FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Š 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. JOYTECH HEALTHCARE CO., LTD./
  3. 2AQVU0044

2AQVU0044Infrared Ear Thermometer

JOYTECH HEALTHCARE CO., LTD.
Infrared Ear Thermometer - FCC ID 2AQVU0044 - JOYTECH HEALTHCARE CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 02, 2023
Application Purpose
Original Equipment
Date of Application
Sep 02, 2023
Equipment Note
Infrared Ear Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
JOYTECH HEALTHCARE CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Owner's Manual Infrared Ear Thermometer Model DET-1025b Contents Introduction 12 Introduction ......................................................02 Warning ......................................................03 Product Description ........................................... 04 Lcd Display Introduction ......................................... 05 Basic Functions .............................................. 06 Ear Thermometer Advantages ............................ 07 Body Temperature ..............................................09 Illustration For Use .......................................10 Temperature Taking Hints ..............................16 Memory Mode ...............................................18 Care And Cleaning .............................................19 Battery Replacement ..........................................21 Specifications .....................................................22 Troubleshooting .................................................23 Calibration .............................................................25 Symbol Explanation ......................................26 Service .............................................................27 Warranty .............................................................28 FCC Information ....................................................29 Electromagnetic Compatibility Information ...........31 Please read all instructions carefully and thoroughly before using this product. This appliance conforms to the following standards: ASTM E1965-98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature, ISO 80601-2-56 Medical electrical equipment —Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement, IEC 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and essential performance –Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment and complies with the requirements of IEC 60601-1-2(EMC) , AAMI ANSI ES60601-1(Safety) standards. And the manufacturer is ISO 13485 certified. Document No.: JDET-2904-005 Article No.: 002 Version: Z Date of Issue: XXXX.XX Telephone: +86-571-81957767 Fax: +86-571-81957750 JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, Hangzhou , Zhejiang 311100 China Made in China The DET-1025b thermometer is specifically designed for safe use in the eardrum. The Infrared Ear Thermometer is a device capable of measuring people's body temperature by detecting the intensity of infrared light emitted from the ear canal of human. It converts the measured heat into a temperature reading displayed on the LCD. When properly used, it will quickly assess your temperature in an accurate manner. Indications for Use:The infrared ear thermometer is intended for the intermittent measurement of human body temperature.The device can be reused by people of all ages for home use and clinical use. Intended use:The infrared ear thermometer is used to measure body temperature. Product Description 3 Basic Functions LCD Display Introduction 4 6 5 Warning This thermometer is intended for home use only. It's not meant to replace a visit to the doctor. Please consult with doctor if you have health concerns. 2. There is no gender or age limitation for using infrared ear thermometer. 3. To avoid inaccurate readings, always attach a new, clean probe cover for each temperature reading. 4. Do not expose the thermometer to temperature extremes (below -25°C/-13°F or over 55°C/131°F) nor excessive humidity (>95%RH). 5. This thermometer must only be used with this brand thermometer probe covers. 6. Keep the battery away from children. 9. Portable and mobile RF communications can affect the devise. The device needs special precaution regarding EMC according to the EMC information provided in the accompany documents. 10. ME equipment should not be cleaned and disinfected while in use. 1. 7. Remove battery from the device when not in operation for a long time. 8. Do not put the thermometer in direct sunlight or with cotton wool, otherwise the accuracy will be affected. 11 Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established. 12 The probe of the ME equipment shall not be serviced or maintained while in use with a patient. 1. Probe Cover 2. Probe 3. Test Button 4. Memory Button 5. Setting Button 6. Battery Cover 7. Dust Cover 8. Nightlight 9. LCD Ear Temperature Mode Memory Mode / Switch°C°F Probe cover detection and eject function The thermometer has been designed for use with or without probe cover. Users can press the eject button to remove the probe cover. Probe cover sign Ear temperature mode Temperature indictor Unit sign: °C or °F Temperature result Memory mode Object temperature mode Sound sign SwitchSound You can use the to choose whether to turn on or off the sound. Setting Button The object mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for example the baby's milk. → Please see the learn how to measure the object emperature. Illustration For Use section to Bluetooth Sign Bluetooth sign If the APP is successfully connected to the machine,the Bluetooth sign will always be on, otherwise it will keep flashing. The machine can store up to 30 sets of measurements. Each memory also records the measurement results mode. When the data exceeds 30 sets, the coverage starts from the earliest data. Beep Hint When the testing is done, it will sound one short beep. The thermometer has been designed for practical use. It's not meant to replace a visit to the doctor. Please als…

Text truncated - open the document above for the full version.

External Photos

ReportNo.:EED32P81026601Page 36 of 43 10PHOTOGRAPHSOFEUTConstructionalDetails ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32P81026601Page 37 of 43 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32P81026601Page 38 of 43 ViewofProduct-5 ViewofProduct-6

ID Label/Location Info

DET1025b DET1025b表体标签 JDET-2904-004 Z JDET-2904-004 Z 230425 Infrared Ear Thermometer Model:DET-1025b Measuring site:ear canal Reference body site:Oral Rating:DC1.5V(1xAAA alkaline battery) 1 2 1 7 . 0 34.3 +0 -0.5 + 0 - 0 . 5 Date of Manufacture:2023.04.25 FCC ID:2AQVU0044 Manufactured by JOYTECH Healthcare Co., Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopment Zone, Hangzhou , Zhejiang 311100 China

Internal Photos

ReportNo.:EED32P81026601Page 39 of 43 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32P81026601Page 40 of 43 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32P81026601Page 41 of 43 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32P81026601Page 42 of 43 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32P81026601Page 43 of 43 ViewofProduct-15 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***

RF Exposure Info

ReportNo.:EED32P81026602Page1of7 1COVERPAGE RFExposureEvaluationReport Product:InfraredEarThermometer Trademark:N/A Model/Typereference:DET-1025b SerialNumber:N/A ReportNumber:EED32P81026602 FCCID: 2AQVU0044 DateofIssue:Aug.29,2023 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1091 47CFRPart2.1093 447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: JOYTECHHealthcareCo.,Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChen TomChen Approvedby:Date:Aug.29,2023 AaronMa CheckNo.:2727060723 ReportNo.:EED32P81026602Page2of7 2Version VersionNo.DateDescription 00Aug.29,2023Original ReportNo.:EED32P81026602Page3of7 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION............................................................................................................................................................................2 3CONTENTS........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ...................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT...................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ...........................................................................................4 4.4T EST L OCATION .............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS ......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ................................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT .................................................................................................................6 5.1.1Limits....................................................................................................................................................................6 5.1.2TestProcedure....................................................................................................................................................6 5.1.3EUTRFExposureEvaluation..........................................................................................................................7 ReportNo.:EED32P81026602Page4of7 4GeneralInformation 4.1ClientInformation Applicant: JOYTECHHealthcareCo.,Ltd. AddressofApplicant: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Manufacturer: JOYTECHHealthcareCo.,Ltd. AddressofManufacturer: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Factory: JOYTECHHealthcareCo.,Ltd. AddressofFactory: No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China 4.2GeneralDescriptionofEUT ProductName:InfraredEarThermometer ModelNo.(EUT): DET-1025b TradeMark: N/A 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange: 2402MHz~2480MHz ModulationType: GFSK TestPowerGrade: Default TestSoftwareofEUT: PhyPlusKit AntennaType: PCBAntenna AntennaGain: -1.37612dBi PowerSupply: BatteryDC1.5V SampleReceivedDate: Jul.06,2023 SampletestedDate: Jul.06,2023toJul.18,2023 CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32P81026602Page5of7 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32P81026602Page6of7 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 5.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32P81026602Page7of7 5.1.3EUTRFExposureEvaluation ForStandalone: ForBLE Frequency (MHz) Max. Conducted Output power (dBm) Antenna …

Text truncated - open the document above for the full version.

Test Report

Report No.: RF8230406039-L1-R Page 1 of 10 Antenna Test Report Product Name: Bluetooth Module Report No. : RF8230406039-L1-R Product Model: JMD1102/JMD1105/JMD1106 Security Classification: Open Version:V1.0 Total Page: 10 HAIYUN Laboratory Report Prepared By: Checked By: Approved By: Krain Wu Vic Cai Flank Wang Report No.: RF8230406039-L1-R Page 2 of 10 Antenna Test Report Equipment: Bluetooth Module Model: JMD1102/JMD1105/JMD1106 Applicant: JOYTECH Healthcare Co., Ltd. Applicant address: No.365,Wuzhou Road311100 Hangzhou, Zhejiang ProvincePEOPLE'S REPUBLIC OF CHINA Manufacture: JOYTECH Healthcare Co., Ltd. Address: No.365,Wuzhou Road311100 Hangzhou, Zhejiang ProvincePEOPLE'S REPUBLIC OF CHINA Date of Receipt: Apr 7.2023 Date of Test: Apr 1.2023~May 10.2023 Issue Date: May 10.2023 Tested by: Shenzhen HAIYUN Testing Co., Ltd. Laboratory TEL: 0755-89990666-21508 FAX:0755-26801723 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen HAIYUN Testing Co., Ltd. Laboratory. This document may be altered or revised by Shenzhen HAIYUN Testing Co., Ltd. Laboratory. personnel only, and shall be noted in the revision section of the document. The test results of this report relate only to the tested sample identified in this report. Report No.: RF8230406039-L1-R Page 3 of 10 TABLE OF CONTENTS 1.Purose & Environment .................................................................................................................................. 4 1.1 Purpose ................................................................................................................................................. 4 1.2 Environment ......................................................................................................................................... 4 2.Test photos、Test Condition and DUT Antenna .......................................................................................... 5 2.1 Test photos ............................................................................................................................................ 5 2.2 Test Condition ...................................................................................................................................... 5 2.3 DUT Antenna ....................................................................................................................................... 6 3.2D-3D Radiation pattern ............................................................................................................................... 7 3.1 2D Radiation pattern test results ........................................................................................................... 7 3.2 3D Radiation pattern test results ........................................................................................................... 8 4.Peak Gain ...................................................................................................................................................... 9 3.3 Test results ........................................................................................................................................... 9 Report No.: RF8230406039-L1-R Page 4 of 10 1.Purose & Environment 1.1 Purpose • Meet the electrical performance index; • Confirm the antenna scheme to meet the design requirements; 1.2 Environment • Test Condition: the network analyzer(E5071C) and SATIMO microwave anechoic chamber • Passive measurement results are presented Report No.: RF8230406039-L1-R Page 5 of 10 2.Test photos、Test Condition and DUT Antenna 2.1 Test photos Microwave anechoic chamber 2.2 Test Condition The network Analyzer Report No.: RF8230406039-L1-R Page 6 of 10 2.3 DUT Antenna Antenna Report No.: RF8230406039-L1-R Page 7 of 10 3 2D Radiation pattern 3.1 2D Radiation pattern test results Antenna_2D Report No.: RF8230406039-L1-R Page 8 of 10 3 3D Radiation pattern 3.2 3D Radiation pattern test results Antenna_3D Report No.: RF8230406039-L1-R Page 9 of 10 4 Peak Gain 4.1Test results Antenna_Peak Gain Frequency(MHz) Peak_Gain . dBi 2400 -3.52746 2410 -2.85367 2420 -2.15516 2430 -1.78412 2440 -1.69437 2450 -1.55137 2460 -1.49915 2470 -1.37612 2480 -1.49079 2490 -1.57472 2500 -1.7318 Report No.: RF8230406039-L1-R Page 10 of 10 STATEMENT a) The test report applies only to the specific samples tested under conditions. b) The test report is invalid without the Inspection Seal. c) The test report is invalid without the signature of the test engineer, auditor, Approver. d) The test report is invalid if it is altered or copied. e) Partial replica is prohibited without permission of Shenzhen HAIYUN Testing Co., Ltd. Laboratory f) The test results presented in this report is only valid on the tested samples. g) Objections to this report should be submitted to the inspection organization in 15 days of receipting the report. It is not accepted if overdue. Shenzhen HAIYUN Testing Co., Ltd. Laboratory Address: No. 2 Danzi North Road, Kengzi Street, Pingshan District,Shenzhen,Guangdong, China Tel: 0755-26021222 Fax: 0755-26021723 (END OF REPORT)

Test Report

ReportNo.:EED32P81026601Page1of34 Appendix:BluetoothLE ReportNo.:EED32P81026601Page2of34 Contents Contents.....................................................................................................................................................................................................2 DutyCycle..................................................................................................................................................................................................3 MaximumPeakConductedOutputPower..................................................................................................................................................7 -6dBBandwidth........................................................................................................................................................................................11 OccupiedChannelBandwidth..................................................................................................................................................................15 MaximumPowerSpectralDensityLevel..................................................................................................................................................19 BandEdge................................................................................................................................................................................................23 ConductedRFSpuriousEmission............................................................................................................................................................28 ReportNo.:EED32P81026601Page3of34 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant165.651.832.46 NVNTBLE1M2440Ant164.61.92.46 NVNTBLE1M2480Ant164.61.92.46 NVNTBLE2M2402Ant133.814.714.69 NVNTBLE2M2440Ant134.524.624.67 NVNTBLE2M2480Ant133.814.714.69 ReportNo.:EED32P81026601Page4of34 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32P81026601Page5of34 DutyCycleNVNTBLE1M2480MHzAnt1 DutyCycleNVNTBLE2M2402MHzAnt1 ReportNo.:EED32P81026601Page6of34 DutyCycleNVNTBLE2M2440MHzAnt1 DutyCycleNVNTBLE2M2480MHzAnt1 ReportNo.:EED32P81026601Page7of34 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) Limit (dBm) Verdict NVNTBLE1M2402Ant11.7230Pass NVNTBLE1M2440Ant10.830Pass NVNTBLE1M2480Ant1030Pass NVNTBLE2M2402Ant11.7230Pass NVNTBLE2M2440Ant10.7930Pass NVNTBLE2M2480Ant1-0.0230Pass ReportNo.:EED32P81026601Page8of34 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32P81026601Page9of34 PeakPowerNVNTBLE1M2480MHzAnt1 PeakPowerNVNTBLE2M2402MHzAnt1 ReportNo.:EED32P81026601Page10of34 PeakPowerNVNTBLE2M2440MHzAnt1 PeakPowerNVNTBLE2M2480MHzAnt1 ReportNo.:EED32P81026601Page11of34 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.70.5Pass NVNTBLE1M2440Ant10.7050.5Pass NVNTBLE1M2480Ant10.7330.5Pass NVNTBLE2M2402Ant11.1470.5Pass NVNTBLE2M2440Ant11.1610.5Pass NVNTBLE2M2480Ant11.1460.5Pass ReportNo.:EED32P81026601Page12of34 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32P81026601Page13of34 -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 ReportNo.:EED32P81026601Page14of34 -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 ReportNo.:EED32P81026601Page15of34 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.039 NVNTBLE1M2440Ant11.044 NVNTBLE1M2480Ant11.047 NVNTBLE2M2402Ant12.05 NVNTBLE2M2440Ant12.054 NVNTBLE2M2480Ant12.051 ReportNo.:EED32P81026601Page16of34 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32P81026601Page17of34 OBWNVNTBLE1M2480MHzAnt1 OBWNVNTBLE2M2402MHzAnt1 ReportNo.:EED32P81026601Page18of34 OBWNVNTBLE2M2440MHzAnt1 OBWNVNTBLE2M2480MHzAnt1 ReportNo.:EED32P81026601Page19of34 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE1M2402Ant1-14.278Pass NVNTBLE1M2440Ant1-15.068Pass NVNTBLE1M2480Ant1-15.98Pass NVNTBLE2M2402Ant1-16.128Pass NVNTBLE2M2440Ant1-17.098Pass NVNTBLE2M2480Ant1-17.848Pass ReportNo.:EED32P81026601Page20of34 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:EED32P81026601Page21of34 PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1 ReportNo.:EED32P81026601Page22of34 PSDNVNTBLE2M2440MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 ReportNo.:EED32P81026601Page23of34 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-38.03-20Pass NVNTBLE1M2480Ant1-43.4-20Pass NVNTBLE2M2402Ant1-35.84-20Pass NVNTBLE2M2480Ant1-42.15-20Pass ReportNo.:EED32P81026601Page24of34 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32P81026601Page25of34 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32P81026601Page26of34 BandEdgeNVNTBLE2M2402MHzAnt1Ref BandEdgeNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32P81026601Page27of34 BandEdgeNVNTBLE2M2480MHzAnt1Ref BandEdgeNVNTBLE2M2480MHzAnt1Emission ReportNo.:EED32P81026601Page28of34 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-41.92-20Pass NVNTBLE1M2440Ant1-40.25-20Pass NVNTBLE1M2480Ant1-42.4-20Pass NVNTBLE2M2402Ant1-43.2-20Pass NVNTBLE2M2440Ant1-44.1-20Pass NVNTBLE2M2480Ant1-41.58-20Pass ReportNo.:EED32P81026601Page29of34 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32P81026601Page30of34 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32P81026601Page31of34 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32P81026601Page32of34 Tx.SpuriousNVNTBLE2M2402MHzAnt1Ref Tx.SpuriousNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32P…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32P81026601Page1of43 1 COVERPAGE TESTREPORT Product:InfraredEarThermometer Trademark:N/A Model/Typereference:DET-1025b SerialNumber:N/A ReportNumber:EED32P81026601 FCCID: 2AQVU0044 DateofIssue:Aug.29,2023 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: JOYTECHHealthcareCo.,Ltd. No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChen TomChen Approvedby:Date:Aug.29,2023 AaronMa CheckNo.:2727060723 ReportNo.:EED32P81026601Page 2 of 43 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT............................................................................................................................................................................2 3VERSION.............................................................................................................................................................................3 4TESTSUMMARY...............................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT.................................................................................................................................5 5.3T EST C ONFIGURATION ..................................................................................................................................................6 5.4T EST E NVIRONMENT .....................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................7 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2).............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA.........................................................................................................12 7.1A NTENNA R EQUIREMENT ............................................................................................................................................12 7.2M AXIMUM C ONDUCTED O UTPUT P OWER ..................................................................................................................13 7.3DTSB ANDWIDTH ........................................................................................................................................................14 7.4M AXIMUM P OWER S PECTRAL D ENSITY .....................................................................................................................15 7.5B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ...................................................................16 7.6R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................17 8APPENDIXBLE................................................................................................................................................................33 9PHOTOGRAPHSOFTESTSETUP..............................................................................................................................34 10PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS...................................................................................36 ReportNo.:EED32P81026601Page 3 of 43 3Version VersionNo.DateDescription 00Aug.29,2023Original ReportNo.:EED32P81026601Page 4 of 43 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 N/A DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS N/A:Onlybatterysupplyissupportedandthisitemisnotconsidered. Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32P81026601Page 5 of 43 5GeneralInformation 5.1ClientInformation Applicant:JOYTECHHealthcareCo.,Ltd. AddressofApplicant:No.365,WuzhouRoad,YuhangEconomicDevelopmentZone, HangzhouCity,31100Zhejiang,China Manufacturer:JOYTECHHealthcareCo.,Ltd. AddressofManufacturer:No.365,Wu…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Lan Yingting(QA)
[email protected]0571-81957767Fax: 0571-81957750

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from JOYTECH HEALTHCARE CO., LTD.

2AQVU0050

Digital Thermometer

Dec 03, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU-AP301AW

Air purifier

Aug 23, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0049

Arm-type Fully Automatic Digital Blood Pressure Monitor

Aug 07, 2024

Equipment Class

DTS - Digital Transmission System
2AQVU0046

Arm-type Fully Automatic Digital Blood Pressure Monitor

Jan 21, 2024

Equipment Class

DTS - Digital Transmission System
Infrared Ear Thermometer - FCC ID 2AQVU0043 - JOYTECH HEALTHCARE CO., LTD.
2AQVU0043

Infrared Ear Thermometer

Sep 02, 2023

Equipment Class