 22 and Last 3 Test Average Safety Notice Model DBP-6275B Arm Type 12 Owner's Manual Arm-type Fully Automatic Digital Blood Pressure Monitor Thank you for purchasing the DBP-6275B Blood Pressure Monitor. The unit has been constructed using reliable circuitry and durable materials. Used properly, this unit will provide years of satisfactory use. Measure blood pressure(systolic and diastolic)and pulse rate of adults and adolecents age 12 through 21years of age. All functions can be used safely and values can be read out in one LCD DISPLAY. Measurement position is on adult upper arm only. Blood pressure measurement determined with this device are equivalent to those obtained by a trained observer using the cuff/ stethoscope auscultation method, within the limits prescribed by the Recognized Consensus Standard (IEC 81060-2-30) for electronic sphygmomanometers. Precautions to Ensure Safe, Reliable Operation 1. Do not drop the unit. Protect it from sudden jars or shocks. 2. Do not insert foreign objects into any openings. 3. Do not attempt to disassemble the unit. 4. Do not crush the pressure cuff. 5. If the unit has been stored at temperatures below 0 oC, leave it in a warm place for about 15 minutes before using it. Otherwise, the cuff may not inflate properly. 6. If the unit has been stored at temperatures above 40 oC, leave it in a cool place for about 15 minutes before using it. Otherwise, the cuff may not inflate properly. 7. Do not store the unit in direct sunlight, high humidity or dust. 8.To avoid any possibility of accidental strangulation, keep this unit away from children and do not drape tubing around your neck. 9.Ensure that children do not use the instrument unsupervised; some parts are small enough to be swallowed. 10.Some may get a skin irritation from the cuff taking frequent readings over the course of the day, but this irritation typically goes away on its own after the monitor is removed. The PATIENT is an intended OPERATOR Document No.:JDBP-7504-054 Contact Information The lay operator or lay responsible or ganization should contact the manufacturer or the representative of manufacturer. -for assistance,if needed,in setting up,using or maintaining the product,or -to report unexpected operation or events. Manufactured by JOYTECH Healthcare Co.,Ltd. Email: [email protected] Telephone: +86-571-81957767 Fax: +86-571-81957750 No.365, Wuzhou Road,Yuhang Economic Development Zone, Hangzhou City,311100 Zhejiang,China Version:Z Date of Issue:2020.06 Unit Illustration 6 Arm Cuff Medium size cuff (fits arm circumference: 22.0 cm -36.0 cm). If air is leaking from the arm cuff, replace the arm cuff with a new one. It is generally recomm ended to have the cuff replaced timely to ensure correct functioning and accuracy. Please consult your local authorized Sejoy distributor or dealer. 5 Safety NoticeSafety Notice 34 Important Instructions Before Use 1. Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history. 2. Contact your physician if test results regularly indicate abnormal readings. 3. If you are taking medication, consult with your physician to determine the most appropriate time to measure your blood pressure. NEVER change a prescribed medication without first consulting with your physician. 4. Individuals with serious circulation problems may experience discomfort. Consult your physician prior to use. 5. For persons with irregular or unstable circulation resulting from diabetes, liver disease, arteriosclerosis or other medical conditions, there may be variations in blood pressure values measured at the wrist versus at the upper arm. Monitoring the trends in your blood pressure taken at either the arm or the wrist is nevertheless useful and important. 6. People suffering from vascular constriction, liver disorders or diabetes, people with cardiac pacemakers or a weak pulse, and women who are pregnant should consult their physician before measuring their blood pressure themselves. Different values may be obtained due to their condition. 7. People suffering from arrhythmias such as atrial or ventricular premature beats or atrial fibrillation only use this blood pressure monitor in consultation with your doctor. In certain cases oscillometric measurement method can produce incorrect readings. 15. Product is designed for its intended use only. Do not misuse in any way…
Text truncated - open the document above for the full version.
ReportNo.:EED32N00003501Page 38 of 47 PHOTOGRAPHSOFEUTConstructionalDetails TestmodelNo.:DBP-6275B ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32N00003501Page 39 of 47 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32N00003501Page 40 of 47 ViewofProduct-5 ViewofProduct-6 ReportNo.:EED32N00003501Page 41 of 47 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32N00003501Page 42 of 47 ViewofProduct-9 ViewofProduct-10
Label: Labellocation:
Report No. : EED32N00003501Page 41 of 46 View of Product-9 View of Product-10 Report No. : EED32N00003501Page 42 of 46 View of Product-11 View of Product-12 Report No. : EED32N00003501Page 43 of 46 View of Product-13 View of Product-14 Report No. : EED32N00003501Page 44 of 46 View of Product-15 View of Product-16 Report No. : EED32N00003501Page 45 of 46 View of Product-17 View of Product-18 Report No. : EED32N00003501Page 46 of 46 View of Product-19 View of Product-20 The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CTI, this report can’t be reproduced except in full. *** End of Report ***
ReportNo.:EED32N00003502Page1of8 1COVERPAGE RFExposureEvaluationReport Preparedfor: JOYTECHHealthcareCo.,Ltd. No.365,WuzhouRoad,Yuhang EconomicDevelopmentZone,Hangzhou City,311100ZhejiangP.R.China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: TomChenAaronMa Approvedby:Date:Mar.26,2021 DavidWang CheckNo.: 4538073830 Product:Arm-TypeFullyAutomaticDigital BloodPressureMonitor Trademark: N/A Model/Typereference: DBP-6275B SerialNumber: N/A ReportNumber: EED32N00003502 FCCID:2AQVU0016 DateofIssue:Mar.26,2021 TestStandards:47CFRPart1.1307 47CFRPart2.1093 KDB447498D01GeneralRF ExposureGuidancev06 Testresult:PASS ReportNo.:EED32N00003502Page2of8 2Version VersionNo.DateDescription 00 Mar.26,2021 Original ReportNo.:EED32N00003502Page3of8 3Contents Page 1COVERPAGE......................................................................................................................................................................1 2VERSION..............................................................................................................................................................................2 3CONTENTS..........................................................................................................................................................................3 4GENERALINFORMATION...............................................................................................................................................4 4.1C LIENT I NFORMATION ....................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ........................................................................................4 4.4T EST L OCATION .............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS ......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ..............................................................................................5 5SAREVALUATION.............................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT ...............................................................................................................6 5.1.1StandardRequirement........................................................................................................................................6 5.1.2EUTRFExposure...............................................................................................................................................7 PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS............................................................................................8 ReportNo.:EED32N00003502Page4of8 4GeneralInformation 4.1ClientInformation Applicant: JOYTECHHealthcareCo.,Ltd. AddressofApplicant: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100ZhejiangP.R.China Manufacturer: JOYTECHHealthcareCo.,Ltd. AddressofManufacturer: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100ZhejiangP.R.China Factory: JOYTECHHealthcareCo.,Ltd. AddressofFactory: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100ZhejiangP.R.China 4.2GeneralDescriptionofEUT ProductName: Arm-TypeFullyAutomaticDigitalBloodPressureMonitor ModeNo.(EUT): DBP-6275B TradeMark: N/A EUTSupportsRadios application: BT5.0Singlemodule2402MHzto2480MHz 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange: BT5.0Singlemodule2402MHzto2480MHz; ModulationType:GFSK TestPowerGrade: Default TestSoftwareofEUT: PhyPlusKit.exe AntennaType: PCBantenna AntennaGain: 0.5dBi PowerSupply: 3X1.5VBatteries;sizeAAA MaxConductedPeak OutputPower: -0.49dBm TheMaxConductedPeakOutputPowerdatarefertothereport EED32N00003501 SampleReceivedDate: Jan.19,2021 SampletestedDate: Jan.19,2021toMar.23,2021 CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32N00003502Page5of8 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32N00003502Page6of8 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbody and10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurementor numericalsimulation,isnotrequiredwhenthecorrespondingSARExclusionThresholdcondition,listed below,issatisfied. Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparationdistances ≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)]· [√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz Poweranddistanceare…
Text truncated - open the document above for the full version.
Report No. EED32N00003501 Page 1 of 25 Appendix: Bluetooth LE Report No. EED32N00003501 Page 2 of 25 Contents Appendix A: DTS Bandwidth ..................................................................................................... 3 Test Result ............................................................................................................................................. 3 Test Graphs ........................................................................................................................................... 4 Appendix B: Occupied Channel Bandwidth............................................................................... 6 Test Result ............................................................................................................................................. 6 Test Graphs ........................................................................................................................................... 7 Appendix C: Maximum conducted output power ..................................................................... 9 Test Result ............................................................................................................................................. 9 Test Graphs ......................................................................................................................................... 10 Appendix D: Maximum power spectral density ...................................................................... 12 Test Result ........................................................................................................................................... 12 Test Graphs ......................................................................................................................................... 13 Appendix E: Band edge measurements .................................................................................. 15 Test Result ........................................................................................................................................... 15 Test Graphs ......................................................................................................................................... 16 Appendix F: Conducted Spurious Emission ............................................................................. 17 Test Result ........................................................................................................................................... 17 Test Graphs ......................................................................................................................................... 18 Appendix G: Duty Cycle ........................................................................................................... 23 Test Result ........................................................................................................................................... 23 Test Graphs ......................................................................................................................................... 24 Report No. EED32N00003501 Page 3 of 25 Appendix A: DTS Bandwidth Test Result Test Mode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE Ant1 2402 0.668 2401.756 2402.424 0.5 PASS 2440 0.696 2439.756 2440.452 0.5 PASS 2480 0.692 2479.740 2480.432 0.5 PASS Report No. EED32N00003501 Page 4 of 25 Test Graphs BLE_Ant1_2402 BLE_Ant1_2440 Report No. EED32N00003501 Page 5 of 25 BLE_Ant1_2480 Report No. EED32N00003501 Page 6 of 25 Appendix B: Occupied Channel Bandwidth Test Result Test Mode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE Ant1 2402 1.0375 2401.577 2402.614 --- PASS 2440 1.0467 2439.579 2440.626 --- PASS 2480 1.0495 2479.581 2480.631 --- PASS Report No. EED32N00003501 Page 7 of 25 Test Graphs BLE_Ant1_2402 BLE_Ant1_2440 Report No. EED32N00003501 Page 8 of 25 BLE_Ant1_2480 Report No. EED32N00003501 Page 9 of 25 Appendix C: Maximum conducted output power Test Result Test Mode Antenna Channel Result[dBm] Limit[dBm] Verdict BLE Ant1 2402 -0.49 <=30 PASS 2440 -0.53 <=30 PASS 2480 -0.6 <=30 PASS Report No. EED32N00003501 Page 10 of 25 Test Graphs BLE_Ant1_2402 BLE_Ant1_2440 Report No. EED32N00003501 Page 11 of 25 BLE_Ant1_2480 Report No. EED32N00003501 Page 12 of 25 Appendix D: Maximum power spectral density Test Result Test Mode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict BLE Ant1 2402 -9.42 <=8 PASS 2440 -9.39 <=8 PASS 2480 -8.75 <=8 PASS Report No. EED32N00003501 Page 13 of 25 Test Graphs BLE_Ant1_2402 BLE_Ant1_2440 Report No. EED32N00003501 Page 14 of 25 BLE_Ant1_2480 Report No. EED32N00003501 Page 15 of 25 Appendix E: Band edge measurements Test Result Test Mode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE Ant1 Low 2402 -0.83 -45.48 <=-20.83 PASS High 2480 -1.04 -45 <=-21.04 PASS Report No. EED32N00003501 Page 16 of 25 Test Graphs BLE_Ant1_Low_2402 BLE_Ant1_High_2480 Report No. EED32N00003501 Page 17 of 25 Appendix F: Conducted Spurious Emission Test Result Test Mode Antenna Channel FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE Ant1 2402 Reference -1.08 -1.08 --- PASS 30~1000 30~1000 -55.539 <=-21.075 PASS 1000~26500 1000~26500 -45.121 <=-21.075 PASS 2440 Reference -1.06 -1.06 --- PASS 30~1000 30~1000 -56.596 <=-21.062 PASS 1000~26500 1000~26500 -43.054 <=-21.062 PASS 2480 Reference -1.23 -1.23 --- PASS 30~1000 30~1000 -49.286 <=-21.233 PASS 1000~26500 1000~26500 -49.524 <=-21.233 PASS Report No. EED32N00003501 Page 18 of 25 Test Graphs BLE_Ant1_2402_0~Reference BLE_Ant1_2402_30~1000 Report No. EED32N00003501 Page 19 of 25 BLE_Ant1_2402_1000~26500 BLE_Ant1_2440_0~Reference Report No. EED32N00003501 Page 20 of 25 BLE_Ant1_2440_30~1000 BLE_Ant1_2440_1000~26500 Report No. EED32N00003501 Page 21 of 25 BLE_Ant1_2480_0~Reference BLE_Ant1_2480_30~1000 Report No. EED32N00003501 Page 22 of 25 BLE_Ant1_2480_1000~26500 Report N…
Text truncated - open the document above for the full version.
ReportNo.:EED32N00003501Page1of47 1 COVERPAGE TESTREPORT Product:Arm-TypeFullyAutomaticDigital BloodPressureMonitor Trademark: N/A Model/Typereference: DBP-6275B SerialNumber: N/A ReportNumber: EED32N00003501 FCCID:2AQVU0016 DateofIssue:Mar.26,2021 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: JOYTECHHealthcareCo.,Ltd. No.365,WuzhouRoad,Yuhang EconomicDevelopmentZone,Hangzhou City,311100ZhejiangP.R.China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: TomChenAaronMa Approvedby:Date:Mar.26,2021 DavidWang CheckNo.: 4538073830 ReportNo.:EED32N00003501Page 2 of 47 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT.............................................................................................................................................................................2 3VERSION..............................................................................................................................................................................3 4TESTSUMMARY................................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................5 5.3T EST C ONFIGURATION ...................................................................................................................................................7 5.4T EST E NVIRONMENT ......................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................8 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2)..............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA..........................................................................................................11 7.1A NTENNA R EQUIREMENT .............................................................................................................................................11 7.2C ONDUCTED E MISSIONS .............................................................................................................................................12 7.3M AXIMUM C ONDUCTED O UTPUT P OWER ...................................................................................................................16 7.4DTSB ANDWIDTH .........................................................................................................................................................17 7.5M AXIMUM P OWER S PECTRAL D ENSITY ......................................................................................................................18 7.6B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ....................................................................19 7.7R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................20 8APPENDIXA......................................................................................................................................................................35 PHOTOGRAPHSOFTESTSETUP..................................................................................................................................36 PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS.........................................................................................38 ReportNo.:EED32N00003501Page 3 of 47 3Version VersionNo.DateDescription 00 Mar.26,2021 Original ReportNo.:EED32N00003501Page 4 of 47 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 PASS DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32N00003501Page 5 of 47 5GeneralInformation 5.1ClientInformation Applicant: JOYTECHHealthcareCo.,Ltd. AddressofApplicant: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,311100ZhejiangP.R.China Manufacturer: JOYTECHHealthcareCo.,Ltd. AddressofManufacturer: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,311100ZhejiangP.R.China Factory: JOYTECHHealthcareCo.,Ltd. AddressofFactory: No.365,WuzhouRoad,Yuhang…
Text truncated - open the document above for the full version.
ReportNo.:EED32N00003501Page 36 of 47 PHOTOGRAPHSOFTESTSETUP TestmodelNo.:DBP-6275B RadiatedspuriousemissionTestSetup-1 (Below1GHz) RadiatedspuriousemissionTestSetup-2( Above1GHz) ReportNo.:EED32N00003501Page 37 of 47 ConductedEmissionsTestSetup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 900.00 µW |
Digital Thermometer
Equipment Class
DTS - Digital Transmission SystemAir purifier
Equipment Class
DTS - Digital Transmission SystemArm-type Fully Automatic Digital Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission SystemArm-type Fully Automatic Digital Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Infrared Ear Thermometer
Equipment Class
DTS - Digital Transmission System