FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. JOYTECH HEALTHCARE CO., LTD./
  3. 2AQVU0019

2AQVU0019Infrared Forehead Thermometer

JOYTECH HEALTHCARE CO., LTD.
Infrared Forehead Thermometer - FCC ID 2AQVU0019 - JOYTECH HEALTHCARE CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 17, 2022
Application Purpose
Original Equipment
Date of Application
Jul 17, 2022
Equipment Note
Infrared Forehead Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
JOYTECH HEALTHCARE CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Owner's Manual Infrared Forehead Thermometer Model DET-3018c ContentsIntroduction 12 Please read all instructions carefully and thoroughly before using this product. Indication for Use: The infrared forehead thermometer is a non-contact infrared thermometer intended for the intermittent measurement of human body temperature from forehead at a distance of 1~5cm by people of all ages. This thermometer is reusable for home use and clinical use and can be reused by many people. The DET-3018c infrared forehead thermometer is specifically designed for safe use on the forehead. The Infrared Forehead Thermometer is a device capable of measuring people's body temperature by detecting the intensity of infrared light emitted from the forehead. It converts the measured heat into a temperature reading displayed on the LCD. When properly used, it will quickly assess your temperature in an accurate manner. Introduction ........................................................02 Warning ....................................................................03 Product Description ................................................. 04 LCD Display Introduction ....................................... 05 Basic Functions ................................................... 06 Forehead Thermometer Advantages ......................... 07 Real Time Clock Setting ......................................08 Temperature Taking Hints ...................................11 Illustration For Use ..............................................13 Memory Mode ........................................................18 Care And Cleaning ...............................................19 Battery Replacement ............................................20 Specifications .....................................................21 Troubleshooting ...................................................22 Calibration ...........................................................24 Symbol Explanation ...........................................25 Service ...............................................................26 Warranty ...............................................................27 Information Electromagnetic Compatibility Information ...............30 FCC ..........................................................28 Document No.: Article No.: Version: Date of Issue: JDET-1804-011 004 2021-11 Z This appliance conforms to the following standards: ASTM E1965-98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature, ISO 80601-2-56 Medical electrical equipment —Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement, IEC 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and essential performance –Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment and complies with the requirements of IEC 60601-1-2(EMC) , AAMI ANSI ES60601-1(Safety) standards. And the manufacturer is ISO 13485 certified. Telephone: +86-571-81957767 Fax: +86-571-81957750 JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, Hangzhou , Zhejiang 311100 China Made in China Product Description 3 Basic Functions 4 6 5 forehead thermometer. 2. Do not touch the temperature probe with hands. 3. Use of this Forehead thermometer is not intended as a substitute for consultation with your physician. 4. Do not allow children to take their temperatures unsupervised, some parts are small enough to be swallowed. 5. Never immerse this device in water or other liquids(not waterproof ). 6. Do not modify this equipment without authorization of manufacturer. 7. Do not expose the thermometer to temperature extremes (below -25°C/-13°F or over 55°C/131°F) nor excessive humidity (>95%RH). 8. Keep the battery away from children. 12.ME equipment should not be cleaned and disinfected while in use. 1. There is no gender or age limitation for using infrared 9.Remove battery from the device when not in operation for a long time. 10.Do not put the thermometer in direct sunlight or with cotton wool, otherwise the accuracy will be affected. 11. Portable and mobile RF communications can affect the devise. The device needs special precaution regarding EMC according to the EMC information provided in the accompany documents. Warning LCD Display Introduction 1. Probe 2. Test Button 3. Voice Switch 4. Setting Button 5. Battery Cover 6. Display 1 2 3 4 5 6 Object mode Voice sign AM and PM Low voltage sign Forehead mode Unit sign: °C or °F Temperature result Time and Date sign in Time mode Memory mode Bluetooth sign Bluetooth sign If the APP is successfully connected to the machine,the Bluetooth sign will always be on, otherwise it will keep flashing. Real Time Clock Forehead Mode Object Mode Memory Mode There are 30 sets memories for forehead and object measurements. Each memory also records the measurement date/time/mode icon. / Switch°C°F Please see the Real Time Clock Setting to learn how to change between Celsius and Fahrenheit. The real time clock will be recorded with the memory function and help you to recognize each measurement result. → Please see the Real time clock setting section to learn how to setup the time in the first use. The thermometer has been designed for practical use. It's not meant to replace a visit to the doctor. Please also remember to compare the measurement result to your regular body temperature. → Please see the Illustration For Use section to learn how to measure the body temperature. The object mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for example the baby's milk. → Please see the Illustration For Use section to learn how to measure the object temperature. Voice The the…

Text truncated - open the document above for the full version.

External Photos

ReportNo.:EED32O80625101Page 35 of 45 10PHOTOGRAPHSOFEUTConstructionalDetails TestmodelNo.:DET-3018c ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32O80625101Page 36 of 45 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32O80625101Page 37 of 45 ViewofProduct-5 ViewofProduct-6 ReportNo.:EED32O80625101Page 38 of 45 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32O80625101Page 39 of 45 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32O80625101Page 40 of 45 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32O80625101Page 41 of 45 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32O80625101Page 42 of 45 ViewofProduct-15 ViewofProduct-16

ID Label/Location Info

Infrared Forehead Thermometer Model:DET-3018c Measuring site:Forehead Reference body site:Oral Manufactured by JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,Yuhang EconomicDevelopmentZone, Hangzhou , Zhejiang 311100 China Battery: DC3.0V, 2xAAA Date of Manufacture:XXXXXX FCC ID:2AQVU0019 DET-3018c DET3018c表体标签(FDA) JDET-1804-010 Z JDET-1804-010 Z size:20*25mm

Internal Photos

ReportNo.:EED32O80625101Page 42 of 45 ViewofProduct-15 ViewofProduct-16 ReportNo.:EED32O80625101Page 43 of 45 ViewofProduct-17 ViewofProduct-18 ReportNo.:EED32O80625101Page 44 of 45 ViewofProduct-19 ViewofProduct-20 ReportNo.:EED32O80625101Page 45 of 45 ViewofProduct-21 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***

RF Exposure Info

ReportNo.:EED32O80625102Page1of8 1COVERPAGE RFExposureEvaluationReport Product:InfraredForeheadThermometer Trademark:N/A Model/Typereference:DET-3018c,DET-3018b SerialNumber:N/A ReportNumber:EED32O80625102 FCCID:2AQVU0019 DateofIssue:Jul.14,2022 TestStandards: 47CFRPart1.1307 47CFRPart2.1093 KDB447498D01GeneralRF ExposureGuidancev06 Testresult:PASS Preparedfor: JOYTECHHEALTHCARECO.,LTD No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,311100Zhejiang,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChenTomChen Approvedby:Date:Jul.14,2022 AaronMa CheckNo.:7954070522 ReportNo.:EED32O80625102Page2of8 2Version VersionNo.DateDescription 00Jul.14,2022Original ReportNo.:EED32O80625102Page3of8 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION.............................................................................................................................................................................2 3CONTENTS.........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ....................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT....................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ...........................................................................................4 4.4T EST L OCATION ..............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS .......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ...........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER .................................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT ..................................................................................................................6 5.1.1StandardRequirement......................................................................................................................................6 5.1.2Limits....................................................................................................................................................................6 5.1.3EUTRFExposure..............................................................................................................................................7 ReportNo.:EED32O80625102Page4of8 4GeneralInformation 4.1ClientInformation Applicant: JOYTECHHEALTHCARECO.,LTD. AddressofApplicant: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100Zhejiang,China Manufacturer: JOYTECHHEALTHCARECO.,LTD. AddressofManufacturer: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100Zhejiang,China Factory: JOYTECHHEALTHCARECO.,LTD. AddressofFactory: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100Zhejiang,China 4.2GeneralDescriptionofEUT ProductName:InfraredForeheadThermometer ModelNo.:DET-3018c,DET-3018b TestModelNo.(EUT): DET-3018c TradeMark: N/A 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:PhyPlusKit AntennaType:PCBAntenna AntennaGain:0dBi PowerSupply:DC3V MaxConductedPeak OutputPower: 0.59dBm TheMaxConductedPeakOutputPowerdatarefertothereportEED32O80625101 SampleReceivedDate: May17,2022 SampletestedDate: May17,2022toJul.12,2022 CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ModelNo.:DET-3018c,DET-3018b OnlythemodelDET-3018cwastested.theirelectricalcircuitdesign,layout,componentsusedandinternal wiringareidentical.ThedifferenceisthattheDET-3018bhasdistancedetection,DET-3018chasindicatorlight. ReportNo.:EED32O80625102Page5of8 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32O80625102Page6of8 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurementor numericalsimulation,isnotrequiredwhenthecorrespondingSARExclusionThresholdcondition,listed below,issatisfied. 5.1.2Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparationdistances ≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparation…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32O80625101Page1of34 Appendix:BluetoothLE ReportNo.:EED32O80625101Page2of34 Contents Contents..............................................................................................................................................................................2 DutyCycle...........................................................................................................................................................................3 MaximumPeakConductedOutputPower....................................................................................................................7 -6dBBandwidth................................................................................................................................................................11 OccupiedChannelBandwidth.......................................................................................................................................15 MaximumPowerSpectralDensityLevel.....................................................................................................................19 BandEdge........................................................................................................................................................................23 ConductedRFSpuriousEmission................................................................................................................................28 ReportNo.:EED32O80625101Page3of34 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant164.21.922.46 NVNTBLE1M2440Ant164.21.922.46 NVNTBLE1M2480Ant165.861.812.46 NVNTBLE2M2402Ant134.474.634.69 NVNTBLE2M2440Ant133.64.744.69 NVNTBLE2M2480Ant134.474.634.69 ReportNo.:EED32O80625101Page4of34 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O80625101Page5of34 DutyCycleNVNTBLE1M2480MHzAnt1 DutyCycleNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O80625101Page6of34 DutyCycleNVNTBLE2M2440MHzAnt1 DutyCycleNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O80625101Page7of34 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower(dBm)Limit (dBm) Verdict NVNTBLE 1M 2402Ant10.5900.5930Pass NVNTBLE 1M 2440Ant10.1300.1330Pass NVNTBLE 1M 2480Ant1-0.520-0.5230Pass NVNTBLE 2M 2402Ant10.5900.5930Pass NVNTBLE 2M 2440Ant10.1400.1430Pass NVNTBLE 2M 2480Ant1-0.530-0.5330Pass ReportNo.:EED32O80625101Page8of34 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O80625101Page9of34 PeakPowerNVNTBLE1M2480MHzAnt1 PeakPowerNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O80625101Page10of34 PeakPowerNVNTBLE2M2440MHzAnt1 PeakPowerNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O80625101Page11of34 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.6830.5Pass NVNTBLE1M2440Ant10.6890.5Pass NVNTBLE1M2480Ant10.7380.5Pass NVNTBLE2M2402Ant11.1470.5Pass NVNTBLE2M2440Ant11.1470.5Pass NVNTBLE2M2480Ant11.160.5Pass ReportNo.:EED32O80625101Page12of34 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O80625101Page13of34 -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O80625101Page14of34 -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O80625101Page15of34 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.031 NVNTBLE1M2440Ant11.037 NVNTBLE1M2480Ant11.047 NVNTBLE2M2402Ant12.049 NVNTBLE2M2440Ant12.048 NVNTBLE2M2480Ant12.05 ReportNo.:EED32O80625101Page16of34 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O80625101Page17of34 OBWNVNTBLE1M2480MHzAnt1 OBWNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O80625101Page18of34 OBWNVNTBLE2M2440MHzAnt1 OBWNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O80625101Page19of34 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) DutyFactor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE 1M 2402Ant1-15.20-15.28Pass NVNTBLE 1M 2440Ant1-15.750-15.758Pass NVNTBLE 1M 2480Ant1-15.450-15.458Pass NVNTBLE 2M 2402Ant1-17.10-17.18Pass NVNTBLE 2M 2440Ant1-17.810-17.818Pass NVNTBLE 2M 2480Ant1-18.190-18.198Pass ReportNo.:EED32O80625101Page20of34 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1

Test Report

ReportNo.:EED32O80625101Page21of34 PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O80625101Page22of34 PSDNVNTBLE2M2440MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O80625101Page23of34 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-46.16-20Pass NVNTBLE1M2480Ant1-45.17-20Pass NVNTBLE2M2402Ant1-36.36-20Pass NVNTBLE2M2480Ant1-45.19-20Pass ReportNo.:EED32O80625101Page24of34 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O80625101Page25of34 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32O80625101Page26of34 BandEdgeNVNTBLE2M2402MHzAnt1Ref BandEdgeNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32O80625101Page27of34 BandEdgeNVNTBLE2M2480MHzAnt1Ref BandEdgeNVNTBLE2M2480MHzAnt1Emission ReportNo.:EED32O80625101Page28of34 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-40.85-20Pass NVNTBLE1M2440Ant1-44.14-20Pass NVNTBLE1M2480Ant1-38.93-20Pass NVNTBLE2M2402Ant1-48.58-20Pass NVNTBLE2M2440Ant1-40.48-20Pass NVNTBLE2M2480Ant1-39.71-20Pass ReportNo.:EED32O80625101Page29of34 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O80625101Page30of34 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32O80625101Page31of34 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32O80625101Page32of34 Tx.SpuriousNVNTBLE2M2402MHzAnt1Ref Tx.SpuriousNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32O80625101Page33of34 Tx.SpuriousNVNTBLE2M2440MHzAnt1Ref Tx.SpuriousNVNTBLE2M2440MHzAnt1Emission ReportNo.:EED32O80625101Page34of34 Tx.SpuriousNVNTBLE2M2480MHzAnt1Ref Tx.SpuriousNVNTBLE2M2480MHzAnt1Emission ***EndofReport***

Test Report

ReportNo.:EED32O80625101Page1of45 1 COVERPAGE TESTREPORT Product:InfraredForeheadThermometer Trademark:N/A Model/Typereference:DET-3018c,DET-3018b SerialNumber:N/A ReportNumber:EED32O80625101 FCCID:2AQVU0019 DateofIssue:Jul.14,2022 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: JOYTECHHEALTHCARECO.,LTD No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,311100Zhejiang,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChenTomChen Approvedby:Date:Jul.14,2022 AaronMa CheckNo.:7954070522 ReportNo.:EED32O80625101Page 2 of 45 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT.............................................................................................................................................................................2 3VERSION..............................................................................................................................................................................3 4TESTSUMMARY................................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................5 5.3T EST C ONFIGURATION ...................................................................................................................................................6 5.4T EST E NVIRONMENT ......................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................7 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2)..............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA..........................................................................................................11 7.1A NTENNA R EQUIREMENT .............................................................................................................................................11 7.2M AXIMUM C ONDUCTED O UTPUT P OWER ...................................................................................................................12 7.3DTSB ANDWIDTH .........................................................................................................................................................13 7.4M AXIMUM P OWER S PECTRAL D ENSITY ......................................................................................................................14 7.5B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ....................................................................15 7.6R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................16 8APPENDIXA......................................................................................................................................................................32 9PHOTOGRAPHSOFTESTSETUP..............................................................................................................................33 10PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS....................................................................................35 ReportNo.:EED32O80625101Page 3 of 45 3Version VersionNo.DateDescription 00Jul.14,2022Original ReportNo.:EED32O80625101Page 4 of 45 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 N/A DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ModelNo.:DET-3018c,DET-3018b OnlythemodelDET-3018cwastested.theirelectricalcircuitdesign,layout,componentsusedandinternal wiringareidentical.ThedifferenceisthattheDET-3018bhasdistancedetection,DET-3018chasindicatorlight. ReportNo.:EED32O80625101Page 5 of 45 5GeneralInformation 5.1ClientInformation Applicant:JOYTECHHEALTHCARECO.,LTD. AddressofApplicant:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,311100Zhejiang,China Manufacturer:JOYTECHHEALTHCARECO.,LTD. AddressofManufacturer:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,311100Zhejiang,China Factory:JOYTECHHEALTHCARECO.,LTD. AddressofFactory:No.365,WuzhouRoad…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:EED32O80625101Page 33 of 45 9PHOTOGRAPHSOFTESTSETUP TestmodelNo.:DET-3018c RadiatedspuriousemissionTestSetup-1 (Below1GHz) RadiatedspuriousemissionTestSetup-2( Above1GHz) ReportNo.:EED32O80625101Page 34 of 45 RadiatedspuriousemissionTestSetup-3( Above1GHz) Thereareabsorbingmaterialsundertheground.

Contact Information

Applicant

Lan Yingting(QA)
[email protected]0571-81957767Fax: 0571-81957750

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power.

Other Applications from JOYTECH HEALTHCARE CO., LTD.

2AQVU0050

Digital Thermometer

Dec 03, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU-AP301AW

Air purifier

Aug 23, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0049

Arm-type Fully Automatic Digital Blood Pressure Monitor

Aug 07, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0046

Arm-type Fully Automatic Digital Blood Pressure Monitor

Jan 21, 2024

Equipment Class

DTS - Digital Transmission System
Infrared Ear Thermometer - FCC ID 2AQVU0043 - JOYTECH HEALTHCARE CO., LTD.
2AQVU0043

Infrared Ear Thermometer

Sep 02, 2023

Equipment Class