2AQVU0035Arm-type Fully Automatic Digital Blood Pressure Monitor

JOYTECH HEALTHCARE CO., LTD.
Arm-type Fully Automatic Digital Blood Pressure Monitor - FCC ID 2AQVU0035 - JOYTECH HEALTHCARE CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 19, 2023
Application Purpose
Original Equipment
Date of Application
Feb 19, 2023
Equipment Note
Arm-type Fully Automatic Digital Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
JOYTECH HEALTHCARE CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Contents Safety Notice ............................................................... 02 Unit Illustration ......................................................... 06 Important Testing Guidelines ..................................... 09 Quick Start ................................................................. 10 Unit Operation ........................................................... 11 Blood Pressure Information ........................................ 24 Blood Pressure Q&A ................................................... 27 Maintenance ............................................................... 28 Specifications ............................................................. 30 Warranty .................................................................... 32 Electromagnetic Compatibility Information .............. 33 Additional Notes ........................................................ 37 Battery Installation ........................................... 11 System Settings .................................................. 12 Applying the Arm Cuff ....................................... 14 Testing ................................................................ 15 Power Off .............................................................18 .............19 Memory Deletion ..................................................20 Low Battery Indicator ...........................................20 Bluetooth requirement and connection ...............21 Troubleshooting .....................................................23 Memory Check and Last 3 Test Average Safety Notice Model DBP-62A2B Arm Type 12 Owner's Manual Arm-type Fully Automatic Digital Blood Pressure Monitor Document No. : JDBP-A204-054 Version: Z Date of Issue: 2022.3.4 Arm Type Contact Information The lay operator or lay responsible or ganization should contact the manufacturer or the representative of manufacturer. -for assistance,if needed,in setting up,using or maintaining the product,or -to report unexpected operation or events. Manufactured by JOYTECH Healthcare Co.,Ltd. Email: [email protected] Telephone: +86-571-81957767 Fax: +86-571-81957750 No.365, Wuzhou Road,Yuhang Economic Development Zone, Hangzhou City,311100 Zhejiang,China Thank you for purchasing the DBP-62A2B Blood Pressure Monitor. The unit has been constructed using reliable circuitry and durable materials. Used properly, this unit will provide years of satisfactory use. Indications for use: The Arm-type Fully Automatic Digital Blood Pressure monitors are intended to measure blood pressure(systolic and diastolic) and pulse rate of adults and adolescents over 12 years of age. All functions can be used safely and values can be read out in one LCD DISPLAY. Measurement position is on adult upper arm only. The PATIENT is an intended OPERATOR. Blood pressure measurement determined with this device are equivalent to those obtained by a trained observer using the cuff/ stethoscope auscultation method, within the limits prescribed by the Recognized Consensus Standard (IEC 80601-2-30) for electronic sphygmomanometers. Precautions to Ensure Safe, Reliable Operation 1. Do not drop the unit. Protect it from sudden jars or shocks. 2. Do not insert foreign objects into any openings. 3. Do not attempt to disassemble the unit. 4. Do not crush the pressure cuff. 5. If the unit has been stored at temperatures below 0 °C, leave it in a warm place for about 15 minutes before using it. Otherwise, the cuff may not inflate properly. 6. If the unit has been stored at temperatures above 40 °C, leave it in a cool place for about 15 minutes before using it. Otherwise, the cuff may not inflate properly. 7. Do not store the unit in direct sunlight, high humidity or dust. 8.To avoid any possibility of accidental strangulation, keep this unit away from children and do not drape tubing around your neck. 9.Ensure that children do not use the instrument unsupervised; some parts are small enough to be swallowed. 10.Some may get a skin irritation from the cuff taking frequent readings over the course of the day, but this irritation typically goes away on its own after the monitor is removed. Safety Notice 3 Unit Illustration 6 Monitor Unit LCD Safety Notice Safety Notice 4 5 USB Adapter Jack START/STOP " Button " Set " " Button Memery Button " " Important Instructions Before Use 1. Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history. 2. Contact your physician if test results regularly indicate abnormal readings. 3. If you are taking medication, consult with your physician to determine the most appropriate time to measure your blood pressure. NEVER change a prescribed medication without first consulting with your physician. 4. Individuals with serious circulation problems may experience discomfort. Consult your physician prior to use. 5. For persons with irregular or unstable circulation resulting from diabetes, liver disease, arteriosclerosis or other medical conditions, there may be variations in blood pressure values measured at the wrist versus at the upper arm. Monitoring the trends in your blood pressure taken at either the arm or the wrist is nevertheless useful and important. 6. People suffering from vascular constriction, liver disorders or diabetes, people with cardiac pacemakers or a weak pulse, and women who are pregnant should consult their physician before measuring their blood pressure themselves. Different values may be obtained due to their condition. 7. People suffering from arrhythmias such as atrial or ventricular premature beats or atrial fibrillation only use this blood pressure monitor in consultation with your doctor. In certain cases oscillometric measurement method can produce incorrect readings. 15. Product is designed for its intended use only. Do not misuse in any way. 16. Product is not intended for infants or individuals who cannot express t…

Text truncated - open the document above for the full version.

External Photos

ReportNo.:EED32O81897501Page 39 of 49 10PHOTOGRAPHSOFEUTConstructionalDetails TestmodelNo.:DBP-62A2B ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32O81897501Page 40 of 49 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32O81897501Page 41 of 49 ViewofProduct-5 ViewofProduct-6 ReportNo.:EED32O81897501Page 42 of 49 ViewofProduct-7

ID Label/Location Info

Size: 40mm x25mm Arm-Type Fully Automatic Digital Blood Pressure Monitor Manufacturers by JOYTECH Healthcare Co., Ltd. No. 365, Wuzhou Road, Yuhang Economic Develop- ment Zone, Hangzhou City,311100 Zhejiang, China Power: 5.0V DC ,1000mA,5.0W; (or Batteries 4x 1.5V AAA) Series number: Manufacturing Date: Model: DBP-62A2B Made in China IP21 FCC ID:2AQVU0035 MR

Internal Photos

ReportNo.:EED32O81897501Page 42 of 49 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32O81897501Page 43 of 49 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32O81897501Page 44 of 49 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32O81897501Page 45 of 49 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32O81897501Page 46 of 49 ViewofProduct-15 ViewofProduct-16 ReportNo.:EED32O81897501Page 47 of 49 ViewofProduct-17 ViewofProduct-18 ReportNo.:EED32O81897501Page 48 of 49 ViewofProduct-19 ViewofProduct-20 ReportNo.:EED32O81897501Page 49 of 49 ViewofProduct-21 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***

RF Exposure Info

ReportNo.:EED32O81897502Page1of7 1COVERPAGE RFExposureEvaluationReport Product:Arm-typeFullyAutomaticDigitalBlood PressureMonitor Trademark:N/A Model/Typereference:DBP-62A2B SerialNumber:N/A ReportNumber:EED32O81897502 FCCID:2AQVU0035 DateofIssue:Dec.20,2022 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1093 447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: JOYTECHHealthcareCo.,Ltd No.365,WuzhouRoad,YuhangEconomicDevelopment Zone,HangzhouCity,Zhejiang,311100,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChenTomChen Approvedby:Date:Dec.20,2022 AaronMa CheckNo.:6044281122 ReportNo.:EED32O81897502Page2of7 2Version VersionNo.DateDescription 00Dec.20,2022Original ReportNo.:EED32O81897502Page3of7 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION............................................................................................................................................................................2 3CONTENTS........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ...................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT...................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ...........................................................................................4 4.4T EST L OCATION .............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS ......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ................................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT .................................................................................................................6 5.1.1Limits....................................................................................................................................................................6 5.1.2TestProcedure....................................................................................................................................................6 5.1.3EUTRFExposureEvaluation..........................................................................................................................7 ReportNo.:EED32O81897502Page4of7 4GeneralInformation 4.1ClientInformation Applicant:JOYTECHHealthcareCo.,Ltd AddressofApplicant:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, Zhejiang,311100,China Manufacturer:JOYTECHHealthcareCo.,Ltd AddressofManufacturer:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, Zhejiang,311100,China Factory:JOYTECHHealthcareCo.,Ltd AddressofFactory:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,HangzhouCity, Zhejiang,311100,China 4.2GeneralDescriptionofEUT ProductName:Arm-typeFullyAutomaticDigitalBloodPressureMonitor ModelNo.(EUT): DBP-62A2B TradeMark: N/A Devicetype: Portable 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:PhyPluskit AntennaType:PCBantenna AntennaGain:0dBi PowerSupply: Adapter Model:UE05LU4-050100SPA Input:100-240VAC,50/60Hz,0.2A Output:5.0V  1.0A,5.0W Battery6V SampleReceivedDate: Nov.29,2022 SampletestedDate: Nov.29,2022toDec.09,2022 Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32O81897502Page5of7 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32O81897502Page6of7 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 5.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportN…

Text truncated - open the document above for the full version.

Test Report

Bluetoothantennaspecifications 蓝牙天线规格 ShanghaiXinganMicroelectronicsTechnologyCo.,Ltd 上海芯感微电子科技有限公司 Allrightsreserved 版权所有不得复制 1 : AntennaDescription AntennaTypeMicrotripAntenna Antennapeakgain 0dBi Frequencyrange 2.402GHz~2.480GHz Connecttype Simulation 2 : AntennapictureonthePCBborad 3 : Antennaradiationof3Dpolar Solutionfrequencyat2.453G 3:Antenneradiationpattern

Test Report

ReportNo.:EED32O81897501Page1of34 Appendix:BluetoothLE ReportNo.:EED32O81897501Page2of34 Contents Contents.....................................................................................................................................................................................................2 DutyCycle..................................................................................................................................................................................................3 MaximumPeakConductedOutputPower..................................................................................................................................................7 -6dBBandwidth........................................................................................................................................................................................11 OccupiedChannelBandwidth..................................................................................................................................................................15 MaximumPowerSpectralDensityLevel..................................................................................................................................................19 BandEdge................................................................................................................................................................................................23 ConductedRFSpuriousEmission............................................................................................................................................................28 ReportNo.:EED32O81897501Page3of34 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant110000 NVNTBLE1M2440Ant110000 NVNTBLE1M2480Ant110000 NVNTBLE2M2402Ant110000 NVNTBLE2M2440Ant110000 NVNTBLE2M2480Ant110000 ReportNo.:EED32O81897501Page4of34 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81897501Page5of34 DutyCycleNVNTBLE1M2480MHzAnt1 DutyCycleNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81897501Page6of34 DutyCycleNVNTBLE2M2440MHzAnt1 DutyCycleNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81897501Page7of34 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNTBLE 1M 2402Ant10.4900.4930Pass NVNTBLE 1M 2440Ant10.0100.0130Pass NVNTBLE 1M 2480Ant1-0.710-0.7130Pass NVNTBLE 2M 2402Ant10.3600.3630Pass NVNTBLE 2M 2440Ant1-0.080-0.0830Pass NVNTBLE 2M 2480Ant1-0.830-0.8330Pass ReportNo.:EED32O81897501Page8of34 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81897501Page9of34 PeakPowerNVNTBLE1M2480MHzAnt1 PeakPowerNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81897501Page10of34 PeakPowerNVNTBLE2M2440MHzAnt1 PeakPowerNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81897501Page11of34 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.7730.5Pass NVNTBLE1M2440Ant10.7770.5Pass NVNTBLE1M2480Ant10.7850.5Pass NVNTBLE2M2402Ant11.4010.5Pass NVNTBLE2M2440Ant11.3910.5Pass NVNTBLE2M2480Ant11.380.5Pass ReportNo.:EED32O81897501Page12of34 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81897501Page13of34 -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81897501Page14of34 -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81897501Page15of34 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.074 NVNTBLE1M2440Ant11.076 NVNTBLE1M2480Ant11.083 NVNTBLE2M2402Ant12.096 NVNTBLE2M2440Ant12.089 NVNTBLE2M2480Ant12.085 ReportNo.:EED32O81897501Page16of34 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81897501Page17of34 OBWNVNTBLE1M2480MHzAnt1 OBWNVNTBLE2M2402MHzAnt1 ReportNo.:EED32O81897501Page18of34 OBWNVNTBLE2M2440MHzAnt1 OBWNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81897501Page19of34 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) DutyFactor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE 1M 2402Ant1-16.570-16.578Pass NVNTBLE 1M 2440Ant1-16.930-16.938Pass NVNTBLE 1M 2480Ant1-17.120-17.128Pass NVNTBLE 2M 2402Ant1-21.180-21.188Pass NVNTBLE 2M 2440Ant1-21.390-21.398Pass NVNTBLE 2M 2480Ant1-22.040-22.048Pass ReportNo.:EED32O81897501Page20of34 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81897501Page21of34 PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1

Test Report

ReportNo.:EED32O81897501Page22of34 PSDNVNTBLE2M2440MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 ReportNo.:EED32O81897501Page23of34 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-43.95-20Pass NVNTBLE1M2480Ant1-42.46-20Pass NVNTBLE2M2402Ant1-33.5-20Pass NVNTBLE2M2480Ant1-40.67-20Pass ReportNo.:EED32O81897501Page24of34 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O81897501Page25of34 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32O81897501Page26of34 BandEdgeNVNTBLE2M2402MHzAnt1Ref BandEdgeNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32O81897501Page27of34 BandEdgeNVNTBLE2M2480MHzAnt1Ref BandEdgeNVNTBLE2M2480MHzAnt1Emission ReportNo.:EED32O81897501Page28of34 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-39.27-20Pass NVNTBLE1M2440Ant1-25.5-20Pass NVNTBLE1M2480Ant1-35.23-20Pass NVNTBLE2M2402Ant1-36.05-20Pass NVNTBLE2M2440Ant1-37.24-20Pass NVNTBLE2M2480Ant1-34.51-20Pass ReportNo.:EED32O81897501Page29of34 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O81897501Page30of34 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32O81897501Page31of34 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32O81897501Page32of34 Tx.SpuriousNVNTBLE2M2402MHzAnt1Ref Tx.SpuriousNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32O81897501Page33of34 Tx.SpuriousNVNTBLE2M2440MHzAnt1Ref Tx.SpuriousNVNTBLE2M2440MHzAnt1Emission ReportNo.:EED32O81897501Page34of34 Tx.SpuriousNVNTBLE2M2480MHzAnt1Ref Tx.SpuriousNVNTBLE2M2480MHzAnt1Emission ***EndofReport***

Test Report

ReportNo.:EED32O81897501Page1of49 1 COVERPAGE TESTREPORT Product:Arm-typeFullyAutomaticDigital BloodPressureMonitor Trademark:N/A Model/Typereference:DBP-62A2B SerialNumber:N/A ReportNumber:EED32O81897501 FCCID:2AQVU0035 DateofIssue:Dec.20,2022 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: JOYTECHHealthcareCo.,Ltd No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,Zhejiang,311100,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChenTomChen Approvedby:Date:Dec.20,2022 AaronMa CheckNo.:6044281122 ReportNo.:EED32O81897501Page 2 of 49 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT............................................................................................................................................................................2 3VERSION.............................................................................................................................................................................3 4TESTSUMMARY...............................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT.................................................................................................................................5 5.3T EST C ONFIGURATION ..................................................................................................................................................6 5.4T EST E NVIRONMENT .....................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................7 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2).............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA.........................................................................................................12 7.1A NTENNA R EQUIREMENT ............................................................................................................................................12 7.2ACP OWER L INE C ONDUCTED E MISSIONS ................................................................................................................13 7.3M AXIMUM C ONDUCTED O UTPUT P OWER ..................................................................................................................16 7.4DTSB ANDWIDTH ........................................................................................................................................................17 7.5M AXIMUM P OWER S PECTRAL D ENSITY .....................................................................................................................18 7.6B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ...................................................................19 7.7R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................20 8APPENDIXBLE................................................................................................................................................................36 9PHOTOGRAPHSOFTESTSETUP..............................................................................................................................37 10PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS...................................................................................39 ReportNo.:EED32O81897501Page 3 of 49 3Version VersionNo.DateDescription 00Dec.20,2022Original ReportNo.:EED32O81897501Page 4 of 49 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 PASS DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32O81897501Page 5 of 49 5GeneralInformation 5.1ClientInformation Applicant: JOYTECHHealthcareCo.,Ltd AddressofApplicant: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,Zhejiang,311100,China Manufacturer: JOYTECHHealthcareCo.,Ltd AddressofManufacturer: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,Zhejiang,311100,China Factory: JOYTECHHealthcareCo.,Ltd AddressofFactory: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone,Hangzhou City,Zhejiang,311100,Chi…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:EED32O81897501Page 37 of 49 9PHOTOGRAPHSOFTESTSETUP TestmodelNo.:DBP-62A2B RadiatedspuriousemissionTestSetup-1 (Below1GHz) RadiatedspuriousemissionTestSetup-2( Above1GHz) ReportNo.:EED32O81897501Page 38 of 49 RadiatedspuriousemissionTestSetup-3( Above1GHz) Thereareabsorbingmaterialsundertheground. ConductedEmissionsTestSetup

Contact Information

Applicant

Lan Yingting(QA)
[email protected]0571-81957767Fax: 0571-81957750

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from JOYTECH HEALTHCARE CO., LTD.

2AQVU0050

Digital Thermometer

Dec 03, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU-AP301AW

Air purifier

Aug 23, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0049

Arm-type Fully Automatic Digital Blood Pressure Monitor

Aug 07, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0046

Arm-type Fully Automatic Digital Blood Pressure Monitor

Jan 21, 2024

Equipment Class

DTS - Digital Transmission System
Infrared Ear Thermometer - FCC ID 2AQVU0043 - JOYTECH HEALTHCARE CO., LTD.
2AQVU0043

Infrared Ear Thermometer

Sep 02, 2023

Equipment Class

DTS - Digital Transmission System