FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. JOYTECH HEALTHCARE CO., LTD./
  3. 2AQVU0031

2AQVU0031Infrared Forehead Thermometer

JOYTECH HEALTHCARE CO., LTD.
Infrared Forehead Thermometer - FCC ID 2AQVU0031 - JOYTECH HEALTHCARE CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 06, 2022
Application Purpose
Original Equipment
Date of Application
Dec 06, 2022
Equipment Note
Infrared Forehead Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
JOYTECH HEALTHCARE CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Owner's Manual Infrared Forehead Thermometer Model DET-30b23 ContentsIntroduction 12 Please read all instructions carefully and thoroughly before using this product. The DET-3023b infrared forehead thermometer is specifically designed for safe use on the forehead. The Infrared Forehead Thermometer is a device capable of measuring people's body temperature by detecting the intensity of infrared light emitted from the forehead. It converts the measured heat into a temperature reading displayed on the LED display. When properly used, it will quickly assess your temperature in an accurate manner. Indications for Use:The infrared forehead thermometer is intended for the intermittent measurement of human body temperature from the skin surface of forehead. The device can be reused by people of all ages for home use and clinical use. Intended use:The infrared forehead thermometer is used to measure body temperature by measuring forehead. Introduction ........................................................02 Warning ....................................................................03 Product Description ................................................. 04 LD Display Introduction ....................................... 05 Basic Functions ................................................... 06 Forehead Thermometer Advantages ......................... 07 ....................................................................08 Temperature Taking Hints ...................................09 Illustration For Use ..............................................11 Memory Mode ........................................................16 Care And Cleaning ...............................................17 Battery Replacement ............................................18 Specifications .....................................................19 Troubleshooting ...................................................20 Calibration ...........................................................22 Symbol Explanation ...........................................23 Service ...............................................................24 Warranty ...............................................................25 Information Electromagnetic Compatibility Information ...............28 E Setting FCC ..........................................................26 Document No.: JDET-2704-005 Article No.: 002 Version: Z Date of Issue: 20XX-XX This appliance conforms to the following standards: ASTM E1965-98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature, ISO 80601-2-56 Medical electrical equipment —Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement, IEC 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and essential performance –Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment and complies with the requirements of IEC 60601-1-2(EMC) , AAMI ANSI ES60601-1(Safety) standards. And the manufacturer is ISO 13485 certified. Telephone: +86-571-81957767 Fax: +86-571-81957750 JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, Hangzhou , Zhejiang 311100 China Made in China Product Description 3 Basic Functions LED Display Introduction 4 6 5 Warning Bluetooth sign If the APP is successfully connected to the machine,the Bluetooth sign will always be on, otherwise it will keep flashing. Forehead Mode Object Mode Memory Mode There are each 30 sets memories for forehead and object measurements. Each memory also records the measurement mode icon. / Switch°C°F Please see the to learn how to change between Celsius and Fahrenheit. Setting The thermometer has been designed for practical use. It's not meant to replace a visit to the doctor. Please also remember to compare the measurement result to your regular body temperature. → Please see the Illustration For Use section to learn how to measure the body temperature. The object mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for example the baby's milk. → Please see the Illustration For Use section to learn how to measure the object temperature. Language SwitchLanguage Switch Please see the Setting to learn how to change between Chinese and English. Voice The thermometer will broadcast the result after finishing measurement. Sound Switch The thermometer can turn on or off sound. →Please see the Illustration For Use. 1. Probe 2. Test Button 3. 4. Setting Button 5. Battery Cover 6. Memory Switch Display 1 2 3 4 5 6 forehead thermometer. 2. Do not touch the temperature probe with hands . 3. Use of this Forehead thermometer is not intended as a substitute for consultation with your physician. 4. Do not allow children to take their temperatures unsupervised, some parts are small enough to be swallowed. 5. Never immerse this device in water or other liquids. 6. Do not modify this equipment without authorization of manufacturer. 7. Do not expose the thermometer to temperature extremes (below -25°C/-13°F or over 55°C/131°F) nor excessive humidity (>95%RH). 8. Keep the battery away from children. 9.Remove battery from the device when not in operation for a long time. 10.Do not put the thermometer in direct sunlight or with cotton wool, otherwise the accuracy will be affected. 11.Portable and mobile RF communications can affect the devise. The device needs special precaution regarding EMC according to the EMC information provided in the accompany documents 12.ME equipment should not be cleaned and wiped while in use. 13.Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user an…

Text truncated - open the document above for the full version.

External Photos

Report No. : EED32O81456301Page 36 of 44 10 PHOTOGRAPHS OF EUT Constructional Details Test model No.: DET-3023b View of Product-1 View of Product-2 Report No. : EED32O81456301Page 37 of 44 View of Product-3 View of Product-4 Report No. : EED32O81456301Page 38 of 44 View of Product-5 View of Product-6 Report No. : EED32O81456301Page 39 of 44 View of Product-7 View of Product-8 Report No. : EED32O81456301Page 40 of 44 View of Product-9

ID Label/Location Info

Infrared Forehead Thermometer Model:DET-3023b DET3023b DET3023b表体标签(FDA) JDET-2704-004 Z JDET-2704-004 Z 1 2 1 7 . 0 23.0 Measuring site:Forehead Reference body site:Oral Battery: DC3.0V, 2xAAA Date of Manufacture:2022.06.22 FCC ID:2AQVU0031 220622 Manufactured by JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,Yuhang Economic DevelopmentZone, Hangzhou , Zhejiang 311100 China

Internal Photos

Report No. : EED32O81456301Page 40 of 46 View of Product-9 View of Product-10 Report No. : EED32O81456301Page 41 of 46 View of Product-11 View of Product-12

Internal Photos

Report No. : EED32O81456301Page 42 of 46 View of Product-13 View of Product-14 Report No. : EED32O81456301Page 43 of 46 View of Product-15 View of Product-16

Internal Photos

Report No. : EED32O81456301Page 44 of 46 View of Product-17 View of Product-18

Internal Photos

Report No. : EED32O81456301Page 45 of 46 View of Product-19 View of Product-20 Report No. : EED32O81456301Page 46 of 46 View of Product-21 View of Product-22 The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CTI, this report can’t be reproduced except in full. *** End of Report ***

RF Exposure Info

ReportNo. : EED32O81456302Page 1 of 7 1 C OVERPAGE RF Ex posureEvaluationReport Product:In frared ForeheadThermometer Trademark:N/A Model/Typereference:DET-3023b SerialNumber:N/A ReportNumber:EED32O81456302 FCCID:2AQVU0031 Dateof Issue:Dec. 06, 2022 TestStandards: 47 CFR Part 1.1307 47 CFR Part 1.13 10 47 CFR Part 2.1093 447498D04 Interim GeneralRF ExposureGuidancev01 Testresult:PASS Prepa red for: JOYT ECHHEALTHCARECO.,LTD. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,311100Zhejiang,China Prepa red by : C entreTestingInternationalGroupCo., Ltd. HongweiIndustrialZone,Bao ’an 70 District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiled by:Reviewedby: Mark ChenTom Chen Approvedby:Date:Dec. 06,2022 Aaron Ma C heck No.: 7011150922 ReportNo.:EED32O81456302Page2of7 2Version VersionNo.DateDescription 00Dec.06,2022Original ReportNo.:EED32O81456302Page3of7 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION............................................................................................................................................................................2 3CONTENTS........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ...................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT...................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ...........................................................................................4 4.4T EST L OCATION .............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS ......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ................................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT .................................................................................................................6 5.1.1Limits....................................................................................................................................................................6 5.1.2TestProcedure....................................................................................................................................................6 5.1.3EUTRFExposureEvaluation..........................................................................................................................7 ReportNo.:EED32O81456302Page4of7 4GeneralInformation 4.1ClientInformation Applicant:JOYTECHHEALTHCARECO.,LTD. AddressofApplicant:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100Zhejiang,China Manufacturer:JOYTECHHEALTHCARECO.,LTD. AddressofManufacturer:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100Zhejiang,China Factory:JOYTECHHEALTHCARECO.,LTD. AddressofFactory:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, 311100Zhejiang,China 4.2GeneralDescriptionofEUT ProductName:InfraredForeheadThermometer ModelNo.(EUT): DET-3023b TradeMark: N/A Devicetype: Portabledevice 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:PhyPluskit AntennaType:PCBantenna AntennaGain:0dBi PowerSupply:DC3.0V SampleReceivedDate: Oct.08,2022 SampletestedDate: Oct.08,2022toOct.31,2022 Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32O81456302Page5of7 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32O81456302Page6of7 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 5.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32O81456302Page7of7 5.1.3EUTRFExposureEvaluation ForStandalone: ForBLE Frequency …

Text truncated - open the document above for the full version.

Test Report

Bluetoothantennaspecifications 蓝牙天线规格 ShanghaiXinganMicroelectronicsTechnologyCo.,Ltd 上海芯感微电子科技有限公司 Allrightsreserved 版权所有不得复制 1 : AntennaDescription AntennaTypeMicrotripAntenna Antennapeakgain 0dBi Frequencyrange 2.402GHz~2.480GHz Connecttype Simulation 2 : AntennapictureonthePCBborad 3 : Antennaradiationof3Dpolar Solutionfrequencyat2.453G 3:Antenneradiationpattern

Test Report

ReportNo.:EED32O81456301Page 1 of 34 Appendix:BluetoothLE ReportNo.:EED32O81456301Page 2 of 34 Contents Contents.....................................................................................................................................................................................................2 DutyCycle..................................................................................................................................................................................................3 MaximumPeakConductedOutputPower..................................................................................................................................................7 -6dBBandwidth........................................................................................................................................................................................11 OccupiedChannelBandwidth..................................................................................................................................................................15 MaximumPowerSpectralDensityLevel..................................................................................................................................................19 BandEdge................................................................................................................................................................................................23 ConductedRFSpuriousEmission............................................................................................................................................................28 ReportNo.:EED32O81456301Page 3 of 34 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant165.71.822.46 NVNTBLE1M2440Ant165.861.812.46 NVNTBLE1M2480Ant164.21.922.46 NVNTBLE2M2402Ant133.64.744.69 NVNTBLE2M2440Ant133.524.754.71 NVNTBLE2M2480Ant134.394.644.71 ReportNo.:EED32O81456301Page 4 of 34 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81456301Page 5 of 34 DutyCycleNVNTBLE1M2480MHzAnt1 DutyCycleNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81456301Page 6 of 34 DutyCycleNVNTBLE2M2440MHzAnt1 DutyCycleNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81456301Page 7 of 34 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) Limit (dBm) Verdict NVNTBLE1M2402Ant1-0.9830Pass NVNTBLE1M2440Ant1-2.6430Pass NVNTBLE1M2480Ant1-3.4530Pass NVNTBLE2M2402Ant1-0.4130Pass NVNTBLE2M2440Ant1-1.8230Pass NVNTBLE2M2480Ant1-3.0930Pass ReportNo.:EED32O81456301Page 8 of 34 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81456301Page 9 of 34 PeakPowerNVNTBLE1M2480MHzAnt1 PeakPowerNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81456301Page 10 of 34 PeakPowerNVNTBLE2M2440MHzAnt1 PeakPowerNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81456301Page 11 of 34 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.7390.5Pass NVNTBLE1M2440Ant10.7150.5Pass NVNTBLE1M2480Ant10.7430.5Pass NVNTBLE2M2402Ant11.2750.5Pass NVNTBLE2M2440Ant11.2760.5Pass NVNTBLE2M2480Ant11.2710.5Pass ReportNo.:EED32O81456301Page 12 of 34 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81456301Page 13 of 34 -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81456301Page 14 of 34 -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81456301Page 15 of 34 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.038 NVNTBLE1M2440Ant11.032 NVNTBLE1M2480Ant11.036 NVNTBLE2M2402Ant12.02 NVNTBLE2M2440Ant12.023 NVNTBLE2M2480Ant12.026 ReportNo.:EED32O81456301Page 16 of 34 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81456301Page 17 of 34 OBWNVNTBLE1M2480MHzAnt1 OBWNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81456301Page 18 of 34 OBWNVNTBLE2M2440MHzAnt1 OBWNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81456301Page 19 of 34 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) DutyFactor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE1M2402Ant1-11.510-11.518Pass NVNTBLE1M2440Ant1-12.850-12.858Pass NVNTBLE1M2480Ant1-13.930-13.938Pass NVNTBLE2M2402Ant1-16.10-16.18Pass NVNTBLE2M2440Ant1-17.430-17.438Pass NVNTBLE2M2480Ant1-18.720-18.728Pass ReportNo.:EED32O81456301Page 20 of 34 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81456301Page 21 of 34 PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81456301Page 22 of 34 PSDNVNTBLE2M2440MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81456301Page 23 of 34 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-42.94-20Pass NVNTBLE1M2480Ant1-40.72-20Pass NVNTBLE2M2402Ant1-36.35-20Pass NVNTBLE2M2480Ant1-41.38-20Pass ReportNo.:EED32O81456301Page 24 of 34 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O81456301Page 25 of 34 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32O81456301Page 26 of 34 BandEdgeNVNTBLE2M2402MHzAnt1Ref BandEdgeNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32O81456301Page 27 of 34 BandEdgeNVNTBLE2M2480MHzAnt1Ref BandEdgeNVNTBLE2M2480MHzAnt1Emission ReportNo.:EED32O81456301Page 28 of 34 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-33.78-20Pass NVNTBLE1M2440Ant1-33.24-20Pass NVNTBLE1M2480Ant1-33.96-20Pass NVNTBLE2M2402Ant1-33.86-20Pass NVNTBLE2M2440Ant1-34.69-20Pass NVNTBLE2M2480Ant1-34.72-20Pass ReportNo.:EED32O81456301Page 29 of 34 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O81456301Page 30 of 34 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32O81456301Page 31 of 34 Tx.SpuriousNVNT…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32O81456301Page1of44 1 COVERPAGE TESTREPORT Product:InfraredForeheadThermometer Trademark:N/A Model/Typereference:DET-3023b SerialNumber:N/A ReportNumber:EED32O81456301 FCCID:2AQVU0031 DateofIssue:Dec.06,2022 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: JOYTECHHEALTHCARECO.,LTD. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,311100Zhejiang,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChenTomChen Approvedby:Date:Dec.06,2022 AaronMa CheckNo.:7011150922 ReportNo.:EED32O81456301Page 2 of 44 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT............................................................................................................................................................................2 3VERSION.............................................................................................................................................................................3 4TESTSUMMARY...............................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT.................................................................................................................................5 5.3T EST C ONFIGURATION ..................................................................................................................................................6 5.4T EST E NVIRONMENT .....................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................7 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2).............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA.........................................................................................................12 7.1A NTENNA R EQUIREMENT ............................................................................................................................................12 7.2M AXIMUM C ONDUCTED O UTPUT P OWER ..................................................................................................................13 7.3DTSB ANDWIDTH ........................................................................................................................................................14 7.4M AXIMUM P OWER S PECTRAL D ENSITY .....................................................................................................................15 7.5B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ...................................................................16 7.6R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................17 8APPENDIXA.....................................................................................................................................................................33 9PHOTOGRAPHSOFTESTSETUP..............................................................................................................................34 10PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS...................................................................................36 ReportNo.:EED32O81456301Page 3 of 44 3Version VersionNo.DateDescription 00Dec.06,2022Original ReportNo.:EED32O81456301Page 4 of 44 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 N/A DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32O81456301Page 5 of 44 5GeneralInformation 5.1ClientInformation Applicant: JOYTECHHEALTHCARECO.,LTD. AddressofApplicant: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,311100Zhejiang,China Manufacturer: JOYTECHHEALTHCARECO.,LTD. AddressofManufacturer: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,311100Zhejiang,China Factory: JOYTECHHEALTHCARECO.,LTD. AddressofFactory: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,311100Zhejiang,China 5.2GeneralDescriptionofEUT ProductName: InfraredForeheadThermometer ModelNo.: DET-3023b Trademark: N/A Devicetype: Portabledevice OperationFrequency:2402MHz~2480MHz Modulati…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:EED32O81456301Page 34 of 44 9PHOTOGRAPHSOFTESTSETUP TestmodelNo.:DET-3023b RadiatedspuriousemissionTestSetup-1 (Below1GHz) RadiatedspuriousemissionTestSetup-2( Above1GHz) ReportNo.:EED32O81456301Page 35 of 44 RadiatedspuriousemissionTestSetup-3( Above1GHz) Thereareabsorbingmaterialsundertheground.

Contact Information

Applicant

Lan Yingting(QA)
[email protected]0571-81957767Fax: 0571-81957750

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz900.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power.

Other Applications from JOYTECH HEALTHCARE CO., LTD.

2AQVU0050

Digital Thermometer

Dec 03, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU-AP301AW

Air purifier

Aug 23, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0049

Arm-type Fully Automatic Digital Blood Pressure Monitor

Aug 07, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0046

Arm-type Fully Automatic Digital Blood Pressure Monitor

Jan 21, 2024

Equipment Class

DTS - Digital Transmission System
Infrared Ear Thermometer - FCC ID 2AQVU0043 - JOYTECH HEALTHCARE CO., LTD.
2AQVU0043

Infrared Ear Thermometer

Sep 02, 2023

Equipment Class

DTS - Digital Transmission System