Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Owner's Manual Infrared Ear Thermometer Model DET-1026b ContentsIntroduction 1 2 Document No.: JDET-3004-005 Article No.: 002 Version: Z Date of Issue: XXXX.XX Telephone: +86-571-81957767 Fax: +86-571-81957750 JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, Hangzhou , Zhejiang 311100 China Made in China Please read all instructions carefully and thoroughly before using this product. The DET-1026b thermometer is specifically designed for safe use in the eardrum. The Infrared Ear Thermometer is a device capable of measuring people's body temperature by detecting the intensity of infrared light emitted from the ear canal of human. It converts the measured heat into a temperature reading displayed on the LCD. When properly used, it will quickly assess your temperature in an accurate manner. Indications for Use:The infrared ear thermometer is intended for the intermittent measurement of human body temperature.The device can be reused by people of all ages for home use and clinical use. Intended use:The infrared ear thermometer is used to measure body temperature. This appliance conforms to the following standards: ASTM E1965-98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature, ISO 80601-2-56 Medical electrical equipment —Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement, IEC 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and essential performance –Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment and complies with the requirements of IEC 60601-1-2(EMC) , AAMI ANSI ES60601-1(Safety) standards. And the manufacturer is ISO 13485 certified. Introduction ..................................................02 Warning ..................................................03 Product Description ....................................... 04 LCD Display Introduction ..................................... 05 Basic Functions .......................................... 06 Ear Thermometer Advantages ..................... 07 Body Temperature ........................................09 Real Time Clock Setting ..............................10 Illustration For Use ...................................12 Temperature Taking Hints .........................18 Memory Mode ...........................................20 Care And Cleaning ...................................21 Battery Replacement ...................................23 Specifications ...........................................24 Troubleshooting ......................................25 Calibration ......................................................27 Symbol Explanation Service ......................................................29 Warranty ........................................................30 Electromagnetic Compatibility Information ...........33 .. FCC Information ..................................................28 ..............................................31 Product Description 1. Probe Cover 2. Probe 3. Test Button/Power Button 4. Memory Button 5. Setting Button/Sound Button 6. Battery Cover 3 6 Basic Functions LCD Display Introduction 4 5 AM and PM Voltage sign Probe cover sign Ear temperature mode Temperature indictor Unit sign: °C or °F Temperature result Time and date sign in Time mode Memory mode Object temperature mode Sound sign Bluetooth Sign Warning It's not meant to replace a visit to the doctor. Please consult with doctor if you have health concerns. 2. There is no gender or age limitation for using infrared ear thermometer. 3. To avoid inaccurate readings, always attach a new, clean probe cover for each temperature reading. 4. Do not expose the thermometer to temperature extremes (below -25°C/-13°F or over 55°C/131°F) nor excessive humidity (>95%RH). 5. This thermometer must only be used with this brand thermometer probe covers. 6. Keep the battery away from children. 7.Remove battery from the device when not in operation for a long time. 8.Do not put the thermometer in direct sunlight or with cotton wool, otherwise the accuracy will be affected. 9.Portable and mobile RF communications can affect the devise. The device needs special precaution regarding EMC according to the EMC information provided in the accompany documents. 10.ME equipment should not be cleaned while in use. 11.Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established. 12.The probe of the ME equipment shall not be serviced or maintained while in use with a patient. 1. Real Time Clock Ear Temperature Mode Object Temperature Mode Memory Mode / Switch°C°F Probe cover detection and eject function The thermometer has been designed for use with or without probe cover. Users can press the eject button to remove the probe cover. SwitchSound You can use the button to choose whether to turn on or off the sound. Bluetooth sign If the APP is successfully connected to the machine,the Bluetooth sign will always be on, otherwise it will keep flashing. The machine can store up to 30 sets of measurements. Each memory also records the measurement results date/time/mode. When the data exceeds 30 sets, the coverage starts from the earliest data. Beep Hint When the testing is done, it will sound one short beep. The real time clock will be recorded with the memory function and help you to recognize each measurement result. → Please see the Real time clock setting section to learn how to setup the time in the first use. The thermometer has been designed for practical use. It's not meant to replace a visit to the doctor. Please also remember to compare the measurement result to your regular body temperature. →Please see the Illustration For Use section to lear…
Text truncated - open the document above for the full version.
ReportNo.:EED32P81026701Page 36 of 43 10PHOTOGRAPHSOFEUTConstructionalDetails ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32P81026701Page 37 of 43 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32P81026701Page 38 of 43 ViewofProduct-5 ViewofProduct-6
DET1026b DET1026b表体标签 JDET-3004-004 Z JDET-3004-004 Z Model:DET-1026b 1 2 1 7 . 0 23.0 Infrared Ear Thermometer Measuring site: ear canal Reference body site:Oral Date of Manufacture:2023.04.25 FCC ID:2AQVU0043 Manufactured by JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,YuhangEconomic DevelopmentZone, Hangzhou , Zhejiang 311100 China 230425 Rating:DC3.0V(2xAAA alkaline battery)
ReportNo.:EED32P81026701Page 39 of 43 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32P81026701Page 40 of 43 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32P81026701Page 41 of 43 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32P81026701Page 42 of 43 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32P81026701Page 43 of 43 ViewofProduct-15 ViewofProduct-16 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***
ReportNo.:EED32P81026702Page1of7 1COVERPAGE RFExposureEvaluationReport Product:InfraredEarThermometer Trademark:N/A Model/Typereference:DET-1026b SerialNumber:N/A ReportNumber:EED32P81026702 FCCID: 2AQVU0043 DateofIssue:Aug.29,2023 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1091 47CFRPart2.1093 447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: JOYTECHHealthcareCo.,Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChen TomChen Approvedby:Date:Aug.29,2023 AaronMa CheckNo.:2727060723 ReportNo.:EED32P81026702Page2of7 2Version VersionNo.DateDescription 00Aug.29,2023Original ReportNo.:EED32P81026702Page3of7 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION............................................................................................................................................................................2 3CONTENTS........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ...................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT...................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ...........................................................................................4 4.4T EST L OCATION .............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS ......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ................................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT .................................................................................................................6 5.1.1Limits....................................................................................................................................................................6 5.1.2TestProcedure....................................................................................................................................................6 5.1.3EUTRFExposureEvaluation..........................................................................................................................7 ReportNo.:EED32P81026702Page4of7 4GeneralInformation 4.1ClientInformation Applicant: JOYTECHHealthcareCo.,Ltd. AddressofApplicant: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 31100Zhejiang,China Manufacturer: JOYTECHHealthcareCo.,Ltd. AddressofManufacturer: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 31100Zhejiang,China Factory: JOYTECHHealthcareCo.,Ltd. AddressofFactory: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 31100Zhejiang,China 4.2GeneralDescriptionofEUT ProductName:InfraredEarThermometer ModelNo.(EUT): DET-1026b TradeMark: N/A 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange: 2402MHz~2480MHz ModulationType: GFSK TestPowerGrade: Default TestSoftwareofEUT: PhyPlusKit AntennaType: PCBAntenna AntennaGain: -1.37612dBi PowerSupply: BatteryDC3V SampleReceivedDate: Jul.06,2023 SampletestedDate: Jul.06,2023toAug.01,2023 CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32P81026702Page5of7 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32P81026702Page6of7 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 5.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32P81026702Page7of7 5.1.3EUTRFExposureEvaluation ForStandalone: ForBLE Frequency (MHz) Max. Conducted Output power (dBm) Antenna Ga…
Text truncated - open the document above for the full version.
Report No.: RF8230406039-L1-R Page 1 of 10 Antenna Test Report Product Name: Bluetooth Module Report No. : RF8230406039-L1-R Product Model: JMD1102/JMD1105/JMD1106 Security Classification: Open Version:V1.0 Total Page: 10 HAIYUN Laboratory Report Prepared By: Checked By: Approved By: Krain Wu Vic Cai Flank Wang Report No.: RF8230406039-L1-R Page 2 of 10 Antenna Test Report Equipment: Bluetooth Module Model: JMD1102/JMD1105/JMD1106 Applicant: JOYTECH Healthcare Co., Ltd. Applicant address: No.365,Wuzhou Road311100 Hangzhou, Zhejiang ProvincePEOPLE'S REPUBLIC OF CHINA Manufacture: JOYTECH Healthcare Co., Ltd. Address: No.365,Wuzhou Road311100 Hangzhou, Zhejiang ProvincePEOPLE'S REPUBLIC OF CHINA Date of Receipt: Apr 7.2023 Date of Test: Apr 1.2023~May 10.2023 Issue Date: May 10.2023 Tested by: Shenzhen HAIYUN Testing Co., Ltd. Laboratory TEL: 0755-89990666-21508 FAX:0755-26801723 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen HAIYUN Testing Co., Ltd. Laboratory. This document may be altered or revised by Shenzhen HAIYUN Testing Co., Ltd. Laboratory. personnel only, and shall be noted in the revision section of the document. The test results of this report relate only to the tested sample identified in this report. Report No.: RF8230406039-L1-R Page 3 of 10 TABLE OF CONTENTS 1.Purose & Environment .................................................................................................................................. 4 1.1 Purpose ................................................................................................................................................. 4 1.2 Environment ......................................................................................................................................... 4 2.Test photos、Test Condition and DUT Antenna .......................................................................................... 5 2.1 Test photos ............................................................................................................................................ 5 2.2 Test Condition ...................................................................................................................................... 5 2.3 DUT Antenna ....................................................................................................................................... 6 3.2D-3D Radiation pattern ............................................................................................................................... 7 3.1 2D Radiation pattern test results ........................................................................................................... 7 3.2 3D Radiation pattern test results ........................................................................................................... 8 4.Peak Gain ...................................................................................................................................................... 9 3.3 Test results ........................................................................................................................................... 9 Report No.: RF8230406039-L1-R Page 4 of 10 1.Purose & Environment 1.1 Purpose • Meet the electrical performance index; • Confirm the antenna scheme to meet the design requirements; 1.2 Environment • Test Condition: the network analyzer(E5071C) and SATIMO microwave anechoic chamber • Passive measurement results are presented Report No.: RF8230406039-L1-R Page 5 of 10 2.Test photos、Test Condition and DUT Antenna 2.1 Test photos Microwave anechoic chamber 2.2 Test Condition The network Analyzer Report No.: RF8230406039-L1-R Page 6 of 10 2.3 DUT Antenna Antenna Report No.: RF8230406039-L1-R Page 7 of 10 3 2D Radiation pattern 3.1 2D Radiation pattern test results Antenna_2D Report No.: RF8230406039-L1-R Page 8 of 10 3 3D Radiation pattern 3.2 3D Radiation pattern test results Antenna_3D Report No.: RF8230406039-L1-R Page 9 of 10 4 Peak Gain 4.1Test results Antenna_Peak Gain Frequency(MHz) Peak_Gain . dBi 2400 -3.52746 2410 -2.85367 2420 -2.15516 2430 -1.78412 2440 -1.69437 2450 -1.55137 2460 -1.49915 2470 -1.37612 2480 -1.49079 2490 -1.57472 2500 -1.7318 Report No.: RF8230406039-L1-R Page 10 of 10 STATEMENT a) The test report applies only to the specific samples tested under conditions. b) The test report is invalid without the Inspection Seal. c) The test report is invalid without the signature of the test engineer, auditor, Approver. d) The test report is invalid if it is altered or copied. e) Partial replica is prohibited without permission of Shenzhen HAIYUN Testing Co., Ltd. Laboratory f) The test results presented in this report is only valid on the tested samples. g) Objections to this report should be submitted to the inspection organization in 15 days of receipting the report. It is not accepted if overdue. Shenzhen HAIYUN Testing Co., Ltd. Laboratory Address: No. 2 Danzi North Road, Kengzi Street, Pingshan District,Shenzhen,Guangdong, China Tel: 0755-26021222 Fax: 0755-26021723 (END OF REPORT)
ReportNo.:EED32P81026701Page1of35 Appendix:BluetoothLE ReportNo.:EED32P81026701Page2of35 Contents AppendixA:DTSBandwidth.......................................................................................................3 TestResult .........................................................................................................................3 TestGraphs .......................................................................................................................4 AppendixB:OccupiedChannelBandwidth................................................................................7 TestResult .........................................................................................................................7 TestGraphs .......................................................................................................................8 AppendixC:Maximumconductedoutputpower....................................................................11 TestResult .......................................................................................................................11 TestGraphs .....................................................................................................................12 AppendixD:Maximumpowerspectraldensity.......................................................................15 TestResult .......................................................................................................................15 TestGraphs .....................................................................................................................16 AppendixE:Bandedgemeasurements...................................................................................19 TestResult .......................................................................................................................19 TestGraphs .....................................................................................................................20 AppendixF:ConductedSpuriousEmission..............................................................................22 TestResult .......................................................................................................................22 TestGraphs .....................................................................................................................23 AppendixG:DutyCycle............................................................................................................32 TestResult .......................................................................................................................32 TestGraphs .....................................................................................................................33 ReportNo.:EED32P81026701Page3of35 AppendixA:DTSBandwidth TestResult TestModeAntennaFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.6882401.6802402.3680.5PASS 24400.6762439.6882440.3640.5PASS 24800.7082479.6602480.3680.5PASS BLE_2MAnt1 24021.1402401.4482402.5880.5PASS 24401.1402439.4482440.5880.5PASS 24801.0722479.4602480.5320.5PASS ReportNo.:EED32P81026701Page4of35 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P81026701Page5of35 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 ReportNo.:EED32P81026701Page6of35 BLE_2M_Ant1_2480 ReportNo.:EED32P81026701Page7of35 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaFrequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.04902401.49292402.5419------ 24401.05482439.48832440.5431------ 24801.05682479.49102480.5478------ BLE_2MAnt1 24022.04762401.00782403.0554------ 24402.05412439.00532441.0594------ 24802.04352479.00052481.0440------ ReportNo.:EED32P81026701Page8of35 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P81026701Page9of35 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 ReportNo.:EED32P81026701Page10of35 BLE_2M_Ant1_2480 ReportNo.:EED32P81026701Page11of35 AppendixC:Maximumconductedoutputpower TestResult TestModeAntennaFrequency[MHz] Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1MAnt1 24021.16≤30PASS 24400.86≤30PASS 24800.82≤30PASS BLE_2MAnt1 24021.13≤30PASS 24400.86≤30PASS 24800.82≤30PASS ReportNo.:EED32P81026701Page12of35 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P81026701Page13of35 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 ReportNo.:EED32P81026701Page14of35 BLE_2M_Ant1_2480 ReportNo.:EED32P81026701Page15of35 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz]Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-15.01≤8.00PASS 2440-15.01≤8.00PASS 2480-15.19≤8.00PASS BLE_2MAnt1 2402-17.12≤8.00PASS 2440-17.2≤8.00PASS 2480-17.21≤8.00PASS ReportNo.:EED32P81026701Page16of35 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P81026701Page17of35 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 ReportNo.:EED32P81026701Page18of35 BLE_2M_Ant1_2480 ReportNo.:EED32P81026701Page19of35 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChName Frequency [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict BLE_1MAnt1 Low24020.89-35.29≤-19.11PASS High24800.65-43.25≤-19.35PASS BLE_2MAnt1 Low24020.23-34.26≤-19.77PASS High2480-2.52-44.31≤-22.52PASS ReportNo.:EED32P81026701Page20of35 TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 BLE_2M_Ant1_Low_2402 ReportNo.:EED32P81026701Page21of35 BLE_2M_Ant1_High_2480 ReportNo.:EED32P81026701Page22of35 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 2402 Reference0.340.34---PASS 30~1000----48.33≤-19.66PASS 1000~265 00 ----41.43≤-19.66PASS 2440 Reference-0.07-0.07---PASS 30~1000----48.27≤-20.07PASS 1000~265 00 ----40.5≤-20.07PASS 2480 Reference0.210.21---PASS 30~1000----48.44≤-19.79PASS 1000~265 00 ----41.6≤-19.79PASS BLE_2MAnt1 2402 Reference-0.28-0.28---PASS 30~1000----48.44≤-20.28PASS 1000~265 00 ----43.14≤-20.28PASS 2…
Text truncated - open the document above for the full version.
ReportNo.:EED32P81026701Page1of43 1 COVERPAGE TESTREPORT Product:InfraredEarThermometer Trademark:N/A Model/Typereference:DET-1026b SerialNumber:N/A ReportNumber:EED32P81026701 FCCID: 2AQVU0043 DateofIssue:Aug.29,2023 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: JOYTECHHealthcareCo.,Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChen TomChen Approvedby:Date:Aug.29,2023 AaronMa CheckNo.:2727060723 ReportNo.:EED32P81026701Page 2 of 43 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT............................................................................................................................................................................2 3VERSION.............................................................................................................................................................................3 4TESTSUMMARY...............................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT.................................................................................................................................5 5.3T EST C ONFIGURATION ..................................................................................................................................................6 5.4T EST E NVIRONMENT .....................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................7 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2).............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA.........................................................................................................12 7.1A NTENNA R EQUIREMENT ............................................................................................................................................12 7.2M AXIMUM C ONDUCTED O UTPUT P OWER ..................................................................................................................13 7.3DTSB ANDWIDTH ........................................................................................................................................................14 7.4M AXIMUM P OWER S PECTRAL D ENSITY .....................................................................................................................15 7.5B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ...................................................................16 7.6R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................17 8APPENDIXBLE................................................................................................................................................................33 9PHOTOGRAPHSOFTESTSETUP..............................................................................................................................34 10PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS...................................................................................36 ReportNo.:EED32P81026701Page 3 of 43 3Version VersionNo.DateDescription 00Aug.29,2023Original ReportNo.:EED32P81026701Page 4 of 43 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 N/A DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS N/A:Onlybatterysupplyissupportedandthisitemisnotconsidered. Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32P81026701Page 5 of 43 5GeneralInformation 5.1ClientInformation Applicant:JOYTECHHealthcareCo.,Ltd. AddressofApplicant:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Manufacturer:JOYTECHHealthcareCo.,Ltd. AddressofManufacturer:No.365,Wuzh…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.30 mW |
Digital Thermometer
Equipment Class
DTS - Digital Transmission SystemAir purifier
Equipment Class
DTS - Digital Transmission SystemArm-type Fully Automatic Digital Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission SystemArm-type Fully Automatic Digital Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Infrared Ear Thermometer
Equipment Class
DTS - Digital Transmission System